全文获取类型
收费全文 | 83篇 |
免费 | 0篇 |
专业分类
林业 | 1篇 |
农学 | 1篇 |
2篇 | |
综合类 | 5篇 |
农作物 | 2篇 |
水产渔业 | 6篇 |
畜牧兽医 | 62篇 |
植物保护 | 4篇 |
出版年
2012年 | 1篇 |
2011年 | 4篇 |
2010年 | 5篇 |
2009年 | 3篇 |
2008年 | 1篇 |
2007年 | 1篇 |
2006年 | 5篇 |
2005年 | 2篇 |
2001年 | 1篇 |
1998年 | 3篇 |
1997年 | 4篇 |
1996年 | 8篇 |
1995年 | 2篇 |
1994年 | 3篇 |
1992年 | 4篇 |
1991年 | 2篇 |
1989年 | 2篇 |
1987年 | 2篇 |
1986年 | 1篇 |
1985年 | 1篇 |
1984年 | 1篇 |
1981年 | 1篇 |
1971年 | 1篇 |
1963年 | 1篇 |
1959年 | 1篇 |
1958年 | 4篇 |
1957年 | 4篇 |
1956年 | 4篇 |
1955年 | 2篇 |
1954年 | 5篇 |
1953年 | 3篇 |
1951年 | 1篇 |
排序方式: 共有83条查询结果,搜索用时 140 毫秒
1.
SIMON R. PLATT J. FRASER MCCONNELL MARK BESTBIER 《Veterinary radiology & ultrasound》2006,47(1):78-82
A 4-year-old neutered female terrier-cross was evaluated for an acute onset of paraplegia. Utilizing magnetic resonance (MR) imaging, the cause of the neurologic deficits was determined to be a lumbar intervertebral disc extrusion. The MR study additionally demonstrated parenchymal hyperintensity on T2-weighted images and similarly located diffuse hypointensity on gradient echo images, cranial and caudal to the compressive extradural lesion. Hemorrhagic myelomalacia was suspected based on these MR characteristics, which was subsequently confirmed surgically and histopathologically. 相似文献
2.
LAUREL A. DEGERNES DVM Diplomate ABVP SIMON C. ROE BVSc PhD Diplomate ACVS C. FRANK ABRAMS Jr. PhD PE 《Veterinary surgery : VS》1998,27(4):301-306
Objective —To measure pullout strength of four pin types in avian humeri and tibiotarsi bones and to compare slow-speed power and hand insertion methods.
Study Design —Axial pin extraction was measured in vitro in avian bones.
Animal Population —Four cadaver red-tailed hawks and 12 live red-tailed hawks.
Methods —The pullout strength of four fixator pin designs was measured: smooth, negative profile threaded pins engaging one or two cortices and positive profile threaded pins. Part 1: Pins were placed in humeri and tibiotarsi after soft tissue removal. Part 2: Pins were placed in tibiotarsi in anesthetized hawks using slow-speed power or hand insertion.
Results —All threaded pins, regardless of pin design, had greater pullout strength than smooth pins in all parts of the study ( P < .0001). The cortices of tibiotarsi were thicker than the cortices of humeri ( P < .0001). There were few differences in pin pullout strengths between threaded pin types within or between bone groups. There were no differences between the pullout strength of pins placed by slow-speed power or by hand.
Conclusions —There is little advantage of one threaded pin type over another in avian humeri and tibiotarsi using currently available pin designs. There were few differences in pin pullout strengths between humeri and tibiotarsi bones. It is possible that the ease of hand insertion in thin cortices minimizes the potential for wobbling and therefore minimizes the difference between slow-speed drill and hand insertion methods.
Clinical Relevance —Threaded pins have superior bone holding strength in avian cortices and may be beneficial for use with external fixation devices in birds. 相似文献
Study Design —Axial pin extraction was measured in vitro in avian bones.
Animal Population —Four cadaver red-tailed hawks and 12 live red-tailed hawks.
Methods —The pullout strength of four fixator pin designs was measured: smooth, negative profile threaded pins engaging one or two cortices and positive profile threaded pins. Part 1: Pins were placed in humeri and tibiotarsi after soft tissue removal. Part 2: Pins were placed in tibiotarsi in anesthetized hawks using slow-speed power or hand insertion.
Results —All threaded pins, regardless of pin design, had greater pullout strength than smooth pins in all parts of the study ( P < .0001). The cortices of tibiotarsi were thicker than the cortices of humeri ( P < .0001). There were few differences in pin pullout strengths between threaded pin types within or between bone groups. There were no differences between the pullout strength of pins placed by slow-speed power or by hand.
Conclusions —There is little advantage of one threaded pin type over another in avian humeri and tibiotarsi using currently available pin designs. There were few differences in pin pullout strengths between humeri and tibiotarsi bones. It is possible that the ease of hand insertion in thin cortices minimizes the potential for wobbling and therefore minimizes the difference between slow-speed drill and hand insertion methods.
Clinical Relevance —Threaded pins have superior bone holding strength in avian cortices and may be beneficial for use with external fixation devices in birds. 相似文献
3.
JUAN M. MARTI LV Cert SAO MVM MRCVS SIMON C. ROE BVSc MS PhD Diplomate ACVS 《Veterinary surgery : VS》1998,27(5):423-428
Objective —To compare the insertional characteristics of external fixator pins with hollow ground (HG), modified HG, and trocar (T) points.
Study Design —An acute, in vitro biomechanical evaluation.
Sample Population—Thirteen radii from canine cadavers.
Methods —A total of 16 T-tipped and 16 HG-tipped pins were inserted into 8 canine radii. Ten pins of each modification of the HG tip (length of the cutting edge reduced by 0.127 mm and 0.254 mm, respectively) were inserted into another five radii. All pins were inserted with low-speed power drilling and 80 N drilling load. Differences between peak tip temperature, drilling energy, and pullout force were determined for each pin type at both diaphyseal and metaphyseal locations.
Results —HG-tipped pins showed a 40% lower tip temperature in diaphyseal bone, a 25% reduction in drilling energy in diaphyseal bone, and a reduction of pullout force in both diaphyseal (65%) and metaphyseal (50%) bone compared with T-tipped pins. HG 0.254-mm pins generated higher tip temperatures and had greater pullout than HG pins in diaphyseal bone.
Conclusions —The HG tip was a more efficient design; however, the reduction in pullout force suggests that, because a better hole was drilled, radial preload is reduced. Reduction of the cutting edge by 0.254 mm increased the pullout force but also increased the temperatures.
Clinical Relevance —Thermal and microstructural damage are reduced by the HG tip, but pin-bone interface stability is also compromised. The use of a tip with 0.254 mm reduction in the cutting edge may optimize the biological and mechanical factors at the pin-bone interface. 相似文献
Study Design —An acute, in vitro biomechanical evaluation.
Sample Population—Thirteen radii from canine cadavers.
Methods —A total of 16 T-tipped and 16 HG-tipped pins were inserted into 8 canine radii. Ten pins of each modification of the HG tip (length of the cutting edge reduced by 0.127 mm and 0.254 mm, respectively) were inserted into another five radii. All pins were inserted with low-speed power drilling and 80 N drilling load. Differences between peak tip temperature, drilling energy, and pullout force were determined for each pin type at both diaphyseal and metaphyseal locations.
Results —HG-tipped pins showed a 40% lower tip temperature in diaphyseal bone, a 25% reduction in drilling energy in diaphyseal bone, and a reduction of pullout force in both diaphyseal (65%) and metaphyseal (50%) bone compared with T-tipped pins. HG 0.254-mm pins generated higher tip temperatures and had greater pullout than HG pins in diaphyseal bone.
Conclusions —The HG tip was a more efficient design; however, the reduction in pullout force suggests that, because a better hole was drilled, radial preload is reduced. Reduction of the cutting edge by 0.254 mm increased the pullout force but also increased the temperatures.
Clinical Relevance —Thermal and microstructural damage are reduced by the HG tip, but pin-bone interface stability is also compromised. The use of a tip with 0.254 mm reduction in the cutting edge may optimize the biological and mechanical factors at the pin-bone interface. 相似文献
4.
Medial Plating for the Repair of Middle and Distal Diaphyseal Fractures of the Humerus in Dogs 总被引:1,自引:0,他引:1
JOSEPH HARARI ms dvm SIMON C. ROE bvsc mvst ANN L. JOHNSON dvm ms Dipiomateacvs CHARLES W. SMITH dvm ms Dipiomateacvs 《Veterinary surgery : VS》1986,15(1):45-48
Six middle and distal humeral shaft fractures in dogs were repaired by the application of a bone plate along the medial shaft of the humerus. In all animals, clinical and radiographic evidence of normal bone healing was observed. The bone plate and ancillary implants were removed from five dogs by 10 months. In none of the six dogs were any untoward effects of placing the bone plate along the medial shaft of the humerus detected nor were there any difficulties encountered with the medial humeral soft tissues. 相似文献
5.
SIMON C. ROE BVSc MVSt ANN L. JOHNSON dvm MS DiplomateACVS JOSEPH HARARI DVM MS 《Veterinary surgery : VS》1985,14(3):247-252
A technique using a third bar and guide clamp was developed to permit reduction and stabilization of distal limb fractures with full pins and two connecting bars, one on each side of the bone. The system uses only single Kirschner clamps. Four distal limb fractures were stabilized using this technique. Closed reduction was used in three dogs to avoid devitalization of fragments and avoid contamination of a closed fracture. The fracture site stability achieved with this configuration allowed early return to weight bearing and rapid bone healing. 相似文献
6.
7.
8.
Objective —To evaluate the suitability of epoxy putty for use as a connecting beam material in a free-form external skeletal fixator.
Design —Mechanical evaluation of beams and the pin-material interface of commonly used methacrylates and the proposed epoxy putty.
Procedure —The apparent modulus, bending strength, and toughness of 10 beams of three methacrylates (Technovit, APEF System, Bone Cement) and three epoxy putties (Oatey Epoxy Putty, All-Metals PowerPoxy, and Plumber's PowerPoxy) were determined in three-point bending. The shear strength of smooth and roughened-shaft pins embedded in the three methacrylates and the Oatey Epoxy Putty was determined by pull-out testing.
Results —The epoxy putties had similar strength, greater apparent modulus, and reduced toughness when compared with the methacrylates. The shear strength of the smooth pin interface with the Oatey Epoxy putty was greater than that with the methacrylates. The interface with roughened pins was much stronger than that with smooth pins for all materials tested.
Clinical Relevance —Epoxy putty is a suitable material for free-form external fixators. It is easy to handle, inexpensive, and has suitable setting times and mechanical properties. 相似文献
Design —Mechanical evaluation of beams and the pin-material interface of commonly used methacrylates and the proposed epoxy putty.
Procedure —The apparent modulus, bending strength, and toughness of 10 beams of three methacrylates (Technovit, APEF System, Bone Cement) and three epoxy putties (Oatey Epoxy Putty, All-Metals PowerPoxy, and Plumber's PowerPoxy) were determined in three-point bending. The shear strength of smooth and roughened-shaft pins embedded in the three methacrylates and the Oatey Epoxy Putty was determined by pull-out testing.
Results —The epoxy putties had similar strength, greater apparent modulus, and reduced toughness when compared with the methacrylates. The shear strength of the smooth pin interface with the Oatey Epoxy putty was greater than that with the methacrylates. The interface with roughened pins was much stronger than that with smooth pins for all materials tested.
Clinical Relevance —Epoxy putty is a suitable material for free-form external fixators. It is easy to handle, inexpensive, and has suitable setting times and mechanical properties. 相似文献
9.
10.