首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   14篇
  免费   2篇
畜牧兽医   16篇
  2024年   1篇
  2022年   2篇
  2020年   1篇
  2019年   1篇
  2018年   1篇
  2017年   2篇
  2015年   1篇
  2013年   1篇
  2011年   1篇
  2010年   1篇
  2009年   1篇
  2006年   2篇
  1993年   1篇
排序方式: 共有16条查询结果,搜索用时 15 毫秒
1.
Respiratory‐induced organ displacement during image acquisition can produce motion artifacts and variation in spatial localization of an organ in diagnostic computed tomography (CT) examinations. The purpose of this prospective study was to quantify respiratory‐induced abdominal organ displacement in dorsal and ventral recumbency using five normal dogs. All dogs underwent CT examinations using 64 multidetector row CT (64‐MDCT). A “3‐dimensional (3D) apneic CT exam” of the abdomen was acquired followed by a “4‐dimensional (4D) ventilated CT exam.” The liver, pancreas, both kidneys, both medial iliac lymph nodes, and urinary bladder were delineated on the 3D‐apneic examination and the organ outlines were compared to the maximum alteration in organ position in the 4D‐ventilated examination. Displacement was measured in dorsal‐to‐ventral (DV), right‐to‐left (RL), and cranial‐to‐caudal (CC) directions. Respiratory‐induced displacement of canine abdominal organs was not predictable and showed large variability in the three directions evaluated. For most canine abdominal organs, dorsal recumbency provided overall the least amount of displacement among all directions evaluated except for liver and urinary bladder. For liver, a large variability was found for all directions and a statistically significant difference was found only in the RL direction with ventral recumbency exhibiting less displacement (P = 0.0099). For the urinary bladder, ventral recumbency also provided less displacement but this was statistically significant only in the RL direction (P < 0.0001). Findings from this study indicated that dorsal recumbency may be preferred for minimizing respiratory motion artifacts in whole abdomen studies, but ventral recumbency may be preferred for liver and urinary bladder studies when respiration cannot be controlled.  相似文献   
2.
Objective – To evaluate the effect of body position on the arterial partial pressures of oxygen and carbon dioxide (PaO2, PaCO2), and the efficiency of pulmonary oxygen uptake as estimated by alveolar‐arterial oxygen difference (A‐a difference). Design – Prospective, randomized, crossover study. Setting – University teaching hospital, intensive care unit. Animals – Twenty‐one spontaneously breathing, conscious, canine patients with arterial catheters placed as part of their management strategy. Interventions – Patients were placed randomly into lateral or sternal recumbency. PaO2 and PaCO2 were measured after 15 minutes in this position. Patients were then repositioned into the opposite position and after 15 minutes the parameters were remeasured. Measurements and Main Results – Results presented as median (interquartile range). PaO2 was significantly higher (P=0.001) when patients were positioned in sternal, 91.2 mm Hg (86.0–96.1 mm Hg), compared with lateral recumbency, 86.4 mm Hg (73.9–90.9 mm Hg). The median change was 5.4 mm Hg (1.1–17.9 mm Hg). All 7 dogs with a PaO2<80 mm Hg in lateral recumbency had improved arterial oxygenation in sternal recumbency, median increase 17.4 mm Hg with a range of 3.8–29.7 mm Hg. PaCO2 levels when patients were in sternal recumbency, 30.5 mm Hg (27.3–32.7 mm Hg) were not significantly different from those in lateral recumbency, 32.2 mm Hg (28.3–36.0 mm Hg) (P=0.07). The median change was ?1.9 mm Hg (?3.6–0.77 mm Hg). A‐a differences were significantly lower (P=0.005) when patients were positioned in sternal recumbency, 21.7 mm Hg (17.3–27.7 mm Hg), compared with lateral recumbency, 24.6 mm Hg (20.4–36.3 mm Hg). The median change was ?3.1 mm Hg (?14.6–0.9 mm Hg). Conclusions – PaO2 was significantly higher when animals were positioned in sternal recumbency compared with lateral recumbency, predominantly due to improved pulmonary oxygen uptake (decreased A‐a difference) rather than increased alveolar ventilation (decreased PaCO2). Patients with hypoxemia (defined as PaO2<80 mm Hg) in lateral recumbency may benefit from being placed in sternal recumbency. Sternal recumbency is recommended to improve oxygenation in hypoxemic patients.  相似文献   
3.

Objective

To assess the cardiopulmonary effects caused by reverse Trendelenburg position (RTP) at 5° and 10° in sevoflurane-anesthetized yearling steers.

Study design

Prospective, experimental study.

Animals

Eight Holstein steers aged (mean ± standard deviation) 12 ± 2 months and weighing 145 ± 26 kg.

Methods

In the first phase of the study, the individual minimum alveolar concentration (MAC) of sevoflurane was determined using electrical stimulation. In the second phase, the effects of RTP were assessed. The animals were anesthetized on three separate events separated by ≥7 days in an incomplete crossover design: control treatment using a table without tilt (RTP0); treatment with the table at 5° RTP (RTP5) and table tilted 10° RTP (RTP10). Subjects were physically restrained in dorsal recumbency on the table, which was already tilted according to each treatment. Anesthesia was induced with sevoflurane at 8% in 5 L minute–1 oxygen via face mask followed by maintenance with sevoflurane at 1.3 MAC and spontaneous breathing. Cardiopulmonary variables were obtained immediately after instrumentation (T0) and then after 30, 60, 120 and 180 minutes (T30, T60, T120 and T180, respectively).

Results

The mean sevoflurane MAC for the eight steers was 2.12 ± 0.31%. Cardiac output was lower at all time points and the systemic vascular resistance index was higher at T120 and T180 in RTP10 compared with RTP0. Oxygen consumption was lower at T0 and at T180 in RTP10 compared with RTP0 and at all time points except T30 compared with RTP5. Oxygen extraction was lower at T0 in RTP10 compared with RTP0 and RTP5, and at T60 and T180 compared with RTP5.

Conclusions and clinical relevance

RTP 5° and 10° did not improve ventilatory and oxygenation variables in sevoflurane-anesthetized steers when compared with no tilt, however the cardiovascular variables were adversely affected in RTP10.  相似文献   
4.
Controlled mechanical ventilation (CMV) is routinely used in equine anaesthesia, with many different options available to mechanically deliver breaths. The complexity of respiratory pathophysiology in anaesthetised horses and the wide range of devices available is described in this scoping review. The first part of the review outlines basic equine respiratory physiology and pathophysiology during anaesthesia to illustrate what makes horses prone to inefficient gas exchange and ventilation when they are recumbent. The difference between spontaneous ventilation and CMV is reviewed and basic considerations of CMV are explored in more detail.  相似文献   
5.
The objective of this study was to evaluate changes in intra-abdominal pressure (IAP) in horses with colic by associating the underlying etiologies with directly acquired IAP values and survival rate. This is a 2-year cohort study (2014–2016). Horses with clinical signs of colic were admitted to the veterinary teaching hospital during the period 2014–2016. Twenty-eight horses, of different breeds, males (stallions and geldings) and females, aged between 2 and 20 years, and weighing from 300 to 450 kg presenting with clinical signs of colic, were included in the study. IAP was directly acquired at the right flank (standing under sedation) and at the linea alba (supine position under general anesthesia). Twenty IAP measurements were recorded at end expiration for each recording site. IAP values >0.0 mmHg, obtained at the upper right flank in the standing position, were associated with surgical treatment (P < .05). In these cases, signs of colic were associated with strangulated obstructions of the large colon, and a greater likelihood of death as a result of colic (P < .001). Intra-abdominal pressure varied considerably in horses with colic, even for the same underlying etiologies. Horses with colic related to strangulating obstructions of the large intestine had IAP >.0 mmHg, at the upper right flank. These horses were also considerably more likely to require surgical intervention (P < .05) and death/euthanasia was more likely in this group of horses (P < .001).  相似文献   
6.
7.
MarthaL.  Moon  DVM  MS  Bruce W.  Keene  DVM  MS  Pierre  Lessard  DVM  PhD  Jim  Lee  BS 《Veterinary radiology & ultrasound》1993,34(5):315-320
An exaggerated "horizontal" alignment of the heart (increased sternal contact) and tortuous, redundant aorta are often seen on thoracic radiographs of older cats. Eighty-five cats, divided into 3 age groups [young (6–15 months), middle aged (3–7 years), old (10–17 years)], were determined to be normal on history, auscultation, ECG, and echocardiogram. Lateral and VD thoracic radiographs were examined and measured for evidence of these changes. Forty percent of cats 10 years or older were found to have the horizontal cardiac alignment, and 28% had the redundant aorta. These changes were not seen in Groups 1 and 2 of younger and middle aged cats. The angle between the heart and sternum in Group 3 (old) cats was significantly smaller than the same angle in younger cats. Systemic hypertension and hyperthyroidism, possible pathologic causes for this variation, were unlikely related to the cardiovascular changes due to the large number of older cats with this change, and lack of evidence of left ventricular hypertrophy.  相似文献   
8.
ObjectiveTo examine the spread of solution in the epidural space of sternally recumbent dogs.Study designProspective experimental trial.AnimalsTen healthy adult Beagle dogs weighing 7.6 ± 1.1 kg.MethodsDogs were anaesthetized with total intravenous propofol infusion, and placed in sternal recumbency. A volume of 0.2 mL kg?1 contrast medium (CM) containing 1% new methylene blue (MB) dye was administered into the lumbosacral epidural space. Left to right lateral radiographs using a horizontal beam were taken every 5 minutes for 45 minutes. The perpendicular height (PH) between floor of the epidural canal of the highest vertebra and that of lumbosacral spinal canal was measured on radiographs. The angle of slope from the injection point toward the highest vertebral floor was measured. Immediately after taking the last radiographic image, dogs were euthanized and a laminectomy was performed from the cervical to lumbar vertebrae for visual evaluation of MB spread. The spread of CM and of MB as counted in number of stained vertebra were compared, and each of these data sets were further compared to PH and angle, using linear regression analyses.ResultsThe PH and angle were (mean ± SD) 3.8 ± 0.8 cm and 14.8 ± 2.8° respectively. The most cranial spread of CM was at 12.7 ± 5.7 (range: C6–L3) vertebrae, and at 14.0 ± 5.4 (range: C6–L2) vertebrae for MB staining. There were no significant correlations between PH and spread of CM (R2 = 0.08) or MB (R2 = 0.13), between angle and spread of CM (R2 = 0.05) or MB (R2 = 0.02), respectively. CM and MB demonstrated proportional relationship (R2 = 0.82, p < 0.001).ConclusionsNo significant inhibitory effect of upward slope on cranial epidural spread of the solution was observed. Other factors may have greater effect on epidural spread in sternally recumbent dogs.  相似文献   
9.

Objective

The aim of this study was to investigate whether an increased frequency of gastro-oesophageal reflux (GOR) is more common in large-sized, deep-chested dogs undergoing spinal surgery in sternal recumbency than in small-sized, barrelchested dogs.

Study design

Prospective, cohort study.

Animals

Nineteen small-sized, barrel-chested dogs (group B) and 26 large-sized, deep-chested dogs (group D).

Methods

All animals were premedicated with intramuscular (IM) acepromazine (0.05 mg kg?1) and pethidine (3 mg kg?1) IM. Anaesthesia was induced with intravenous sodium thiopental and maintained with halothane in oxygen. Lower oesophageal pH was monitored continuously after induction of anaesthesia. Gastro-oesophageal reflux was considered to have occurred whenever pH values > 7.5 or < 4 were recorded. If GOR was detected during anaesthesia, measures were taken to avoid aspiration of gastric contents into the lungs and to prevent the development of oesophagitis/oesophageal stricture.

Results

The frequency of GOR during anaesthesia was significantly higher in group D (6/26 dogs; 23.07%) than in group B (0/19 dogs; 0%) (p = 0.032). Signs indicative of aspiration pneumonia, oesophagitis or oesophageal stricture were not reported in any of the GOR cases.

Conclusions and clinical relevance

In large-sized, deep-chested dogs undergoing spinal surgery in sternal recumbency, it would seem prudent to consider measures aimed at preventing GOR and its potentially devastating consequences (oesophagitis/oesophageal stricture, aspiration pneumonia).  相似文献   
10.
In this retrospective study the effect of thoracic positioning on the visibility and size of selected cranial thoracic structures in dogs was investigated. Dorsoventral (DV), ventrodorsal (VD) as well as left lateral recumbent (LLR) and right lateral recumbent (RLR) thoracic radiographs of 17 large, 15 medium, and 10 small skeletally mature dogs were evaluated. The craniodorsal and cranioventral mediastinum, the cupula pleura and sternal lymph nodes were examined. The effect of obesity was also evaluated. The craniodorsal mediastinum was better delineated on DV radiographs and was wider on VD radiographs. The craniodorsal mediastinal width: width of T2 cranial end-plate on VD radiographs was 2.41 for all groups combined and obesity significantly influenced this value. The cranioventral mediastinum was more visible in RLR and VD radiographs. A normal sternal lymph node soft tissue opacity was seen most commonly in RLR in large breed dogs and had a mean length of 30 mm. The pulmonary cupula extended beyond the first rib on all views and extended more cranially and was better visualised on VD than DV views.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号