首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   73篇
  免费   19篇
畜牧兽医   92篇
  2023年   1篇
  2021年   2篇
  2020年   4篇
  2019年   3篇
  2018年   9篇
  2017年   7篇
  2016年   7篇
  2015年   3篇
  2014年   5篇
  2013年   4篇
  2012年   8篇
  2011年   7篇
  2010年   4篇
  2009年   5篇
  2008年   4篇
  2007年   1篇
  2006年   3篇
  2005年   1篇
  2004年   2篇
  2002年   3篇
  2001年   2篇
  2000年   3篇
  1999年   2篇
  1998年   1篇
  1997年   1篇
排序方式: 共有92条查询结果,搜索用时 46 毫秒
41.
42.
ObjectiveTo compare two echocardiographic methods of measuring aortic diameter in short-axis projections.MethodsRight-parasternal short-axis 2-dimensional projections of the left atrium and aorta were obtained from dogs and cats undergoing routine cardiac evaluation. Two investigators measured the aortic valve linear dimension using 2 methods: along the commissure between the non-coronary and right-coronary cusps and along the commissure between the non-coronary and left-coronary cusps. Inter-observer and intra-observer variability and agreement were assessed by comparing blinded measurements with each method by 4 trained observers on a standardized set of images. Measurements were compared for agreement using the limits of agreement analysis. Variability between observers was compared by examining residuals and intraclass correlation.Results274 canine and 100 feline aortic valve images were measured in the first part of the study. One observer demonstrated slight proportional bias, while the other observer showed more variability (less agreement). When results were pooled for both investigators, no bias was identified, and 95% limits of agreement were ±10% of the mean measurement for both species. In the second part of the study, 106 images were measured. Intraobserver variability was <4% for all observers. Inter-observer agreement was very high. Individual bias was identified in some observers, but was considered clinically inconsequential. Normalized differences between the 2 methods of measurement were below ±15% of the measured value for all observers.ConclusionsOur results show sufficient agreement between two common methods used to measure aortic linear dimensions to suggest that these methods are interchangeable.  相似文献   
43.
44.
The purpose of this study was to review the medical records of dogs that were either suspected or known to have ingested large doses of pimobendan and to describe the clinical signs associated with pimobendan toxicosis. The database of Pet Poison Helpline, an animal poison control center located in Minneapolis, MN, was searched for cases involving pimobendan toxicosis from Nov 2004 to Apr 2010. In total, 98 cases were identified. Of those, seven dogs that ingested between 2.6 mg/kg and 21.3 mg/kg were selected for further evaluation. Clinical signs consisted of cardiovascular abnormalities, including severe tachycardia (4/7), hypotension (2/7), and hypertension (2/7). In two dogs, no clinical signs were seen. Despite a wide safety profile, large overdoses of pimobendan may present risks for individual pets. Prompt decontamination, including emesis induction and the administration of activated charcoal, is advised in the asymptomatic patient. Symptomatic and supportive care should include the use of IV fluid therapy to treat hypotension and address hydration requirements and blood pressure and electrocardiogram monitoring with high-dose toxicosis. Practitioners should be aware of the clinical signs associated with high-dose pimobendan toxicosis. Of the dogs reported herein, all were hospitalized, responded to supportive care, and survived to discharge within 24 hr of exposure.  相似文献   
45.
46.
47.
ObjectivesInterventional cardiac procedures are traditionally performed using fluoroscopy, or, more recently, transesophageal echocardiography (TEE). Neither modality is widely available to practicing cardiologists worldwide. We examined whether balloon valvuloplasty of pulmonic stenosis (PS) and transarterial occlusion of patent ductus arteriosus (PDA) in dogs could be performed safely with transthoracic echocardiography (TTE).AnimalsA prospective consecutive case series of 26 client-owned dogs with PS (n = 10) and PDA (n = 16).MethodsThe cardiovascular procedures were performed using TTE. Each dog was positioned on a standard echocardiography table in right lateral recumbency (dogs with PS) or left lateral recumbency (dogs with PDA). Guide wires, balloon catheters, Amplatz® Canine Ductal Occluder (ACDO) delivery sheaths, and ACDO were imaged by standard echocardiographic views optimized to allow visualization of the defects and devices.ResultsProcedures were performed successfully without major complications in 20 dogs. In 2 dogs (German shepherds) with Type III PDA, ACDO placement was unsuccessful; 2 other German Shepherds were excluded from the procedure because their ductal diameters, measured echocardiographically, exceeded the limits of the maximal ACDO size. Two dogs weighing ≤3.5 kg had suboptimal echocardiographic visualization of the PDA and were considered too small for safe ACDO deployment. All intravascular devices at the level of the heart and great vessels appeared hyperechoic on TTE image and could be clearly monitored and guided in real-time.ConclusionsWe have demonstrated that TTE monitoring can guide each step of pulmonic balloon valvuloplasty and PDA occlusion without fluoroscopy.  相似文献   
48.
49.
Two-dimensional (2D) echocardiography is the cornerstone of noninvasive evaluation of the cardiac patient, and often involves estimating left atrial (LA) size. However, 2D echocardiographic methods of estimating LA size have been inadequately described, and most reference intervals are based on M-mode echocardiographic measurements. We determined reference intervals for 4 different 2D echocardiographic methods of estimating LA size in adult (> or =9-month-old) dogs without cardiovascular disease. Thirty-six dogs, placed in right lateral recumbency, were examined by 2D echocardiography. The left atrium was measured at specific time points in the cardiac cycle. Measurement methods were LA diameter in short axis, LA diameter in long axis, LA circumference in short axis, and LA cross-sectional area in short axis. Comparisons of these LA dimensions to appropriate aortic dimensions provided body weight-independent estimates of LA size. We found strong associations of LA dimensions with body weight (r2 = .76-.88). Comparable body weight-independent 2D echocardiographic estimates of LA size in short axis exceeded historical M-mode reference intervals. These data provide echocardiographers with reference intervals for 2D echocardiographic estimates of LA size in adult dogs.  相似文献   
50.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号