首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   30篇
  免费   0篇
农学   4篇
基础科学   1篇
畜牧兽医   17篇
园艺   1篇
植物保护   7篇
  2015年   1篇
  2013年   2篇
  2012年   1篇
  2011年   2篇
  2009年   1篇
  2008年   2篇
  2006年   1篇
  1999年   2篇
  1994年   1篇
  1991年   1篇
  1985年   1篇
  1982年   3篇
  1981年   1篇
  1976年   4篇
  1974年   2篇
  1968年   1篇
  1966年   1篇
  1964年   1篇
  1963年   1篇
  1957年   1篇
排序方式: 共有30条查询结果,搜索用时 15 毫秒
1.
Worldwide, many nations impose blending of their transport fuels with biofuels, approximating 10% globally by 2020, to contribute to energy security while reducing emission of green house gasses (GHG). Food riots, scientific insights that question the GHG benefits and raised concern about the loss of biodiversity, have lead to the formulation by various governments of sustainability criteria for biofuels to comply with. In this paper, we assess this conditionality and argue that large-scale biofuels production will be unable to comply with these criteria in 2020, and can therefore not be qualified as sustainable.  相似文献   
2.
Summary

In this communication the test procedure is described for an indirect enzyme‐linked immunosorbent assay (ELISA) for the detection of antibodies against bovine leukosis virus (BLV). Test sera are incubated in polystyrene microtiter plates sensitized with a partly‐purified preparation of BLV. Bovine antibodies are detected with anti‐species immunoglobulin conjugated to the enzyme horseradish peroxidase, followed by the addition of the enzyme substrate.  相似文献   
3.
4.
Summary

An enzyme linked immunosorbent assay (ELISA) and the agar gel immunodiffusion test with bovine leukosis virus glycoprotein as antigen (AGIDT‐BLV gp) were further used to test 633 bovine sera for antibodies to BL V. Both tests detected the same number of sera positive (149) or negative (464) for antibodies. Nine sera were negative in the ELISA but found to be weakly positive (2 sera) or bending the control line (7) in the AGIDT‐BLV gp. On the other hand 11 sera were scored negative in the AGIDT‐BLV gp but were weakly positive (9 sera), positive (1), and strongly positive (I) in the ELISA. Both tests are used routinely in this Institute as they complement each other, specially if sera with low antibody titers are under investigation. It is concluded that ELISA can fully replace radioimmunoassays in the serodiagnosis of enzootic bovine leukosis.  相似文献   
5.
In the poultry industry, infections with avian influenza virus (AIV) can result in significant economic losses. The risk and the size of an outbreak might be restricted by vaccination of poultry. A vaccine that would be used for rapid intervention during an outbreak should be safe to use, highly effective after a single administration and be suitable for mass application. A vaccine that could be applied by spray or aerosol would be suitable for mass application, but respiratory applied inactivated influenza is poorly immunogenic and needs to be adjuvanted. We chose aluminum OH, chitosan, cholera toxin B subunit (CT-B), and Stimune as adjuvant for an aerosolized vaccine with inactivated H9N2. Each adjuvant was tested in two doses. None of the adjuvanted vaccines induced AIV-specific antibodies after single vaccination, measured 1 and 3 weeks after vaccination by aerosol, in contrast to the intramuscularly applied vaccine. The aerosolized vaccine did enter the chickens' respiratory tract as CT-B-specific serum antibodies were detected after 1 week in chickens vaccinated with the CT-B-adjuvanted vaccine. Chickens showed no adverse effects after the aerosol vaccination based on weight gain and clinical signs. The failure to detect AIV-specific antibodies might be due to the concentration of the inactivated virus.  相似文献   
6.
An indirect double antibody sandwich enzyme-linked immunosorbent assay (ELISA) was developed for the detection and titration of serum antibodies to bovine respiratory syncytial virus (BRSV). The ELISA was compared with a complement fixation (CF) test and a test for virus neutralising antibody in serum (virus neutralisation [VN] test). Testing sera collected in dairy herds revealed the closest correlation between the results of the ELISA and the CF test with respect to BRSV antibody titres. The VN test detected BRSV antibodies in a higher percentage of acute phase sera compared to the other two tests in field samples and in early bleedings of experimentally infected calves. However, the VN test was less effective in making a diagnosis of BRSV infections on the basis of a significant titre increase in paired sera. For this purpose the ELISA was found to be the most sensitive test.  相似文献   
7.
8.
9.
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号