全文获取类型
收费全文 | 52篇 |
免费 | 7篇 |
专业分类
农学 | 2篇 |
1篇 | |
综合类 | 6篇 |
水产渔业 | 1篇 |
畜牧兽医 | 43篇 |
植物保护 | 6篇 |
出版年
2023年 | 1篇 |
2021年 | 1篇 |
2020年 | 1篇 |
2019年 | 1篇 |
2018年 | 1篇 |
2017年 | 3篇 |
2016年 | 4篇 |
2015年 | 1篇 |
2014年 | 2篇 |
2013年 | 2篇 |
2012年 | 4篇 |
2011年 | 4篇 |
2010年 | 5篇 |
2009年 | 3篇 |
2008年 | 2篇 |
2007年 | 4篇 |
2006年 | 2篇 |
2005年 | 3篇 |
2004年 | 1篇 |
2003年 | 2篇 |
2002年 | 1篇 |
1998年 | 3篇 |
1997年 | 2篇 |
1992年 | 1篇 |
1989年 | 1篇 |
1979年 | 1篇 |
1975年 | 1篇 |
1969年 | 1篇 |
1968年 | 1篇 |
排序方式: 共有59条查询结果,搜索用时 15 毫秒
1.
2.
3.
Michailov GV Sereda MW Brinkmann BG Fischer TM Haug B Birchmeier C Role L Lai C Schwab MH Nave KA 《Science (New York, N.Y.)》2004,304(5671):700-703
In the nervous system of vertebrates, myelination is essential for rapid and accurate impulse conduction. Myelin thickness depends on axon fiber size. We use mutant and transgenic mouse lines to show that axonal Neuregulin-1 (Nrg1) signals information about axon size to Schwann cells. Reduced Nrg1 expression causes hypomyelination and reduced nerve conduction velocity. Neuronal overexpression of Nrg1 induces hypermyelination and demonstrates that Nrg1 type III is the responsible isoform. We suggest a model by which myelin-forming Schwann cells integrate axonal Nrg1 signals as a biochemical measure of axon size. 相似文献
4.
Measurements of electrical conductivity at high pressure and temperature were taken on the lower mantle phase magnesiowustite with varying Fe3+ content. Although previous measurements at atmospheric pressure suggest Fe2+-Fe3+ hopping (small polaron) as the dominant conductivity mechanism, the present experiments show a change in charge transport mechanism with temperature. The lower temperature measurements are consistent with small polaron conduction, but at higher temperatures, which are more applicable to the lower mantle, a large polaron mechanism is suggested. Because these mechanisms have different temperature and compositional dependencies, this transition has important implications for extrapolation to mantle conditions. 相似文献
5.
OBJECTIVE: To evaluate the efficacy of a percutaneously controlled hydraulic occluder (HO) in a rat model of gradual venous occlusion. STUDY DESIGN: Experimental study. ANIMALS: Ten male Sprague-Dawley rats. METHODS: HOs and perivascular transit time ultrasound flow probes were applied to the caudal vena cava (CVC). Occluders in group I rats (n=6) were gradually attenuated over 8 weeks, whereas occluders in group II rats (n=4) were not attenuated. Vena caval blood flow measurements were performed weekly in all rats for 8 weeks. After euthanasia, the CVC was evaluated grossly and by histopathology. RESULTS: Premature occlusion of the vena cava occurred during the 1st week in 3 rats (1 in group I, 2 in group II) because of kinking of the vena cava between the HO and the flow probe. For the remaining rats, mean blood flow in group I decreased significantly from 40.71 mL/min/kg at baseline to 4.68 mL/min/kg at 8 weeks (P=.0094, power=0.91). Group II rats maintained vena caval blood flow at all times during the study. Complete occlusion of the vena cava was confirmed at necropsy in all group I rats. CONCLUSIONS: Gradual occlusion of the CVC of rats was achieved with HOs over 8 weeks. This model is limited by the size of the experimental animals and comparatively large implants. CLINICAL RELEVANCE: HOs may provide a method for gradual occlusion of congenital portosystemic shunts. 相似文献
6.
Background Hinged circular external skeletal fixator constructs are used to perform sequential correction of angular limb deformities, often with resultant limb segment lengthening, via distraction osteogenesis. Although there are several reports describing the use of these constructs for correction of antebrachial deformities in dogs, there is little information regarding their use on other limb segments. This report describes the use of hinged circular fixator constructs for the correction of acquired crural deformities in three skeletally immature dogs. Case reports Two dogs had purely frontal plane deformities (one valgus, one varus) and the third dog had frontal (valgus) and sagittal (recurvatum) components to its deformity. At the time of long‐term evaluation, frontal plane angulation relative to the contralateral limb improved from 40° to 22° of valgus, 30° to 5° of valgus, and 20° to 1° of varus in the three individual dogs. Tibial length discrepancies of 12% and 22% that were initially present in two dogs were improved to 6% and 10%, respectively, of the contralateral tibial length at the time of final evaluation; both dogs had compensatory growth of the ipsilateral femur and all dogs had an excellent functional outcome. Conclusion These cases illustrate the value of using hinged circular fixator constructs for correction of crural angular deformities, particularly when length discrepancies of the tibia are present. 相似文献
7.
Objective— To evaluate outcome after closed fluoroscopic-assisted application of spinal arch external skeletal fixators in dogs with vertebral column injuries.
Study Design— Retrospective case series.
Animals— Dogs with traumatic vertebral column injuries (n=5).
Methods— Medical records of dogs with vertebral column fractures and/or luxations stabilized with spinal arch external skeletal fixator frames applied using a closed fluoroscopic-assisted technique were reviewed. Owners were contacted to obtain long-term clinical outcomes.
Results— Five dogs (age range, 6–72 months; weight, 10–54 kg) had traumatic vertebral column injuries stabilized with spinal arch external skeletal fixators applied in closed fashion. Injuries involved vertebral segments of the thoracolumbar junction, lumbar spine, and lumbosacral junction. Immediately postoperatively, 4 dogs had anatomic alignment of their vertebral fracture/luxation; 1 dog had 1 mm of vertebral canal height compromise. Time to fixator removal ranged from 65 to 282 days (141±87 days). All dogs had regained satisfactory neurologic function by 3 months. At long-term follow-up (range, 282–780 days; mean 445±190 days) all dogs were judged to have good to excellent return of function by their owners.
Conclusion— Successful closed fluoroscopic-assisted application of external skeletal fixators using spinal arches provided satisfactory reduction with few complications in 5 dogs. Return to function was judged to be good to excellent in all dogs at long-term evaluation.
Clinical Relevance— Closed fluoroscopic-assisted application of ESF using spinal arches provided satisfactory reduction and effective stabilization of spinal fractures with few complications and should be considered as a treatment approach. 相似文献
Study Design— Retrospective case series.
Animals— Dogs with traumatic vertebral column injuries (n=5).
Methods— Medical records of dogs with vertebral column fractures and/or luxations stabilized with spinal arch external skeletal fixator frames applied using a closed fluoroscopic-assisted technique were reviewed. Owners were contacted to obtain long-term clinical outcomes.
Results— Five dogs (age range, 6–72 months; weight, 10–54 kg) had traumatic vertebral column injuries stabilized with spinal arch external skeletal fixators applied in closed fashion. Injuries involved vertebral segments of the thoracolumbar junction, lumbar spine, and lumbosacral junction. Immediately postoperatively, 4 dogs had anatomic alignment of their vertebral fracture/luxation; 1 dog had 1 mm of vertebral canal height compromise. Time to fixator removal ranged from 65 to 282 days (141±87 days). All dogs had regained satisfactory neurologic function by 3 months. At long-term follow-up (range, 282–780 days; mean 445±190 days) all dogs were judged to have good to excellent return of function by their owners.
Conclusion— Successful closed fluoroscopic-assisted application of external skeletal fixators using spinal arches provided satisfactory reduction with few complications in 5 dogs. Return to function was judged to be good to excellent in all dogs at long-term evaluation.
Clinical Relevance— Closed fluoroscopic-assisted application of ESF using spinal arches provided satisfactory reduction and effective stabilization of spinal fractures with few complications and should be considered as a treatment approach. 相似文献
8.
SJ Glaser T Schulte-Herbruggen M Sieveking O Schedletzky NC Nielsen OW Sorensen C Griesinger 《Science (New York, N.Y.)》1998,280(5362):421-424
Experiments in coherent magnetic resonance, microwave, and optical spectroscopy control quantum-mechanical ensembles by guiding them from initial states toward target states by unitary transformation. Often, the coherences detected as signals are represented by a non-Hermitian operator. Hence, spectroscopic experiments, such as those used in nuclear magnetic resonance, correspond to unitary transformations between operators that in general are not Hermitian. A gradient-based systematic procedure for optimizing these transformations is described that finds the largest projection of a transformed initial operator onto the target operator and, thus, the maximum spectroscopic signal. This method can also be used in applied mathematics and control theory. 相似文献
9.
M Aksoy H Erdem F Hatipolu NC Lehimciolu O Akman K Özkan 《Reproduction in domestic animals》2009,44(1):156-160
This study was performed to describe a practical technique for ultrasound examination of the scrotal content of the rabbit. The scrotal content of normal rabbits and those with induced lesions (i.e. needle biopsy of the testis and epididymal ligation) were viewed using a portable scanner connected to a 5 or 7.5 MHz real time, B-mode linear array transducer. The effect of frequency (5 and 7.5 MHz), pad material placed under the testicle (rubber, plastic and carton) and the presence of a water sack between the probe and organ were examined to optimize the technique. The best image quality was obtained using a 5-MHz probe when the testicle was fixed on a rubber pad and covered by a water sack. Testicular parenchyma was imaged as homogeneous and moderately echoic. Caput and cauda epididymis were identified as homogeneous and less echoic compared with the testis parenchyma. Variations in the testicular echotexture that occur secondarily to epididymal ligation and testis biopsy could be screened readily. In conclusion, real-time ultrasonography, performed as described in this study, may provide a valuable tool to screen scrotal contents and to identify certain pathological conditions that affect fertility in the rabbit. 相似文献
10.