首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   166篇
  免费   16篇
林业   9篇
  22篇
综合类   11篇
农作物   17篇
水产渔业   3篇
畜牧兽医   107篇
园艺   2篇
植物保护   11篇
  2022年   7篇
  2021年   10篇
  2020年   6篇
  2019年   12篇
  2018年   7篇
  2017年   4篇
  2016年   4篇
  2015年   8篇
  2014年   6篇
  2013年   11篇
  2012年   8篇
  2011年   17篇
  2010年   5篇
  2009年   14篇
  2008年   16篇
  2007年   9篇
  2006年   6篇
  2005年   6篇
  2004年   8篇
  2003年   9篇
  2002年   6篇
  2000年   1篇
  1999年   2篇
排序方式: 共有182条查询结果,搜索用时 15 毫秒
1.
Motion artifact is an important limiting factor for abdominal magnetic resonance imaging (MRI) in veterinary patients. The purpose of this study was to determine the effects of pulse sequence on abdominal MRI diagnostic quality in dogs. Ten normal dogs were each scanned using 16 MRI pulse sequences. Sequences included breath‐holding sequences, respiratory navigation sequences, and traditional spin‐echo sequences. Four observers independently scored diagnostic quality for each sequence based on the appearance of specific organs, overall diagnostic quality, and degree of artifactual interference. Signal‐to‐noise ratio and contrast‐to‐noise ratio were also calculated for each sequence. The sequence with the highest overall mean diagnostic quality score was the dorsal T2 turbo spin echo (TSE) with fat saturation and breath‐holding. The sequence with the lowest mean diagnostic quality score was the dorsal T2 fast spin echo. The sequence with the highest signal‐to‐noise ratio for all evaluated organs was the sagittal T1 spin echo. Signal‐to‐noise and contrast‐to‐noise ratios did not correlate with subjective assessment of overall diagnostic quality for the majority of the sequences evaluated (P < 0.05). The three sequences considered to have the highest diagnostic quality for the cranial abdomen were the dorsal T2 TSE with fat saturation and breath‐hold, transverse T1 turbo fast low‐angle shot gradient echo with breath‐hold, and dorsal T2 half‐Fourier acquisition single shot TSE with respiratory navigation. These sequences had short acquisition times, yielded studies of similar diagnostic quality, provided complementary information, and are therefore recommended for routine canine abdominal MRI protocols.  相似文献   
2.
The imaging findings in two miniature schnauzers with acute necrotizing pancreatitis are described. Both dogs were treated previously for diabetes mellitus and hyperlipidemia. Vomiting, anorexia, and lethargy were observed in both dogs at presentation. Laboratory evaluations supportive of pancreatitis included left shift, abnormally high serum amylase and lipase activities, hypocalcemia, and abnormally high serum activities of liver enzymes. Sonographically, both dogs had diffusely enlarged hypoechoic pancreatic tissue with anechoic foci compatible with necrosis, abscessation, phlegmon, and pseudocysts formation. Contrast-enhanced computed tomography (CT) findings in both dogs were compatible with pancreatic necrosis. Dog 1 was managed medically for 11 days. Follow-up CT scan in this dog disclosed decreased pancreatic size and increased contrast enhancement compatible with partial resolution of pancreatitis.  相似文献   
3.
The expression pattern of TIR8 is conserved among vertebrates   总被引:1,自引:0,他引:1  
IL-1R/TLRs play an important role in the inflammatory responses. Their signaling pathway is tightly regulated to keep inflammation under control. The regulation involves both extracellular and intracellular mechanisms. TIR8, also known as SIGIRR (Single Immunoglobulin IL-1R-Related molecule), is an orphan receptor belonging to the IL-1R/TLRs super-family. Recent studies suggest its role in modulating the inflammatory response in the gastrointestinal tract in mice, acting as an IL-1 receptor family antagonist. We identified the sequence and analyzed the expression of TIR8 in a wide panel of organs and tissues in different animals. There was high homology of the cDNA sequence among human, mouse and the domestic species (74–85%). The pattern of expression of this receptor was similar in all the species examined (high levels in kidney and gastrointestinal tract) and similar to the human. These results demonstrate that TIR8 is conserved, in evolutionary terms, both with regard to sequence and pattern of expression, a finding consistent with a key function of this molecule in modulating inflammation in the gastrointestinal tract.  相似文献   
4.
Tiamulin and a number of macrolides were evaluated as to their ability in forming metabolic-intermediate (MI) complexes with cytochrome P450 in liver microsomes from rabbits bred for meat production. Complex formation, which occurred only in preparations where the expression of P450 3A was increased as the result of rifampicin pre-treatment and with different kinetics, was in the order tiamulin > erythromycin > TAO approximately roxithromycin approximately tylosin and did not take place with tilmicosin and spiramycin. Most of the tested compounds underwent an oxidative N-dealkylation and a good relationship could be found between the rate of N-dealkylase activity in induced preparations and the aptitude in generating MI complexes. Although the results from in vitro studies should be interpreted with caution, it is suggested that the potential for in vivo drug interactions also exists in the rabbit for tiamulin and for four out of the six tested macrolides.  相似文献   
5.
The purpose of this study was to (1) establish a technique for ultrasound-guided trans-splenic portal scintigraphy (TSPS) using 99mTcO4(-), (2) evaluate portal vein morphology, (3) compare the radiation exposures for TSPS vs. per-rectal portal scintigraphy (PRPS), and (4) compare the quality of numerical data from the TSPS vs. PRPS. Eight juvenile dogs underwent PRPS and TSPS (minimum of 48h between studies) after initial screening tests. PRPS was done according to established protocol using 425 +/- 36MBq (mean +/- SD) of 99mTcO4(-). TSPS was done with the dogs in right lateral recumbency over the gamma camera. 99mTcO4(-) (57 +/- 13.9 MBq) was injected into the spleen 1-2s following initiation of the dynamic acquisition. The frame rate was 4 frames/s for 5 min. There was significantly lower radioactivity of 99mTcO4(-) given and significantly higher total counts recorded in the liver and heart during the TSPS compared with PRPS. The total counts for the TSPS and PRPS were 7120 +/- 4386 and 830 +/- 523, respectively. Percent absorption from the spleen was 52.5 +/- 19.1% compared with 9.2 +/- 5.7% for the colon. Calculated transit time for the TSPS studies was 7 +/- 2.3s. In TSPS studies, the splenic and portal veins were clearly identified. Radiation exposure levels of the dogs were significantly lower following TSPS than after PRPS. TSPS appears superior to PRPS as a method to image the portal venous system representing a valid alternative diagnostic test for animals with suspected portosystemic shunts.  相似文献   
6.
Diagnosing right-to-left congenital cardiac shunts can be difficult. Cardiac catheterization and angiocardiography represent the traditional gold standard for diagnosis, but they are invasive. Nuclear scintigraphy using 99mTc-macroaggregated albumin (MAA) has been employed in humans as an alternate method of diagnosis. This study reviews eight dogs presented for evaluation of a suspect right-to-left cardiac shunt that were examined using 99mTc-MAA. In all, 2-4 mCi (74-148 MBq) of reduced particle 99mTc-MAA were injected IV in a cephalic vein and static images of the whole body, including right and left lateral, dorsal, and ventral views, were acquired for 60 s and stored into a 256 x 256 x 16 matrix. Shunt fractions were calculated. One dog with radiopharmaceutical distribution limited to the lungs did not have a shunt. Seven dogs had distribution of the radiopharmaceutical outside the pulmonary capillary bed, indicating bypassing of the pulmonary capillary circulation due to a right-to-left shunt. Four dogs had 99mTc-MAA within the brain. Three dogs that did not have brain uptake, but instead had a sharp cutoff of radioactivity at the level of the front limbs and neck, were diagnosed with reverse patent ductus arteriosus (PDA). The asymmetric distribution of the radiopharmaceutical is due to the location of the shunt, distal to the brachiocephalic trunk and left subclavian artery. Shunt fractions of dogs with extrapulmonary radioactivity ranged from 40% to 59%. Nuclear scintigraphy with 99mTc-MAA is a quick alternative method of diagnosing right-to-left cardiac shunts that permits quantification of shunt fraction. Distinguishing between reverse PDA and other right-to-left shunts may be possible based on the radiopharmaceutical distribution.  相似文献   
7.
8.
When the mare’s estrous cycle resumes in winter, the β-carotene content of hay is depleted. Sixty Italian trotter mares were randomly assigned to a Control or a Treated Group. Treated Group received 1g/d synthetic β-carotene for 15 days from parturition. Blood samples collected at parturition and on days 5, 10 and 15 after partum were analysed for β-carotene, vitamins A, progesterone, 17 β-estradiol, the energy parameters (glucose, cholesterol, NEFA), the protein profile (total protein, albumin, urea) and LDH. Some changes in these measures were attributable to treatment, which significantly affected β-carotene and 17 β-estradiol concentrations. A significant effect was also found on the resumption of estrous activity (χ2 test=P<0.052).  相似文献   
9.
Postprandial hyperlipemia is a well-defined risk factor for atherosclerosis. A reasonable contributing mechanism could involve the postprandial increase of plasma lipid hydroperoxides (LPO) affecting the oxidant/antioxidant balance and increasing the susceptibility of LDL to oxidation. Wine has been shown to prevent both these events. The present study was designed to investigate the effect of supplementing a meal with grape seed proanthocyanidins (the main phenolic antioxidant of red wine) on plasma postprandial oxidative stress. In two different sessions, 8 healthy volunteers consumed the same test meal rich in oxidized and oxidizable lipids without (control) or with 300 mg of a proanthocyanidin-rich grape seeds extract (GSE). Lipid hydroperoxide concentration, antioxidant status, and LDL resistance to oxidative modification were measured in postprandial plasma. The content of LPO in chylomicrons was 1.5-fold higher after the control meal than after the GSE-supplemented meal. Plasma LPO increased only after consumption of the control meal. The plasma antioxidant capacity increased in the postprandial phase only following the GSE supplemented meal. LDL isolated 3 h after the control meal tended to be more susceptible to oxidative modification (but the difference did not reach statistical significance). An opposite trend was observed following the GSE supplemented meal. In conclusion, the supplementation of a meal with GSE minimizes the postprandial oxidative stress by decreasing the oxidants and increasing the antioxidant levels in plasma, and, as a consequence, enhancing the resistance to oxidative modification of LDL.  相似文献   
10.
BackgroundPrevious studies evaluating the accuracy of computed tomography (CT) in detecting caudal vena cava (CVC) invasion by adrenal tumors (AT) used a binary system and did not evaluate for other vessels.ObjectiveTest a 7‐point scale CT grading system for accuracy in predicting vascular invasion and for repeatability among radiologists. Build a decision tree based on CT criteria to predict tumor type.MethodsRetrospective observational cross‐sectional case study. Abdominal CT studies were analyzed by 3 radiologists using a 7‐point CT grading scale for vascular invasion and by 1 radiologist for CT features of AT.AnimalsDogs with AT that underwent adrenalectomy and had pre‐ and postcontrast CT.ResultsNinety‐one dogs; 45 adrenocortical carcinomas (50%), 36 pheochromocytomas (40%), 9 adrenocortical adenomas (10%) and 1 unknown tumor. Carcinoma and pheochromocytoma differed in pre‐ and postcontrast attenuation, contralateral adrenal size, tumor thrombus short‐ and long‐axis, and tumor and thrombus mineralization. A decision tree was built based on these differences. Adenoma and malignant tumors differed in contour irregularity. Probability of vascular invasion was dependent on CT grading scale, and a large equivocal zone existed between 3 and 6 scores, lowering CT accuracy to detect vascular invasion. Radiologists'' agreement for detecting abnormalities (evaluated by chance‐corrected weighted kappa statistics) was excellent for CVC and good to moderate for other vessels. The quality of postcontrast CT study had a negative impact on radiologists'' performance and agreement.Conclusions and Clinical ImportanceFeatures of CT may help radiologists predict AT type and provide probabilistic information on vascular invasion.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号