首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   16篇
  免费   0篇
  国内免费   1篇
林业   1篇
综合类   1篇
水产渔业   1篇
畜牧兽医   14篇
  2019年   1篇
  2011年   1篇
  2009年   4篇
  2008年   2篇
  2007年   3篇
  2006年   1篇
  1998年   1篇
  1996年   1篇
  1990年   1篇
  1978年   1篇
  1962年   1篇
排序方式: 共有17条查询结果,搜索用时 0 毫秒
1.
OKSBJERG  ERIK B. 《Forestry》1962,33(1):77-80
Drastic early pruning on young Norway spruce (Picea abies Karst.)on poor soils in Central Jutland resulted in an improvementin the colour of the needles and an increase in their nutrientcontent lasting, however, only a few months. Thereafter therewas a decrease in N and a return to the previous bad colourof the needles. The author offers an explanation for these changesand considers its bearing on any attempt to assess the contributionmade to stem increment by different branch whorls. He pointsout that the results of pruning may vary considerably accordingto whether single trees are pruned or all the trees in the plotare pruned.  相似文献   
2.
Seven isolated equine front limbs were used to establish the normal T1 relaxation time of equine superficial digital flexor tendon (SDFT), deep digital flexor tendon (DDFT), and suspensory ligament (SL) using magic angle magnetic resonance (MR) imaging. MR imaging of the metacarpi was performed with the limbs positioned at 55° (the magic angle) relative to the main magnetic field. Transverse spin‐echo proton density and inversion recovery images were acquired. T1 relaxation time was calculated based on ratios of signal intensity determined from the different pulse sequences. T1 relaxation times for SDFT, DDFT, and SL were 288 (±17), 244 (±14), and 349 (±16) ms, respectively. The difference in T1 values between SDFT, DDFT, and SL was statistically significant. T1 values of equine tendons can be determined with magic angle imaging on a clinical MR system using <10 min total scan time. The knowledge of the normal range of T1 values may be useful to identify horses with chronic tendinopathy, where based on the human literature, an increased T1 value may be expected.  相似文献   
3.
4.
经过严冬,当春天来临的时候,伴随着日照时间增长、光照度增力口,外界也变得温暖起来.但是对于北方地区而言,仍然需要消耗能源继续给温室加温.尤其是在夜晚,加温成本较白天增加75%至80%.  相似文献   
5.
A technique for regional delivery of contrast medium to the foot of the horse to increase the diagnostic utility of computed tomography (CT) for the characterization of soft tissue structures within the hoof capsule was developed. An intraarterial catheter was placed under ultrasound guidance into the medial palmar artery at the level of the carpus to facilitate a steady-state infusion of iodinated contrast medium. Two 5 mm collimated contiguous acquisition CT scans were performed in 10 horses without lameness or radiographic evidence of distal sesamoid bone degeneration. CT examination was performed before and during regional arterial infusion of iodinated contrast medium administered at a rate of 2 ml/s. Cross-sectional area and mean pre- and post-contrast attenuation of the deep digital flexor tendon and the collateral ligaments of the distal interphalangeal joint were quantified from CT images. Soft tissue anatomy of the foot was also qualitatively characterized from pre- and postcontrast images. Catheterization was successful and without complication in all horses. The evaluated tendons and ligaments were clearly visible and had a small (8-20 Hounsfield Unit) but significant (P < 0.05, paired t-test) increase in attenuation during the steady-state infusion of contrast medium. This study should enhance the diagnostic potential of CT by providing baseline quantitative data for comparison with horses affected with soft tissue injuries in the distal extremity causing lameness that is alleviated with a palmar digital nerve block.  相似文献   
6.
Objective— To document a novel technique to image the thoracic duct and its tributaries by contrast enhanced computed tomography (CT) lymphography.
Study Design— Clinical report.
Animals— Dogs (n=6) idiopathic chylothorax.
Methods— Ultrasonography was used to guide percutaneous injection of intestinal lymph nodes with nonionic iodinated contrast medium for preoperative CT lymphography of the thoracic duct in 6 dogs with chylothorax. Thoracic CT images were acquired immediately after contrast medium injection. All dogs had subtotal pericardectomy and thoracic duct ligation. Postoperative thoracic duct lymphography was performed in 3 dogs. Superficial cervical lymph node lymphography was performed in 2 dogs to determine cervical lymphatic contribution to thoracic effusions.
Results— Preoperative thoracic duct lymphography using this technique was successful in delineating the cisterna chyli, thoracic duct, and associated lymphatic vessels in all dogs. Immediate postoperative lymphography performed in 2 dogs revealed successful duct ligation in 1 dog and persistent lymphatic leakage in the other. A 1-month postoperative thoracic duct lymphogram performed in 1 dog revealed unsuccessful ligation or recannulation of 1 of 3 redundant vessels seen preoperatively.
Conclusion— Percutaneous CT lymphography results in excellent detection of the thoracic duct and abnormal thoracic duct drainage patterns both pre- and postoperatively. The contribution of superficial cervical lymph node drainage to reoccurrence of effusions can be evaluated.
Clinical Relevance— Percutaneous CT lymphography using ultrasound-guided contrast medium injection should be considered as an alternative to conventional open abdominal approaches to radiographic or CT lymphography.  相似文献   
7.
Bronchiectasis is diagnosed in humans using multiple computed tomography (CT) criteria, the most important being dilatation of the bronchi. The most widely used criterion for detection of bronchial dilatation is a bronchial lumen to pulmonary artery diameter (bronchoarterial [BA]) ratio >1.0. No studies have been performed to determine the BA ratio in normal dogs. Thoracic CT images of 24 dogs without clinical pulmonary disease were reviewed. The BA ratio of the lobar bronchi of the left cranial (cranial and caudal parts), right cranial, right middle, left caudal, and right caudal lung lobes was measured. The mean of the mean BA ratio for all dogs was 1.45±0.21 (99% confidence interval [CI]=1.34–1.56). The mean of the mean BA ratio as determined by lung lobe was 1.45±0.04 (99% CI=1.41–1.49). The range of individual BA ratios was 0.8–2.0. There was no significant difference in mean BA ratios as a function of lung lobe ( P =0.60). The BA ratio in these clinically normal dogs was consistent and may be a useful tool in evaluating for bronchiectasis on CT images. BA ratios >2.0 were not identified in this population, suggesting a threshold to differentiate normal from abnormal bronchi.  相似文献   
8.
This study was conducted to evaluate the effect of pilot hole (PH) diameter (0, 1.5, 2.0, 2.7, 3.1, 3.3, 3.5, and 3.7 mm) on the biomechanical and microstructural performance of positive-profile threaded external skeletal fixation pins (3.18 mm inner diameter, 3.97 mm outer diameter) using cadaveric canine tibiae. Eight pins per pilot hole diameter (four pins per bone) were used to assess differences in end-insertional torque and pin pull-out strength. Histological evaluation of eight bicortical pin tracts per pilot hole diameter was accomplished using computer-interfaced videomicroscopy on specimens processed using a bulk-staining technique. Compared with no predrill, use of 2.7 mm PH increased end-insertional torque and pull-out strength by 25% and 13.5%, respectively. No significant differences were observed in biomechanical variables for the PH diameter range of 2.0 to 3.1 mm. Compared with no predrill, use of a 3.1 mm PH increased thread area by 18%. Microfracturing around the threads decreased as PH diameter increased. Damage to the interface at the entry and exit sites of both near and far cortices also decreased as PH diameter increased. It was concluded that predrilling a PH whose diameter approximates, but does not exceed the inner diameter of the positive profile pin will not only improve initial pin stability compared with no predrilling, but it will also reduce microstructural damage that may lead to excessive bone resorption and premature pin loosening.  相似文献   
9.
Biomechanical models that compute the lengths and forces of muscle-tendon units are broadly applicable to the study of factors that promote injury and the planning and effects of orthopedic surgical procedures in equine athletes. A three-dimensional (3D) generic musculoskeletal model of the equine forelimb comprised of bony segment, muscle-tendon, and ligament information, was developed based on high-resolution computed tomographic (CT) and T1-weighted magnetic resonance (MR) images from an isolated forelimb of a Thoroughbred racehorse. Image fusion was achieved through coregistration of CT and MR images with an image analysis program (Analyze) by adjustment of the relative position and orientation of fiducial markers visible in both modalities until the mutual information between the images was maximized. 3D surfaces of the bones and origin/insertion sites, centroid paths and volumes of the muscle-tendon and ligamentous structures were obtained from the multimodal (CT/MR) images using semiautomated and manual segmentation combined with sagittal and transverse color-cryosection anatomic images obtained from three other cadaveric equine forelimbs. Once bony and soft-tissue structures were reconstructed in the same coordinate system, data were imported to a software package for interactive musculoskeletal modeling (SIMM). The combination of integrated CT and MR acquisitions and anatomical images provided an accurate and efficient means of generating a 3D model of the musculoskeletal structures of an average-sized equine adult horse.  相似文献   
10.
Radiation dose to personnel and low capacity X–ray equipment are obstacles to the optimal use of veterinary radiology. In order to find means to lower radiation dose and improve the quality of the radiographic image in veterinary radiology the authors have tested the so–called rare earth intensifying screens under experimental and clinical conditions. Of the basis of their findings they recommend the use of predominantly green light–emitting screen with lanthanum oxysulphide crystals activated with terbium, in combination with orthochromatic film. This combination was shown to give the best ratio image–screen noise. Considerable dose reduction was obtained with this system, and the image quality improved due to less blurring by motion.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号