全文获取类型
收费全文 | 99篇 |
免费 | 1篇 |
专业分类
农学 | 5篇 |
2篇 | |
综合类 | 16篇 |
水产渔业 | 1篇 |
畜牧兽医 | 72篇 |
植物保护 | 4篇 |
出版年
2020年 | 1篇 |
2016年 | 2篇 |
2013年 | 3篇 |
2012年 | 2篇 |
2011年 | 5篇 |
2010年 | 3篇 |
2009年 | 5篇 |
2008年 | 4篇 |
2007年 | 2篇 |
2006年 | 1篇 |
2004年 | 1篇 |
2001年 | 1篇 |
1999年 | 1篇 |
1998年 | 9篇 |
1997年 | 3篇 |
1996年 | 7篇 |
1995年 | 2篇 |
1994年 | 4篇 |
1993年 | 9篇 |
1992年 | 5篇 |
1991年 | 5篇 |
1990年 | 1篇 |
1989年 | 2篇 |
1988年 | 2篇 |
1987年 | 1篇 |
1986年 | 3篇 |
1985年 | 2篇 |
1983年 | 2篇 |
1980年 | 1篇 |
1979年 | 3篇 |
1974年 | 1篇 |
1957年 | 4篇 |
1956年 | 2篇 |
1948年 | 1篇 |
排序方式: 共有100条查询结果,搜索用时 31 毫秒
41.
Subpolar North Atlantic proxy records document millennial-scale climate variations 500,000 to 340,000 years ago. The cycles have an approximately constant pacing that is similar to that documented for the last glacial cycle. These findings suggest that such climate variations are inherent to the late Pleistocene, regardless of glacial state. Sea surface temperature during the warm peak of Marine Isotope Stage 11 (MIS 11) varied by 0.5 degrees to 1 degrees C, less than the 4 degrees to 4.5 degrees C estimated during times of ice growth and the 3 degrees C estimated for glacial maxima. Coherent deep ocean circulation changes were associated with glacial oscillations in sea surface temperature. 相似文献
42.
Near the Mantle Electromagnetic and Tomography (MELT) Experiment, seamounts form and off-axis lava flows occur in a zone that extends farther to the west of the East Pacific Rise than to the east, indicating a broad, asymmetric region of melt production. More seamounts, slower subsidence, and less dense mantle on the western flank suggest transport of hotter mantle toward the axis from the west. Variations in axial ridge shape, axial magma chamber continuity, off-axis volcanism, and apparent mantle density indicate that upwelling is probably faster and more melt is produced beneath 17 degrees15'S than beneath 15 degrees55'S. Recent volcanism occurs above mantle with the lowest seismic velocities. 相似文献
43.
Magnetic Field and Plasma Observations at Mars: Initial Results of the Mars Global Surveyor Mission 总被引:2,自引:0,他引:2
MH Acu?a JEP Connerney P Wasilewski RP Lin KA Anderson CW Carlson J McFadden DW Curtis D Mitchell H Reme C Mazelle JA Sauvaud C d'Uston A Cros JL Medale SJ Bauer P Cloutier M Mayhew D Winterhalter NF Ness 《Science (New York, N.Y.)》1998,279(5357):1676-1680
The magnetometer and electron reflectometer investigation (MAG/ER) on the Mars Global Surveyor spacecraft has obtained magnetic field and plasma observations throughout the near-Mars environment, from beyond the influence of Mars to just above the surface (at an altitude of approximately 100 kilometers). The solar wind interaction with Mars is in many ways similar to that at Venus and at an active comet, that is, primarily an ionospheric-atmospheric interaction. No significant planetary magnetic field of global scale has been detected to date (<2 x 10(21) Gauss-cubic centimeter), but here the discovery of multiple magnetic anomalies of small spatial scale in the crust of Mars is reported. 相似文献
44.
The Effects of Plate Type, Angle of Ilial Osteotomy, and Degree of Axial Rotation on the Structural Anatomy of the Pelvis 总被引:1,自引:0,他引:1
RANDALL A. GRAEHLER dvm JOSEPH P. WEIGEL DVM. Diplomate acvs ANTHONY D. PARDO MS DVM Diplomate ACVS 《Veterinary surgery : VS》1994,23(1):13-20
Unilateral triple pelvic osteotomy was performed with three variations in technique on canine cadaver pelves. The following variables were studied: the angle of the ilial osteotomy (perpendicular to the long axis of the ilium and 10d?, 20d?, and 30d? off perpendicular); the degree of axial rotation (20d?, 30d?, and 45d?); and the type of fixation (canine pelvic osteotomy plate [CPOP] or a 2.7-mm dynamic compression plate [DCP]). Structural changes measured were the pelvic inlet and acetabular area, interischiatic tuberosity distance, and degree of acetabular version. Means and standard error of the means were determined for all pelvic measurements and were analyzed by three-way analysis of variance (P < .05). As the axial rotation increased from 20d? to 45d? an ilial osteotomy angled 10d?, 20d?, or 30d? resulted in a significantly greater decrease in the pelvic inlet area and significantly less deviation of the interischiatic tuberosity distance and degree of acetabular version from normal than an osteotomy directed perpendicular to the long axis of the ilium. Compared with the CPOP, as the axial rotation increased from 20d? to 45d?, the DCP resulted in a significantly greater decrease in the pelvic inlet area, an increase in the interischiatic tuberosity distance and degree of acetabular version, and less of an increase in the acetabular area. The results of this study suggest that to maximize dorsal acetabular coverage, while minimizing disruption of normal pelvic architecture, a CPOP and an ilial osteotomy angled 10d? to 30d? are preferred for all degrees of axial rotation. 相似文献
45.
Sheep were immunised with Corynebacterium pseudotuberculosis toxoid formulated as a monocomponent vaccine with aluminium adjuvant or in combination with 5 clostridial antigens, and also in the combined form with sodium selenate. Immunised and control sheep were experimentally infected 16 days after vaccination and slaughtered and inspected after a further 3 months to determine their resistance to infection. All 3 vaccines afforded an equal and high level of protection; 91% of vaccinated sheep exhibiting no lesions of caseous lymphadenitis compared with 51.5% affected sheep in the control group. Average lesion counts were 1.2 per affected vaccinated sheep and 4.5 per affected control sheep. Antitoxin responses to the clostridial toxoids incorporated in the combined vaccines were not affected by inclusion of the C pseudotuberculosis toxoid or the sodium selenate. 相似文献
46.
Immunisation against ovine caseous lymphadenitis: comparison of Corynebacterium pseudotuberculosis vaccines with and without bacterial cells 总被引:2,自引:0,他引:2
Sheep were immunised with Corynebacterium pseudotuberculosis vaccines prepared from cell-free toxoid or from toxoid with formalin-killed cells of C pseudotuberculosis added. Resistance of sheep to infection was tested 6 months after immunisation by inoculation with caseous lymphadenitis pus. The outcome was assessed 3 months later by slaughter and inspection of the sheep for lesions of caseous lymphadenitis. immunised sheep were adequately protected against infection as shown by a significant reduction in the number of sheep exhibiting lesions compared with control sheep, and by fewer abscesses in affected vaccinated sheep than in affected control sheep. The protective potency of the vaccines was not improved by the inclusion of cells of C pseudotuberculosis. 相似文献
47.
JACQUES DUPUIS DMV MS Diplomate ACVS JOSEPH HARARI MS DVM Diplomate ACVS DONALD M. BLACKKETTER PhD ANTHONY M. GALLINA DVM PhD 《Veterinary surgery : VS》1994,23(6):456-465
Cranial transposition of the fibular head stabilizes the stifle joint by displacing the distal attachment of the lateral collateral ligament (LCL). The forces applied to the LCL after displacement may cause ligamentous elongation. This investigation evaluated the morphological, histological, and biomechanical changes of the LCL after fibular head transposition (FHT) in dogs. Unilateral cranial cruciate ligament (CCL) excision and FHT were performed on 25 dogs. Cross-sectional area, length, histological, and structural properties of the LCL were evaluated 3 weeks, 4 months, and 10 months after surgery. Ligament length means were significantly increased at week 3, month 4, and month 10 compared with intraoperative length means. No significant changes in elongation were observed after week 3. Fibrovascular proliferation within the LCL increased the cross-sectional area and associated structural properties. 相似文献
48.
MICHAEL D. MAJOR DVM MS BARRIE D. GRANT DVM MS Diplomate ACVS KARL K. WHITE DVM Diplomate ACVS MARC H. RATZLAFF DVM PhD ANTHONY M. GALLINA DVM PhD RICHARD M. DONATI MD 《Veterinary surgery : VS》1992,21(2):126-132
The suspensory apparatus of one forelimb was surgically disrupted in six adult horses by transecting the distal sesamoidean ligaments. A double-braided prosthetic ligament made of aramid yarn was installed to support the flexor surface of the metacarpophalangeal joint. The prosthesis was routed through tunnels in the third metacarpal bone and proximal phalanx, and secured to bone with screws. Evaluation by radiography, synovial fluid analysis, cinematography, and dynamography was performed before surgery and at weeks 16 and 30. Supracondylar cortical lysis and periosteal proliferation were observed on postoperative radiographs. Synovitis and fragmentation of the prosthesis were apparent from synovial fluid evaluation. Weight bearing and metacarpophalangeal joint motion were decreased and loading was transferred in part to the opposite forelimb. Clinical lameness improved and weight bearing increased during the second half of the 30-week period. At necropsy, there was abrasion of the prosthesis and the articular surfaces in contact with the prosthesis. Diffuse granulomatous synovitis developed in response to aramid fiber fragments within the synovium. 相似文献
49.
ANTHONY T. BLIKSLAGER dvm LLOYD P. TATE Jr. VMD Dipiomate acvs DANIEL WEINSTOCK DVM PhD Dipiomate ACVS 《Veterinary surgery : VS》1993,22(5):351-356
Effects of neodymium:yttrium aluminum garnet (Nd:YAG) laser irradiation on equine endometrium were evaluated In vitro and in six mares with endometrial cysts. The Nd:YAG laser was applied to six endometrial sites, in each of five uterine specimens, with power densities of 5659 to 33,954 J/cm2 . Depth of tissue ablation was measured and graded on histologic sections of the tissue lesions. Power density had a significant effect on the depth of tissue ablation (p < .001). Grade 3 lesions (full-thickness ablation of the endometrium) were created with energy densities of 16,977 to 33,954 J/cm2 . Six mares had endometrial cysts treated by photoablation. Two of the four mares that were reproductively sound but barren, despite appropriate breeding, produced foals after treatment. One mare remained reproductively unsound after treatment, and another mare that was treated postpartum was bred successfully. 相似文献
50.
Microneurovascular Free Digital Pad Transfer in the Dog 总被引:1,自引:0,他引:1
ANTHONY W. P. BASHER BVetMed MVSc MRCVS DiplomateACVS J. DAVID FOWLER DVM MVSc DiplomateACVS C. VAUGHAN BOWEN MB ChB FRCS EDWARD G. CLARK DVM MVSC DiplomateACVP NANCY L. CROSBY BSC AHT 《Veterinary surgery : VS》1990,19(3):226-231
By cadaver dissections, the fifth digit of the canine hind limb was determined to have a consistent neurovascular anatomy, and therefore be a suitable donor for an axial pattern digital pad flap. The defined digital pad flap was transferred to the region of an excised metacarpal pad by microneurovascular anastomoses in five operations on four dogs. One flap failure was considered to result from failure of the venous anastomosis. In all four successful transfers, cutaneous sensation was reestablished on average in 78 days. There was histologic evidence of nerve regeneration across the anastomosis in one dog at week 24. The transferred pads of three dogs monitored for 15 months underwent hypertrophic changes. There were no complications in two active dogs. In one dog, superficial ulceration of a region of the flap adjacent to the pad required surgical revision. This dog continued to show mild lameness after daily runs of 3 to 4 km. 相似文献