首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   193篇
  免费   0篇
  国内免费   2篇
林业   3篇
基础科学   1篇
  19篇
综合类   3篇
农作物   3篇
水产渔业   28篇
畜牧兽医   127篇
植物保护   11篇
  2022年   13篇
  2021年   22篇
  2020年   4篇
  2019年   2篇
  2017年   1篇
  2016年   4篇
  2015年   16篇
  2014年   13篇
  2013年   10篇
  2012年   6篇
  2011年   10篇
  2010年   5篇
  2009年   6篇
  2008年   15篇
  2007年   6篇
  2006年   7篇
  2005年   7篇
  2004年   9篇
  2003年   11篇
  2002年   14篇
  2001年   6篇
  2000年   2篇
  1997年   1篇
  1996年   1篇
  1995年   1篇
  1994年   1篇
  1993年   1篇
  1953年   1篇
排序方式: 共有195条查询结果,搜索用时 15 毫秒
101.
102.
103.
104.
105.
106.
The aims of studies were to estimate the withdrawal period of antibiotic from milk after the intramammary infusion of cefazolin sodium (CEZ) in cows with difficulties in frequent milk discharge due to disease such as teat injury. The period was compared among cows milked twice a day after 150 or 450 mg of CEZ were administered to all quarters (Study 1, 2) and the cows in which milking of front-right quarter was ceased for five days after administration of these infusions to only that quarter (Study 3). In Studies 1 and 2, the median of 17.66 µg/ml and 83.18 µg/ml of CEZ were detected in the samples of first milking after intramammary administration, respectively; however, there was no residual antibiotic by 72 hr in all cows. In Study 3, the median of 1.96 µg/ml of CEZ was detected in the sample after the resumption of milking at 120 hr, and the residual was eliminated by 174 hr. The withdrawal period may be prolonged by the cessation of milking after administration, and the period is the total time from cessation to 72 hr after the resumption of milking.  相似文献   
107.
Point-of-care (POC) devices that veterinary practitioners can use to easily and rapidly measure blood ionized calcium (iCa) levels in cows immediately after withdrawing a blood sample on the dairy farm are needed. Aims of present studies was to compare the commercially available ion-selective electrode handheld iCa meter (bovine blood iCa checker) with the benchtop blood gas analyzer GEM premier 3500 and handheld analyzer i-STAT 1. Sixty-two paired-point whole blood samples were obtained from three cows with hypocalcemia experimentally induced by Na2-EDTA infusion. Whole blood samples were also obtained from the 36 cows kept on a farm in field conditions. The results using the bovine blood iCa checker correlated with those using the GEM premier 3500 and i-STAT 1. Bovine blood iCa checker was “compatible” with the GEM premier 3500 and i-STAT 1 because the frequency of differences between the measurements within ± 20% of the mean were 100% (65/65, >75%) and 90.8% (59/65, >75%), respectively. In the field trial, the blood iCa concentration measured by the bovine blood Ca checker was significantly positively correlated with that measured by the i-STAT 1 portable analyzer. Bovine blood iCa checker was “compatible” with the i-STAT 1 because the frequency of differences between the measurements within ± 20% of the mean was 100% (36/36, >75%). Results from these findings, the bovine blood iCa checker may be applied as a simplified system to measure the iCa concentration in bovine whole blood.  相似文献   
108.
We hypothesized that the serum iron (Fe) concentration in cows with respiratory diseases is a satisfactory substitute for major inflammatory markers such as haptoglobin (HPT) and serum amyloid A (SAA). Twenty Japanese Black cows aged 279.6 ± 120.0 days were enrolled, and divided into respiratory diseases and control groups based on the presence of clinical findings of respiratory diseases. As a result, area under the receiver operating characteristic curves for plasma HPT, SAA and serum Fe concentrations for respiratory disease-associated systemic inflammation were excellent, at 1.00, 0.96 and 0.97, respectively. Therefore we confirmed that the serum Fe concentration is a satisfactory substitute for HPT and SAA in beef cows with respiratory diseases.  相似文献   
109.
ABSTRACT:   Among all of the decapods that have been studied, only one kind of gland, the androgenic gland, has been found attached to the subterminal ejaculatory region of the vas deferens. In the present study of the red swamp crayfish, it was found that two kinds of gland-like tissues were attached to the subterminal ejaculatory region of the vas deferens. One of the tissues, which is referred to as TIB, is located inside the body cavity, whereas the other tissue, which is referred to as TIC, is inside the coxa. The characteristics of TIB resemble those of the androgenic gland of other malacostracans. The TIC cells, however, are smaller and more basophilic due to the small size and high density of their cytoplasm and nuclei. Moreover, black fibers, similar to the nerve fibers of the ganglion, were detected among the TIC cells after Bodian's stain. The conclusion is that TIC may be a newly found male sexual characteristic and further research is needed to confirm its functions.  相似文献   
110.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号