首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Background: Analysis of body fluids includes an estimate of total nucleated cell count (TNCC). Automated methods may enhance the accuracy and timeliness of TNCC results. Objective: The purpose of this report was to assess the ability of the ADVIA 120 hematology analyzer to accurately count nucleated cells in pleural and peritoneal fluids from animals, compared with manual counts. Methods: Pleural and peritoneal fluids submitted in EDTA tubes to our laboratory over a 17‐month period were used in the study. TNCC/μL was determined by a manual method, using a hemocytometer, and by an automated method, using the ADVIA 120. Correlation of results was determined by Passing‐Bablok regression, Bland–Altman plots, and Pearson correlation analysis. Results: Samples from dogs (n=36), cats (n=36), horses (n=59), and alpacas (n=11) were analyzed. High correlation in TNCC between methods was found for peritoneal fluid (n=93, r=.959), pleural fluid (n=49, r=.966), and all fluids combined (n=142, r=.960) (P<.001). Variation between methods was greater in samples with TNCCs<1000/μL (r=.62, P<.001). The ADVIA systematically overestimated the number of cells in all fluid samples by 95 cells/μL (confidence interval=19.2–190.5/μL). Conclusion: The ADVIA 120 reliably determines TNCC in pleural and peritoneal effusions and can be recommended for routine veterinary laboratory analysis.  相似文献   

2.
OBJECTIVE: To determine whether blood lactate values determined in dogs with 4 commercially available point-of-care meters were in agreement with values determined with a critical care laboratory blood analyzer. DESIGN: Prospective study. ANIMALS: 50 dogs evaluated for emergency treatment. PROCEDURES: Blood samples were collected at initial evaluation and processed on 4 point-of-care meters and on a critical care laboratory blood analyzer. RESULTS: All 4 point-of-care lactate meters generated measurements that were in agreement with the hospital's critical care analyzer. Values for agreement (bias) between the 4 point-of-care meters and the critical care analyzer were -0.652 (limits of agreement [LA], -1.958 to 0.654]), -0.670 (LA, -2.110 to 0.769), -0.096 (LA, -2.071 to 1.879), and -0.498 (LA, -2.616 to 1.620), respectively. CONCLUSIONS AND CLINICAL RELEVANCE: Despite its prognostic and therapeutic relevance, blood lactate measurement in dogs has been hampered by the inability to perform the test in a timely fashion. Results of the present study indicated that several handheld point-of-care lactate meters provided results that were in agreement with a laboratory critical care blood analyzer.  相似文献   

3.
Lumbar and cisternal CSF from 31 healthy dogs were analyzed and compared statistically. The mean total protein of the lumbar CSF samples was 28.68 mg/dl; the mean total protein of cisternal CSF was 13.97 mg/dl. The mean total WBC count of lumbar CSF was 0.55 cells/microliter; the mean WBC count of cisternal CSF was 1.45 cells/microliter. Statistical analysis indicated that the protein and WBC differences between the 2 types of CSF were significant (P = less than 0.001 and P = less than 0.01, respectively).  相似文献   

4.
5.
BackgroundCurrent diagnostic evaluation of transudative effusions rarely aids in identifying an underlying etiology. Lipoproteins in the fluid might reflect the site or nature of vessel involvement.ObjectivesImprove the classification and diagnostic utility of pleural and peritoneal transudates in dogs and cats by investigating lipoprotein patterns in effusions. Compare these patterns with other peritonaeal and pleural fluid variables and underlying diseases.AnimalsSamples of transudates and serum from 18 cats and 37 dogs with transudative effusion (total nucleated cell count [TNCC] <5000 cells/μL) were analyzed.MethodsLipoprotein fractions, triglyceride, and cholesterol (CHO) concentrations were prospectively determined in paired fluid and serum samples. Standard fluid measurements were retrospectively collected.ResultsTwo distinct fluid lipoprotein patterns were noted. Fluids rich in VLDL+IDL were associated with chronic kidney disease, acquired portosystemic shunts or protein‐losing enteropathy (group I). Fluids rich in denser lipoproteins were associated with underlying heart disease, caudal vena cava syndrome or intracavitary neoplasia (group II). Group I and group II also had significant differences between fluid concentrations of CHO (x̄ = 8 vs 110 mg/dL) and TP (x̄ = 0.6 vs 3.8 g/dL), respectively. Five peritoneal transudates were triglyceride‐rich (>100 mg/dL) and associated with pancreatitis.Conclusions and Clinical ImportanceProtein‐poor (TP <1.5 g/dL) and protein‐rich (TP >2.5 g/dL) transudates were associated with distinct lipoprotein patterns and specific groups of disease. Effusions secondary to pancreatitis might be transudative and rich in triglycerides.  相似文献   

6.
Mast cells normally are present in equine bronchoalveolar lavage fluid (BALF), but usually represent <2% of all cells in healthy horses. An increased percentage of mast cells has been associated with airway hyperactivity and inflammatory airway diseases, but marked differences are reported between studies in normal and diseased horses. Because an abnormal mast cell count may be of clinical relevance, we compared the ability of a fast Romanowsky method to stain mast cell granules with that of 3 metachromatic stains: automated Romanowsky, May-Grünwald Giemsa, and toluidine blue stains. The BALF cells from 24 horses were studied. A differential cell count was performed blindly on 400 cells. The percentages of mast cells obtained were analyzed by means of repeated-measures analysis of variance and Fischer's PLSD test. The Bland and Altman method was used to assess agreement among stains. The mean percentage of mast cells in BALF was significantly lower with the fast Romanowsky than with the automated Romanowsky, May-Grünwald Giemsa, and toluidine blue stains. With the fast Romanowsky stain, the metachromatic granules of mast cells were not stained, and their identification was based on morphologic criteria. Toluidine blue staining allowed detection of the highest mean percentage of mast cells, but was inadequate for performing a differential cell count on other cell types. In conclusion, fast Romanosky stain may be inadequate for detection of mast cells in equine BALF, whereas automated Romanowsky, May-Grünwald Giemsa, and toluidine blue stains provide metachromatic staining of mast cell granules.  相似文献   

7.
Abstract: Most hand-held medical refractometers have internal scales that limit protein measurement to results ≥ 2.5 g/dL. Tables for conversion of refraction (r) to protein concentration for values as low as 0.1 g/dL were published in the 1960s, but their accuracy for use on body fluids has not been established. The purpose of this study was to assess the reliability of body cavity fluid protein determination by refractometry. We compared the protein concentration of 25 body cavity fluids as determined by 2 Goldberg type hand-held refractometers with results obtained by the biuret method. Published charts converting refraction (r) to protein concentration were used to determine protein concentration in samples with protein <2.5 g/dL. Higher protein values were read directly from the instruments. The range of comparison was limited to ≥ 0.6 g/dL, the lowest concentration of the biuret method's standard curve. Twenty-one peritoneal fluid, 2 pleural fluid and 2 pericardial fluid samples from 16 horses, 5 cattle, 3 dogs, 2 llamas and 1 cat were tested. The results obtained by the two refractometers were closely and linearly related to biuret results (P<.001), with slopes by linear regression analysis close to 1, and correlation coefficients >0.977. Based on this study, the range for quantification of body cavity fluid protein concentration by refractometry can be extended below 2.5 g/dL, allowing for quantitative assessment of most clinical samples.  相似文献   

8.
The measurement of protein concentration in the cerebrospinal fluid is a basic analytical method in neurology. In this study, a pyrogallol red technique using a human albumin calibrator previously validated in human medicine was tested for canine samples, and the results were compared with those obtained using urine test strips. Pyrogallol red significantly (P<0.05) but moderately underestimated purified dog albumin and globulins. The imprecision of the technique was low: intra- and between-series coefficients of variation were 1.6 and 4.3 per cent at protein concentrations of about 0.3 g/litre. Over 49 samples, there was good agreement between the pyrogallol red and test strip results (r=0.63), especially for low and high protein concentrations, but misclassifications were observed with '+' test strip readings.  相似文献   

9.
10.
The aim of this study was to evaluate the influence of two commonly used anticoagulants (K3EDTA and lithium heparin) on refractometric and spectrophotometric measurement of total protein (TP) concentration in equine peritoneal fluid samples. The influence of a commercial solution of K3EDTA, a solution of K3EDTA in distilled water and lithium heparin on the refractometric and spectrophotometric (biuret) quantification of TP content in peritoneal fluid samples was assessed. Total protein concentration measured by refractometry was consistently overestimated in samples with commercial K3EDTA. The solution of K3EDTA in distilled water only caused TP overestimation at high K3EDTA concentrations (>5 micromol/ml). By contrast, lithium heparin did not influence the refractometric values of TP. Neither anticoagulant modified TP values when measured by the biuret method. In conclusion, the use of K3EDTA as anticoagulant may result in a significant overestimation of TP values of peritoneal fluid samples measured by refractometry.  相似文献   

11.
Jinbo  T.  Shimizu  M.  Hayashi  S.  Shida  T.  Sakamoto  T.  Kitao  S.  Yamamoto  S. 《Veterinary research communications》1998,22(3):193-201
Faecal haemoglobin (Hb) concentrations in apparently healthy experimental Beagle dogs and in dogs of various breeds kept in private households or at breeders were measured by reversed passive latex agglutination (RPLA) and enzyme-linked immunosorbent assay (ELISA) in an effort to define the physiological concentrations of faecal Hb in the dog. In 88% (53) of 60 experimental Beagle dogs (30 males and 30 females), the RPLA titres were 1:2 and 1:8 and the faecal Hb concentrations ranged from 40.0 to 431.5 (mean 184.1±92.6) g/g faeces by ELISA. No significant difference was found in Hb levels or RPLA titres between males and females. Seven dogs (12%) had significantly greater RPLA titres and Hb concentrations by ELISA than the remaining dogs. In 84% (45) of the 53 dogs kept in private households or at breeders, the RPLA titres were >1:1 to 1:8 and the faecal Hb concentrations ranged from 7.1 to 456.7 (mean 137.5±128.7) g/g faeces in ELISA. Eight of these dogs (15.1% of 53 dogs) had significantly greater RPLA titres and Hb concentrations by ELISA than the remaining dogs. There were no significant differences between the Beagles and dogs kept in private households or at breeders. In conclusion, in 98 (86.7% of 113) dogs the physiological concentrations of RPLA titres were >1:1 to 1:8 and the faecal Hb concentrations were 143.5–185.1 g/g (95% confidence level). Approximately 13.3% of apparently healthy dogs had higher faecal Hb concentrations, suggesting the presence of subclinical haemorrhages. Four dogs suffering from colorectal cancer also had high faecal Hb concentrations.  相似文献   

12.
13.
14.
OBJECTIVE: To compare plasma (total and unbound) and interstitial fluid (ISF) concentrations of doxycycline and meropenem in dogs following constant rate IV infusion of each drug. ANIMAL: 6 adult Beagles. PROCEDURE: Dogs were given a loading dose of doxycycline and meropenem followed by a constant rate IV infusion of each drug to maintain an 8-hour steady state concentration. Interstitial fluid was collected with an ultrafiltration device. Plasma and ISF were analyzed by high performance liquid chromatography. Protein binding and lipophilicity were determined. Plasma data were analyzed by use of compartmental methods. RESULTS: Compared with meropenem, doxycycline had higher protein binding (11.87% [previously published value] vs 91.75 +/- 0.63%) and lipophilicity (partition coefficients, 0.02 +/- 0.01 vs 0.68 +/- 0.05). A significant difference was found between ISF and plasma total doxycycline concentrations. No significant difference was found between ISF and plasma unbound doxycycline concentrations. Concentrations of meropenem in ISF and plasma (total and unbound) were similar. Plasma half-life, volume of distribution, and clearance were 4.56 +/- 0.57 hours, 0.65 +/- 0.82 L/kg, and 1.66 +/- 2.21 mL/min/kg, respectively, for doxycycline and 0.73 +/- 0.07 hours, 0.34 +/- 0.06 L/kg, and 5.65 +/- 2.76 mL/min/kg, respectively, for meropenem. The ISF half-life of doxycycline and meropenem was 4.94 +/- 0.67 and 2.31 +/- 0.36 hours, respectively. CONCLUSIONS AND CLINICAL RELEVANCE: The extent of protein binding determines distribution of doxycycline and meropenem into ISF. As a result of high protein binding, ISF doxycycline concentrations are lower than plasma total doxycycline concentrations. Concentrations of meropenem in ISF can be predicted from plasma total meropenem concentrations.  相似文献   

15.
16.
17.
It is increasingly important to have simple, non-invasive indicators of stress in animals. Studies in various species have shown that concentrations of cortisol in saliva relate closely to plasma levels of the free hormone; the aim of the present procedure was to show a similar correlation in the dog. Baseline blood and saliva samples were collected concurrently from six male beagles. Synthetic adrenocorticotrophic hormone was given and further samples were collected at 0.25, 0.5, one, two and 2.5 hours later. The results indicated a statistically significant correlation between the levels of cortisol in blood and saliva. Concentrations in saliva were between 5 and 10 per cent of those in plasma at each collection time. To demonstrate a response to a more natural stimulus, saliva samples were taken from a dog during exposure to a known stressor for that individual. The results showed a marked, delayed increase from baseline which was maintained for at least 0.5 hours after stressing.  相似文献   

18.
OBJECTIVES: To determine systemic and local platinum concentrations released from subcutaneously implanted cis-diamminedichloroplatinum (cisplatin) -impregnated polymethylmethacrylate (PMMA) and to evaluate systemic or local adverse reactions. ANIMALS: 6 healthy dogs. PROCEDURE: Cisplatin (20 mg) was inserted into PMMA that was fashioned into cylinders and placed into subcutaneous tissue chambers overlying the thorax (treated site). An empty tissue chamber was placed over the opposite side (control site). Plasma samples were obtained for platinum determination before implantation, at 3, 6, and 12 hours after implantation on day 0, and once daily on days 1, 2, 3, 7, 14, 21, and 29. At similar times on similar days, tissue chamber fluid samples also were obtained for platinum determination. Complete blood count, serum urea nitrogen and creatinine concentration determinations, and urinalyses were performed on days 1, 2, 3, 7, 14, 21, and 29. Complete necropsy was performed at conclusion of the study. RESULTS: Tissue chamber platinum concentrations at the treated site were significantly greater than plasma and control site tissue chamber concentrations on days 2, 3, 7, 10. Mean plasma platinum concentration at 3 (0.735 microg/ml), 6 (0.691 microg/ml), 12 (0.534 microg/ml), 24 (0.131 microg/ml), 48 (0.2 microg/ml), 72 (0.1 microg/ml), and 158 (0.014 microg/ml) hours was significantly greater than pretreatment values (0.0 microg/ml). Plasma platinum concentration 10 days after treatment (0.011 microg/ml) did not significantly differ from pretreatment values. Local or systemic adverse reactions were not apparent. CONCLUSIONS: The route of cisplatin administration was safe. Greater concentration of platinum was released locally relative to plasma concentration for an extended period.  相似文献   

19.
Obesity is considered one of the most common forms of malnutrition occurring in dogs. Laboratory methods of evaluation of body composition in live dogs have included dual-energy X-ray absorptiometry (DEXA) and deuterium oxide (D(2)O) dilution. Clinical methods of evaluation include assigning a body condition score (BCS) based on visual observation, palpation, and morphometric measurements. This study used these four methods to evaluate 23 healthy, adult, client-owned dogs. Good correlation (coefficient of determination [r(2)]=0.78) was found between measurements of percent body fat (%BF) determined by the D(2)O dilution method and the DEXA scan. Percent body fat can also be estimated using BCS (r(2)=0.92 comparison with DEXA) or by using morphometric measurements with simple calculations (r(2)=0.92 comparison with DEXA).  相似文献   

20.
Serum concentrations of total and free thyroxine (T4 and FT4, respectively), 3,5,3'-triiodothyronine (T3), 3,3',5'-triiodothyronine (reverse T3) were measured in 42 dogs with hyperadrenocorticism, and were compared with values determined in clinically normal dogs. Mean total T4 concentration in dogs with hyperadrenocorticism (14.3 nmol/L) was significantly (P less than 0.001) lower than the normal value (25.7 nmol/L), with 38% of the dogs having low serum T4 concentration. Although 16 (38%) of the 42 dogs with hyperadrenocorticism had a high FT4 fraction, indicative of diminished serum T4 binding, normal FT4 concentration was found in only 6 of the 16 dogs (38%) with low total T4 values. Mean serum T3 concentration in dogs with hyperadrenocorticism (0.79 nmol/L) was also significantly (P less than 0.001) lower than the normal value (1.16 nmol/L), with 39% of the dogs having T3 values below the normal range. Individual T3-to-T4 and T3-to-FT4 ratios, indices of T3 production and/or clearance, were above the normal range in 29 and 24% of dogs with hyperadrenocorticism, respectively. Mean reverse T3 concentration in dogs with hyperadrenocorticism (0.17 nmol/L) was also significantly (P less than 0.001) lower than the normal mean value (0.39 nmol/L), with 48% of the dogs having reverse T3 values below the normal range. Of the 21 dogs in which all iodothyronines were measured, 6 (29%) had undetectable values for all hormones.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号