摘    要:用排气扇与各种通风方式对高大平房仓进行降温对比试验,将试验仓与对比仓的降温情况、通风效率、表观风速和水分变化进行比较。结果表明,用排气扇通风具有耗电低、降温均匀、不分损耗低和操作简便等优势,适用于冷空气资源充足的地区。

关 键 词:排气访  通风降温  对比试验  粮食储藏

CONTROL TEST OF EXHAUST FAN FOR LOWERING TEMPERATURE WITH VENTILATION
Su Xuqiang,Jiang Hanzhong,Miao Qingchao.CONTROL TEST OF EXHAUST FAN FOR LOWERING TEMPERATURE WITH VENTILATION[J].Grain Storage,2002,31(4):33-35.
Authors:Su Xuqiang  Jiang Hanzhong  Miao Qingchao
Abstract:In large warehouse,a control test of lowering temperature with exhaust fan and other equipment in lowering temperature,ventilating efficiency,air flow rate and moisture content was carried out.The results showed that exhaust fan has the advantages of low consumption of energy and moisture,simple operation and lowering temperature uniform.Ventilation with exhaust fan is fit for cool area.