首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   37篇
  免费   2篇
畜牧兽医   39篇
  1997年   1篇
  1989年   1篇
  1988年   3篇
  1986年   1篇
  1985年   8篇
  1984年   3篇
  1981年   1篇
  1979年   10篇
  1978年   5篇
  1977年   4篇
  1976年   1篇
  1975年   1篇
排序方式: 共有39条查询结果,搜索用时 31 毫秒
31.
Arteriography in ponies with Strongylus vulgaris arteritis.   总被引:1,自引:1,他引:0       下载免费PDF全文
Radiographs of the aorta and abdominal arteries were obtained from a normal anesthetized pony following catheterization of a femoral artery for nonselective, semiselective or selective arteriography. The arteries had smooth borders and regular diameters and the branches of the cranial mesenteric artery could be followed distally on the angiogram through to the smaller branches proximal to the bowel wall. Following arteriography, the pony walked normally and there were minimal alterations of the levels of serum muscle enzymes and blood lactate. The procedures for arteriography were repeated in three days. At that time the femoral artery was patent and satisfactory angiograms were obtained. Similiarly, radiographs were obtained from two ponies artificially infected with Strongylus vulgaris. The cranial msenteric artery and some of its branches, the right renal artery and segments of the aorta had irregular borders and were enlarged. Branches of the cranial mesenteric artery could not be followed distally because the flow of the contrast material was blocked. Following the above procedures, euthanasia of all ponies was expedited and the findings of arteritis, thrombosis and dilatation of arteries at necropsy compared favorably with interpretations from the radiographs. At least in the pony, arteriography can be a valuable research and diagnostic tool for the demonstration of lesions associated with verminous arteritis.  相似文献   
32.
The use of capacitively coupled low-voltage signals for stimulation of osteogenesis has been reported in a variety of animal models. Electrically induced osteogenesis was investigated with a capacitively coupled electric field on a radius (distal-lateral orientation) osteotomy model, in conjunction with internal fixation and postoperative loading. Twelve adult horses of either sex were allotted to 2 groups of 6; 1 group was given electrical stimulation and the other served as controls. A low-voltage high-frequency capacitively coupled electrical signal was locally and continuously applied to the electrically stimulated group for 60 days through external, bare stainless steel surface electrodes which were placed on the skin in circuit with a small, portable power source. Harness compatibility and stimulator and battery durability were excellent. However, stainless steel electrodes required a rigid maintenance schedule to maintain consistent current levels. Synovial fluid evaluation demonstrated intra-articular inflammation (decreased viscosity, hyaluronic acid, and increased protein concentration) 1 week postoperatively that generally improved during subsequent weeks and no distinction between groups was observed at 60 days. Radiographically, there was no difference in the appearance of the healing process of control and that of stimulated horses during the 60 days. Angiography showed bridging blood vessels in both groups. Uptake of a bone seeking radiopharmaceutical peaked at 3 weeks in both groups and was 1.92 +/- 0.6 cps/pixel/mCi and 1.26 +/- 0.40 csp/pixel/mCi for control and stimulated horses, respectively. At any given observation period, uptake in the lesion area was greater in the control group. Ultimate strengths of trabecular bone in 60-day control radii and stimulated radii were 12.64 +/- 3.013 and 9.60 +/- 3.95 MN/m2, and the flexural moduli of elasticity were 698.0 +/- 423 and 402.0 +/- 523 MN/m2, respectively. Porosity index was similar for all specimens. Gross, histologic, and microradiographic evaluations indicated that controls healed more efficiently than stimulated horses. A capacitively coupled applied voltage of 2.2 V RMS (mean) producing a current of 17.32 mA (mean) did not stimulate sufficient bone production in a metaphyseal osteotomy model to affect the mechanical properties of the bone or accelerate the healing process.  相似文献   
33.
The effect of a 20-microA direct-current implantable bone growth stimulator (BGS) on bone production with a "gap healing" model in the horse was evaluated. The right and left 4th metatarsal bones (Mt-4) were used in 7 adult horses to create the "gap healing" model. A 4-mm section of the Mt-4 bone was resected bilaterally in each horse. The BGS was surgically placed into the 7 left Mt-4 defects. The 7 right Mt-4 defects served as controls. Six horses survived the 16-week experimental period. Signs of pain, decreased range of limb motion, or lameness was not observed in any animal during the 16 weeks. None of the animals showed complete healing radiographically. Four stimulated sites showed less periosteal reaction and 2 showed greater reaction than the 6 controls. The greatest amount of periosteal reaction or bone resorption was seen around the screws and plates in both groups. Uptakes of 99mTc-MDP in counts/pixel for control sites and stimulated sites were 7.90 and 8.25 in the "gap defect" and 5.19 and 5.06 in the areas adjacent to the gap defect. The ratio of uptake between the gap defect and adjacent area was 1.5 and 1.58 respectively. Biocompatability of the BGS was excellent; however, 1 horse had a broken cathode wire 5 cm from the generator capsule at 6 weeks. All polyethylene cathode sheaths were fluid filled at 16 weeks. The average mineralization rates were 1.57 +/- 0.34, 1.71 +/- 0.28 mm/day and bone formation activity was 0.0182 +/- 0.171, and 0.0168 +/- 0.0149 mm2/day for control limbs and stimulated limbs, respectively. There was no significant difference between groups in any of the histomorphometric values measured. Direct current (20 microA) did not increase bone production in this experiment. Methods to objectively evaluate electrically induced osteogenesis and a "gap defect" model for BGS research on the horse are discussed. The results provide a basis for additional research on electrical stimulation of fractures in the horse and for dose-response studies.  相似文献   
34.
35.
Over an 8-year period, 9 horses with septic pedal osteitis were admitted to the New York State College of Veterinary Medicine. Septic pedal osteitis was defined by the presence of purulent exudate combined with radiographic evidence of lysis of the distal phalanx. The condition described involved only the distal phalanx, the laminae and hoofwall, and the soft tissues of the sole. Treatment included curettage and removal of the affected portion of the distal phalanx through a ventral approach to the foot, combined with systemic administration of antibodies. Of the 9 horses, 7 returned to soundness and original function within 12 weeks after surgery. During the early postoperative period, 2 horses died from causes unrelated to the surgery or to septic pedal osteitis.  相似文献   
36.
37.
A delayed union metacarpal stress fracture was repaired in a horse, using lag-screw fixation in conjunction with dc electrical stimulation. Twelve weeks after surgery, radiographic and scintigraphic evaluations revealed that the fracture line was not discernible and that there was a decrease in radiopharmaceutic uptake, as compared with that in previous bone imaging studies. In this horse, DC stimulation of a delayed union stress fracture in a bone resulted in a healing pattern similar to that in human beings with delayed union fractures when treated with electrical stimulation.  相似文献   
38.
Equine radiology--the pastern and foot   总被引:1,自引:0,他引:1  
  相似文献   
39.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号