首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   17篇
  免费   0篇
农学   2篇
农作物   1篇
水产渔业   2篇
畜牧兽医   12篇
  2010年   4篇
  2009年   3篇
  2008年   2篇
  2007年   1篇
  1996年   2篇
  1988年   1篇
  1986年   1篇
  1976年   2篇
  1973年   1篇
排序方式: 共有17条查询结果,搜索用时 15 毫秒
1.
Objective— To determine the effects of clamp reuse for the Kirschner–Ehmer (KE); Securos; and the IMEX–SK clamp.
Study Design— Experimental bench test of mechanical properties.
Methods— Specially designed fixtures were used to mechanically test 18 clamps of each type with respect to 6 mechanical variables: fixator pin slippage, connecting bar slippage, fixator pin rotation, connecting bar rotation, and clockwise and counterclockwise clamp–bolt axis pivot. Each clamp was tested 6 times for each variable at 7.68 Nm of clamp–bolt tightening torque. Results were compared using repeated measures ANOVA.
Results— For the IMEX–SK clamp, a significant degradation in the force required to cause slippage was found for connecting bar slippage and fixator pin rotation; however, this clamp also had a significant increase in the force to initiate slippage for clockwise clamp–bolt axis pivot with reuse. The Securos clamp had significant degradation in connecting bar slippage, connecting bar rotation, and fixator pin rotation whereas the KE clamp had significant degradation in connecting bar slippage only.
Conclusions— All 3 external fixator clamp types degraded in 1 or more movement variables in their ability to resist motion with reuse. The IMEX and Securos clamps were more subject to degradation than the KE clamp and this may have clinical importance for fixator composite rigidity.
Clinical Relevance— Fracture-reduction stability is related to the ability to resist motion within a clamp. The unpredictable nature of degradation we found cautions against repeated use. Clinicians should consider reuse of external fixator clamps with the knowledge that repeated use degrades clamp mechanical performance.  相似文献   
2.
3.
The authors discuss the use of radiology in avian work, with particular reference to a series of thirty-six cases. Conditions diagnosed included fractures, arthritis and osteodystrophy and attention is drawn to the value of a suitable anaesthetic in such work. It is postulated that birds could prove useful models in biomedical research.  相似文献   
4.
Reasons for performing study: Inflammatory airway disease (IAD) is a nonseptic condition of the lower respiratory tract. Its negative impact on respiratory function has previously been described using either forced expiration or forced oscillations techniques. However, sedation or drug‐induced bronchoconstriction were usually required. The impulse oscillometry system (IOS) is a noninvasive and sensitive respiratory function test validated in horses, which could be useful to evaluate IAD‐affected horses without further procedures. Objectives: To determine the sensitivity of IOS in detecting alterations of the respiratory function in subclinically IAD‐affected horses without inducing bronchoprovocation and to characterise their respiratory impedance according to frequency for each respiratory phase. Methods: Pulmonary function was evaluated at rest by IOS in 34 Standardbred trotters. According to the cytology of bronchoalveolar lavage fluid (BALF), 19 horses were defined as IAD‐affected and 15 horses were used as control (CTL). Total respiratory resistance (Rrs) and reactance (Xrs) from 1–20 Hz as well as their inspiratory and expiratory components were compared between groups. Results: A significant increase of Rrs at the lower frequencies (R1–10 Hz) as well as a significant decrease of Xrs beyond 5 Hz (X5–20 Hz) was observed in IAD compared to CTL horses. IOS‐data was also significantly different between inspiration and expiration in IAD‐affected horses. In the whole population, both BALF eosinophil and mast cell counts were significantly correlated with IOS measurements. Conclusions: Functional respiratory impairment may be measured, even in the absence of clinical signs of disease. In IAD‐affected horses, the different parameters of respiratory function (Rrs or Xrs) may vary depending on the inflammatory cell profiles represented in BALF. Potential relevance: Impulse oscillometry could be used in a routine clinical setting as a noninvasive method for early detection of subclinical respiratory disease and of the results of treatment in horses.  相似文献   
5.
An unusual form of congenital intrahepatic portosystemic shunt was identified in a 3½-month-old female Labrador Retriever with neurologic signs. Ultrasonography and contrast-enhanced computed tomography were used to characterize the shunt morphology. An unusual, looping right-divisional shunt connected back to the portal vein that formed an ampula in the right-central portion of the liver. An irregularly shaped window-like opening connected the combined right-divisional loop and aneurysmal portal vein, and the caudal vena cava, while this vascular pool gradually fused more cranially. Imaging features of this complex vascular anomaly, which has not been previously reported, are presented.  相似文献   
6.
Objective— To report a technique for laser‐facilitated, minimally invasive proximal interphalangeal joint (PIJ) arthrodesis in horses. Study Design— Case series. Animals— Horses (n=6); 5 thoracic and 2 pelvic limb PIJ. Methods— PIJ osteoarthritis (OA) diagnosis was confirmed by radiography. A diode laser was used to apply 2000 J of energy to the joint followed by insertion of 3 parallel 5.5 mm screws in lag fashion through stab incisions to achieve PIJ arthrodesis. After anesthetic recovery, limbs were maintained in bandages (n=2) or bandage casts (5) for 3 weeks. Horses were allowed exercise or turnout by 3 months. Results— Three horses (4 limbs) were sound throughout follow‐up (6–18 months). One horse remained lame the 1st month, another had mild lameness at pasture at 6 weeks, and another had persistent low‐grade lameness and delayed joint fusion (1 year). Within 6 months, 5 horses were sound, 4 had radiographic evidence of successful joint fusion, and 5 had returned to intended use. Conclusion— Diode laser‐facilitated, 3 parallel screw arthrodesis for PIJ OA costs less and is associated with less pain compared with standard, open PIJ arthrodesis using 3 parallel screws inserted in lag fashion. Clinical Relevance— In horses with advanced PIJ OA, this technique appears to be a viable alternative for PIJ arthrodesis. Further study including characterization of the effects of the laser, ideal case selection indications, and optimal laser dose is indicated before this technique is recommended for routine PIJ arthrodesis.  相似文献   
7.
Reasons for performing study: Tetracycline compounds have been used to slow the progression of osteoarthritis (OA) and rheumatoid arthritis but the concentration of doxycycline attained in synovial fluid following oral, low‐dose administration has yet to be determined. Objective: To determine the concentration of doxycycline in synovial fluid following oral, low‐dose administration. Methods: Six mature horses received doxycycline (5 mg/kg bwt q. 12 h for 5 doses). Venous blood and synovial fluid samples were collected at t = 0, 0.25, 0.5, 1, 12, 24, 48 and 72 h. Doxycycline concentrations were measured using reverse phase high pressure liquid chromatography with ultraviolet detection. Results: Doxycycline concentrations at all time points after t = 0 were above the lower limit of quantification for the assay. Plasma concentrations of doxycycline were above 0.21 µg/ml at t = 0.5 h. The mean ± s.d. peak concentration (Cmax) of doxycycline in plasma was 0.37 ± 0.22 µg/ml and time to peak concentration was 0.54 ± 0.19 h. Synovial fluid concentrations of doxycycline were above 0.12 µg/ml 1 h after drug administration. The mean Cmax of doxycycline in the synovial fluid was 0.27 ± 0.10 µg/ml. The penetration factor of doxycycline from plasma into synovial fluid, as determined by a ratio of the area‐under‐the‐curve for synovial fluid:plasma during the sampling period, was 4.6. Potential relevance: Orally administered doxycycline distributes easily into synovial fluid with a penetration factor of 4.6. Terminal half‐life of the drug in synovial fluid was longer than in the plasma, indicating possible accumulation in this compartment. Further in vivo studies are warranted to define a medication protocol prior to routine clinical use of doxycycline for the treatment of OA.  相似文献   
8.
Objective— To report surgical treatment of traumatic lateral patellar luxation using trochlear block recession in an alpaca.
Study Design— Clinical case report.
Animals— Five-year-old female alpaca.
Methods— Grade IV/IV lateral, left patella luxation and mild femoropatellar joint effusion was identified by palpation and visual assessment, and confirmed by ultrasonography and radiographs. Trochlear block recession combined with lateral retinacular release and medial imbrication to restore patella function.
Results— Progressive improvement in weight bearing occurred during hospitalization (6 days) and at 3.5 weeks, no lameness was observed; radiographically, the patella was in normal anatomic alignment. At 15 months, there were no signs of lameness with unrestricted exercise and the alpaca had given birth to another cria.
Conclusions— In this alpaca with traumatic origin of the lateral patellar luxation and normal femoro-tibial alignment, a combination of retinacular imbrication, contralateral release, and trochlear block recession were successful for long-term treatment of lateral patellar luxation.
Clinical Relevance— Although trochlear block recession is most commonly performed in small animals, this technique may be useful in treatment of traumatic patellar luxations in camelids.  相似文献   
9.
10.
Objective— To compare the effects of hydrogen peroxide gas plasma (HPGP) and ethylene oxide (EO) sterilizations on the mechanical properties of nylon lines used for stabilization of the canine stifle. Secondarily, to compare the performance of crimped and knotted lines.
Study Design— In vitro mechanical evaluation.
Sample Population— Nonsterilized, EO- and HPGP-sterilized specimens of 36.3 kg test nylon leader line (NLL) and 57.8 kg test nylon fishing line (NFL).
Methods— Single strands and looped specimens of NLL or NFL were positioned on a material testing machine. To create looped specimens, NLL were crimped using the Securos system, and NFL were knotted, as used clinically. Elongation (%) and ultimate load (N) variables were studied.
Results— Elongation and ultimate load of NLL groups were not significantly different between EO and HPGP. For NFL, HPGP sterilization led to slightly greater elongation than EO in loops only. Ultimate load of NFL single strands was not significantly different between EO and HPGP, but was higher after HPGP compared with EO in NFL loops. All NLL groups had less elongation and ultimate load than NFL.
Conclusion— The effects of HPGP on NLL compared positively to EO, making HPGP an attractive alternative. As HPGP led to a slightly greater elongation of NFL than EO, the latter could be favored to sterilize NFL. Crimped NLL minimized elongation better than knotted NFL.
Clinical Relevance— Sterilization with HPGP seems a good alternative to EO for NLL. EO may be a better choice for NFL; however, it is difficult to judge the clinical relevance of this result. Crimped NLL minimizes elongation and may help reducing the recurrence of stifle instability postoperatively.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号