排序方式: 共有26条查询结果,搜索用时 46 毫秒
1.
《Veterinary anaesthesia and analgesia》2023,50(2):188-196
ObjectiveTo describe an ultrasound-guided lateral pre-iliac (LPI) and parasacral (PS) approach in feline cadavers (phase I) and compare the perioperative analgesic use and complications in cats administered LPI and PS blocks (group PNB) or epidural anesthesia (group EPI) for pelvic limb surgery (phase II).Study designExperimental uncontrolled, anatomic and retrospective cohort study.AnimalsA group of eight feline cadavers and 52 medical records.MethodsBilateral LPI and PS approaches with 0.1 mL kg–1 of dye to stain the femoral and obturator nerves and the lumbosacral trunk, respectively, were performed on each cadaver. Nerve staining effect was evaluated upon dissections (phase I). Perioperative analgesics use, and complication rates were retrospectively compared between groups PNB and EPI (phase II). Continuous data were compared using the Mann–Whitney U test and the prevalence of events with Fisher’s exact test. Differences were considered significant when p < 0.05.ResultsDissections revealed that the LPI approach stained 94% and 75% of the femoral and obturator nerves, respectively. The PS approach stained 100% of the lumbosacral trunks. Cats enrolled in group PNB (n = 23) were administered lower doses of intraoperative opioids than those in group EPI (n = 25) (p = 0.006). Intraoperative rescue analgesia was required in 60% and 17.4% of cats enrolled in groups EPI and PNB, respectively (p = 0.003). Group PNB required more intraoperative anticholinergics than group EPI (p = 0.02). There were no differences in postoperative pain scores, analgesic use and complication rates.Conclusions and clinical relevanceThe ultrasound-guided LPI and PS approach stained the femoral/obturator nerves and the lumbosacral trunk, respectively, in feline cadavers. Furthermore, PNB was associated with lower intraoperative opioid use and similar postoperative pain and analgesic use compared with epidural anesthesia in a cohort of cats undergoing surgery of the pelvic limb. 相似文献
2.
R.D. Montgomery D.V.M. M.S. R.B. Fitch D.V.M. M.S. J.T. Hathcock D.V.M. M.S. R.F. Laprade M.D. M.E. Wilson R.T. P.D. Garrett D.V.M. M.S. 《Veterinary radiology & ultrasound》1995,36(4):276-282
The intercondylar fossa is believed to play an important role in the pathology of cranial cruciate ligament rupture and therefore has received considerable attention in the last decade. Accurate radiographic imaging of the intercondylar fossa requires that the central x-ray beam pass through the center of the intercondylar "tunnel". The anatomy of the canine intercondylar fossa is similar to humans, however, the orientations of the intercondylar fossa's differ. Consequently, the positioning techniques described for humans are not appropriate for the dog. To pass through the center of the dog, intercondylar fossa, the central x-ray beam should be 12° (S.D. 1.7°) caudal from the femoral diaphysis in the sagittal plane and obliqued caudolateral to craniomedial 7° (S.D. 0.60°) (caudo78°proximo7° lateralcraniodistomedial oblique). Cross table positioning was used with the hip flexed and the radiograph cassette placed on the cranial surface of the stifle. However, superimposition of the tuber ischii and soft tissues caudal to the femur made 15° to 20° the best angle obtainable. There was not a significant difference (p = 0.17) in the notch width index between a 12° versus 20° angle of the central x-ray beam caudal to the femoral diaphysis, both with 7° of external rotation of the stifle. The notch width index of 0.252 obtained from radiographic measurements was not significantly different from measurements obtained grossly of 0.254 (n = 26; p = 0.69). Failure to oblique the central x-ray beam caused a significant (p = 0.0008) decrease in the apparent fossa width radiographically. 相似文献
3.
Diego F Echeverry Francisco G Laredo Francisco Gil Eliseo Belda Marta Soler Amalia Agut 《Veterinary anaesthesia and analgesia》2012,39(6):611-617
ObjectiveTo evaluate the dye extent and distribution at the lumbar plexus (LP) of three volumes of local anaesthetic-methylene-blue solution administered close to the femoral nerve (FN) by the use of a ventral ultrasound (US)-guided suprainguinal approach (SIA).Study designProspective experimental trial.AnimalsTwenty mongrel canine cadavers weighing 17.7 ± 3.8 kg (mean ± SD).MethodsThe left and right LP of two cadavers were dissected to identify the FN, obturator nerve (ON) and lateral femoral cutaneous nerve (LFCN). The extent and distribution of dye at the LP of each of three volumes of injectate of 0.2, 0.4 and 0.6 mL kg?1 administered close to the FN by a ventral US-guided SIA then were studied in a further 18 dog cadavers (n = 6 per group). Staining of ≥2 cm along the target nerves was indicative of sufficient spread to produce a nerve block.ResultsThe ventral US-guided SIA allowed the observation of the FN within the iliopsoas muscle (IPM) in a total of 17 cadavers. The assessment of the dye extent and distribution revealed a similar pattern regardless of the injected volume. From the injection site, the spreading of injectate occurred in cranial, lateral and caudal directions. The FN and ON were effectively stained in all the cases. The LFCN was not effectively stained in any case.Conclusions and clinical relevanceA volume of 0.2 mL kg?1 administered close to the FN by a ventral US-guided SIA produced a sufficient distribution of the injectate within the IPM to produce effective staining of the FN and ON. This US-guided technique may be an appropriate alternative to previously reported techniques based on electrolocation to block the FN and ON in the dog. 相似文献
4.
牛病毒性腹泻病以发热、口腔及消化道粘膜糜烂、腹泻为主要症状,可引起怀孕母牛流产或产畸型胎儿,给养牛业造成巨大的经济损失,该病已成为当前严重危害我国养牛业的传染病之一。由于大部分感染BVDV的牛不表现特征性的临床症状和病理变化,而且引起腹泻和消化道黏膜糜烂或溃疡的疾病很多,所以确诊需进行实验室检查。目前实验室检测BVDV的主要方法是利用美国IDEXX公司ELISA诊断试剂盒,通过BVDV抗原和抗体的检测区别牛群持续感染牛。用于检测BVDV的样品种类有许多种,绝大多数是采集血液(血清)或牛奶样品进行检测。本试验对奶牛进行耳组织采样,同时采集血液和牛奶,用三种样品在相同条件下同时检测BVDV抗原,用血清和牛奶样品检测抗体,比较样品的检测结果。结果表明,这三种样品检测结果具有一致性,且耳组织采样更宜于大面积筛查。 相似文献
5.
基于Multisim的抗干扰AM通信系统设计 总被引:1,自引:0,他引:1
刘博文 《河南农业大学学报》2011,45(4):459-462
分析了抗干扰AM通信系统原理和抗干扰的方法,并利用Multisim虚拟仿真软件为试验平台,设计抗干扰AM通信系统电路,利用Multisim提供的示渡器模块和频谱分析模块,分别对AM调制波和干扰抑制后的解调渡进行了波形和频谱分析.结果表明,Multisim在通信电路仿真中具有快速、准确、灵活的优点,而且所设计的自适应陷波... 相似文献
6.
The frequency band of conventional partial discharge (PD) measurement systems is selected just within several ten kilohertz. With the development of computer and digital signal processing techniques, wide frequency band (WFB) measurement systems have been used to detect PD in electrical equipment for its higher sensitivity. Nevertheless, the WFB measurement systems are easy suffered from the interference of strong field electromagnetism noises. A set of PD online monitoring system with frequency band from 50 kHz to 1 megahertz used for transformer is developed, in which pre-processing device and cascaded 2nd order IIR lattice notch digital filter are mainly used to suppress periodic narrow-band interference. With analysis of field monitored signal at a 220 kV substation, it is shown that the monitoring system not only can detect and extract the discharge pulse signal effectively, but also has the powerful capability of suppressing interference. 相似文献
7.
In order to improve the long-playing frequency tracking ability in the signal processing for coriolis mass flowmeter (CMF) , a new IIR adaptive notch filter (ANF) is developed via steiglitz-mcBride method (SMM) and applied to filter the sensor output signal whose frequency, amplitude and phase are time-varying following the random walk model. The proposed method can detect the signal frequency fleetly and track the frequency variations continuously. The tracking performances of the proposed method and the adaptive lattice notch filter (LANF) method are investigated with computer simulations. Simulations demonstrate the superiority of the proposed method and show it has advantages of fast convergence rate, insensitivity to initial phase variations, and higher long-playing tracking stability and accuracy than LANF method. 相似文献
8.
9.
新型马铃薯挖掘机的研制与开发 总被引:17,自引:0,他引:17
本文主要论述了4SW系列马铃薯挖掘机的研制与开发过程、主要部件的设计及参数的选择;文中所述的机型经过试验,生产考核证明所选参数及计算是正确的。 相似文献
10.