Objective— To describe outcome after an alternative unilateral approach to the thoracolumbar spine for dorsal laminectomy.
Study Design— Retrospective clinical study.
Animals— Dogs (n=14) with thoracolumbar spinal cord compression.
Methods— Thoracolumbar spinal cord compression was lateral (6 dogs), dorsal (4), and dorsolateral (4) caused by subarachnoid (7) and synovial cysts (2) and intradural-extramedullary neoplasia (5). All dogs were treated by dorsal laminectomy with osteotomy of the spinous process using a unilateral paramedian approach. The contralateral paraspinal muscles were not stripped from the spinous process and the osteoligamentous complexes were preserved. Retraction of the spinous process and muscles to the contralateral side resulted in complete visualization of the dorsal vertebral arch thereby allowing dorsal laminectomy to be performed.
Results— No technique complications occurred. Approximately 75% exposure of the spinal cord (dorsal and lateral compartments) was achieved providing adequate visualization and treatment of the lesions. Transient deterioration of neurologic state occurred in 5 dogs because of extensive spinal cord manipulation. At long-term follow-up, 6 dogs were normal, 6 had clinical improvement, and 2 were unchanged.
Conclusion— Dorsal laminectomy after osteotomy and retraction of the spinous process may be considered in canine patients with dorsal, dorsolateral, or lateral compression to facilitate adequate decompression of the spinal cord.
Clinical Significance— This surgical technique offers an alternative approach to the thoracolumbar spine and spinal cord by a modified dorsal laminectomy that preserves the paraspinal muscle integrity on the contralateral side.  相似文献   

3.
Objective— To evaluate outcome after closed fluoroscopic-assisted application of spinal arch external skeletal fixators in dogs with vertebral column injuries.
Study Design— Retrospective case series.
Animals— Dogs with traumatic vertebral column injuries (n=5).
Methods— Medical records of dogs with vertebral column fractures and/or luxations stabilized with spinal arch external skeletal fixator frames applied using a closed fluoroscopic-assisted technique were reviewed. Owners were contacted to obtain long-term clinical outcomes.
Results— Five dogs (age range, 6–72 months; weight, 10–54 kg) had traumatic vertebral column injuries stabilized with spinal arch external skeletal fixators applied in closed fashion. Injuries involved vertebral segments of the thoracolumbar junction, lumbar spine, and lumbosacral junction. Immediately postoperatively, 4 dogs had anatomic alignment of their vertebral fracture/luxation; 1 dog had 1 mm of vertebral canal height compromise. Time to fixator removal ranged from 65 to 282 days (141±87 days). All dogs had regained satisfactory neurologic function by 3 months. At long-term follow-up (range, 282–780 days; mean 445±190 days) all dogs were judged to have good to excellent return of function by their owners.
Conclusion— Successful closed fluoroscopic-assisted application of external skeletal fixators using spinal arches provided satisfactory reduction with few complications in 5 dogs. Return to function was judged to be good to excellent in all dogs at long-term evaluation.
Clinical Relevance— Closed fluoroscopic-assisted application of ESF using spinal arches provided satisfactory reduction and effective stabilization of spinal fractures with few complications and should be considered as a treatment approach.  相似文献   

4.
Three dogs were presented for investigation of spinal disease and were diagnosed with extradural spinal juxtafacet cysts of synovial origin. Two dogs that were presented with clinical signs consistent with pain in the lumbosacral region associated with bilateral hindlimb paresis were diagnosed using magnetic resonance imaging. Both cysts were solitary and associated with the L6-7 dorsal articulations; both the dogs had a transitional vertebra in the lumbosacral region. A third dog that was presented with progressive paraparesis localised to T3-L3 spinal cord segments and compression of the spinal cord at T13-L1 was diagnosed using myelography. A solitary multiloculated cyst was found at surgery. Decompressive surgery resulted in resolution of the clinical signs in all three dogs. Immunohistological findings indicated that one to two layers of vimentin-positive cells consistent with synovial origin lined the cysts.  相似文献   

5.
The effect of implantation of polyvinilidine spinal plates was studied when placed on spinous processes of 11 mixed breed dogs and when placed within the thoracolumbar musculature of 12 male white rats. Specimens were also obtained from soft tissues adjacent to polyvinilidine plates 2 to 3 months after clinical surgery to repair spinal subluxations in three dogs. A similar pattern of dense, organized fibrous tissue interspersed with focal congregations of lymphocytes, plasma cells, and multinucleated giant cells was observed in the dog experiment, rat experiment, and in all clinical cases. Birefringent debris with polarization patterns identical to small slivers of polyvinilidine was associated with the observed reactions. It would appear that either a chemical or physical characteristic of the plates elicited this foreign body reaction. Grooving the inner surface of the plates, which is performed to increase the friction grip when applied to spinous processes, may make the surface texture of the plate more reactive or it may predispose the surface of the plate to minute fragmentation ("wear products").  相似文献   

6.
A new surgical technique was developed for the fixation of caudal lumbar vertebral fractures in dogs. The technique provides optimal stabilization, can be used in combination with dorsal decompression, and does not require an intact spinous process on the fractured vertebra or attachment of the fixation devices to the fractured vertebra. The fixation consists of a Kirschner-Ehmer device and dorsal spinal plates. After fracture healing, only mild sedation of the dog is needed to allow removal of the external hardware used in the fixation. The technique, its indications, and its use in 5 cases are described.  相似文献   

7.
Highly comminuted supracondylar humeral fractures were stabilised in six large-breed dogs with a modified type I external fixator using a craniomedial acrylic connecting column and an Intramedullary pin which was incorporated into the connecting frame. This construct provided sufficient stability to allow satisfactory bone healing in five of the six dogs, while premature removal of the intramedullary pin and external fixator resulted in subsequent refracture of the humerus in the remaining dog. Limb function at the time of final assessment was considered excellent in two dogs, good in three dogs and poor in one dog. The craniomedial acrylic connecting column simplified application of this modified type 1(a) configuration to the humerus by reducing the number of clamps required; the acrylic column also facilitated contouring of the cranlomedial connecting column to the brachium and was readily extended proxlmally to engage the intramedullary pin. In addition, the acrylic connecting column allowed placement of intramedullary pins of varying diameter.  相似文献   

8.
CASE DESCRIPTION: 3 immature screw-tailed dogs were evaluated because of progressive pelvic limb paraparesis. CLINICAL FINDINGS: Each dog had marked ataxia and paresis of the pelvic limbs and a palpable deformity of the midthoracic portion of the vertebral column. Pain perception in the pelvic limbs was considered normal, and there was no evidence of fecal or urinary incontinence in any of the 3 dogs. Radiography and magnetic resonance imaging revealed hemivertebrae with severe dorsoventral stenosis of the vertebral canal resulting in spinal cord compression in 2 dogs and lateral compression in the other. TREATMENT AND OUTCOME: Each dog underwent decompressive surgery consisting of dorsal laminectomy or hemilaminectomy and vertebral stabilization by use of combinations of Kirschner wires or threaded external fixator pins plus polymethylmethacrylate bone cement. All dogs regained strong locomotor function with minimal residual pelvic limb ataxia. CLINICAL RELEVANCE: Little detailed information regarding surgical treatment of hemivertebrae in dogs is available; results of treatment in these 3 dogs suggest that spinal cord decompression and stabilization of the vertebral column can achieve a satisfactory, functional outcome.  相似文献   

9.
Objectives— To describe the clinical outcome of a 4 pin lumbosacral fixation technique for lumbosacral fracture–luxations, and to refine placement technique for iliac pins based on canine cadaver studies.
Study Design— Retrospective and anatomic study.
Sample Population— Dogs (n=5) with lumbosacral fracture-luxations and 8 cadaveric canine pelvi.
Methods— Lumbosacral fracture–luxations were stabilized with a 4 pin (positive-profile threaded) and bone cement fixation. Caudal pins were inserted in the iliac body and cranial pins were inserted into the L7 or L6 pedicle and body. Follow-up examinations and radiographs were performed to assess patient outcome. Intramedullary pins were inserted into the iliac bodies of 8 cadaver pelvi. Radiographs were taken to measure pin insertion angles and define ideal insertion angles that would maximize pin purchase in the ilium.
Results— Follow-up neurologic examination was normal in 4 dogs. Radiographic healing of the fracture was evident in 5 dogs. One implant failure occurred but did not require re-operation. For cadaver iliac pins, mean craniocaudal insertion angle was 29° and mean lateromedial insertion angle was 20°.
Conclusions— Four pin and bone cement fixation effectively stabilizes lumbosacral fracture luxations. The iliac body provides ample bone stock, which can be maximized using an average craniocaudal pin trajectory of 29° and an average lateromedial pin trajectory of 20°.
Clinical Relevance— Lumbosacral fracture–luxations can be stabilized with 4 pin and bone cement fixation in the lumbar vertebrae and iliac body, using 29 and 20° as guidelines for the craniocaudal and lateromedial pin insertion angles in the ilium.  相似文献   

10.
OBJECTIVE: To measure passive spinal movements induced during dorsoventral mobilization and evaluate effects of induced pain and spinal manipulative therapy (SMT) on passive vertebral mobility in standing horses. ANIMALS: 10 healthy adult horses. PROCEDURES: Baseline vertical displacements, applied force, stiffness, and frequency of the oscillations were measured during dorsoventral spinal mobilization at 5 thoracolumbar intervertebral sites. As a model for back pain, fixation pins were temporarily implanted into the dorsal spinous processes of adjacent vertebrae at 2 of the intervertebral sites. Vertebral variables were recorded again after pin placement and treadmill locomotion. In a randomized crossover study, horses were allocated to control and treatment interventions, separated by a 7-day washout period.The SMT consisted of high-velocity, low-amplitude thrusts applied to the 3 non-pin-placement sites. Control horses received no treatment. RESULTS: The amplitudes of vertical displacement increased from cranial to caudal in the thoracolumbar portion of the vertebral column. Pin implantation caused no immediate changes at adjacent intervertebral sites, but treadmill exercise caused reductions in most variables. The SMT induced a 15% increase in displacement and a 20% increase in applied force, compared with control measurements. CONCLUSIONS AND CLINICAL RELEVANCE: The passive vertical mobility of the trunk varied from cranial to caudal. At most sites, SMT increased the amplitudes of dorsoventral displacement and applied force, indicative of increased vertebral flexibility and increased tolerance to pressure in the thoracolumbar portion of the vertebral column.  相似文献   

11.
Steinmann pins and methylmethacrylate were used to stabilize 17 vertebral fractures or luxations and one unstable congenital spinal deformity in 18 dogs of a wide range of ages and body weights. Of 12 dogs available for follow-up examination (4–43 months), 10 were normal or only mildly ataxic, and two were ambulatory but severely ataxic. Five dogs died or were euthanized in the early postoperative period, but none of the deaths could be attributed to the technique. Uncommon complications associated with this fixation technique were pin migration and wound infection.  相似文献   

12.
Objectives— To describe clinical signs, magnetic resonance imaging (MRI) and surgical findings using a lateral approach to the lumbosacral intervertebral foramen and to evaluate clinical outcomes in dogs with or without concurrent dorsal decompression and annulectomy.
Study Design— Retrospective study.
Animals— Dogs (n=20) with degenerative lumbosacral stenosis (DLSS).
Methods— Medical records (2002–2006) of dogs that had lumbosacral lateral foraminotomy alone or in combination with dorsal decompression were reviewed. Degree of dysfunction was assessed separately for each pelvic limb; dogs with unilateral signs were included in group A, those with bilateral signs in group B. Retrieved data were: signalment, history, neurologic status on admission, 3 days, 6 weeks, and 6 months postoperatively, duration of clinical signs, results of MRI, surgical site(s), intraoperative findings, and outcome.
Results— Based on the clinical and MRI findings unilateral foraminotomy was performed in 8 dogs, bilateral foraminotomy in 1 dog, unilateral foraminotomy with concurrent dorsal decompression in 7 dogs, and bilateral foraminotomy with concomitant dorsal decompression in 4 dogs. Surgery confirmed the presence of foraminal stenosis in all dogs, with osteophyte formation and soft tissue proliferations being the most common lesions. Outcome was good to excellent in 19 dogs and poor in 1 dog. Mean follow-up was 15.2 months (range, 6–42 months).
Conclusion— Lateral foraminotomy addresses compressive lesions within exit and middle zones of the lumbosacral foramen.
Clinical Relevance— Successful surgical management of DLSS is dependent on recognition and correction of each of the compressive lesions within the lumbosacral junction.  相似文献   

13.
The purpose of this retrospective study was to review the clinical use along with the short- and long-term outcome in patients treated with Lubra plates to stabilize spinal fracture and dislocations that were considered unstable at time of surgery according to the 'three compartment theory'. The data that were collected included breed, age, gender, body weight of the patients, cause of injury, neurological grade (pre- and postoperative), radiographic findings, surgical treatment, and clinical and radiological outcome. Thirteen dogs and two cats were included with thoracic (1 case), thoracolumbar (3 cases), midlumbar (5 cases) and caudal lumbar (6 cases) vertebral fractures. For stabilization, the small-sized (3 cases), medium-sized (6 cases), and large-sized (6 cases) Lubra plates were used. The clinical outcome was excellent in 10/15 patients, functional in 2/15 and poor in 3/15 with a median follow-up period of nine years (range 2 months to 12 years). The fractures eventually stabilized by ventral spondylosis. No implant failure was seen, however demineralization of the spinous processes necessitated implant removal in one case. Our results suggest that Lubra plating is an appropriate technique for thoracolumbar and lumbar vertebral fractures as well as luxations in dogs and cats. The prognosis for neurological recovery was excellent when the animal had a neurological grade of 3 and was not paralyzed.  相似文献   

14.
Complications developed with the clinical use of Ellis pins in external skeletal fixation in seven dogs weighing 11 to 24 kg. Pins broke at the threaded-nonthreaded shaft junction in six dogs, and there was radiographic evidence of pin loosening six dogs. One pin pulled out causing loss of fixation in one dog. These complications with the recently introduced Ellis pin emphasize a need for further evaluation of its proper use.  相似文献   

15.
Spinal arachnoid pseudocysts in 10 rottweilers   总被引:1,自引:0,他引:1  
Ten rottweilers presenting with spinal arachnoid pseudocysts were investigated. In six dogs, the lesions were localised dorsally at C2-C3; in three dogs, dorsally and ventrally at C5-C6; and, in one dog, dorsally and ventrally at C6-C7. Clinical signs were consistent with focal compression of the affected spinal cord segments. The animals showed ataxia of all four limbs, with truncal ataxia and marked hypermetria in cases of C2-C3 involvement, or ambulatory tetraparesis in cases of C5-C6 or C6-C7 involvement. Other than signs indicative of spina bifida in one dog, no abnormalities could detected on plain radiographs. Myelography was used to define the localisation and extent of the pseudocysts. Additional information was obtained using magnetic resonance imaging in five dogs. Five dogs underwent a dorsal laminectomy; in three cases, the pseudocyst was treated by marsupialisation and, in two, by durectomy.  相似文献   

16.
An external fixator consisting of two Ellis pins connected by a flexible band was developed and evaluated as a treatment for craniodorsal coxofemoral luxations in dogs. The technique for closed application of the fixator without injury to the coxofemoral joint or sciatic nerve was developed in six dog cadavers. The coxofemoral joints were then surgically destabilized and the limbs were manipulated through a full range of motion to assess the efficacy of the fixator in maintaining joint reduction. The fixator maintained joint reduction and stability after a surgically created craniodorsal luxation except when the femur was externally rotated 90d?. A flexible external fixator was then applied unilaterally in four healthy dogs. The dogs tolerated the fixator well and were bearing weight on the limb within 2 days after surgery; the range of motion was not limited by the fixator. The efficacy of a flexible external fixator in maintaining joint reduction after craniodorsal coxofemoral luxation was then evaluated in eight large dogs. The right coxofemoral joint in each dog was luxated surgically by removal of the dorsal joint capsule and transection of the ligament of the head of the femur and deep gluteal muscle. The joint was reduced and the fixator pins were applied in a closed fashion. In four dogs, a flexible external band was applied to the pins. Luxation did not reccur in these four dogs. The bands were not applied initially in four control dogs. Luxation occurred in three of the four control dogs within 24 hours of surgery. The joints that luxated were reduced and the flexible bands applied. Luxation did not recur after the bands were in place. The dogs tolerated the external fixators well, were bearing weight within 2 days of surgery, and walking with only minimal lameness 5 days after surgery. Luxation of the coxofemoral joints did not occur during the 2-week period in which the fixators were in place. The joints remained stable 1 week after removal of the fixators, at which time the dogs were euthanatized. Necropsy evaluation identified inflammation surrounding the pins and fibrous thickening of the dorsal joint capsule. The flexible external fixators were applied closed, maintained reduction of the coxofemoral joint after replacement of a craniodorsal luxation, and allowed weight bearing and limb usage soon after surgery. The flexible external fixator has several advantages over other methods of treating craniodorsal coxofemoral luxations. Complications noted in this study included pin tract drainage, pin loosening, and disruption of the flexible bands.  相似文献   

17.
Atlantoaxial stability was evaluated in 12 surgically stabilized dogs and 6 control dogs after odontoidectomy and dorsal atlantoaxial ligament separation. The atlantoaxial instabilities were stabilized with transarticular pins from a ventral approach. Cancellous bone grafts harvested from the proximal humerus were used to promote joint fusion. Good joint stability, alignment, and early fusion were documented clinically, radiographically, and histopathologically in stabilized dogs. Because of our consistent results despite variable pin angles, we recommend this technique for use in dogs with atlantoaxial instability requiring surgical stabilization.  相似文献   

18.
A technique using a modification of the transilial pin technique for stabilization of fracture/ luxations of the lumbosacral joint was performed in six dogs. This technique used an internal skeletal fixator composed of two transilial pins secured with two double fixator clamps. Collapse (shortening) of the seventh lumbar vertebra (L7) was observed in five dogs without compromise of the vertebral canal. Kirschner wires placed across the articular facets as supplemental fixation devices migrated to the subcutaneous tissues in two dogs and were easily removed. Migration of the internal fixators was not observed during healing; vertebral canal dimensions were maintained in all cases, and the internal fixators were not removed after resolution of fracture healing. All fractures were healed within 6 to 12 weeks of surgery without evidence of pain, neurologic impairment, or long-term complications.  相似文献   

19.
Volumes used in lumbosacral epidural injections for anesthesia have remained unchanged since the 1960s. The goals of this cross‐sectional observational study were to characterize the three‐dimensional spread of a lumbosacral epidural injection, as well as confirm that the commonly used volume of 0.2 ml/kg injected into the lumbosacral epidural space reaches the thoracolumbar (TL) junction in the majority (≥80%) of dogs. Ten clinically normal, adult, nonpregnant, mixed‐breed dogs were obtained within five minutes of euthanasia and 0.2 ml/kg of radiopaque contrast medium was injected into the lumbosacral epidural space. A computed tomography scan of the TL spine was performed immediately following the injection. Migration of contrast reached the TL junction in 8 of 10 (80%) dogs. Contrast was well visualized in all epidural planes with contrast travelling predominantly in the dorsal epidural space in 7 of 10 (70%) dogs. There was no significant difference in the weight of dogs where the epidural injectate reached the TL junction and those where it did not (P = 0.16), or in the weight of dogs where the cranial‐most point of the contrast column was in the dorsal versus the ventral epidural space (P = 0.32). This preliminary study supports the use of computed tomography to characterize injectate distribution in the canine thoracolumbar epidural space and provides evidence that a 0.2‐ml/kg volume is likely to reache the TL junction in most dogs. Further studies are needed in live dogs to determine if variables affecting human epidural injectate doses have similar effects in the dog.  相似文献   

20.
The spinal nerve root origins of the cutaneous nerves innervating the canine pelvic limb were determined in 12 barbiturate-anesthetized, healthy dogs by stimulating the dorsal roots L1-S3 and recording the evoked-action potentials from each cutaneous nerve. The dogs were then euthanatized, identification of each dorsal root and cutaneous nerve was verified by dissection, and the type of lumbosacral plexus (prefixed, median fixed, or postfixed) was determined. With one exception, the dorsal cutaneous branches and lateral cutaneous branches of L1-L3 originated only from their corresponding spinal nerve roots. The genitofemoral nerve received afferent fibers predominantly from L3-L4 nerve roots. The lateral cutaneous femoral nerve originated from L3-L5 nerve roots, and the saphenous nerve from L4-L6 nerve roots. The proximal caudal cutaneous sural nerve originated from L6-S1. The lateral cutaneous sural nerve originated from L5-S1; the deep and superficial fibular nerves arose primarily from L6-L7. The distal caudal cutaneous sural nerve originated predominantly from L7-S1, and the medial cutaneous tarsal nerve originated from L6-S1. The medial plantar nerve originated predominantly from L6-S1 roots, whereas the lateral plantar nerve originated from L6-S2 roots. The middle clunial nerve received afferent fibers primarily from S1-S2; the caudal clunial nerve received fibers from S1-S3. The caudal cutaneous femoral nerve originated predominantly from L7-S2. The dorsal nerve of the penis originated predominantly from S1-S2, and the superficial perineal nerve originated from S1-S3. One dog had a prefixed plexus, 8 dogs had median-fixed plexuses, and 1 dog had a postfixed plexus.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号