首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   86篇
  免费   6篇
林业   5篇
  8篇
综合类   3篇
农作物   3篇
水产渔业   4篇
畜牧兽医   51篇
园艺   4篇
植物保护   14篇
  2022年   1篇
  2021年   2篇
  2020年   7篇
  2019年   2篇
  2018年   1篇
  2017年   4篇
  2016年   2篇
  2014年   1篇
  2013年   1篇
  2012年   4篇
  2011年   7篇
  2010年   1篇
  2009年   1篇
  2008年   8篇
  2007年   11篇
  2006年   8篇
  2005年   6篇
  2004年   4篇
  2003年   3篇
  2002年   9篇
  2001年   2篇
  2000年   1篇
  1998年   2篇
  1997年   1篇
  1992年   1篇
  1985年   1篇
  1981年   1篇
排序方式: 共有92条查询结果,搜索用时 15 毫秒
61.
62.
63.
In a survey of 900 Dalmatian dogs, brainstem auditory-evoked responses (BAER) and clinical observations were used to determine the incidence and sex distribution of bilateral and unilateral BAER abnormalities and their association with heterochromia iridis (HI). To assess the efficacy of BAER testing in guiding breeding programs, data from 749 dogs (subgroup A), considered to be a sample of the population at large, were compared with data from a subgroup (subgroup B; n = 151) in which selection of breeding stock had been based on BAER testing from the beginning of the 4-year survey. Brainstem auditory-evoked responses were elicited by applying click stimuli unilaterally, while applying a white noise masking sound to the contralateral ear. Under these conditions, BAER were either normal, unilaterally absent, or bilaterally absent. Dogs with bilaterally absent BAER were clinically deaf; dogs with unilaterally absent BAER were not clinically deaf but appeared dependent on their BAER-normal ears for their auditory-cued behavior. Dogs with unilaterally absent BAER often were misidentified as normal by uninformed observers. Among the 900 dogs, 648 (72.0%) were normal, 189 (21.0%) had unilateral absence of BAER, and 63 (7.0%) had bilateral absence of BAER or were clinically deaf and assumed to have bilaterally absent BAER (n = 4). Total incidence in the population sampled was assumed to be higher, because some bilaterally affected dogs that would have been members of subgroup A undoubtedly did not come to our attention. Among females, 24.0% were unilaterally abnormal and 8.2% were bilaterally abnormal whereas, among males, 17.8% were unilaterally abnormal and 5.7% were bilaterally abnormal.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   
64.
OBJECTIVE: To evaluate the effect of intravenous lidocaine on coughing and variations in heart rate (HR) and systolic arterial pressure (SAP) at endotracheal intubation in propofol-anaesthetized dogs. STUDY DESIGN: Prospective, randomized, blinded clinical study. ANIMALS: Eighty dogs, ASA grades I/II. METHODS: Dogs were randomly assigned to one of two treatments, with dogs in the lidocaine group receiving 1 mg kg(-1) lidocaine intravenously and those in the saline group receiving 0.05 mL kg(-1) saline intravenously before induction of anaesthesia with up to 6.5 mg kg(-1) propofol intravenously. An electrocardiogram was recorded continuously. Heart rate was calculated and SAP (using Doppler ultrasonic flow detection) was recorded at the following time points: pre-treatment, following lidocaine or saline administration, before and after intubation. The occurrence, number and strength of coughs were recorded. Systolic arterial pressure and HR were compared using one-sample t-tests to examine whether SAP and HR changed with test drug administration or following intubation. The number of coughs was compared between groups using t-tests. A cross tabulation and chi-square or Fisher's exact test was used to compare proportions of dogs that coughed and intensity of coughing in each group. The level of significance was set at p < 0.05. RESULTS: Heart rate did not change in either group. Systolic arterial blood pressure increased following intubation in both the lidocaine (p = 0.003) and saline groups (p = 0.001). There was no difference in the increase in SAP or in the number or intensity of coughs at intubation between groups. CONCLUSIONS AND CLINICAL RELEVANCE: Intravenous lidocaine had no effect on the occurrence or intensity of coughing or on changes in SAP at endotracheal intubation in dogs anaesthetized with propofol. The use of 1 mg kg(-1) lidocaine intravenously before intubation in dogs to attenuate cough and the pressor response was not supported.  相似文献   
65.
Objective – To compare blood pressure measurements obtained via ultrasonic Doppler flow monitor (DOP) and 2 oscillometric noninvasive blood pressure monitors (CAR and PAS) to invasive blood pressure (IBP) in hospitalized, conscious dogs with a range of blood pressures. Design – Prospective clinical study. Setting – University teaching hospital. Animals – Eleven client‐owned dogs aged between 4 months and 11.5 years (median 6 y), and weighing between 5.8 and 37.5 kg (median 30.2 kg). Interventions – Blood pressure measurement. Measurements and Main Results – Three consecutive measurements of systolic, diastolic, and mean arterial pressure (MAP) were recorded for each of the 3 indirect devices (only systolic for DOP), along with concurrent IBP measurements. The data were categorized into 3 groups: hypotensive (direct MAP<80 mm Hg), normotensive (80 mm Hg≤direct MAP≥100 mm Hg), and hypertensive (direct MAP>100 mm Hg). Each indirect method was compared with the corresponding direct arterial pressure using the Bland‐Altman method. Within the hypotensive group, each indirect method overestimated the corresponding IBP. Within the normotensive group all indirect systolic measurements and the PAS diastolic measurements underestimated the corresponding IBP. The remaining indirect measurements overestimated the corresponding IBP. Within the hypertensive group, DOP and CAR systolic measurements underestimated the corresponding IBP, and the remaining indirect measurements overestimated the corresponding IBP. In hypertensive dogs oscillometric systolic measurements were more accurate than MAP. In hypotensive dogs MAP measurements were more accurate than systolic measurements. All indirect measurements were most accurate in hypertensive dogs. Conclusions – The noninvasive blood pressure monitors in our study did not meet the validation standards set in human medicine. However, CAR diastolic and MAP measurements within the normotensive group, CAR MAP measurements within the hypertensive group, and PAS diastolic measurements in all groups were close to these standards. All indirect measurements showed greater bias during hypotension. Precision was poorer for all indirect systolic measurements than for MAP.  相似文献   
66.
The current microscopy method for identifying the Culicoides imicola Kieffer, 1913 species can be time and labour intensive. There is a need for the development of a rapid and quantitative tool to quantify the biting midges C. imicola ss in light trap catches. A reproducible and sensitive real-time polymerase chain reaction method that targets the internal transcribed spacer (ITS-1) of ribosomal DNA of C. imicola ss species was developed. This real-time PCR assay was first performed on 10-fold serial dilutions of purified plasmid DNA containing specific C. imicola ss ITS-1. It was then possible to construct standard curves with a high correlation coefficient (r2=0.99) in the range of 10(-2)-10(-8) ng of purified DNA. The performances of this PCR were evaluated in comparison with morphological determination on Culicoides trapped along the Mediterranean coastal mainland France. ROC statistical analysis was carried out using morphology as gold standard and the area under the ROC curve had a satisfactory value of 0.9752. The results indicated that this real-time PCR assay holds promise for monitoring C. imicola ss population in both surveillance and research programmes because of its good specificity (92%) and sensitivity (95%).  相似文献   
67.
Objective: To determine whether plasma from a heparinized hematocrit tube placed on a urine dipstick would accurately reflect (positive or negative) urine ketone results in diabetic dogs and cats. Design: Prospective study, 37 dogs and 43 cats, with a known history of diabetes or hyperglycemia, glucosuria, and symptoms of undiagnosed diabetes mellitus were tested. Setting: Veterinary Referral Hospital. Animals: Client owned dogs and cats. Interventions: None. Measurement and main results: Heparinized plasma and urine ketone results were recorded using urine reagent strips. Plasma dipstick results were compared to urine dipstick results as the standard. Results were recorded based on the color chart provided by the manufacturer. Two individuals were responsible for verifying the results of the colorimetric test. Test efficiency was 97% (sensitivity = 96%, specificity = 100%) for the canine population, 93% (sensitivity = 100%, specificity = 83%) for the feline population, and 95% (sensitivity = 98%, specificity = 91%) for the total population. Four of 80 animals were found to have discordant results (1 dog and 3 cats). Conclusion: Plasma from heparinized hematocrit tubes is clinically useful for detecting the presence or absence of ketonuria, and therefore ketosis, in diabetic dogs and cats using urine dipstick colorimetric methodology.  相似文献   
68.
OBJECTIVE: To compare measurements of body temperature obtained with auricular thermometers versus rectal thermometers in dogs with otitis externa. DESIGN: Prospective study. ANIMALS: 100 client-owned dogs: 50 with and 50 without clinical evidence of otitis externa. PROCEDURE: Dogs were evaluated for the presence of otitis externa on the basis of clinical signs, otoscopic examination, and cytologic evaluation of ear exudate. Auricular and rectal temperatures were obtained simultaneously in all dogs prior to and following ear examination. RESULTS: There was a high correlation between auricular and rectal temperatures in dogs with otitis externa both prior to and after ear manipulation. Significant differences were not detected in temperature measurements among dogs with different degrees of otitis externa. CONCLUSIONS AND CLINICAL RELEVANCE: Auricular temperature readings obtained by use of an auricular thermometer in dogs with otitis externa are accurate measurements of body temperature, compared with rectal temperature measurements. Temperature measurements are reliable before and after examination of the ear canal.  相似文献   
69.
Objective: To determine if a correlation exists among auricular, rectal and pulmonary artery (PA) temperatures in hypothermic dogs. Design: Prospective study. Setting: Angiography suite at a college of veterinary medicine. Animals: Sexually intact female research hounds (13.9–25.4 kg; n=8). Measurements and main results: Dogs were anesthetized for instrumentation with a percutaneously placed, thermistor‐tipped, PA catheter. Anesthesia was maintained until the core body temperature decreased to 36.6°C (97.8°F). Anesthesia was discontinued, and auricular and rectal temperatures were obtained every 15 minutes until the PA temperature reached 38.3°C (100.9°F). A strong correlation was noted among the 3 methods of temperature measurement (P<0.001; R≥0.846). No statistical difference was detected among measurement methods at baseline, the minimum temperature attained, nor the median temperature attained. However, at the maximum temperature attained, auricular measurements (37.7±0.4°C or 99.8±0.7°F) were lower than either the rectal (38.3±0.3°C or 100.9±0.5°F) or PA (38.3±0.3°C or 100.9±0.5°F) temperature measurements (P=0.001). Conclusion: There is a strong correlation among rectal, auricular and PA temperatures. Auricular temperature may be used to monitor core body temperature during postoperative rewarming; however, it might be slightly lower than core temperature as normothermia is reached.  相似文献   
70.
Giant clam populations have been over‐exploited throughout their range over the past decades for their meat and shells. Tridacna maxima, commonly known as the ‘small giant clam’, has remained relatively untargeted by fishers in areas where larger species occur (e.g. Tridacna squamosa), and high densities of the species are still observed on some isolated and enclosed reefs of the Central Pacific. However, it is unclear whether reported discrepancies in densities worldwide reflect differences in fishing pressure only or a combination of differences in exploitation levels and environmental forcing. We reviewed T. maxima surveys throughout its range to (i) identify patterns of density at global scale, site scale (e.g. island) and intrasite scale; (ii) discuss the influence of sampling method on density estimates; and (iii) identify the primary drivers of giant clam density along gradients of human pressure and natural forcing. We found 59 studies that reported density estimates for 172 sites across 26 countries in the Indo‐Pacific and Red Sea. At intrasite scale, densities were strongly dependent on sampling protocols and surveyed habitats. At site scale, we found close links between T. maxima density and human population per reef area, suggesting that isolated reefs where exploitation only recently started may be more vulnerable to stock collapse in the future. Density patterns were also found to vary significantly depending on reef type (e.g. atoll, island, continental coastline). We discuss how natural processes and fishing pressure may control population dynamics and densities among sites, and make recommendations for future research.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号