The purpose of this study was to assess the cardiorespiratory and behavioral responses to the combination of medetomidine and tramadol (M-T) or butorphanol (M-B) in standing laparoscopic ovariectomy in horses. One ovary was removed under M-T and the contralateral ovary was removed under M-B with at least 4 weeks between operations at random. Horses were sedated using intravenous medetomidine (5 µg/kg) followed by tramadol (1 mg/kg) or butorphanol (10 µg/kg) after 5 min. Sedation was maintained through the repeated injection of medetomidine (1 µg/kg) and tramadol (0.4 mg/kg) or medetomidine (1 µg/kg) and butorphanol (4 µg/kg) every 15 min. Cardiorespiratory function and behavioral responses, including, sedation, ataxia, and analgesia, were assessed during the surgery. There were no significant differences in cardiorespiratory values and sedation and analgesia scores between M-T and M-B. Ataxia scores were significantly lower in M-T than in M-B. This result suggests that M-T could maintain smooth and stable standing surgery with minimal cardiorespiratory changes in horses.  相似文献   
2.
This study was performed to evaluate the sedative and analgesic effects of xylazine (X) and tramadol (T) intravenously (IV) administered to horses. Six thoroughbred saddle horses each received X (1.0 mg/kg), T (2.0 mg/kg), and a combination of XT (1.0 and 2.0 mg/kg, respectively) IV. Heart rate (HR), respiratory rate (RR), rectal temperature (RT), indirect arterial pressure (IAP), capillary refill time (CRT), sedation, and analgesia (using electrical stimulation and pinprick) were measured before and after drug administration. HR and RR significantly decreased from basal values with X and XT treatments, and significantly increased with T treatment (p < 0.05). RT and IAP also significantly increased with T treatment (p < 0.05). CRT did not change significantly with any treatments. The onset of sedation and analgesia were approximately 5 min after both X and XT treatments; however, the XT combination produced a longer duration of sedation and analgesia than X alone. Two horses in the XT treatment group displayed excited transient behavior within 5 min of drug administration. The results suggest that the XT combination is useful for sedation and analgesia in horses. However, careful monitoring for excited behavior shortly after administration is recommended.  相似文献   
3.
4.
5.
Echocardiographic detection of bovine cardiac diseases   总被引:2,自引:0,他引:2  
  相似文献   
6.
A laser bowel welding technique for dogs and cats was developed. The bowel was pinched using a special clamp having an opening on the body developed for this experiment (LW clamp). Using the 2 different types of contact probe (blunt tip: Laser Bipolar Dissector (LBD); sharp tip: Super Scalpel Dissector (SSD)), the laser passed through the hole in the LW clamp to cut the bowels, while at the same time, sealing the cut portion. The results obtained in this study showed that the optimum laser output using LBD was 6-10 W in dog and cat ileum, and 8-10 W in dog and cat colon. Optimum laser output using SSD was 6-8 W in dog ileum, 8-10 W in dog colon, 10 W in cat ileum and 6-8 W in cat colon. No marked differences were observed between ileum and colon when using either LBD or SSD. At the same power, burst pressure tended to be slightly higher with LBD than with SSD, although there were not significant differences between them. Histologically, complete sealing of the welded site was seen. Welding and cutting of bowel in dogs and cats was thus confirmed to be possible using the LW clamp in combination with LBD or SSD probes under a diode laser output of approximately 8 W for 50-80 s (400-640 J/cm). Thus, we can expect that this method is applicable to clinical veterinary medicine.  相似文献   
7.
This pilot study assessed the efficacy of 2 minimally invasive techniques for proximal interphalangeal (PIP) joint arthrodesis in horses. The PIP joints of both forelimbs (n = 6) were stabilized with locking compression plates (LCP) using a minimally invasive technique (LCP technique). Subsequently, for 1 randomly selected PIP joint of each horse, surgical drilling (SurD) was performed and tissue engineering (TE) was applied (LCP/SurD/TE technique). Minimally invasive PIP joint arthrodesis with LCP demonstrated low postoperative infection rates. Gross and histological evaluations revealed considerable destruction of the articular cartilage in the LCP/SurD/TE-treated joints. In contrast, almost no destruction of the cartilage was observed in the LCP-treated joints. Our results suggest that the LCP technique alone is not sufficient for PIP joint arthrodesis and that the LCP/SurD/TE technique may be useful for PIP joint arthrodesis in horses.  相似文献   
8.
Our objective was to compare the invasiveness of single-incision laparoscopic surgery (SILS) and multiport laparoscopic surgery (MLS) for ovariectomy in 5 standing healthy adult Thoroughbred mares. First, laparoscopic ovariectomy was performed by SILS or by MLS on the right paralumbar fossa region in a standing mare. One month after surgery, ovariectomy by the other method was performed on the left side. For surgery evaluation, the surgical time, length of incision, and amount of lidocaine used were recorded and compared between SILS and MLS. Physical examination (body temperature, heart rate, and respiration rate) and hematology (number of leukocytes and hematocrit) were performed before surgery and every day for 7 days after surgery. Similarly, the degrees of swelling, heat, pain, and incisional wound healing were evaluated (grades1-4). The length of incision and amount of local anesthetic for SILS were significantly less than those for MLS. Moreover, the scores for swelling, heat, and pain in the SILS group tended to be lower than those in the MLS group for several days after surgery. We concluded that SILS was less invasive than MLS and is therefore useful for ovariectomy in mares.  相似文献   
9.
10.