全文获取类型
收费全文 | 138篇 |
免费 | 3篇 |
专业分类
综合类 | 12篇 |
农作物 | 1篇 |
水产渔业 | 2篇 |
畜牧兽医 | 126篇 |
出版年
2019年 | 1篇 |
2017年 | 1篇 |
2016年 | 1篇 |
2015年 | 1篇 |
2014年 | 1篇 |
2013年 | 4篇 |
2011年 | 1篇 |
2010年 | 4篇 |
2009年 | 5篇 |
2008年 | 2篇 |
2006年 | 1篇 |
2004年 | 4篇 |
2003年 | 4篇 |
2002年 | 3篇 |
2001年 | 2篇 |
2000年 | 2篇 |
1999年 | 7篇 |
1998年 | 17篇 |
1997年 | 15篇 |
1996年 | 11篇 |
1995年 | 6篇 |
1994年 | 9篇 |
1993年 | 9篇 |
1992年 | 4篇 |
1991年 | 3篇 |
1990年 | 4篇 |
1989年 | 7篇 |
1988年 | 2篇 |
1987年 | 2篇 |
1986年 | 3篇 |
1983年 | 1篇 |
1981年 | 3篇 |
1970年 | 1篇 |
排序方式: 共有141条查询结果,搜索用时 15 毫秒
91.
KLAUS OTTO DR. MED. VET. CHARLES E. SHORT DVM MS Dipiomate ACVA 《Veterinary surgery : VS》1991,20(5):362-371
Electroencephalographic (EEG) power spectrum analysis was performed in 18 conscious, adult horses for evaluation as control values for EEG data obtained during anesthesia. Computer-processed total amplitudes for the frequency range 0 to 32 Hz were mainly between 400 and 600 microV, with 80% spectral edge frequency between 16.6 and 32.5 Hz. The highest electrical activity was in the delta band (41.3 +/- 4.4% of total amplitude); there was a less pronounced activity in the beta (34.2 +/- 5.2%), theta (13.6 +/- 1.5%), and alpha (10.0 +/- 1.0%) bands. The applicability of EEG power spectrum analysis as a guide to depth of anesthesia was evaluated in four horses by comparing simultaneously recorded EEG data and clinical signs of anesthesia. Global changes in cerebrocortical electrical activity were detected with a single, monopolar (left frontoatlanto-occipital) EEG lead. Increasing depth of halothane anesthesia was accompanied by a pronounced shift in EEG activity from beta to theta and delta frequency bands, a decrease in 80% spectral edge frequency from 21.5 +/- 2.4 Hz to 12.6 +/- 2.2 Hz, a reduction in the beta/delta ratio of fractional amplitudes from 2.37 +/- 0.84 to 0.49 +/- 0.04, and a slight inconsistent increase in total amplitude from 96.1 +/- 37.3 microV to 185.5 +/- 53 microV. These results show that changes in the clinical signs of anesthetic depth in horses can be described numerically by use of EEG power spectrum analysis. 相似文献
92.
Ultrasonic shear wave velocities of MgSiO3 perovskite at 8 GPa and 800 K and lower mantle composition 总被引:1,自引:0,他引:1
YD Sinelnikov G Chen DR Neuville MT Vaughan RC Liebermann 《Science (New York, N.Y.)》1998,281(5377):677-679
Ultrasonic interferometric measurements of the shear elastic properties of MgSiO3 perovskite were conducted on three polycrystalline specimens at conditions up to pressures of 8 gigapascals and temperatures of 800 kelvin. The acoustic measurements produced the pressure (P) and temperature (T) derivatives of the shear modulus (G), namely ( partial differentialG/ partial differentialP)T = 1.8 +/- 0.4 and ( partial differentialG/ partial differentialT)P = -2.9 +/- 0.3 x 10(-2) gigapascals per kelvin. Combining these derivatives with the derivatives that were measured for the bulk modulus and thermal expansion of MgSiO3 perovskite provided data that suggest lower mantle compositions between pyrolite and C1 carbonaceous chondrite and a lower mantle potential temperature of 1500 +/- 200 kelvin. 相似文献
93.
DR Toomey WSD Wilcock SC Solomon WC Hammond JA Orcutt 《Science (New York, N.Y.)》1998,280(5367):1224-1227
Relative travel time delays of teleseismic P and S waves, recorded during the Mantle Electromagnetic and Tomography (MELT) Experiment, have been inverted tomographically for upper-mantle structure beneath the southern East Pacific Rise. A broad zone of low seismic velocities extends beneath the rise to depths of about 200 kilometers and is centered to the west of the spreading center. The magnitudes of the P and S wave anomalies require the presence of retained mantle melt; the melt fraction near the rise exceeds the fraction 300 kilometers off axis by as little as 1%. Seismic anisotropy, induced by mantle flow, is evident in the P wave delays at near-vertical incidence and is consistent with a half-width of mantle upwelling of about 100 km. 相似文献
94.
Musculoskeletal disorders and psychosocial risk factors among veterinarians in Queensland, Australia 总被引:1,自引:1,他引:0
Objective Although musculoskeletal disorders (MSD) represent one of the most important occupational health issues in contemporary society, few studies have specifically investigated this problem among veterinarians.
Design An anonymous questionnaire survey mailed to all veterinarians registered with the Veterinary Surgeons Board of Queensland during 2006.
Results Almost two-thirds of respondents (63%) had experienced MSD of the lower back, 57% had experienced neck-related MSD, 52% had experienced shoulder-related MSD and 34% had experienced MSD of the upper back during the previous 12 months. MSD was statistically correlated with a range of psychosocial factors, including stress associated with career structure, time pressures, client's attitude, lack of recognition by the public, lack of recognition by colleagues, lack of understanding from family or partners and work stress because of insufficient holidays each year.
Conclusion Overall, this study has demonstrated significant correlations between MSD and psychosocial risk factors among a large cohort of veterinarians, apparently for the first time in the published literature. The results also suggest that personal and workplace issues may contribute more to the development of MSD among veterinarians than many of the previously recognised ergonomic risk factors. 相似文献
Design An anonymous questionnaire survey mailed to all veterinarians registered with the Veterinary Surgeons Board of Queensland during 2006.
Results Almost two-thirds of respondents (63%) had experienced MSD of the lower back, 57% had experienced neck-related MSD, 52% had experienced shoulder-related MSD and 34% had experienced MSD of the upper back during the previous 12 months. MSD was statistically correlated with a range of psychosocial factors, including stress associated with career structure, time pressures, client's attitude, lack of recognition by the public, lack of recognition by colleagues, lack of understanding from family or partners and work stress because of insufficient holidays each year.
Conclusion Overall, this study has demonstrated significant correlations between MSD and psychosocial risk factors among a large cohort of veterinarians, apparently for the first time in the published literature. The results also suggest that personal and workplace issues may contribute more to the development of MSD among veterinarians than many of the previously recognised ergonomic risk factors. 相似文献
95.
96.
97.
98.
99.
Some aspects of the epidemiology of equine salmonellosis 总被引:3,自引:0,他引:3
A survey of 2 horse populations was done to detect the number of asymptomatic faecal excretors of Salmonella sp. 1201 faecal samples from 250 horses hospitalised at the University of Sydney were cultured. Three serotypes, S. typhimurium (4 horses), S. anatum (2) and S. tennessee (1) were isolated from 7 horses (2.8%). None was detected in 75 mares similarly examined at a thoroughbred stud farm. In retrospect, S. typhimurium was also the most common (70%) of the 19 serotypes recovered from 171 horses with clinical salmonellosis seen at Camden, 1969 to 1986. Forty cases occurring since 1983 were reviewed in detail; the mortality rate was high (60%) and an increased proportion was due to S. bovis-morbificans. Five horses developed salmonellosis while hospitalised and it was usually impossible to be certain whether these cases developed from the carrier state into overt disease or resulted from infections acquired in hospital. 相似文献
100.
INTRAVASCULAR ULTRASOUND CONTRAST MEDIA 总被引:1,自引:0,他引:1
Val Schmid DR. MED. VET. Johann Lang DR. MED. VET. 《Veterinary radiology & ultrasound》1995,36(4):307-314
Intravascular ultrasound contrast media are substances that increase the echogenicity of blood. Although not yet completely explored, the clinical applications of intravascular ultrasound contrast media are cardiologic, such as for chamber opacification and myocardial perfusion imaging, the assessment of vascular diseases in general and the study of tumor vessels. Gas-filled bubbles are the preferred echo-enhancing contrast media. Research in this field is concentrating on the creation of very small, stable and non-toxic bubbles, capable of surviving pulmonary transit and appear into the left heart and peripheral vessels. Contrast provided by such media is visible on grey-scale images of the heart and also enhances Doppler signals. The potential clinical applications and the problems related to the creation of ultrasound contrast media suitable for clinical use are reviewed and illustrated by examples of contrast injections performed on patients. 相似文献