首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Objectives To establish normal reference ranges of ocular parameters including phenol read thread, palpebral fissure length, horizontal and vertical corneal diameter, upright and hanging intraocular pressure (IOP) and to report ophthalmic examination findings of the anterior segment and lens, in a population of captive fruit bats. Animals studied Eyes of 30 bats of three species were included in this study: 10 (5 males, 5 females) Malayan Flying Foxes (Pteropus vampyrus), 10 (5 males, 5 females) Little Golden‐mantled Flying Foxes (Pteropus pumilus), and 10 (4 males, 6 females) Island Flying Foxes (Pteropus hypomelanus). Results The most common ophthalmic examination findings included iris‐iris persistent pupillary membranes (83%), nuclear sclerosis (56.7%), prominent arterial circle (40%), iridal hyperpigmented foci (30%), pupillary margin cysts (27%), and third eyelid defects (20%). The mean, among all species for: phenol red thread was 20.23 ± 1.28 mm/15 s both eyes (OU); palpebral fissure length was 13.34 ± 0.33 mm for OU; for horizontal corneal diameter was 10.72 ± 0.32 mm for OU; for vertical corneal diameter was 9.90 ± 0.30 mm for OU; for the hanging intraocular pressures was 19.38 ± 0.77 mmHg for OU; for upright IOP was 13.95 ± 0.60 mmHg for OU. Measurements for the individual species groups and eyes were also calculated. Conclusions Results revealed the IOP of bats in a hanging position were significantly higher than the IOP of bats in an upright position. The size of the bat, between the species, affected palpebral fissure length, horizontal corneal diameter, and vertical corneal diameter. Information about the ocular structures and normal ophthalmic parameters for the Pteropus species is crucial for species protection because of dependence on vision for survival.  相似文献   

2.
Objective The aim of the study was to assess the ocular features, normal conjunctival bacterial and fungal flora, and intraocular pressure (IOP) in the Canadian beaver (Castor canadensis). Sample population Sixteen, apparently healthy beavers with no evidence of ocular disease, and live‐trapped in regions throughout Prince Edward Island. Procedures The beavers were sedated with intramuscular ketamine (12–15 mg/kg). Two culture specimens were obtained from the ventral conjunctival sac of both eyes of 10/16 beavers for aerobic and anaerobic bacterial and fungal identifications. The anterior ocular structures of all beavers were evaluated using a transilluminator and slit lamp biomicroscope. Palpebral fissure length (11/16 beavers), and horizontal and vertical corneal diameters (10/16 beavers) were measured. IOPs were measured in both eyes of 11/16 beavers using applanation tonometry. Both eyes of 3/16 beavers and one eye of 1/16 beavers were dilated using topical tropicamide prior to sedation to effect timely maximal dilation. Culture specimens and IOPs were not evaluated in these four animals. Indirect ophthalmoscopy was performed on 7/8 eyes of these four beavers. Results Conjunctival specimens from all eyes cultured positively for one or more isolates of aerobic bacteria. The most common isolate was Micrococcus spp. (five beavers; 9/20 eyes). Other isolates included a Gram‐positive coccobacilli‐like organism (four beavers; 7/20 eyes), Aeromonas hydrophila (three beavers; 4/20 eyes), Staphylococcus spp. (three beavers; 4/20 eyes), Gram positive bacilli (one beaver; 2/20 eyes), Enterobacter spp. (two beavers; 2/20 eyes), Streptococcus spp. (two beavers; 2/20 eyes), aerobic diphtheroids (one beaver; 1/20 eyes), and Pseudomonas spp. (one beaver; 1/20 eyes). Clostridium sordellii (one beaver; 1/20 eyes) and Peptostreptococcus spp. (one beaver; 1/20 eyes) were the sole anaerobic bacteria isolated. All conjunctival specimens were negative for growth of fungi. Ophthalmic examinations revealed the normal beaver eye and ocular adnexa included dorsal and ventral puncta, a vestigial third eyelid, and a circular pupil. Average palpebral fissure length was 9.36 mm (SD = 1.00) for both eyes. Mean horizontal and vertical corneal diameters of both eyes were 9.05 mm (SD = 0.64) and 8.45 mm (SD = 0.69), respectively. Mean IOP for the right and left eyes were 17.11 mmHg (SD = 6.39) and 18.79 mmHg (SD = 5.63), respectively. Indirect ophthalmoscopic examinations revealed normal anangiotic retinas. Conclusions Gram‐positive aerobes were most commonly cultured from the conjunctival sac of normal beavers, with Micrococcus spp. predominating. The overall mean IOP in ketamine‐sedated beavers was 17.95 mmHg. The beaver, an amphibious rodent, has an anangiotic retina.  相似文献   

3.
4.

Objective

To characterize the ocular surface parameters and determine the prevalence of ocular pathology in Shih Tzu dogs.

Animal Studied

Fifty Shih Tzu dogs (28 male, 22 female).

Procedures

Each dog underwent a complete ophthalmic examination (recording any pathology) and a series of diagnostics, allowing for a 10 min-interval between tests: intraocular pressure (IOP), blink rate, palpebral fissure length (PFL), corneal tactile sensation (CTS), Schirmer tear test and nasolacrimal reflex without (STT-1, NL-STT1) and with topical anesthesia (STT-2, NL-STT2), tear ferning, strip meniscometry test (SMT), tear film breakup time (TFBUT), and punctate fluorescein staining (PFS) of the cornea.

Results

Mean ± SD test values were as follows: IOP (17.9 ± 3.7 mmHg), blink rate (2.4 ± 1.4 blinks/min), PFL (23.8 ± 1.8 mm), CTS (1.8 ± 0.7 cm), STT-1 (22.0 ± 5.5 mm/min), NL-STT1 (24.2 ± 4.7 mm/min), STT-2 (16.9 ± 6.5 mm/min), NL-STT2 (18.5 ± 7.5 mm/min), SMT (7.5 ± 3.5 mm/5 s), TFBUT (5.3 ± 2.4 s), tear ferning (1.3 ± 0.7), and PFS (1.6 ± 0.6). PFL was significantly greater in male vs. female Shih Tzus (p< .001). Age was negatively correlated with TFBUT results (r = −0.31, p = .027). Lagophthalmos was observed in 82% eyes. Ocular surface pathology was common, including adnexal abnormalities (100% eyes with caruncular trichiasis and medial lower lid entropion) and corneal opacification (27% pigmentation, 20% fibrosis, 12% neovascularization).

Conclusions

Qualitative tear film deficiency (low TFBUT), along with several anatomical abnormalities that promote ocular irritation and reduce globe protection, together help explain the concerningly high prevalence of ocular surface disease in the Shih Tzu breed. Prophylactic measures (e.g., medial canthoplasty, topical lubrication) could be considered to improve ocular health in Shih Tzus.  相似文献   

5.
6.
Objective: To report normal tear production of healthy adult black‐tufted marmosets and propose a novel alternative for the measurement of the aqueous portion of tear production in animals with small eyes. Animal studied: Black‐tufted marmosets (Callithrix penicillata). Procedures: Tear production of 19 animals was evaluated by the following methods: modified Schirmer’s I, phenol red thread and the novel use of standardized endodontic absorbent paper points. These methods and results were compared. Additionally, blink frequency and palpebral fissure length were measured. Results: Modified Schirmer’s test I, mean = ?0.46 ± 3.41 mm/min; Phenol red thread, mean = 13.27 ± 5.41 mm/15 s.; Standardized endodontic paper points, size 30, mean = 9.32 ± 3.09 mm/min; Mean palpebral fissure length = 7.83 ± 0.72 mm. Blink frequency, mean = 20.27 ± 5.92/5 min. Conclusions: Normal parameters for blink frequency, palpebral fissure length and tear production measurement are presented. The palpebral fissure of black‐tufted marmoset is very small and tear production is one of the lowest reported for all animal species. A novel and practical alternative for tear production measurement using standardized endodontic absorbent paper points is presented and is indicated for animals with small eyes.  相似文献   

7.
Effect of body position on intraocular pressure in dogs without glaucoma   总被引:1,自引:0,他引:1  
OBJECTIVE: To determine the effects of body position on intraocular pressure (IOP) in dogs without glaucoma. ANIMALS: 24 healthy dogs with no evidence of glaucoma. PROCEDURES: Dogs underwent ophthalmic examinations to ensure that no IOP-affecting ocular diseases were present. Each dog was sequentially placed in dorsal recumbency, sternal recumbency, and sitting position. For each of the 3 positions, IOP in the right eye was measured by use of an applanation tonometer immediately after positioning (0 minutes) and after 3 and 5 minutes had elapsed. The initial body position was randomly assigned; each position followed the other positions an equal number of times, and IOP measurements were initiated immediately after moving from one body position to the next. Proparacaine hydrochloride (0.5%) was applied to the right eye immediately prior to IOP measurements. RESULTS: Intraocular pressure was affected by body position. During the 5-minute examination, IOP decreased significantly in dogs that were dorsally recumbent or sitting but did not change significantly in dogs that were sternally recumbent. For the 3 positions, overall mean IOP differed significantly at each time point (0, 3, and 5 minutes). Mean IOP in dorsal recumbency was significantly higher than that in sternal recumbency at 0 and at 3 minutes; although the former was also higher than that in sitting position at 3 minutes, that difference was not significant. CONCLUSIONS AND CLINICAL RELEVANCE: Body position affects IOP in dogs. When IOP is measured in dogs, body position should be recorded and consistent among repeat evaluations.  相似文献   

8.
OBJECTIVE: To determine intraocular pressure (IOP) in cats > or = 7 years of age undergoing a routine comprehensive geriatric health examination. DESIGN: Prospective study. ANIMALS: 538 cats (1,068 eyes). PROCEDURE: IOP was measured by applanation tonometry following instillation of 0.5% proparacaine. RESULTS: Mean +/- SD IOP for all eyes was 12.3 +/- 4.0 mm Hg (range, 4 to 31 mm Hg). Mean age was 12.3 +/- 2.9 years. Intraocular pressure did not vary significantly cross-sectionally with age. However, in 78 cats, IOP was measured more than once, and follow-up measurements were significantly less than initial measurements (mean time between measurements, 9.4 +/- 3.0 months). The most useful tonometric criteria for identifying ocular abnormalities on the basis of IOP was an IOP > or = 25 mm Hg (mean + 3 SD) or a difference in IOP between eyes > or = 12 mm Hg. Eight cats met these criteria, and 5 of these cats had ophthalmic abnormalities. Low IOP was a nonspecific indicator of the presence of ocular abnormalities, as 111 cats had an IOP < or = 8 mm Hg, but only 2 had uveitis. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that IOP measurements can be a useful addition to a comprehensive geriatric health examination in cats > or = 7 years of age, especially when combined with an ophthalmic examination. Cats without ocular abnormalities that have lOP > or = 25 mm Hg or a > or = 12 mm Hg difference in IOP between eyes should have tonometry repeated or be referred to an ophthalmologist for further evaluation before beginning antiglaucoma treatment.  相似文献   

9.
OBJECTIVES: To evaluate the tear film qualitatively and conjunctival goblet cell numbers in cats with and without corneal sequestra. ANIMALS STUDIED AND PROCEDURES: This was a prospective evaluation of 11 cats with corneal sequestra and 14 control eyes that were either the contralateral normal eye when the sequestrum was unilateral or from control cats of similar age with no ocular disease. All cats in this study were examined by a veterinary ophthalmologist. The ophthalmic examinations included a neuro-ophthalmic evaluation, Schirmer tear tests, fluorescein staining, tear film break-up times, applanation tonometry, biomicroscopy, and indirect ophthalmoscopy. The palpebral conjunctiva at the dorsal nasal, ventral nasal, dorsal temporal and ventral temporal fornices were biopsied after topical anesthetic was applied to the cornea and conjunctiva. The conjunctival biopsies were fixed in formalin and sectioned routinely and stained with hematoxylin and eosin, and periodic acid-Schiff. These slides were examined by light microscopy by a blinded examiner. Goblet cell numbers were compared to conjunctival basal epithelial cell numbers by region. The goblet cell numbers by region from the eyes with sequestra was statistically compared to those from eyes without sequestra, with a student's paired t-test. Conjunctival swabs were collected from the cats with corneal sequestra and submitted for polymerase chain reaction for Herpes felis, Chlamydia psiitticia, and Mycoplasma felis. The corneal sequestra were removed by surgical keratectomy and fixed and stained routinely, and examined by light microscopy. RESULTS: No neurologic abnormalities were detected in any of the cats. The Schirmer tear tests (eyes with sequestra 14+/-5.1 mm/min; normal eyes 15+/-6.8 mm/min) and intraocular pressures (eyes with sequestra 21+/-6.6; normal eyes 22+/-5.8) were within normal reference ranges for cats. Biomicroscopic examinations revealed varied sizes and depths of brown- and amber-colored corneal sequestra. No abnormalities were noted on indirect ophthalmoscopic examinations. The tear film break-up time was 21 s (+/-12) for the normal eyes (n=14) and 14 s (+/-13) in eyes with corneal sequestra (n=11). The average goblet/epithelial cell ratios by region for the normal eyes and the eyes with sequestra respectively were 0.66, 0.56 for the dorsal nasal fornix, 0.68, 0.57 for the ventral nasal fornix, 0.63, 0.48 for the temporal dorsal fornix, and 0.55, 0.49 for the temporal ventral fornix. There were no significant differences in tear film break-up times and goblet cell numbers in eyes with corneal sequestra and those without sequestra. Three conjunctival swabs from two of 11 cats with sequestra were positive with PCR for Herpes felis virus. These included one cat with bilateral sequestra and one cat with unilateral corneal sequestrum. CONCLUSIONS: The pathogenesis of feline corneal sequestra does not appear to be linked primarily to abnormal goblet cell numbers, qualitative tear film abnormalities, and accelerated tear film break-up time.  相似文献   

10.
OBJECTIVE: To develop and compare 3 techniques for retrobulbar injection of local anesthetic agents for ocular surgery and analgesia in dogs. DESIGN: Prospective study. ANIMALS: 17 dogs (including 9 cadavers). PROCEDURES: Inferior-temporal palpebral (ITP), perimandibular, and combined superior-inferior peribulbar injection techniques were compared by assessing the distribution of latex after injection into the orbits of 5 canine cadavers; magnetic resonance imaging (MRI) evaluation of the distribution of contrast agent after injection in the retrobulbar space of 4 canine cadavers; and assessment of the efficacy and MRI evaluation of the anatomic distribution of injections of a lidocainecontrast agent mixture in 4 anesthetized, nonrecovery dogs. By use of the preferred technique (ITP), the ocular effects of lidocaine anesthesia were evaluated in 4 dogs; during a 2-week period after treatment, dogs underwent ophthalmic examination, Schirmer tear testing (STT), intraocular pressure (IOP) measurement, and Cochet-Bonnet esthesiometry. RESULTS: Of the 3 techniques, the ITP technique was the preferred method for retrobulbar administration of anesthetic agent in dogs because it was efficacious (pupil dilation and central rotation of the globe achieved in all eyes), easiest to perform, and provided thorough coverage of the intraconal retrobulbar space without complication. During the 2-week follow-up period, the ITP injection did not significantly affect STT, IOP, or Cochet-Bonnet esthesiometry values in dogs. CONCLUSIONS AND CLINICAL RELEVANCE: In dogs, retrobulbar administration of anesthetic agents via the ITP technique is a potential alternative to systemic administration of neuromuscular blocking agents for ophthalmic surgery and provides the additional benefit of local ocular analgesia.  相似文献   

11.
OBJECTIVE: To establish the central corneal thickness (CCT) of normal koi fish by ultrasonic pachymetry, and its relationship to age, sex, body length and corneal diameter. METHODS: Age, sex and body length of 33 koi fish (17 male and 16 female fish) were recorded. Horizontal and vertical corneal diameters of each eye were obtained using Jameson calipers. Central corneal thickness of all eyes was measured by ultrasonic pachymetry. Intraocular pressure (IOP) by rebound tonometry was obtained for a subgroup of nine koi (18 eyes). RESULTS: Mean central corneal thickness was 325.9 microm. Central corneal thickness of female koi was greater than CCT of male fish (P < 0.01). Central corneal thickness increased with increasing age overall and within both sexes (P < 0.01). Central corneal thickness increased with increasing body length (P < 0.001). For male and female fish, CCT increased with increasing horizontal and vertical corneal diameters (P < 0.01). Mean horizontal corneal diameter (HCD) was 8.05 mm, mean vertical corneal diameter (VCD) was 7.38 mm, and HCD was consistently greater than VCD. Mean IOP of a subgroup of these koi was 4.9 mmHg by rebound tonometry. CONCLUSIONS: Koi CCT increases with increasing age, body length and corneal diameter.  相似文献   

12.
Ophthalmic examination findings in adult pygmy goats (Capra hicus)   总被引:1,自引:1,他引:0  
Objective To document normal ophthalmic findings and ocular abnormalities in captive adult pygmy goats. Animals studied Ten healthy adult pygmy goats (five male, five female; 5–11 years of age; 26–45 kg body mass) underwent complete ophthalmic examinations. Procedure Direct illumination, diffuse and slit‐beam biomicroscopy, indirect ophthalmoscopy, IOP measurements and Schirmer tear tests were performed. TonoVet® rebound tonometry, followed by topical application of 0.5% ophthalmic proparacaine, and Tono‐Pen XL® applanation tonometry were performed in each eye to obtain estimates of IOP. Results Ophthalmic abnormalities included corneal scars and pigmentation, incipient cataracts, lenticular sclerosis, and vitreal veiling. Mean STT values were 15.8 mm/min, with a range of 10–30 mm/min. Mean IOP values were 11.8 mmHg for TonoVet®‐D, with a range of 9–14 mmHg; 7.9 mmHg for TonoVet®‐P, with a range of 6–12 mmHg; and 10.8 mmHg for Tono‐Pen XL®, with a range of 8–14 mmHg. Conclusions Ophthalmic examination findings in adult pygmy goats, including normal means and ranges for STT and IOP measurements, using applanation and rebound tonometry, are provided.  相似文献   

13.
Objective To report ophthalmic findings in the Screech owl (Megascops asio). Sample population Twenty‐three, apparently healthy adult captive Screech owls in Maryland. Procedures OU of all owls underwent complete ophthalmic examination. One randomly assigned eye of each bird was measured by phenol red thread tear test (PRT), and the other eye by Schirmer tear test (STT). TonoVet® rebound tonometry and TonoPen‐XL® applanation tonometry were performed in each eye to measure IOP. Conjunctival swabs were cultured from one eye of 10 birds, corneal diameter was measured in OU of eight birds, and streak retinoscopy was performed on OU of seven birds. Ten birds were anesthetized, and A‐scan ultrasonography using a 15‐MHz probe was performed to obtain axial intraocular measurements. Results Ophthalmic abnormalities were noted in 24/46 (52%) of eyes. Median STT result was ≤ 2 mm/min, ranging ≤ 2–6 mm/min, and mean ± SD PRT was 15 ± 4.3 mm/15 s. Mean ± SD IOP were 9 ± 1.8 mmHg TonoVet®‐P, 14 ± 2.4 mmHg TonoVet®‐D, and 11 ± 1.9 mmHg TonoPen‐XL®. Coagulase negative staphylococcal organisms were cultured from all conjunctival swabs. Mean ± SD corneal dimensions were 14.5 ± 0.5 mm vertically and 15.25 ± 0.5 mm horizontally. All refracted birds were within one diopter of emmetropia. Mean ± SD axial distance from the cornea to the anterior lens capsule was 4.03 ± 0.3 mm, from cornea to the posterior lens capsule was 10.8 ± 0.5 mm, and from cornea to sclera was 20.33 ± 0.6 mm. Conclusions This study reports ophthalmic examination findings in Screech owls, and provide means and ranges for various ocular measurements. This is the first report of rebound tonometry and PRT in owls.  相似文献   

14.
Objective To establish reference values for the Schirmer tear test I (STT I), the phenol red thread tear test (PRTT), the intraocular pressure (IOP) with rebound tonometry, to determine the corneal sensitivity for healthy chinchillas, and to describe clinical aspects of normal chinchilla eyes. Animals One hundred and twenty‐two eyes of 61 healthy pet chinchillas of different age and gender were investigated. Procedures A full ophthalmic exam including slit lamp biomicroscopy, ophthalmoscopy, measurement of STT I, PRTT, determination of the corneal touch threshold (CTT), and the measurement of the IOP (TonoVet®) was performed. The normal appearance of the lid, the iris, the lens, the fundus, and the optic nerve disc was evaluated. Results The results of the STT I were very low and not reliable, and the measurement was discontinued. The median value of PRTT was 14.0 mm wetting/15 s (mean 14.6 ± 3.5 mm wetting/15 s). The median CTT was 32.5 mm (mean 31.2 ± 7.0 mm) respectively 1.2 g/mm2 (mean 1.5 ± 0.9 g/mm2). The median IOP was 3.0 mmHg (mean 2.9 ± 1.8 mmHg). The predominating iris color was brown. The fundus pigmentation varied. Few lens alteration were seen in otherwise healthy chinchilla eyes. Most chinchillas had myelinated discs. Optic nerve cupping was present in 62% of the animals. Conclusion Because of the small amount of tears, the PRT test is recommended for tear measurements in chinchillas. The IOP in chinchillas seems to be quiet is low in comparison to other rodents.  相似文献   

15.
Purpose To determine the normal reference range for Schirmer tear test (STT) values in clinically normal llamas (Lama glama) Animals Nine captive llamas (Lama glama) (seven females and two males) were used in this study. Procedure Complete ophthalmic examinations were performed without chemical restraint. STT I values were evaluated in both eyes of all llamas using a commercial STT strip of a single lot number (Schirmer‐Tränentest®, Germany). STT II value was also measured in both eyes of seven female llamas. Results No statistically significant differences among ages or between right and left eyes were found for any of the results. The mean ± SD STT I of 18 eyes of nine llamas was 17.3 ± 1.1 mm/min (Range 15–19 mm/min). The mean ± SD STT II of 14 eyes of seven llamas was 15.4 ± 1.7 mm/min (Range 12.5–17.5 mm/min). A paired samples t‐test demonstrated that there was a significant difference between the STT I and II values (P = 0.001). Conclusion This study provides novel data for normal reference ranges of STT I and II values in healthy llamas. Results of this study may assist veterinarians in the diagnosis of ocular surface disease and syndromes affecting the tear film in these species.  相似文献   

16.
OBJECTIVE: To determine corneal thickness, intraocular pressure (IOP), and horizontal and vertical corneal diameter (HCD and VCD) and to obtain axial measurements of the anterior chamber depth (ACD), crystalline lens thickness (CLT), vitreous chamber depth (VtCD), and axial globe length (AGL) in eyes of Miniature Horses. ANIMALS: 41 healthy Miniature Horses. PROCEDURE: Ocular component measurements were obtained via ultrasonic pachymetry, applanation tonometry, ultrasound, and by use of a Jameson caliper. RESULTS: Mean IOP and corneal thickness for all eyes were 26.0 mm Hg and 785.6 microm, respectively. There was no correlation of age with IOP or corneal thickness and no difference in these variables between right and left eyes or between females and males. Mean HCD andVCD were 25.8 and 19.4 mm, respectively; although there were no differences between sexes or between right and left eyes, there was positive correlation of optical corneal diameters with increasing age. Mean ACD, CLT, VtCD, and AGL were smaller in Miniature Horses (5.6, 10.0, 18.1, and 33.7 mm, respectively), compared with values for full-sized horses; there was no difference in these variables between sexes or between right and left eyes in Miniature Horses, but they were correlated with increasing age. CONCLUSIONS AND CLINICAL RELEVANCE: In Miniature Horses, corneal thickness and IOP are similar to values reported for full-sized horses and do not increase with advancing age. Vertical corneal diameter, HCD, and AGL increase until 5, 7, and 2 years of age, respectively.  相似文献   

17.
Objective The present study was undertaken to establish reference values for Schirmer tear test (STT) and intraocular pressure (IOP) in the long‐eared hedgehog (Hemiechinus auritus). Animals Fourteen healthy long‐eared hedgehogs (H. auritus) of either sex were studied. Procedures The hedgehogs were individually immobilized with an intramuscular injection of combined Ketamine (20 mg/kg) and Diazepam (0.5 mg/kg), and each animal underwent ophthalmic examinations including: STT, tonometry, biomicroscopy, and indirect ophthalmoscopy. Results No significant effects of animal gender, weight, side (right vs. left eye) were found in this study. Mean (SD) STT values for all eyes (n = 28) were 1.7 ± 1.2 mm/1 min with a range of 0–4 mm/1 min. Mean STT in male animals was 2.2 ± 1.2. Mean STT in female Hedgehogs was 1.3 ± 1.1. Mean (SD) IOP values by applanation tonometry were 20.1 ± 4.0 mmHg (range 11.5–26.5 mmHg). Mean (SD) IOP values by applanation tonometry were 18.2 ± 4.0 and 22.0 ± 3.2 mmHg for males and females, respectively. Conclusions This study reports STT and IOP findings in long‐eared hedgehogs (H. auritus).  相似文献   

18.
Effects of topical administration of 1% brinzolamide on normal cat eyes   总被引:1,自引:0,他引:1  
Objective To evaluate the effect of short‐term daily topical administration of 1% brinzolamide on the intraocular pressure (IOP) of healthy domestic cats with normotensive eyes and to assess the potential for negative side effects of drug administration. Animals Twelve privately owned adult domestic cats without physical or ocular abnormalities. Procedure Normal variation in IOP was determined on day 1. Cats were then treated on days 2–8 with a topical placebo (artificial tear solution) OU q 12 h. On days 9–15 the cats were treated q 12 h with 1% brinzolamide in one randomly selected eye and the placebo in the contralateral eye. All medications (drug and placebo) were administered twice daily at 7 a.m. and 7 p.m. On days 16–22 the cats received no topical medications. IOP, horizontal pupil size in mm and assessment of conjunctival hyperemia were noted OU on days 1, 8, 15 and 22 at 5 time points (9 a.m., 11 a.m., 1 p.m., 3 p.m. and 5 p.m.). Mixed linear regression models were used to compare the IOP of each eye at all time periods for each cat, controlling for age and weight. Results Mean IOP was not significantly altered in any eye at any time point during the treatment period compared with pretreatment, baseline, or follow‐up evaluations. Conjunctival hyperemia and miosis were not detected in either eye at any time point. Conclusions and clinical relevance Short‐term q 12 h administration of 1% brinzolamide did not significantly reduce IOP in this small sample population of normotensive cats under these study conditions. No clinically relevant side effects were noted with brinzolamide administration.  相似文献   

19.
The purpose of this study was to establish normal physiologic reference values for intraocular pressure (IOP) and Schirmer tear test (STT) results in clinically normal ostriches (Struthio camelus). Twenty ostriches of both sexes, 10 juveniles (1.5-2 yr of age) and 10 adults, were included in this study. Complete ophthalmic examination was performed prior to this investigation. STT was performed by inserting a standard sterile STT strip over the ventral lid margin into the ventral conjunctival sac for 60 sec. Following the STT, IOP was measured using applanation tonometry with the Tono-Pen Vet tonometer after topical instillation of one drop of 0.5% proparacaine ophthalmic solution. The mean +/- SD and range of Tono-Pen readings of IOP for all birds was 18.8 +/- 3.5, with a range of 12-24. Mean IOP in juvenile ostriches was 19.7 +/- 3.6. Mean IOP in adult ostriches was 16.9 +/- 2.9. There was no statistically significant difference between young and adult birds (P = 0.07). The mean STT values in the present study were 16.3 +/- 2.5 mm/1 min when measurements from both eyes were averaged. Mean STT in juvenile and adult ostriches was 15.4 +/- 1.8 and 17.2 +/- 2.9 mm/1 min, respectively. There was no statistically significant difference between young and adult birds (P = 0.11). No statistically significant differences between genders were found for any of the results (P > or = 0.41). In conclusion, this study provides normal reference range values for STT and IOP in clinically healthy ostriches.  相似文献   

20.
OBJECTIVE-To report values for tear production, central corneal touch threshold (CTT), and intraocular pressure (IOP) in healthy guinea pigs and determine results of aerobic bacterial culture and cytologic examination of conjunctival swab specimens. DESIGN-Cross-sectional study. ANIMALS-31 Healthy guinea pigs (62 eyes) of various ages and breeds. PROCEDURES-Tear production was measured by the phenol red thread tear test (PRT) and Schirmer tear test (STT) before and after topical anesthetic application, CTT was measured with an esthesiometer, and IOP was measured by applanation tonometry. RESULTS-Combining data from all eyes, mean +/- SD PRT values before and after topical anesthetic administration were 21.26 +/- 4.19 mm/15 s and 22.47 +/- 3.31 mm/15 s, respectively, and mean IOP was 18.27 +/- 4.55 mm Hg. Median STT values before and after topical anesthetic administration were 3 mm/min (range, 0 to 12 mm/min) and 4 mm/min (range, 0 to 11 mm/min), respectively, and median CTT was 2.0 cm (range, 0.5 to 3.0 cm). Values did not differ between eyes for any test, but significant differences were identified for PRT values between males and females and between values obtained before and after topical anesthetic administration. Common bacterial isolates included Corynebacterium spp, Streptococcus spp, and Staphylococcus spp. Cytologic examination of conjunctival swab specimens revealed mainly basal epithelial cells; lymphocytes were common. CONCLUSIONS AND CLINICAL RELEVANCE-Results provided information on values for PRT, STT, CTT, and IOP in healthy guinea pigs and on expected findings for aerobic bacterial culture and cytologic examination of conjunctival swab specimens.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号