首页 | 本学科首页   官方微博 | 高级检索  
     

空间弯管安装转角计算的新方法
引用本文:张霞,张天会,闫沛军,徐人平. 空间弯管安装转角计算的新方法[J]. 中国农村水利水电, 2005, 0(12): 68-70
作者姓名:张霞  张天会  闫沛军  徐人平
作者单位:1. 云南农业大学工程技术学院,昆明,650216
2. 水电十四局,云南,昆明,650226
3. 昆明理工大学,昆明,650093
摘    要:提出了一种计算空间弯管安装转角的新方法,并应用到云南省临沧地区忙海河三级电站和楚雄州老虎山一级和二级电站空间弯管的安装中。根据实际施工的应用,该方法与投影几何计算方法进行了对比分析,认为采用投影几何计算方法虽然较精确但比较烦琐,不易理解,难于掌握;而采用新的计算方法计算简单、实用,虽然有一定的误差,但误差较小,通过安装过程中微小的调整就能满足要求。这种新的计算空间弯管安装转角的方法可以应用到其他工程空间弯管安装过程中。

关 键 词:空间弯管  安装转角  计算方法  应用分析
文章编号:1007-2284(2005)12-0068-03
修稿时间:2005-04-11

A New Calculation Method for Installing Angle in Three-dimensional Siphon
ZHANG Xia,ZHANG Tian-hui,YAN Pei-jun,XU Ren-ping. A New Calculation Method for Installing Angle in Three-dimensional Siphon[J]. China Rural Water and Hydropower, 2005, 0(12): 68-70
Authors:ZHANG Xia  ZHANG Tian-hui  YAN Pei-jun  XU Ren-ping
Affiliation:ZHANG Xia~1,ZHANG Tian-hui~1,YAN Pei-jun~3,XU Ren-ping~2
Abstract:This paper brings forward a new method of calculating installing angle for three-dimensional siphon,and applies it in the installing of three-dimensional siphons in the Third-grade Power Station of Manghai River and the Laohushan Power Station of Chuxiong Prefecture,Yunnan Province.According to the application and contrasted with the traditional method-projection geometry calculation,it can be concluded : Adopting the traditional method,the calculating result is more accurate,but it is very intricate and not easy to command;this new calculating method is simple and easy to command;although the calculating result has some error,the error is very small and in the installing process through small adjustment it can satisfy the requirement.Therefore the new method is very practical,and it can be applied in the installation of other similar three-dimensional siphons.
Keywords:three-dimensional siphon  installing angle  calculation method  application analysis
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《中国农村水利水电》浏览原始摘要信息
点击此处可从《中国农村水利水电》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号