首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   62篇
  免费   0篇
林业   2篇
农学   5篇
综合类   2篇
水产渔业   5篇
畜牧兽医   43篇
植物保护   5篇
  2012年   1篇
  2010年   4篇
  2009年   5篇
  2008年   3篇
  2007年   1篇
  2006年   2篇
  2000年   1篇
  1998年   6篇
  1997年   3篇
  1996年   1篇
  1995年   4篇
  1994年   1篇
  1993年   4篇
  1992年   8篇
  1989年   2篇
  1987年   1篇
  1986年   2篇
  1984年   1篇
  1982年   2篇
  1981年   2篇
  1979年   2篇
  1978年   2篇
  1977年   1篇
  1975年   1篇
  1965年   1篇
  1961年   1篇
排序方式: 共有62条查询结果,搜索用时 78 毫秒
31.
Effects of desmopressin acetate (1-desamino-8-D-arginine vasopressin [DDAVP]) on plasma von Willebrand factor (vWf) were studied in 12 purebred Doberman pinschers confirmed to have von Willebrand's disease (vWd) (plasma vWf antigen [vWf:Ag] concentrations, less than 30 U/dl). Twelve dogs had subnormal plasma botrocetin cofactor (BCf) activity and 11 dogs had prolonged buccal mucosa bleeding times. Tranquilization of three dogs with lenperone and three dogs with xylazine did not induce significant changes in mean plasma vWf:Ag concentrations or mean BCf activities. Thirty and 120 minutes after administration of DDAVP (1 micrograms/kg subcutaneously), there was significant shortening of the mean buccal mucosa bleeding time. Ten dogs responded to DDAVP with increases in BCf activity which exceeded 10 U/dl at 30 or 120 minutes, or both, after the drug was administered. At the same time, increases in plasma vWf:Ag concentrations were smaller than the increases in BCf activity. It was shown by multimeric analysis that primarily the higher molecular weight forms of vWf increased in plasma in response to DDAVP.  相似文献   
32.
Objectives— To compare in vitro monotonic biomechanical properties of an axial 3‐hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion (DCP‐TLS) with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion (3‐TLS) for the equine proximal interphalangeal (PIP) joint arthrodesis. Study Design— Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. Sample Population— Cadaveric adult equine forelimbs (n=15 pairs). Methods— For each forelimb pair, 1 PIP joint was stabilized with an axial 3‐hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion and 1 with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion. Five matching pairs of constructs were tested in single cycle to failure under axial compression, 5 construct pairs were tested for cyclic fatigue under axial compression, and 5 construct pairs were tested in single cycle to failure under torsional loading. Mean values for each fixation method were compared using a paired t‐test within each group with statistical significance set at P<.05. Results— Mean yield load, yield stiffness, and failure load under axial compression and torsion, single cycle to failure, of the DCP‐TLS fixation were significantly greater than those of the 3‐TLS fixation. Mean cycles to failure in axial compression of the DCP‐TLS fixation was significantly greater than that of the 3‐TLS fixation. Conclusion— The DCP‐TLS was superior to the 3‐TLS in resisting the static overload forces and in resisting cyclic fatigue. Clinical Relevance— The results of this in vitro study may provide information to aid in the selection of a treatment modality for arthrodesis of the equine PIP joint.  相似文献   
33.
Abstract— A review is presented of the methods, procedure and value of the use of tonometry in the dog and cat.
Résumé— L'auteur passe en revue les méthodes, les techniques et la valeur de l'emploi de la tonométric chez le chien et le chat.
Zusammenfassung— Es wird eine Übersicht über die Methoden, das Verfahren und die Bedeutung der Tonometrie bie Hund und Katze gegeben.  相似文献   
34.
Disease seventy and crop yield were compared in monocultures and mixtures of two wheat cultivars. one susceptible and one resistant to Puccinia graminis f. sp. tritici. Part of each plot was inoculated and part treated with fungicide. Rust seventy was inversely related to the proportion of resistant plants present. Weight of grain in 100 heads of the susceptible cultivar increased as the amount of rust decreased. The susceptible cultivar yielded less than the resistant cultivar in monoculture, but was a stronger competitor in mixtures. Competitive abilities of the cultivars were independent of severity of rust in the mixtures studied.  相似文献   
35.
36.
The effects of surgical and nonsurgical therapy on the development of osteoarthritis were compared in 12 dogs with bilateral medial patellar luxation and unilateral surgical repair. Evaluations included severity of lameness and patellar luxation, ligamentous stability, range of motion, and radiographic evidence of osteoarthritis before surgery and at a mean of 33 months after surgery. Stifles without surgical treatment served as controls for the contralateral stifles with surgery. All stifles treated surgically had reduced patellofemoral joints, normal range of motion, and improved limb use. Osteoarthritis progressed significantly and comparably in both groups of stifles. Progression of osteoarthritis was not correlated with luxation grade, body weight, or interval from surgery to follow-up. Age at surgery was correlated positively with severity of osteoarthritis in the stifles treated surgically.  相似文献   
37.
The biomechanical characteristics of a 4-ring circular multiplanar fixator applied to equine third metacarpal bones with a 5 mm mid-diaphyseal osteotomy gap were studied. Smooth Steinmann pins, either 1/8 inch, 3/16 inch, or 1/4 inch, were driven through pilot holes in the bone in a crossed configuration and full pin fashion and fastened to the fixator rings using cannulated fixation bolts. The third metacarpal bone fixator constructs were tested in three different modes (cranial-caudal four-point bending, axial compression, and torsion). Loads of 2,000 N were applied in bending and axial compression tests and a load of 50 N ± m was applied during testing in torsion. Fixator stiffness was determined by the slope of the load displacement curves. Three constructs for each pin size were tested in each mode. Comparisons between axial stiffness, bending stiffness, and torsional stiffness for each of the three different pin sizes were made using one-way analysis of variance. There was no visually apparent deformation or permanent damage to the fixator frame, and no third metacarpal bone failure in any of the tests. Plastic deformation occurred in the 1/8 inch pins during bending, compression, and torsion testing. The 3/16 inch and 1/4 inch pins elastically deformed in all testing modes. Mean (±SE) axial compressive stiffness for the 1/8 inch, 3/16 inch, and 1/4 inch pin fixator constructs was: 182 ± 16 N/mm, 397 ± 21 N/mm, and 566 ± 8.7 N/mm; bending stiffness was 106 ± 3.3 N/mm, 410 ± 21 N/mm, and 548 ± 12 N/mm; and torsional stiffness was 6.15 ± 0.82 N.m/degree, 7.14 ± 0.0 N±m/degree, and 11.9 ± 1.0 N.m/degree respectively. For statically applied loads our results would indicate that a 4-ring fixator using two 1/4 inch pins per ring may not be stiff enough for repair of an unstable third metacarpal bone fracture in a 450 kg horse.  相似文献   
38.
Gastric dilatation-volvulus (GDV) was created experimentally and maintained for 90 minutes in 16 anesthetized, mixed-breed dogs. After the GDV was corrected, normal saline solution (0.044 mL/kg intravenously [IV]) was administered to eight dogs (controls), and flunixin meglumine (2.2 mg/kg IV) was administered to eight dogs. Microspheres labeled with radioactive cobalt, scandium, tin, or niobium were injected intravenously at baseline (before GDV) and minutes 90, 100, and 270, respectively, to determine tissue blood flows. Plasma endotoxin and prostacyclin were measured at the same intervals. Electrocardiogram, mean arterial pressure, portal pressure, and cardiac output were recorded continuously. Dogs were euthanatized at minute 270 and necropsied. There was no significant difference between treatment groups for any measured variable at any time. Endotoxin levels increased significantly during GDV. Prostacyclin levels were lower in dogs treated with flunixin meglumine than in controls at minutes 210 and 270. Histopathologic findings were similar for all dogs and consistent with those associated with endotoxemia. Flunixin meglumine treatment did not alter cardiac indices or tissue blood flows significantly. However, elevation of prostacyclin was inhibited by flunixin meglumine, which suggested that continued effects of endotoxic damage might be attenuated or inhibited.  相似文献   
39.
When cerclage wiring is used in skeletally immature dogs, the wires become imbedded in the cortical bone due to radial appositional bone growth.
Six groups of five dogs each received one or two extraperiosteal cerclage wires at the mid-diaphysis of the left femur at the age of five months. Ten dogs were killed immediately, ten dogs were killed at eight weeks postoperatively, and ten at twelve weeks. Both femora from each animal were collected and subjected to torsional loading to failure within.5 seconds. The maximum torque, shear stress, energy absorption, angular deformation, and torsional stiffness were determined and subjected to í test analysis.
Application of the wires predictably caused an increase in weight and cortical bone thickening at the implant site, which was primarily due to endosteal bone deposition in the 8-and 12-week groups. The 8-and 12-week wired bones were stiffer and failed at a lower angular deformation than did their corresponding control femurs, but the zero-time bones did not show this tendency. Significantly less shear stress accumulation and energy absorption at failure were present In the 8-and 12-week implants, but no difference was seen in the zero-time femora. The 8-week groups showed a greater difference between the wired and control femurs than did the 12-week groups. No significant difference was found between one-and two-wire implants in the study.
The results indicate that confinement of dogs with clinically wired fractures of immature canine femurs should extend past eight weeks.  相似文献   
40.
External immobilization and traditional pinning techniques for radius and ulna fractures in immature animals are associated with complications. Prolonged splinting and casting risks postural hyperextension. Pinning techniques may injure growing bones and joints. Eight cases are presented in which fractures of the radius and ulna in immature animals were treated with plates and without external splints. Ail fractures healed without iatrogenic injury to the growing bones and joints and without hyperextension problems of fracture disease. Plating proved a highly effective method of treatment for these fractures in growing animals, avoiding complications and the problems associated with external splinting and traditional pinning techniques.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号