Study Design —The maximum insertion torque of the cannulated and standard cortex screw systems were compared with the ultimate torsional strengths of the equipment. Pullout strength and ultimate tensile load of cannulated and standard cortex screws were also determined.
Sample Population—Paired equine cadaver third metacarpal and third carpal bones.
Methods —Maximum insertion torque and ultimate torsional strengths were determined by using an axial-torsional, servohydraulic materials testing system and a hand-held torquometer. Pullout tests were performed by using a servohydraulic materials testing system.
Results —Maximum insertion torque of all cannulated instrumentation was less than ultimate torsional strength at all locations ( P < .05). Maximum insertion torques of cannulated taps and screws were greater than for standard taps and screws in the third carpal bone ( P < .002). Pullout strength of the cannulated screws was less than the standard cortex screws at all sites ( P < .001). Cannulated screws broke before bone failure in all but one bone specimen. Conclusions—The risk of cannulated instrument or screw failure during insertion into bone is theoretically low. The relatively low pullout strength of the cannulated screws implies that the interfragmentary compression achievable is likely to be less than with standard cortex screws. Clinical Relevance—The relatively low pullout strength of the cannulated screw suggests that its risk of failure during fracture repair is greater than with the standard cortex screw. 相似文献
Pronounced tachycardia, hypotension and sweating accompanied the intravenous infusion of isoxsuprine. The 3 horses treated with isoxsuprine following the induction of laminitis showed a more rapid improvement in soundness than horses receiving saline placebos. No horse developed rotation of the third phalanx in response to the diet Nuclear scintigraphy indicated that blood perfusion patterns within the hoof of laminitic horses altered with isoxsuprine therapy, but an overall increase or decrease in perfusion was not apparent. Alterations in serum enzyme and electrolyte profiles with the onset of laminitis generally concurred with findings previously reported for this model of the disease. No change in coagulation profiles accompanied the onset of laminitis or isoxsuprine administration. Blood gas analysis indicated an increase in median palmar vein oxygen partial pressure (PO2) levels with onset of laminitis. A concurrent decrease in the median palmar arteriovenous oxygen partial pressure difference (AVO2) was significant at the P<0.01 level. There was no difference in median palmar vein PO2 values between thoseanimals receiving isoxsuprine and those receiving saline placebo therapy. Results of the trialindicated that isoxsuprine may be beneficial in the treatment of acute laminitis. Further controlled studies are appropriate. 相似文献