首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   234篇
  免费   5篇
畜牧兽医   239篇
  2017年   1篇
  2015年   4篇
  2014年   9篇
  2013年   4篇
  2012年   6篇
  2011年   5篇
  2010年   7篇
  2009年   7篇
  2008年   5篇
  2007年   1篇
  2005年   6篇
  2004年   2篇
  2003年   4篇
  2002年   6篇
  2001年   6篇
  2000年   4篇
  1999年   3篇
  1998年   16篇
  1997年   18篇
  1996年   16篇
  1995年   7篇
  1994年   13篇
  1993年   19篇
  1992年   40篇
  1991年   20篇
  1990年   7篇
  1989年   1篇
  1985年   1篇
  1983年   1篇
排序方式: 共有239条查询结果,搜索用时 20 毫秒
71.
72.
Objective—To determine and compare the in vitro pullout strength of 5.5-mm cortical versus 6.5-mm cancellous bone screws inserted in the diaphysis and metaphysis of adult equine third metacarpal (MCIII) bones, in threaded 4.5-mm cortical bone screw insertion holes that were then overdrilled with a 4.5-mm drill bit to provide information relevant to the selection of a replacement screw if a 4.5-mm cortical screw is stripped. Study Design—In vitro pullout tests of 5.5-mm cortical and 6.5-mm cancellous screws in equine MCIII bones. Sample Population—Two independent cadaver studies each consisting of 14 adult equine MCIII bones. Methods—Two 4.5-mm cortical screws were placed either in the middiaphysis (study 1) or distal metaphysis (study 2) of MCIII bones. The holes were then overdrilled with a 4.5-mm drill bit and had either a 5.5-mm cortical or a 6.5-mm cancellous screw inserted; screw pullout tests were performed at a rate of 0.04 mm/second until screw or bone failure occurred. Results—In diaphyseal bone, the screws failed in all tests. Tensile breaking strength for 5.5-mm cortical screws (997.5 ± 49.3 kg) and 6.5-mm cancellous screws (931.6 ± 19.5 kg) was not significantly different. In metaphyseal bone, the bone failed in all tests. The holding power for 6.5-mm cancellous screws (39.1 ± 4.9 kg/mm) was significantly greater than 5.5-mm cortical screws (23.5 ± 3.5 kg/mm) in the metaphysis. There was no difference in the tensile breaking strength of screws in the diaphysis between proximal and distal screw holes; however, the holding power was significantly greater in the distal, compared with the proximal, metaphyseal holes. Conclusions—Although tensile breaking strength was not different between 5.5-mm cortical and 6.5-mm cancellous screws in middiaphyseal cortical bone, holding power of 6.5-mm cancellous screws was greater than 5.5-mm cortical screws in metaphyseal bone of adult horses. Clinical Relevance—If a 4.5-mm cortical bone screw strips in MCIII diaphyseal bone of adult horses, either a 5.5-mm cortical or 6.5-mm cancellous screw, however, would have equivalent pullout strengths. A 6.5-mm cancellous screw, however, would provide greater holding power than a 5.5-mm cortical screw in metaphyseal bone.  相似文献   
73.
Objective— To determine whether ischemic postconditioning can attenuate intestinal ischemia–reperfusion (I–R) injury and has a beneficial effect on tissue blood flow during reperfusion. Study Design— In vivo experimental study. Animals— New Zealand White rabbits (n=6). Methods— Rabbits were anesthetized with pentobarbital, to avoid the preconditioning effects of volatile anesthetics, and ventilated with room air. Rectal temperature, hemodynamics, and normocapnia were maintained. After celiotomy, 3 jejunal segments were isolated in each rabbit for the following groups: (1) control, (2) I–R, and (3) I–R with postconditioning. I–R was induced by a 45‐minute occlusion of the segment jejunal artery followed by 2‐hour reperfusion. The postconditioning segment had 4 cycles of 30‐second reperfusion and 30‐second reocclusion during the initial 4 minutes of reperfusion. Stable isotope‐labeled microspheres were used to measure intestinal blood flow at baseline, end occlusion, and end reperfusion. At the end of reperfusion, intestine segments were harvested and the rabbits euthanatized. A semiquantitative histopathologic evaluation (0–5) was conducted by a single, blinded observer. Wet‐to‐dry weight ratios were calculated to assess intestinal edema. Results— There was no significant difference in grade of necrosis, tissue wet‐to‐dry weight ratios, or blood flow at any time point between ischemic and postconditioning groups. Conclusions— Ischemic postconditioning was ineffective in this model of intestinal I–R. Clinical Relevance— Further experimental studies will need to be performed before clinical application of postconditioning for intestinal ischemia.  相似文献   
74.
Transrectal palpation in llamas can result in iatrogenic rectal and colonic injury. The purpose of this report is to define the caudal extent of the peritoneal cavity in llamas and to describe the surgical management of rectal or colonic injuries in four llamas. Measurements were made of six adult llamas during necropsy. The mean distance from the peritoneal reflection to the anus was 3.9 ± 0.1 cm (3.4 - 4.3 cm). Four llamas were examined for rectal or colonic perforations. One laceration was of partial thickness and three lacerations were of full thickness. Two of the defects were repaired by a transanal approach and two by celiotomy to facilitate removal of fecal debris and abdominal lavage. Successful repair of the rectal or colonic tears was achieved in all four llamas. Wound infection and incisional hernia occurred in both llamas that underwent celiotomy. Two llamas died 3 and 18 months later, and two llamas have survived 2 years. Rectal tears in llamas are accompanied by a high risk of peritoneal contamination, and primary closure is recommended. If fecal contamination of the abdomen has occurred, celiotomy is indicated to allow mechanical removal of fecal debris and peritoneal lavage.  相似文献   
75.
The medial collateral ligament of one stifle in 20 adult dogs was excised and replaced with polypropylene mesh or a polyester suture. After 26 weeks, the fibrous tissue-prosthesis composites were evaluated clinically, morphologically, and biomechanically. Clinical lameness was not significantly different after 10 days. The polypropylene mesh reconstructions consistently had more fibrous tissue and greater collagenous ingrowth than the polyester suture reconstructions. There were four complications related to fixation of the polypropylene mesh prosthesis and one to the polyester suture. The polypropylene mesh reconstructions had greater stability and were biomechanically more similar to the natural ligaments than the polyester suture reconstructions. Although the results with polypropylene mesh were favorable, more challenging biomechanical testing and alternative anchoring techniques are required before polypropylene mesh can be recommended as a collateral ligament replacement in dogs.  相似文献   
76.
77.
Two dogs with tumors in the left nasal vestibule were treated by surgical excision of the affected part of the nose. Radiation and chemopotentiation were used in one dog, which remained tumor-free after 12 months. When recovering from anesthesia, the second dog developed respiratory distress associated with upper airway obstruction and failure to mouth breathe. The dog was successfully treated by temporary tracheostomy and remained tumor-free after 3 months. Surgery preserved the function of the right nostril and gave an acceptable cosmetic result in both cases.  相似文献   
78.
Objective — This study evaluates the efficacy of the Palmaz balloon expandable intraluminal stent in the trachea and mainstem bronchi of normal dogs. Study Design — Effects of the stent were evaluated by physical examination, thoracic radiography, respiratory tract fluoroscopy and endoscopy, tracheal diameter measurement, postmortem examination, and airway histomorphometry. Animals or Sample Population — Ten normal beagle dogs. Methods — Stent size was estimated from thoracic radiographs in awake dogs. Group I dogs (n = 4) had two stents placed: one in the thoracic trachea (TT) plus a randomly chosen mainstem bronchus (MB). Group II dogs (n = 3) had stents placed in the MB (one stent), TT (one stent), and mid- or proximal cervical trachea (CT) (one or two stents). Three dogs were used as sham-operated controls (group III). Temperature, pulse, respiration, and cough were measured twice daily. Dogs were evaluated at 21 and 49 to 56 days after stent placement, euthanatized, and tissues were collected for histomorphometric analysis of stent integration and epithelial pathology. Results — Mean tracheal diameters of awake (10.5 ±1.7 mm) and anesthetized dogs before stent implantation (13.9 ± 2.0 mm) were significantly different (P <.01). Complications associated with stent placement included acute pulmonary edema (n = 2), stent migration (n = 7), stent collapse (n = 4 CT, 2 TT, and 1 MB), and positive tracheal culture (n = 10). Group II dogs coughed more at rest, exercise, and with tracheal palpation than dogs in other groups (P <.01). Group I dogs coughed more at rest than group III dogs (P <.01). Stent integration ranged from 0 to 91.3%. Squamous metaplasia and epithelial ulceration associated with stents ranged from 0 to 57.5% and 0 to 32.7%, respectively. Conclusions — Determination of stent size should be based on measurements taken on anesthetized dogs because use of inappropriately sized stents may promote stent migration, squamous metaplasia, and/or ulceration. Epithelialization over stent struts may occur if the stent is closely associated with tracheal epithelium. Clinical Relevance — Palmaz stents do not appear to be appropriate for placement in the CT of dogs; however, with technical modifications, application in the TT and MB may be feasible.  相似文献   
79.
Objective- To assess the clinical results in dogs with acetabular fractures stabilized using a screw-wire-polymethylmethacrylate (SWP) composite fixation.
Study Design- A retrospective study of client-owned dogs with acetabular fractures.
Animals- Fourteen dogs ranging in age from 4 to 95 months (mean, 34 ±25 months; median, 25 months) and body weight from 8 to 39 kg (mean, 25 ±6 kg; median, 27 kg).
Methods- Medical records and radiographs were retrospectively evaluated to determine location of the fracture, presence of preexisting degenerative joint disease, accuracy of fracture reduction and complications associated with surgery. Long-term results were evaluated by subjective assessment of lameness, elicitation of pain and/or crepitus on manipulation of the coxofemoral joint, measurements of pelvic limb circumference, coxofemoral joint goniometric measurements, and radiographic evaluation.
Results- Fracture reduction was considered anatomic in 13 dogs. At the time of the last follow-up evaluation (mean, 347 ±261 days; median, 380 days) 10 dogs were sound on the affected limb, three dogs had a subtle weight-bearing lameness of the affected limb, and the remaining dog had a consistent non-weight-bearing lameness of the affected limb. Mild (n = 10) or moderate (n = 1) degenerative changes of the affected coxofemoral joint attributed to the acetabular fracture and its repair were noted on the follow-up radiographs in 11 dogs. Limb circumference of the affected limb ranged from -8.2% to +10.8% (mean, -0.8 ±4.2%; median, -0.7%) of the contralateral limb.
Conclusions- The SWP composite fixation consistently maintained anatomic reduction, was associated with few complications, and yielded satisfactory clinical results.
Clinical Relevance- The SWP composite fixation technique would seem to be an acceptable means of stabilizing acetabular fractures in dogs.  相似文献   
80.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号