首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   12篇
  免费   2篇
畜牧兽医   14篇
  2017年   1篇
  2016年   1篇
  2015年   1篇
  2013年   4篇
  2012年   2篇
  2010年   3篇
  2008年   2篇
排序方式: 共有14条查询结果,搜索用时 17 毫秒
1.
Objective – To evaluate the tolerance of a continuous positive airway pressure (CPAP) mask in tranquilized dogs and compare PaO2 in arterial blood in dogs receiving oxygen with a regular face mask or CPAP mask set to maintain a pressure of 2.5 or 5 cm H2O. Design – Prospective, randomized clinical study. Setting – University teaching hospital. Animals – Sixteen client‐owned dogs without evidence of cardiopulmonary disease were studied. Interventions – Eight animals were randomly assigned to each of 2 treatment groups: group A received 2.5 cm H2O CPAP and group B received 5 cm H2O CPAP after first receiving oxygen (5 L/min) by a regular face mask. Animals were tranquilized with acepromazine 0.05 mg/kg, IV and morphine 0.2 mg/kg, IM. An arterial catheter was then placed to facilitate blood sampling for pHa, PaO2, and PaCO2 determinations before and after treatments. Direct mean arterial pressure, heart rate, respiratory rate, and temperature were also recorded after each treatment. Measurements and Main Results – CPAP administration was well tolerated by all animals. The mean arterial pressure, heart rate, respiratory rate, temperature, PaCO2, and pHa, did not differ at any time point between groups. Differences were seen in oxygenation; in group A, PaO2 significantly increased from a mean of 288.3±47.5 mm Hg with a standard mask to a mean of 390.3±65.5 mm Hg with the CPAP mask and in group B, PaO2 increased similarly from 325.0±70.5 to 425.2±63.4 mm Hg (P<0.05); no differences were detected between the 2 CPAP treatments. Conclusions – In healthy tranquilized dogs noninvasive CPAP is well tolerated and increases PaO2 above values obtained when using a regular face mask.  相似文献   
2.
Objective To evaluate the mydriatic efficacy of a neuromuscular blocking agent (rocuronium bromide) applied topically to only one eye of nocturnal birds of prey and to assess for any general and/or local adverse effects due to its use. Animal studied Twelve healthy adult tawny owls (Strix aluco) were randomly divided in two groups. Procedures Six birds (Group 1) received a single dose of 0.35 mg of rocuronium bromide. The second group of subjects (Group 2) received two doses of 0.35 mg of rocuronium bromide (total 0.70 mg/eye). In both groups, the curariform agent was instilled topically. Pupil diameter was measured with a pupillary gauge in 10 min intervals for a total of 100 min and then every 20 min for a total of 240 min. The assessment of the pupillary light reflex was performed using a standard light source during pupillary size recording. Results Maximal pupillary diameter was 11.5 ± 0.3 mm for Group 1 and 11.0 ± 0.6 mm for Group 2 and no statistically significant differences were detected among the two groups. The maximal pupillary diameter was achieved at T80 for Group 1, and at T60 for Group 2. A complete fundus examination was possible on all treated eyes of subjects of both groups. The drug did not cause any noticeable adverse effects in any of the examined birds. Conclusion Results of the present study suggest that a single topical administration of 0.35 mg of rocuronium bromide to the eyes of healthy tawny owls results in sufficient mydriasis to allow for a complete examination of the fundus.  相似文献   
3.
4.
5.
6.
ObjectiveTo evaluate the effectiveness of paravertebral lumbar plexus block combined with parasacral sciatic block to anesthetize one hind limb in awake dogs.Study designRandomized, controlled, blinded experimental study.AnimalsEight healthy mongrel dogs weighing 12.4 ± 4.5 kg and aged 7 ± 2.33 years.MethodsAfter sedation with medetomidine, dogs received B1: bupivacaine 0.25%, 0.2 mL kg?1, B2: bupivacaine 0.5%, 0.2 mL kg?1, B3: bupivacaine 0.25% 0.4 mL kg?1, P1: NaCl 0.2 mL kg?1, P2: NaCl 0.4 mL kg?1. The lumbosacral plexus was blocked through a paravertebral block of the fourth, fifth and sixth lumbar nerves combined with a parasacral block. The relevant nerves were located using a nerve stimulator and injections of each treatment were administered. Degree and durations of sensory blockade were determined through the response to a Halsted clamp pressure on the skin innervated by the saphenous/femoral and lateral cutaneous femoral nerves (lumbar dermatomes) and by the peroneal and tibial nerves. The degree and duration of motor blockade was assessed evaluating the ability to walk normally and proprioception.ResultsP1 and P2 treatments did not show any grade of sensory or motor blockade. The B2 treatment produced a higher degree of sensory blockade compared to B1 and B3 for both lumbar and sciatic dermatomes. There was no significant difference in the degree of sensory blockade comparing B1 to B3. The B2 treatment had greater motor blockade compared to B1 and B3. The duration of sensory and motor blockade was longer in B2 compared to B1 and B3.Conclusion and clinical relevanceWhen the nerve stimulator is used to perform the lumbosacral plexus block, the concentration of the bupivacaine has a more important role than the volume to produce a more solid and longer block.  相似文献   
7.
Objective To evaluate the endotracheal tube cuff pressure achieved by four different inflation methods. Study design Prospective clinical study. Animals Eighty client owned dogs. Methods After anaesthesia induction, endotracheal intubation was performed using plastic or silicone tubes. A clinician unaware of tube type inflated the cuff by simple digital palpation (method A), thereafter the cuff was deflated and inflated again by a second clinician who tried to reproduce a previously learned cuff pressure of between 19 and 24 mmHg (method B). During method C the cuff was inflated to the minimum occlusive volume at an airway pressure of 20 cm H2O, and in method D the cuff was incrementally deflated until an audible air leak could be heard from the oral cavity at an airway pressure of 25 cm H2O. For all the methods, an operator recorded the actual cuff pressure obtained using a manometer. Heart rate, respiratory rate and mean arterial pressure were monitored throughout the procedure. Results The mean inflation pressure for plastic tubes was 56 ± 28 mmHg for method A, 20 ± 9 mmHg for method B, 35 ± 32 mmHg for method C and 46 ± 39 mmHg for method D. Pressures using silicone tubes were significantly higher than for plastic tubes, the mean registered pressures being 79 ± 39, 33 ± 16, 77 ± 50 and 92 ± 56 mmHg for methods A, B, C and D. Conclusions and Clinical Relevance None of the methods evaluated in this study can be considered effective for inflating the endotracheal tube cuff to within the optimal range when using silicone tubes. Direct measurement of the cuff pressure with a manometer is therefore recommended.  相似文献   
8.

Objective

To evaluate intraoperative and postoperative efficacy of ultrasound (US)-guided femoral (FN) and obturator (ON) nerves block, in the iliopsoas muscle compartment (IPM), using an in-plane technique.

Study design

Anatomical research and randomized, prospective, ‘blinded’ clinical study.

Animals

Six dog cadavers and 20 client-owned dogs undergoing tibial plateau levelling osteotomy (TPLO) surgery.

Methods

In phase 1, anatomical dissections and US imaging of the IPM were performed to design an US-guided nerve block involving the FN and ON simultaneously. The technique was considered successful if new methylene blue solution injection (0.1 mL kg?1) stained FN–ON for ≥2 cm. In phase 2, the US-guided nerve block designed in phase 1, combined with US-guided sciatic nerve (ScN) block, was performed in 20 dogs undergoing TPLO surgery. Patients were assigned randomly to one of two treatment groups: ropivacaine 0.3% (R3, n = 10) and ropivacaine 0.5% (R5, n = 10) at a volume of 0.1 mL kg?1 for each nerve block. Intraoperative success rate (fentanyl requirement < 2.1 mcg kg?1 hour?1) and postoperative pain score [Short Form-Glasgow Composite Measure Pain Scale (SF-GCMPS) ≥ 5/20] were evaluated.

Results

In phase 1, the US image of FN–ON was detected between L6 and L7. In-plane needling technique produced a staining of >4 cm in six of six cases. No abdominal or epidural dye spread was found. In phase 2, median fentanyl infusion rates were 0.5 (0.0–0.9) μg kg?1 hour?1 for R3 and 0.6 (0.0–2.2) μg kg?1 hour?1 for R5. At 9 and 11 hours after the peripheral nerve blocks, an SF-GCMPS ≥ 5 was observed for R3 and R5, respectively.

Conclusions and clinical relevance

The US-guided FN–ON block in the IPM, using an in-plane technique, combined with US-guided ScN block, provided sufficient analgesia to minimize the use of fentanyl during TPLO surgery. A longer postoperative analgesia was observed in group R5 compared with R3.  相似文献   
9.
10.
ObjectiveTo describe a new approach to block the femoral nerve and to evaluate the distribution of a dye injected into the psoas compartment using a new femoral nerve block approach; to assess its clinical application, when combined with a sciatic nerve block, for surgical anaesthesia/analgesia of the pelvic limb in dogs.Study designProspective anatomical, research and clinical study.AnimalsTwo dog cadavers; two dogs that had to be euthanized for reasons unrelated to this study, and 15 dogs undergoing pelvic limb orthopaedic surgery.MethodsPhase 1: anatomical dissections were performed to determine a simple method to approach the femoral nerve within the psoas compartment. Phase 2: 0.1 mL kg?1 of a lidocaine-new methylene blue solution was injected bilaterally after successful electrolocation of the femoral nerve in two anaesthetized dogs. Colorant spread was evaluated through femoral nerve dissections after euthanasia. Phase 3: in 15 dogs undergoing pelvic limb orthopaedic surgery under light general anaesthesia with isoflurane, intra-operative analgesic effect (cardiovascular responses) and early post-operative pain score, of the novel femoral nerve block combined with a sciatic nerve block as the sole analgesic protocol, were evaluated.ResultsPhase 1: a needle inserted from the lateral aspect of the lumbar muscles, cranially to the iliac crest and with a 30–45° caudo-medial direction, reaches the femoral nerve in the caudal portion of the psoas compartment. Phase 2: Four femoral nerves were stained >2 cm. Phase 3: this novel lateral pre-iliac approach, combined with the sciatic nerve block, blunted the intra-operative cardiovascular response to surgical stimulation in 13 out of 15 anaesthetized dogs. In addition, rescue analgesia was not required in the early post-operative 2-hour period.Conclusion and clinical relevanceThe lateral pre-iliac femoral nerve block technique may provide adequate intra- and early post-operative pain relief in dogs undergoing pelvic limb surgery.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号