首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   19篇
  免费   2篇
林业   1篇
畜牧兽医   18篇
植物保护   2篇
  2019年   1篇
  2017年   1篇
  2016年   1篇
  2015年   1篇
  2014年   1篇
  2013年   1篇
  2011年   4篇
  2009年   1篇
  2008年   3篇
  2007年   1篇
  2006年   1篇
  2004年   2篇
  2002年   2篇
  2001年   1篇
排序方式: 共有21条查询结果,搜索用时 31 毫秒
1.
2.
Objective— To describe and evaluate a transiliac approach to the L7–S1 disk and intervertebral foramen in dogs.
Study Design— Cadaver study.
Animals— Fresh canine cadavers (n=10).
Methods— A craniolateral approach was made to each iliac wing of 10 fresh canine mixed breed cadavers. An 18 mm hole was drilled in a standardized position through the iliac wing. The musculature connected to the cranial aspects of the sacral wing was dissected and retracted cranially through this iliac window. Endoscopic exploration of the area was performed.
Results— The foramen and intervertebral disk were clearly observed in all specimens without iatrogenic injury of the L7 nerve branch. Access to the foramen was possible in 16 of 20 specimens without excision of the sacral wing; however, it was always partially excised to observe the intervertebral disk which lies more caudally and ventrally.
Conclusion— Transiliac approach to the lumbosacral joint allows direct exposure of the intervertebral disk and foramen through an iliac window. Endoscopic exploration provided good observation of the intervertebral disk and/or foramen.
Clinical Relevance— Transiliac approach could be used for lateral corpectomy and foraminotomy in dogs with degenerative lumbosacral stenosis caused by ventral or ventrolateral disk protrusion, foramen stenosis, or OCD of the L7–S1 joint. Clinical study will be necessary to evaluate the efficacy of this approach.  相似文献   
3.
4.
Abstract

Timber strength grading has become a major issue in the European Union during the last years, due to the introduction of the Eurocode 5 and all its related standards. Currently, the most performing strength grading machines are able to locally detect the boards’ knots sizes and positions and interpret this information through adapted grading models. The best lead to improve their accuracy seems to be the introduction of new information about the boards and adapt the mechanical model to take them in account. Small grain angle causes high reduction of clear wood's mechanical properties; local value of slope of grain appears to be of high interest. The aim of this study is to quantify the additional accuracy that grain angle information can bring to an optical scanner used as a strength grading machine. A specific grading model has been developed accordingly, and the results obtained for different machine/model/loading combinations are presented. These results show that slope of grain measurement can significantly improve the accuracy of the optical scanner, for both modulus of elasticity and modulus of rupture estimations.  相似文献   
5.
Hip dysplasia (HD) scores, based on the five grades, as defined by the Fédération Cynologique Internationale, were compared between anaesthetized (group 1, n = 3839) and non-sedated non-anaesthetized dogs (group 2, n = 1517). Each dog was radiographed in the standard ventro-dorsal hip joint extended position. Each radiograph was evaluated by the same reader blinded regarding the dog's status of anaesthesia. Results showed that there was a significant difference in hip dysplasia prevalence between group 1 (22%) compared with group 2 (9%) (P < 0.005). This difference was the result of a lower rate of hip-joint laxity assessment and the measurement of Norberg-Olsson angle <105 degrees in group 2 compared with group 1. The acetabular and femoral morphologies were not significantly different between the groups. The data confirm that the scoring of dogs for HD on standard radiographs with the hip joints extended is influenced by anaesthesia.  相似文献   
6.
In order to determine the prevalence of hip dysplasia (HD) from radiographs that were submitted for authorative grading, and its changes over the time in 31 breeds of dogs in France, a 14 year-retrospective study was conducted. Significant differences were observed between breeds, with HD prevalence ranging from 59.7% (Cane Corso) to 3.9% (Siberian Husky). When comparing the 1993-1999 with the 2000-2006 period in 15 breeds, a significant decrease in HD prevalence was detected in Berger Picard, Bernese Mountain dog, Briard, Gordon Setter, White Swiss Sheepdog and Rottweiler. Modifications observed in the other breeds were not statistically significant.  相似文献   
7.
The prevalence of rotation of the pelvis along its length axis was noted, as was the number of rotations towards the right or left hand side of the dog, on 7,012 conventional hip extended radiographs, which were sent for official screening. 29.8% of the radiographs showed a rotation the pelvis. The rotation was statistically more frequent towards the left hand side of the dog. The number of rejected radiographs for too important pelvis rotation was only 5.2%. The consequences of the pelvis rotation on the Norberg-Olsson angle, on the dorsal femoral head coverage, and in the aspect of cranial acetabular edge have to be taken into account when scoring the dog for hip dysplasia.  相似文献   
8.
OBJECTIVE: To compare the structural properties and the interfragmentary motion in ostectomized canine femurs stabilized with either an 8-mm interlocking nail system (IN) or a 10-hole dynamic compression broad plate (DCP). ANIMAL OR SAMPLE POPULATION: Ten pairs of adult canine femurs with a 25-mm mid-diaphyseal gap. METHODS: Bone specimens were divided into 2 groups (10 femurs each). Left femurs were stabilized with a DCP and 8 bicortical screws; right femurs were stabilized with an IN and 3 screws. Mechanical tests were performed in eccentric axial loading and in craniocaudal bending. The testing was first conducted nondestructively and then until breakage. Structural properties, ie, stiffness, yield limits, and failure limits, were determined. Interfragmentary motion was measured during nondestructive tests with the use of an optoelectronic device. Axial, transverse, and rotational motions were calculated. Mean values of stiffness, yield and failure limits, and axial and shear motions for each fixation method were compared using a paired t test within each group (P <.05). RESULTS: Mean (+/-SD) values of stiffness and failure limit were significantly higher for IN constructs than for DCP constructs in compression, while there was little difference in the results between each tested group in bending. Mean yield load values were significantly higher for IN than for DCP specimens in compression as well as in bending. The axial-motion analysis revealed significant differences between IN and DCP groups during bending tests only. The highest score of transverse motion at the gap was recorded during bending tests, and was higher for DCP than for IN specimens. There were insignificant differences between the two groups with regard to rotation around the diaphyseal axis. CONCLUSIONS AND CLINICAL RELEVANCE: Structural properties and interfragmentary shear motion analysis demonstrated a much higher rigidity in the IN-bone than in the DCP-bone constructs.  相似文献   
9.
This prospective study describes a simple method of combining laparoscopic ovariectomy and laparoscopic-assisted prophylactic gastropexy and determines the duration of surgery, complications, and long-term outcome including prevention of gastric dilatation-volvulus (GDV). Laparoscopic ovariectomy and laparoscopic-assisted gastropexy were performed on 26 sexually intact female dogs susceptible to GDV. The mean surgery time was 60.8 ± 12.4 min. No GDV episode was seen during the study period (mean follow-up: 5.2 ± 1.4 y). All dogs had an intact gastropexy attachment assessed by ultrasonography at 1 y. Post-operative complications were minor and owners were satisfied with the procedure. Combined laparoscopic ovariectomy and laparoscopic- assisted gastropexy appears to be a successful and low morbidity alternative procedure to both ovariectomy/ovariohysterectomy and gastropexy via open ventral-midline laparotomy.  相似文献   
10.
Objective: To report an endoscope‐assisted lateral approach to expose the intervertebral foramen and disk and perform lateral corpectomy of thoracolumbar disks in dogs. Study Design: Cadaver study. Animals: Fresh canine cadavers (n=6). Methods: A thoracic (T10–T11) and a lumbar (L3–L4) lateral approach were made on 6 fresh canine mixed breed cadavers. Through a limited skin incision, musculature was dissected and retracted using a neurosurgical self‐retaining retractor and lateral corpectomy performed. The approach and bone removal, both performed under endoscopic control, were assessed. Results: The foramen and intervertebral disk were clearly observed in all specimens without any iatrogenic injury of the ventral and dorsal nerve branches. Access to the foramen was possible in all specimens; in the thoracic area the head of the rib was always partially excised to observe the intervertebral disk medially. Lateral corpectomy was easily performed in all cadavers and spinal cord observation was good. Extension to foraminotomy or mini hemilaminectomy could easily be performed through the same limited approach. Conclusion: Endoscopic exploration provided a good viewing of the intervertebral disk and/or foramen. An endoscope‐assisted thoracolumbar lateral corpectomy could effectively be performed through a limited approach to the thoracolumbar disks and allowed good ventral spinal cord assessment.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号