首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Application and Test Analysis of Anti-float Anchor in Submerged Square
作者姓名:ZENG Guo-ji~  HU Zhi~  HU Dai-wen~  DAI Jun~
摘    要:In this paper, based on the reconstruction project of the bar in Shekou, Shenzhen, under the action of circular loads, the ultimate bearing capacity and the stress along the anti-float anchor were tested and the change of the loading was analyzed in an in-situ test, which may be taken as reference for other similar projects with the same strata.

关 键 词:anti-float  anchor  circulating  load  test  analysis
修稿时间:2004/8/15 0:00:00

Application and Test Analysis of Anti-float Anchor in Submerged Square
ZENG Guo-ji,HU Zhi,HU Dai-wen,DAI Jun.Application and Test Analysis of Anti-float Anchor in Submerged Square[J].Storage & Process,2004(6):35-39.
Authors:ZENG Guo-ji  HU Zhi  HU Dai-wen  DAI Jun
Institution:ZENG Guo-ji~,HU Zhi~,HU Dai-wen~,DAI Jun~
Abstract:In this paper, based on the reconstruction project of the bar in Shekou, Shenzhen, under the action of circular loads, the ultimate bearing capacity and the stress along the anti-float anchor were tested and the change of the loading was analyzed in an in-situ test, which may be taken as reference for other similar projects with the same strata.
Keywords:anti-float anchor  circulating load  test analysis