全文获取类型
收费全文 | 125篇 |
免费 | 16篇 |
国内免费 | 1篇 |
专业分类
综合类 | 15篇 |
农作物 | 1篇 |
畜牧兽医 | 122篇 |
植物保护 | 4篇 |
出版年
2023年 | 1篇 |
2020年 | 3篇 |
2019年 | 2篇 |
2018年 | 5篇 |
2017年 | 4篇 |
2016年 | 8篇 |
2015年 | 5篇 |
2014年 | 5篇 |
2013年 | 13篇 |
2012年 | 1篇 |
2011年 | 2篇 |
2010年 | 3篇 |
2009年 | 14篇 |
2008年 | 3篇 |
2007年 | 2篇 |
2006年 | 6篇 |
2005年 | 3篇 |
2004年 | 5篇 |
2003年 | 2篇 |
2002年 | 1篇 |
1999年 | 2篇 |
1998年 | 8篇 |
1997年 | 9篇 |
1996年 | 4篇 |
1995年 | 3篇 |
1994年 | 1篇 |
1993年 | 5篇 |
1992年 | 2篇 |
1991年 | 6篇 |
1990年 | 5篇 |
1989年 | 4篇 |
1988年 | 4篇 |
1971年 | 1篇 |
排序方式: 共有142条查询结果,搜索用时 15 毫秒
121.
122.
A 13-year-old Morgan gelding was examined for right forelimb lameness and tenosynovitis of the right common carpal sheath of the digital flexor tendons. The horse had moderate right forelimb lameness at the trot and marked effusion of the right common carpal sheath of the digital flexor tendons. Ultrasonographic examination revealed a soft tissue mass within the proximal pouch of the affected tendon sheath, located adjacent to the distal physis of the radius. Cytology and culture of the fluid revealed a sterile, eosinophilic tenosynovitis. Tenoscopic exploration confirmed the presence of a capsulated soft tissue mass. Thecotomy was required to fully debride the mass, which histology revealed to be a mast cell tumour. At 22 months postoperatively, the horse developed mild right forelimb lameness and eosinophilic tenosynovitis because of recurrence of the mastocytoma. Mastocytosis is a possible differential diagnosis in any horse exhibiting lameness associated with tenosynovitis. Surgical excision combined with rest and postoperative intrasynovial and systemic corticosteroids may be palliative. 相似文献
123.
DH Hathaway PA Gilman JW Harvey F Hill RF Howard HP Jones JC Kasher JW Leibacher JA Pintar GW Simon 《Science (New York, N.Y.)》1996,272(5266):1306-1309
Doppler velocity observations obtained by the Global Oscillation Network Group (GONG) instruments directly measure the nearly steady flows in the solar photosphere. The sun's differential rotation is accurately determined from single observations. The rotation profile with respect to latitude agrees well with previous measures, but it also shows a slight north-south asymmetry. Rotation profiles averaged over 27-day rotations of the sun reveal the torsional oscillation signal-weak, jetlike features, with amplitudes of 5 meters per second, that are associated with the sunspot latitude activity belts. A meridional circulation with a poleward flow of about 20 meters per second is also evident. Several characteristics of the surface flows suggest the presence of large convection cells. 相似文献
124.
Objective To investigate the practical application and image quality of transcutaneous ultrasonography across the right flank for the diagnosis of mid- to late-gestation in cattle.
Procedure Dairy cows of known pregnancy status were used to establish criteria for the identification of mid- to late-stage pregnancy by transcutaneous ultrasonography. Factors involved in the practical application of transcutaneous ultrasound for routine use in pregnancy diagnosis in dairy cattle were also examined.
Results Transcutaneous ultrasound, using a 3.5-MHz sector transducer applied over the caudodorsal right flank fold, allowed rapid and detailed visualisation of bovine pregnancy (i.e. fetus, fetal fluids, placentomes and/or fetal membranes) and could be used to establish criteria for the diagnosis of pregnancy. The commonly available cattle holding facilities of the herringbone dairy, rotary herringbone dairy, AI race or crush, and walk-through dairy all allow safe access to the right flank of a dairy or beef cow. However, transcutaneous scanning over the right flank is difficult in modern rotary turnstile dairies.
Conclusion A 3.5-MHz sector transducer applied over the caudodorsal right flank fold allows detailed visualisation of the bovine fetus in most types of cattle-holding facilities. Further investigation of the sensitivity and specificity of this technique over the entire gestation period and its possible use in ageing of the bovine fetus is merited. 相似文献
Procedure Dairy cows of known pregnancy status were used to establish criteria for the identification of mid- to late-stage pregnancy by transcutaneous ultrasonography. Factors involved in the practical application of transcutaneous ultrasound for routine use in pregnancy diagnosis in dairy cattle were also examined.
Results Transcutaneous ultrasound, using a 3.5-MHz sector transducer applied over the caudodorsal right flank fold, allowed rapid and detailed visualisation of bovine pregnancy (i.e. fetus, fetal fluids, placentomes and/or fetal membranes) and could be used to establish criteria for the diagnosis of pregnancy. The commonly available cattle holding facilities of the herringbone dairy, rotary herringbone dairy, AI race or crush, and walk-through dairy all allow safe access to the right flank of a dairy or beef cow. However, transcutaneous scanning over the right flank is difficult in modern rotary turnstile dairies.
Conclusion A 3.5-MHz sector transducer applied over the caudodorsal right flank fold allows detailed visualisation of the bovine fetus in most types of cattle-holding facilities. Further investigation of the sensitivity and specificity of this technique over the entire gestation period and its possible use in ageing of the bovine fetus is merited. 相似文献
125.
MA Stornelli JC Reyna MC Stornelli R Nuñez Favre CA Savignone CM Tittarelli RL de la Sota 《Reproduction in domestic animals》2009,44(S2):287-290
The aim of this study was to asses the variation in the morphology of the seminal epithelium in relation to natural photoperiod in male cats. Tom cats (n = 240) were castrated every other week throughout the year. Each testis was fixed in Bouin's solution and cut into sections. The percentage of tubules with round spermatids (RS), elongated spermatids (ES), tailed spermatids (TS), mature spermatids (MS) and the number of Sertoli cells (SC) and Leydig cells (LC) were recorded in each sample. Testicles from males during short days (SHD) had a higher percentage of tubules with RS and ES compared to testicles from males during long days (LHD, 31.3 ± 0.6 vs 2.1 ± 0.6%, p < 0.001; 30.9 ± 0.7 vs 11.0 ± 0.7%, p < 0.001). Conversely, testicles from males during SHD had a lower percentage of tubules with TS and MS compared to testicles from males during LHD (24.5 ± 0.8 vs 29.7 ± 0.8%, p < 0.01; 13.1 ± 1.2 vs 57.0 ± 1.2%, p < 0.01). Furthermore, testicles from males during SHD had a higher number of SC and lower number of LC compared to testicles from males during LHD (11.4 ± 0.1 vs 8.0 ± 0.1%, p < 0.01; 19.2 ± 1.0 vs 38.0 ± 1.0%, p < 0.01). In conclusion, there are seasonal changes in testis cell morphology in the tom which may be related to seasonal sperm production. 相似文献
126.
127.
128.
AbstractAIMS: To assess the effect of two temperatures (ambient temperature and 4°C), three preservation methods (no preservative, yoghurt and potassium sorbate), and two periods of storage (3 and 7 days) on Brix and total bacterial and coliform counts of colostrum collected from New Zealand dairy farms.METHODS: One litre of colostrum destined to be fed to newborn calves was collected from 55 New Zealand dairy farms in the spring of 2015. Six aliquots of 150 mL were obtained from each colostrum sample, with two aliquots left untreated, two treated with potassium sorbate and two with yoghurt, and one of each pair of aliquots stored at ambient temperature and the other at 4°C. All samples were tested for Brix, total bacterial counts and coliform counts before treatment (Day 0), and after 3 and 7 days of storage. The effect of preservation method and storage temperature on the change in Brix, bacterial and coliform counts after 3 or 7 days of storage was analysed using multivariable random effects models.RESULTS: For all outcome variables there was a temperature by preservation interaction. For aliquots preserved with potassium sorbate, changes in Brix and bacterial counts did not differ between aliquots stored at ambient temperature or 4°C, but for aliquots preserved with yoghurt or no preservative the decrease in Brix and increase in bacterial counts was greater for aliquots stored at ambient temperature than 4°C (p<0.001). For aliquots preserved with potassium sorbate, coliform counts decreased at both temperatures, but for aliquots preserved with yoghurt or no preservative coliform counts increased for aliquots stored at 4°C, but generally decreased at ambient temperatures (p<0.001). There was also an interaction between duration of storage and temperature for bacterial counts (p<0.001). The difference in the increase in bacterial counts between aliquots stored at 4°C and ambient temperature after 3 days was greater than between aliquots stored at 4°C and ambient temperature after 7 days.CONCLUSIONS AND CLINICAL RELEVANCE: Use of potassium sorbate to preserve colostrum for 3 or 7 days resulted in little or no reduction in Brix and a lower increase in total bacterial counts than colostrum stored without preservative or with yoghurt added. Colostrum quality was not affected by storage temperature for samples preserved with potassium sorbate, but storage at 4°C resulted in better quality colostrum than storage at ambient temperatures for colostrum with no preservative or yoghurt added. 相似文献
129.
DM Hassler IE Dammasch P Lemaire P Brekke W Curdt HE Mason JC Vial K Wilhelm 《Science (New York, N.Y.)》1999,283(5403):810-813
Observations of outflow velocities in coronal holes (regions of open coronal magnetic field) have recently been obtained with the Solar and Heliospheric Observatory (SOHO) spacecraft. Velocity maps of Ne7+ from its bright resonance line at 770 angstroms, formed at the base of the corona, show a relationship between outflow velocity and chromospheric magnetic network structure, suggesting that the solar wind is rooted at its base to this structure, emanating from localized regions along boundaries and boundary intersections of magnetic network cells. This apparent relation to the chromospheric magnetic network and the relatively large outflow velocity signatures will improve understanding of the complex structure and dynamics at the base of the corona and the source region of the solar wind. 相似文献
130.
EM Crane JC Munro SL Bourgon M Diel de Amorim R Ventura AH Fredeen YR Montanholi 《Reproduction in domestic animals》2016,51(5):819-826
Haematological metabolic profiles in heifers could contribute to the development of proxies for oestrous detection and provide clues to further characterize biological changes during oestrus. One hundred and seven beef heifers were observed for oestrous behaviour twice daily for 124 days. Feed intake and productive performance (body weight and composition) traits were measured, and feed efficiency was determined using residual feed intake (kg DM/day). Blood plasma samples were collected when signs of oestrus were observed and every 30 ± 2 days. Heifers were considered in oestrus (n = 71) when plasma progesterone concentrations were <0.6 ng/ml. Least square means of blood metabolic parameters were compared between oestrous and non‐oestrous states and within oestrous groups according to performance traits and age. Heifers in oestrus exhibited higher concentrations of alkaline phosphatase, aspartate aminotransferase (AST), beta‐hydroxybutyric acid, creatine kinase (CK) and triiodothyronine (T3) than heifers in non‐oestrus. Heifers in oestrus revealed lower osmolality and concentrations of calcium, sodium and total protein than during non‐oestrus. Younger (and smaller) heifers had greater concentrations of CK, gamma‐glutamyl transferase (GGT), glucose and sodium than the older heifers. Heifers with lower fatness had increased osmolality and concentrations of cholesterol, CK, phosphorus, sodium and reduced T3 levels. Feed efficient heifers had greater levels of AST, cholesterol and GGT than inefficient heifers. Blood plasma parameters may be complementary to oestrous detection upon further validation; effects of age, feed efficiency, body size and body composition should be considered to optimize this haematological assessment. 相似文献