首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   31篇
  免费   5篇
  国内免费   3篇
林业   1篇
农学   1篇
综合类   6篇
水产渔业   1篇
畜牧兽医   30篇
  2021年   6篇
  2020年   2篇
  2019年   1篇
  2018年   2篇
  2017年   1篇
  2015年   3篇
  2014年   2篇
  2013年   2篇
  2010年   2篇
  2009年   2篇
  2008年   3篇
  2007年   1篇
  2006年   1篇
  2005年   3篇
  2004年   5篇
  2002年   2篇
  2001年   1篇
排序方式: 共有39条查询结果,搜索用时 203 毫秒
1.
The objective of this study was to study the morphological pattern of bone maturation of the hindlimb bones of Rhea americana and find out how it can affect bone morphology after a taphonomic process. Juvenile specimens (n = 10) ranging from one month old to eight months old were studied. For comparison, bones from adults and juveniles from museum specimens (n = 4 and n = 6, respectively) were studied. In fresh bones, ossification centres were identified in the proximal and distal epiphyses of the tibiotarsi and in the proximal epiphysis of the tarsometatarsi, whereas the distal region of the femora and tarsometatarsi showed abundance of cartilage. The development and extension of the ossification centres of the tibiotarsi were different. In the proximal epiphysis, the centre presented less development with respect to the distal epiphysis. In the dry tibiotarsi, the proximal centre was absent and the distal one was well preserved. Both the fresh and dry juvenile tarsometatarsi presented unfused metatarsals and bulkier and wider aspect than the adult ones. The dry femora presented a noticeable excavation between condyles, whereas the dry tarsometatarsi showed the absence of the proximal epiphysis. The femora, tibiotarsi and tarsometatarsi possessed different traits of immaturity, which differentially affect the morphology of the preserved bones during a taphonomic process.  相似文献   
2.
A closed complete mid‐diaphyseal spiral fracture of the left femur in a one‐year‐old donkey was treated with a 4.5 mm titanium locking compression plate distal femur (LCP‐DF)1. This plate was originally manufactured for human orthopaedics, primarily for femoral osteosynthesis. The LCP‐DF1 has a distal head plate that was advantageous in this case because the distal fragment was smaller. Post operative radiographs showed optimal femoral reconstruction and a callus was present 3 weeks after surgery. The donkey was sound at the walk and trot 2 months after surgery. Radiographs taken 5 months after surgery showed stable implants and complete healing without complications.  相似文献   
3.
OBJECTIVE: To evaluate the use of polyamide bands, manufactured for securing electrical cables, for repair of oblique femoral fractures in rabbits. STUDY DESIGN: Experimental study. ANIMALS: Twelve nulliparous, 21-25-week-old, California female rabbits. METHODS: Rabbits were divided into 3 groups (n=4) and studied for 14, 28, or 56 days. A Z-shaped mid-diaphyseal femoral osteotomy was repaired with a 2.5 mm intramedullary pin and a polyamide 6.6 cerclage band. Healing was evaluated at intervals by physical examination, limb use, femoral radiographs, and callus histology. RESULTS: Rabbits had early limb use with good wound healing. From the 1st day, movement of the hip and stifle joints was satisfactory. Radiographically, fractures were healed at 28 days. Histologically, there was no foreign body reaction and bone healing was normal. CONCLUSION: Nylon cerclage band application was accomplished easily, maintained reduction, and resulted in good healing and limb use. CLINICAL RELEVANCE: Sterilized nylon bands, manufactured for electrical use, can be used for cerclage in rabbits.  相似文献   
4.
OBJECTIVE: To evaluate the use of subdermal plexus skin flaps for closing defects after excision of cutaneous and subcutaneous tumors in dogs and to compare outcome of flaps secured with sutures and those secured with butyl-cyanoacrylate and intermittent sutures. STUDY DESIGN: Clinical study. ANIMALS: Fifteen dogs. METHODS: After excision of cutaneous or subcutaneous tumors the skin defect was reconstructed by random flaps based on the subdermal plexus. Flap skin edges were apposed with simple interrupted 4-0 monofilament nylon sutures (group 1; 5 dogs) or nylon sutures alternated with butyl-cyanoacrylate adhesive (group 2; 10 dogs). Flaps were evaluated every 48 hours when bandages were changed, until complete healing. RESULTS: Random flaps based on the subdermal plexus were effectively used to close wound defects; mean flap survival was 89%. Partial flap necrosis occurred in 4 dogs. Wound margins apposed with butyl-cyanoacrylate had thinner and more esthetic scars than sutured margins. CONCLUSION: Random flaps based on the subdermal plexus proved to be versatile for covering limb wounds after excision of cutaneous or subcutaneous tumors. Mean survival rate was comparable to that reported for axial pattern flaps. Butyl-cyanoacrylate adhesive was easy to apply, allowed accurate margin apposition with good cosmetic outcome and reduced sutures needed. CLINICAL RELEVANCE: Cyanoacrylate adhesive should be considered in lieu of suture closure to secure random skin flaps based on the subdermal plexus in dogs.  相似文献   
5.
OBJECTIVE: To describe 2 devices for improving stabilization of inadequately stabilized interlocking nail (ILN) repairs of the humerus, tibia, and femur in dogs and cats. STUDY DESIGN: Prospective study. ANIMALS: Twelve client-owned dogs and cats. METHODS: Two devices to further stabilize ILN repair of inadequately stabilized diaphyseal fractures were developed. Device 1 was an axial extension for the ILN that was connected to a conventional type I external skeletal fixator (ESF) with a short connecting bar. Device 2 had hybrid ILN bolt/ESF pins that were used to lock the ILN and serve as the pins for a type I ESF. Devices were used at the initial surgery when the stability of ILN repair was considered inadequate based on palpable fracture segment movement, insufficient medullary canal filling of the ILN at the fracture site, or when the ILN was used in a buttress mode. Outcome was obtained by recheck examinations, radiography, and telephone interview. RESULTS: Device 1 was applicable to fractures of the humerus and femur, but was not used for fractures of the tibia because the ILN extension would have interfered with the stifle. No gross loosening of the ILN/ESF extension connection to the ILN occurred. Device 2 was easily placed and used in the humerus, femur, and tibia. Device 2 allowed removal of the ILN interlock to one or both main fracture segments non-invasively. Clinically, both devices added stability compared with ILN repair alone. Both devices facilitated controlled destabilization of the fracture repair as healing progressed. Complications of pin tract infection, and premature hybrid bolt/ESF pin loosening resulting in premature ESF removal each occurred in 1 patient. Four of 28 hybrid ILN/ESF pins were grossly loose at 4- or 6-week postoperative recheck examinations. Outcomes were excellent (9), good (1), fair (1), and poor (1). CONCLUSIONS: Inadequately stabilized ILN repair of fractures can be stabilized by use of either device, both of which also permit controlled destabilization of the repair during healing. Device 2 can be used when non-invasive removal of the ILN interlock is desired during healing. CLINICAL RELEVANCE: These 2 devices should be considered as alternative methods for stabilization of inadequately stabilized ILN repairs in dogs and cats, or when controlled destabilization of an ILN fracture repair is desired.  相似文献   
6.
In mammals, long bones are formed by ossification of a cartilaginous mould during early stages of development, through the formation of structures called the primary ossification centre, the secondary ossification centres (SOCs) and the physeal cartilages (PCs). The PC is responsible for long bone growth. The morphology of the PC and the SOCs varies during different stages of femoral growth. In this respect, several details involving the process of murine femoral development are lacking. In the present study, a morphological characterization of femur development from the embryonic period to adulthood in mice was studied using micro‐computed tomography (micro‐CT). To achieve this aim, femora were collected at embryonic day (E) 14.5, E16.5 and E18.5 and at postnatal day (P)1, P7, P14, P35, P46 and P52. CT images were obtained using a micro‐CT scanner (X‐SkyScan 1172; Micro Photonics) and analysed using the micro‐CT 3D visualization software Mimics (Materialise NV, Leuven, Belgium) and NRecon (Micro Photonics). The results of the present study revealed that the femur and its PCs and SOCs undergo morphological changes during different stages of development, including changes in their shape as well as position and thickness. These changes may be due to the response of the femur to mechanical loads imposed by muscle surrounding the bone during these stages of development. The result of the present study is important to improve our knowledge related to ossification and growth patterns of mouse femur during development.  相似文献   
7.
黄贻涛  王艺磊 《水产学报》2013,37(6):830-839
同种移植炎症因子AIF-1 (allograft inflammatory factor 1,AIF-1)是一种由干扰素γ诱导的含有EF-hand结构域的钙离子结合蛋白,其功能主要是参与移植排斥、免疫炎症反应、自身炎性和非炎性的损伤等.首次克隆了杂色鲍AIF-1基因cDNA全序列,命名为HdAIF-1,其全长为942 bp,开放阅读框为456 bp,编码151个氨基酸.实时荧光定量PCR结果表明:HdAIF-1在杂色鲍各组织中均有表达,其中在血淋巴和鳃中表达量最高.高温应激下,HdAIF-1在鳃组织中各时相表达均显著上调,并在温度升至31℃时达到最高.而血淋巴和肝胰腺中HdAIF-1在高温应激前4个时相表达无显著差异,到了96 h均显著上调.缺氧应激下,HdAIF-1在血淋巴中表达变化没有显著差异,而鳃中24 h显著下调,192 h显著上调.副溶血弧菌感染实验表明HdAIF-1基因在感染后3、24和48 h均检测到HdAIF-1的表达量显著上调.高温和缺氧应激以及弧菌感染均显示HdAIF-1基因表达量发生显著变化,说明HdAIF-1可能作为免疫因子在杂色鲍应激等状况下发挥重要作用.  相似文献   
8.
An 18‐year‐old Warmblood stallion was presented for an acute onset nonweightbearing right hindlimb lameness following a mild lameness of 2 weeks' duration. Severe swelling was present in the right femoral area. Despite extensive diagnostic procedures, no definitive diagnosis could be made. Packed red cell volume was persistently low. The horse improved with supportive treatment and was discharged at the owner's request. The horse presented 4 days later for bleeding from a previously made incision on the lateral femoral area. Due to deterioration of his condition, the stallion was subjected to euthanasia. Diagnosis of disseminated haemangiosarcoma, affecting primarily the hindlimb musculature and leading to pathological fracture of the femur was made at necropsy and subsequent histopathology.  相似文献   
9.
To solve implant's looseness and subsidence, and to adapt for the requirement of custom-made hip endoprostheses' rapid automatic design and manufacture, a new method is presented for constituting the anisotropic and inhomogeneous model of proximal femur based on CT, CAD technology and finite element analysis during design of custom-made hip endoprostheses, Raw CT image data, 3-D modeling and finite element software is utilized to set up 3-D finite element model of proximal femur. The model is provided with anisotropy and inhomogeneity by self-developed specific software. The near true proximal femur model is structured and good biomechanics condition is provided for optimize design of custom-made hip endoprostheses. For simulating and analysing of proximal femur's structrue and material mechanics property, and determining stress ,strain and response after-operation under the action of physiological load more exactly, and supplying design of custom-made hip endoprostheses with data, the method can provide biomechanics condition for optimize design of custom-made hip prostheses.  相似文献   
10.
Injuries involving the femoral third trochanter are an uncommon but important source of equine lameness; however, clinical localization can be challenging. The purpose of this retrospective study was to describe ultrasonographic and scintigraphic findings in a group of horses with presumed third trochanter injury. Medical records of an equine referral hospital were searched from 2004–2014, and 20 horses met the inclusion criteria. Lesions consistent with third trochanter fracture were identified with ultrasound in 14/20 horses. Onset of lameness was acute (11), insidious (2), or unknown (1). All but one horse was lame at presentation, ranging from Grade 2–4/5. Ultrasound was the primary diagnostic modality in 5/14 horses with fragmentation, while scintigraphic findings of intense (3), moderate (5), and mild (1) increased radiopharmaceutical uptake (IRU) prompted ultrasonographic examinations in 9/14 fractured horses. A nondisplaced fracture was suspected in an additional horse with intense IRU and negative ultrasound findings. In the remaining five horses, imaging findings included only mild IRU. Lameness was localized to other regions in these cases. Six of 12 fractured horses with available outcome data were returned to function after a prolonged rehabilitation of 8–18 months. Scintigraphic findings helped to direct focused ultrasound exams in the majority of fracture cases. Horses with evidence of third trochanter fracture had similar clinical characteristics to that reported for pelvic fractures and authors therefore recommend ultrasonographic examination of both regions, especially when scintigraphy is unavailable. Prognosis for return to function in horses of the current study was less favorable than previously reported.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号