首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   72篇
  免费   13篇
综合类   6篇
水产渔业   1篇
畜牧兽医   78篇
  2021年   3篇
  2020年   1篇
  2019年   3篇
  2018年   1篇
  2017年   3篇
  2016年   5篇
  2015年   4篇
  2014年   2篇
  2013年   4篇
  2012年   5篇
  2011年   2篇
  2010年   2篇
  2009年   3篇
  2008年   4篇
  2007年   3篇
  2006年   5篇
  2005年   3篇
  2004年   5篇
  2003年   1篇
  2002年   4篇
  2001年   5篇
  2000年   3篇
  1999年   4篇
  1997年   1篇
  1996年   6篇
  1993年   1篇
  1992年   1篇
  1970年   1篇
排序方式: 共有85条查询结果,搜索用时 62 毫秒
1.
2.
3.
OBJECTIVE: To compare drilling, tapping, and screw-insertion torque, force, and time for the 4.5-mm AO and 6.5-mm Acutrak Plus (AP) bone screws, and to compare the mechanical shear strength and stiffness of a simulated complete lateral condylar fracture of the equine third metacarpal bone (MC3) stabilized with either an AO or AP screw. STUDY DESIGN: In vitro biomechanical assessment of screw-insertion variables, and shear failure tests of a bone-screw-stabilized simulated lateral condylar fracture. SAMPLE POPULATION: Eight pairs of cadaveric equine MC3s METHODS: Metacarpi were placed in a fixture and centered on a biaxial load cell in a materials-testing system to measure torque, compressive force, and time for drilling, tapping, and screw insertion. Standardized simulated lateral condylar fractures were stabilized by either an AO or AP screw and tested in shear until failure. A paired t test was used to assess differences between screws, with significance set at P < .05. RESULTS: Insertion and mechanical shear testing variables were comparable for AO and AP insertion equipment and screws. CONCLUSION: The 6.5-mm tapered AP screw can be inserted in equine third metacarpal condyles and is mechanically comparable with the 4.5-mm AO screw for fixation of a simulated lateral condylar fracture. CLINICAL RELEVANCE: Considering the comparable mechanical behavior, the potential for less-persistent soft-tissue irritation with the headless design, and the ability to achieve interfragmentary compression by inserting the screw in one hole drilled perpendicular to the fracture plane, the 6.5-mm tapered AP screw may be an attractive alternative for repair of incomplete lateral condylar fractures in horses.  相似文献   
4.
INDEPTH seismic reflection profiling shows that the decollement beneath which Indian lithosphere underthrusts the Himalaya extends at least 225 kilometers north of the Himalayan deformation front to a depth of approximately 50 kilometers. Prominent reflections appear at depths of 15 to 18 kilometers near where the decollement reflector apparently terminates. These reflections extend north of the Zangbo suture to the Damxung graben of the Tibet Plateau. Some of these reflections have locally anomalous amplitudes (bright spots) and coincident negative polarities implying that they are produced by fluids in the crust. The presence of geothermal activity and high heat flow in the regions of these reflections and the tectonic setting suggest that the bright spots mark granitic magmas derived by partial melting of the tectonically thickened crust.  相似文献   
5.
OBJECTIVE: To determine whether iatrogenic hemarthrosis of the metacarpophalangeal joint could be used as a model for temporary reversible joint pain in horses. ANIMALS: 8 adult horses. PROCEDURE: Each horse was evaluated on a treadmill before and after injection of 1 metacarpophalangeal joint with 10 mL of autogenous blood. Horses were evaluated subjectively and objectively by use of a computerized force measurement system at intervals until lameness abated. The mean force difference between injected and noninjected limbs at all time periods after injection was compared with the difference between limbs at baseline. From each horse, synovial fluid samples collected before and 24 hours and 30 days after injection were analyzed for total protein concentration and cell type and number. Venous blood samples were collected before and 6 and 24 hours after injection for assessment of plasma cortisol concentration. RESULTS: For 24 hours after injection, the mean force difference between injected and noninjected limbs was significantly increased over baseline. The greatest force difference was detected after 2 and 4 hours. Baseline and 24-hour force data were not significantly different. Compared with baseline values, synovial fluid protein concentration and nucleated cell and RBC counts were increased significantly at 24 hours after injection but were not different at 30 days after injection. No significant changes in plasma cortisol concentration were detected at any time point. CONCLUSIONS AND CLINICAL RELEVANCE: In horses, iatrogenic hemarthrosis of the metacarpophalangeal joint appears to induce temporary reversible lameness with a mild to moderate degree of synovitis.  相似文献   
6.
7.
OBJECTIVE: To compare mechanical properties and failure characteristics of 2 methods of fixation for repair of a transverse, midbody fracture of the proximal sesamoid bone (PSB): 4.5-mm AO cortical bone screw (AO) placed in lag fashion and 4/5-mm Acutrak (AT) self-compressing screw. STUDY DESIGN: An in vitro biomechanical evaluation of intact forelimb preparations and forelimb preparations with a simulated midbody PSB fracture stabilized by a bone screw. SAMPLE POPULATION: Sixteen paired and 8 unilateral cadaveric equine forelimbs. METHODS: A midbody transverse osteotomy was created in the medial PSB of bilateral forelimbs of 8 equine cadavers. The osteotomized PSB in 1 forelimb from each cadaver was repaired with an AO screw. The osteotomized PSB in each contralateral limb was repaired with an AT screw. Eight unilateral intact control limbs were also studied. Mechanical properties were determined from axial compression, single cycle to failure, load-deformation curves. Failure characteristics were determined by evaluation of video images and radiographs. RESULTS: No statistically significant differences were found between repair groups. Both AO and AT groups had significantly lower mechanical properties than intact limbs except for stiffness. CONCLUSION: AO and AT constructs were mechanically comparable when used to stabilize a simulated midbody fracture of the medial PSB. Both constructs were mechanically inferior to intact limbs. Clinical Relevance- The AT screw should be considered for clinical use because of the potential for less soft tissue impingement and superior biocompatibility compared with the stainless-steel AO screw. However, postoperative external coaptation is necessary to augment initial fracture stability for either fixation method, and to maintain a standing metacarpophalangeal joint dorsiflexion angle between 150 degrees and 155 degrees.  相似文献   
8.
Objective— To report use of a locking compression plate (LCP) for fetlock arthrodesis in Thoroughbred racehorses after catastrophic disruption of the suspensory apparatus.
Study Design— Retrospective case study.
Animals— Racing Thoroughbreds (n=6) with a catastrophic breakdown injury of the suspensory apparatus.
Methods— Medical records (2004–2006) of horses that had fetlock arthrodesis using an LCP were reviewed. Preoperative recorded variables were: age, gender, affected limb, injury type and occurrence, limb support used and time to surgery. Recorded surgical variables were: implants used and cost, surgery time, and anesthetic recovery method. Postoperative recorded variables included: treatment, physical status, complications, and outcome.
Results— Of 6 Thoroughbred racehorses that had LCP arthrodesis, 4 were sound for breeding purposes the next year and 2 horses were euthanatized (1 at 16 days, 1 at 68 days) because of proximal interphalangeal joint (PIJ) luxation. No surgical complications were associated with implant application. Postoperative complications were similar to those reported for other arthrodesis techniques.
Conclusions— LCP is a viable option for fetlock arthrodesis in Thoroughbred racehorses after catastrophic suspensory apparatus disruption.
Clinical Relevance— Adequate fetlock stability can be achieved with an LCP, and although the repair is likely more stable it is ∼3 times more expensive than using a limited contact dynamic compression plate (LC-DCP) with cortical screws.  相似文献   
9.
A female American saddlebred horse was presented for surgical correction of a possible pseudohermaphrodite condition. The horse had abnormal external genitalia and exhibited stallion-like behaviour. No evidence of uterine or ovarian tissue was identified on laparoscopic examination, but hypoplastic testicular-like tissue was removed, although this was found to contain no spermatogonia upon histopathological examination. A karyotype was performed and showed the normal chromosomal complement for a female horse (64,XX). Polymerase chain reaction to detect the SRY gene was negative in peripheral blood as well as the testicular-like tissue. This case represents the first report of an SRY negative XX-male sex reversal intersex phenotype, which is a potentially inherited condition, in an American saddlebred horse.  相似文献   
10.
OBJECTIVE: To document natural bacterial flora on the ventral aspect of the equine abdomen, to compare 2 preparation techniques, and to identify potential risk factors that may contribute to incisional drainage. DESIGN: Prospective study. ANIMALS: 53 horses undergoing exploratory celiotomy. PROCEDURE: Group-1 horses (n = 26) were prepared with povidone-iodine and alcohol. Group-2 horses (27) were prepared with a film-forming iodophor complex. Numbers of bacterial colony-forming units (CFU) were measured before and after surgical scrub, following skin closure, and after recovery from general anesthesia. Swab specimens to identify normal skin bacterial flora and potential pathogens were obtained by swabbing a 4 x 4-cm area. Variables that might affect incisional drainage were also investigated. RESULTS: For both techniques, there was a significant reduction in bacterial numbers after skin preparation. Incisional drainage was observed in 14 (26%) horses (8 group-1 and 6 group-2 horses). Preexisting dermatitis, poor intraoperative drape adherence, high number of bacterial CFU obtained after recovery from anesthesia, and high number of CFU obtained from the surgery room environment were the main risk factors associated with subsequent incisional drainage. Bacillus spp, nonhemolytic Staphylococcus spp, Micrococcus spp, Corynebacterium spp, Streptomyces spp, other nonenteric genera, and nonhemolytic Streptococcus spp were the most common isolates obtained before surgical scrub. CONCLUSIONS AND CLINICAL RELEVANCE: Both skin preparation techniques were equally effective in reducing numbers of bacterial CFU by 99%, and a significant difference was not found in incisional drainage rate between groups. Protection of the wound during recovery from anesthesia and the immediate postoperative period may reduce incisional drainage after abdominal surgery in horses.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号