首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
OBJECTIVE: To describe use of the scrotum as a pedicle flap to cover defects created by tumor excision in the perineum or caudal and medial aspect of the thigh. STUDY DESIGN: Clinical study. ANIMALS: Three dogs. METHODS: After tumor excision and prescrotal castration, an incision was made around the base of the scrotum, leaving a pedicle on the side opposite the skin defect. After removal of the tunica dartos and abdominal fascia, the scrotal skin was stretched and shaped to the defect, then sutured in position with a simple interrupted pattern. Bandages that were changed every 48 hours compressed the flaps, and healing was observed until sutures were removed. RESULTS: Two dogs had first intention healing in 15 days, whereas 1 dog developed necrosis of 10% of the flap, and this area healed by second intention. CONCLUSION: In male dogs, the scrotal skin can be used as a pedicle flap for reconstructive surgery of wounds in the perineum and the proximomedial and caudal aspect of the thigh. CLINICAL RELEVANCE: The perineal region remains a surgical challenge because of the lack of the available skin for reconstruction of surgical wounds. The scrotal skin should be considered for use as a transposition flap to cover skin defects in this region.  相似文献   

2.
Skin fold advancement flaps can be created from the elbow and flank folds to close large wounds in the pectoral and inguinal regions of cats and dogs, respectively. The attachments of the laterally facing (outer) and medially facing (inner) layers of the skin fold to the adjacent limb are divided to produce a U-shaped pedicle graft attached to the trunk. This mobilizes skin that can be advanced over large wounds involving the ventral chest or abdomen, or both. The use of skin fold advancement flaps enables direct closure of large skin defects without undue tension and without compromising the mobility of the adjacent limb.  相似文献   

3.
Skin defects on the distal extremities of six dogs were reconstructed with free vascular cutaneous transfers by microvascular anastomosis. The donor flaps were based on the superficial cervical artery and vein. In five of the dogs, bone was exposed and skin was lost from half of the circumference of the limb. Two had infected fractures with sequestra and three had acute shearing injuries. The sixth dog had sensory denervation of the left antebrachium and a carpal acral lick granuloma. Before surgery, the patency of potential recipient vessels was confirmed with arteriography in five dogs and an ultrasonic doppler in one dog. Microvascular technique was used to reestablish circulation to the flaps after they were transferred to the recipient site. Total ischemic time of the flaps averaged 100 minutes. All flaps survived. Successful reconstruction of the cutaneous defects was achieved in these six cases.  相似文献   

4.
Reconstruction of facial defects can be very challenging, even in the hands of an experienced surgeon. Most defects can be repaired using local available tissues. Lip defects can be reconstructed using geometric closure techniques and advancement of local tissues. Forehead defects can be reconstructed using skin grafts, caudal auricular flaps, or rotational or transposition flaps. Care must be taken to minimize tension on eyelids and maintain the integrity of the facial nerve. Cheek defects can be reconstructed using local advancement, superficial temporal, omocervical, and caudal auricular flaps. The bridge of the nose can be very difficult to reconstruct due to a paucity of local tissues; however, skin grafts, indirect pedicle flaps, and superficial temporal flaps can be considered. .  相似文献   

5.
Therapeutic ultrasound (1.5 W/cm2) was investigated for its effect upon testicular size and consistency and semen quality in five dogs. Dogs were treated every other day with a total of three treatments and were examined up to 2 weeks after treatment. There was some tenderness after treatment and a significant decrease in testicular size and semen quality. This method may provide a suitable contraception technique in dogs and requires further investigation.  相似文献   

6.
The treatment of large skin defects of the distal limbs of dogs and cats can be difficult due to the lack of skin available for primary wound closure or the creation of local skin flaps. Distant pedicle skin flaps provide an acceptable alternative for wound closure with full thickness skin and provide a cosmetic result. Fourteen animals (10 dogs and four cats) that had distant pedicle skin flaps are reviewed. The technique allowed 100 per cent wound coverage in 10 of 14 animals and greater than 95 per cent skin flap survival occurred in 12 of 14 animals. Complications associated with the procedure were most commonly wound infection and partial suture line dehiscence, however these did not detract from the final outcome. Flap release was in one or two stages, however the outcomes did not appear to be affected by the release protocol.  相似文献   

7.
OBJECTIVE: To describe the use of skin-fold advancement flaps for covering large skin defects in dogs and cats. STUDY DESIGN: Clinical study. ANIMALS: Eight client-owned animals: 6 dogs and 2 cats. METHODS: Six dogs and 2 cats underwent reconstruction of soft-tissue wounds resulting from traumatic, neoplastic, or infectious lesions. Skin-fold flaps were created by division of the medial and lateral attachment to the proximal limb or the dorsal and ventral attachment to the trunk, enabling closure of adjacent defects on the trunk or proximal limb, respectively. RESULTS: Skin-fold flaps proved effective for closing defects in all animals. Necrosis of a portion of the flap occurred in 2 dogs due to technical errors, but the resultant defects remained amenable to primary closure. All wounds ultimately healed primarily, without major complications. CONCLUSION AND CLINICAL RELEVANCE: The skin-fold advancement flap is a versatile technique that lends itself to use in a variety of locations, depending on which attachments are divided. The clinical results are comparable with those reported for axial pattern and subdermal plexus flaps.  相似文献   

8.
The ability of the SAV 6 high-frequency jet ventilator to effectively ventilate three anesthetized, paralyzed cats (3.2–4.2 kg), two small dogs (7.2 and 10.0 kg), six medium-sized dogs (20.5–25.0 kg), and three large dogs (36.0–43.0 kg) via a 14-gauge (dogs) or a 16-gauge (cats) catheter placed percutaneously into the trachea via the cricothyroid membrane or into a preplaced endotracheal tube was evaluated. The lowest driving pressure within the range of 0.25 to 2.0 kg/cm2 (1 kg/cm2= 14.2 psi) and the highest cycle rate within the range of 60 to 240 per minute that would generate a PaCO2 of 30 ± 3 mm Hg were determined.
All animals could be ventilated to a PaC02 of 30 ± 3 mm Hg by the endotracheal tube and transtracheal route, except the largest dogs, which couid be ventilated to an average PaC02 of 36 mm Hg by the transtracheal route. The transtracheal route consistently required higher driving pressures and lower cycle rates than did the endotracheal tube route. Cats could be ventilated with a driving pressure of 0.25 kg/cm2; small dogs could be ventilated with 0.5 to 1.0 kg/cm2; medium-sized dogs with 1.0 to 1.5 kg/cm2; and large dogs with 1.5 to 2.0 kg/cm2.
The SAV 6 high-frequency jet ventilator can effectively ventilate cats and dogs (7.2–43.0 kg) via a transtracheal catheter and an endotracheal tube.  相似文献   

9.
We assessed whether saline, sterile water, or air better maintained filling volume and diameter in a veterinary silicone Foley bulb. The bulbs of 45 8-French silicone Foley catheters were inflated: 15 with 5 mL of sterile water (SW bulbs), 15 with 0.9% saline (S bulbs), and 15 with air (A bulbs). The bulbs were submerged in 30 mL of synthetic urine in a 50 mL conical tube in a 38°C water bath. Five catheters from each group were removed on days 3, 5, and 10 to measure bulb volume and diameter. On days 3 and 5, volume and diameter of SW or S bulbs were significantly greater than those of A bulbs, but were not significantly different from one another. At day 10, only 1 S bulb remained intact, 4 of the 5 SW bulbs were intact, the average volume of the SW bulbs was 2.8 mL, and the A bulbs were all deflated. We conclude that sterile water and 0.9% saline are both acceptable for Foley bulb inflation of 5 d or less, but sterile water might be preferred if bulb inflation must be maintained for more than 5 d.  相似文献   

10.
OBJECTIVE: To evaluate the use of subdermal plexus skin flaps for closing defects after excision of cutaneous and subcutaneous tumors in dogs and to compare outcome of flaps secured with sutures and those secured with butyl-cyanoacrylate and intermittent sutures. STUDY DESIGN: Clinical study. ANIMALS: Fifteen dogs. METHODS: After excision of cutaneous or subcutaneous tumors the skin defect was reconstructed by random flaps based on the subdermal plexus. Flap skin edges were apposed with simple interrupted 4-0 monofilament nylon sutures (group 1; 5 dogs) or nylon sutures alternated with butyl-cyanoacrylate adhesive (group 2; 10 dogs). Flaps were evaluated every 48 hours when bandages were changed, until complete healing. RESULTS: Random flaps based on the subdermal plexus were effectively used to close wound defects; mean flap survival was 89%. Partial flap necrosis occurred in 4 dogs. Wound margins apposed with butyl-cyanoacrylate had thinner and more esthetic scars than sutured margins. CONCLUSION: Random flaps based on the subdermal plexus proved to be versatile for covering limb wounds after excision of cutaneous or subcutaneous tumors. Mean survival rate was comparable to that reported for axial pattern flaps. Butyl-cyanoacrylate adhesive was easy to apply, allowed accurate margin apposition with good cosmetic outcome and reduced sutures needed. CLINICAL RELEVANCE: Cyanoacrylate adhesive should be considered in lieu of suture closure to secure random skin flaps based on the subdermal plexus in dogs.  相似文献   

11.
Objective— To determine differences in bacterial strike-through for materials commonly used to cover the distal aspect of the pelvic limb during operative site preparation.
Study Design— Randomized block design; ex vivo model.
Animals— Canine cadaveric pelvic limbs (n=40).
Methods— Pelvic limbs (n=40) were randomly assigned to 4 treatment groups: Group 1=Vetrap+sterile Coban; Group 2=latex glove+Vetrap+sterile Coban; Group 3=latex glove+Vetrap+sterile Coban+sterile latex glove+sterile Coban; and Group 4=latex glove+Vetrap+sterile disposable drape+sterile Coban. Limbs were contaminated with a standardized bacterial solution and routinely prepared using the assigned distal leg wrap. Bandages were fluid challenged with a saline (0.9% NaCl) solution-soaked laparotomy sponge for 30 seconds. The wrap surface was sampled for microbial culture before surgical preparation, immediately after, and 60 minutes after applying a sterile leg wrap.
Results— Bacterial growth occurred in all Group 1 cultures, 90% of Group 2 cultures, and none of the Group 3 and 4 cultures, 60 minutes after applying the sterile wrap.
Conclusion— A distal leg wrap of Vetrap+sterile Coban is not effective in preventing bacterial strike-through.
Clinical Relevance— If similar results occur in the live animal, then a sterile impermeable barrier must be incorporated into the distal leg wrap to prevent bacterial strike-through.  相似文献   

12.
Dogs received either 4 mg/kg of prednisone or sterile saline daily for 32 days. Serum samples were assayed every 4 days for total alkaline phosphatase (ALP) and corticosteroid-induced ALP isoenzyme (CIALP) activity. The initial and major increase of serum ALP was attributed to the liver isoenzyme of ALP (LALP), however, CIALP began to increase by day 8 and was significantly increased by day 24. Prior to treatment and on day 32, sections of liver from control and prednisone-treated dogs were stained for ALP activity after blocking the staining activity of LALP with levamisole. The staining activity of CIALP was compared to the staining activity of LALP in liver sections from control dogs and from dogs in which the bile duct was ligated. It was determined that CIALP was located in that area of the hepatocyte membranes which comprise the bile canaliculi.  相似文献   

13.
To document the magnitude of temperature elevation obtained with heated lavage solutions during abdominal lavage, 18 dogs were lavaged with sterile isotonic saline intraoperatively (i.e., during a celiotomy). In nine dogs, room-temperature saline was used. In the remaining nine dogs, saline heated to 43+/-2 degrees C (110+/-4 degrees F) was used. Esophageal, rectal, and tympanic temperatures were recorded every 60 seconds for 15 minutes after initiation of the lavage. Temperature levels decreased in dogs lavaged with room-temperature saline. Temperature levels increased significantly in dogs lavaged with heated saline after 2 to 6 minutes of lavage, and temperatures continued to increase throughout the 15-minute lavage period.  相似文献   

14.
This study investigated the pharmacokinetics of morphine sulphate in an injectable chitosan-based gel. Gels were made from a combination of N-O-carboxymethylchitosan (NOCC) and chitosan and were easily injectable via a 22 gauge needle and appeared stable during long-term storage. Groups of six beagles were injected subcutaneously (s.c.) with 1.2 mg/kg morphine sulphate, either in sterile saline or in sterilized gels, and serial blood samples were withdrawn via a jugular catheter and later analysed for morphine concentrations using radioimmunoassay. Data were analysed according to non-compartmental pharmacokinetics. NOCC-based gels resulted in significantly lower serum morphine concentrations at 10 and 30 min following injection but significantly higher concentrations at all points from 120 to 480 min post-injection. Dogs receiving morphine gel exhibited equivalent or lesser variability in serum morphine concentrations than dogs receiving conventional morphine sulphate. Pharmacokinetic analysis revealed that morphine release from the gel matrix was significantly prolonged but fully bioavailable. There were no significant differences in either distribution ( V d) or terminal elimination ( t 1/2). Dogs experienced no adverse effects other than those normally associated with morphine administration at the time of injection but all dogs receiving the gel presented with an undefined stiffness the next day that resolved spontaneously within 48 h. We conclude that carboxymethylchitosan-based gels hold considerable promise for the development of injectable sustained-release formulations of opioid analgesics.  相似文献   

15.
Latissimus dorsi and cutaneous trunci myocutaneous flaps of equal dimension and location were randomly elevated on opposite sides of the thorax in 10 dogs (group 1) and resutured to their respective bed. The procedure was repeated in four additional dogs (group 2); however, the short perforating branches of the thoracodorsal artery and vein were divided at the base of each cutaneous trunci myocutaneous flap, whereas the cutaneous pedicle and underlying cutaneous trunci muscle were divided in the latissimus dorsi myocutaneous flaps to determine subsequent skin survivability and the major source of circulation of each myocutaneous flap. There was little difference in the percentage of skin survival between the latissimus dorsi and cutaneous trunci myocutaneous flaps in group 1 dogs. Circulation to the "skin island" of group 2 latissimus dorsi myocutaneous flaps originated from intramuscular anastomotic connections between the major branch of the thoracodorsal artery entering the latissimus dorsi muscle and the proximal lateral intercostal arteries perforating the muscle. Ligation of the short perforating branches of the thoracodorsal artery resulted in partial skin necrosis in all group 2 cutaneous trunci myocutaneous flaps. Results from this study indicate that it is unnecessary to elevate the latissimus dorsi muscle for major skin flap elevation and survival. The thicker latissimus dorsi myocutaneous flap is more difficult to develop surgically and appears to have no clinical major advantage over the more mobile cutaneous trunci myocutaneous flap or the adjacent thoracodorsal axial pattern flap for closure of large skin defects within the radius of flap rotation.  相似文献   

16.
In phase I, tissue expanders were implanted subcutaneously over the lateral crural region of four dogs. The expanders were inflated daily to maintain a constant intraluminal pressure for 7 days. All animals tolerated the pressurized expanders well. Some animal patient discomfort was associated with repeated injections into the subcutaneous filling port. One dog developed a limited area of tissue loss and exposure of the expander. Tissue response to the expanders included epidermal hyperplasia, dermal collagen compression with early fibroplasia, and subcutaneous granulation tissue formation adjacent to the expander pocket. In phase II, a second group of four dogs underwent rapid skin expansion over 7 days. The pressure applied to the expanding skin was determined daily and adjusted to approximate the value reported for capillary pressure in the dog. Tissue discoloration occurred in two dogs, suggestive of impaired circulation. Skin flaps were developed from expanded skin and rotated over the talocrural region. Wound dehiscence occurred along the distal flap margin in three phase II dogs. These wounds healed by second intention. Branches of the caudal saphenous artery were identified, using angiography, as the primary blood supply to the skin flaps.  相似文献   

17.
Transepidermal water loss (TEWL) was measured as assessment of barrier function in house dust mite-sensitized atopic ( n  = 24) and normal ( n  = 21) beagle dogs before and after allergen challenge. Dogs of the two groups were matched for age and housed in the same environment. Ten sites were evaluated including both areas of high and low predisposition to atopic lesion formation. On day 0 (before allergen exposure) and day 3 (3 days after allergen exposure), TEWL measurements were taken using an open-chamber evaporimeter. On day 0, significant differences (one-way ANOVA) were found between normal and atopic dogs in the chin, pinna, periocular region, axilla, antebrachium and thorax. Within the atopic group, a significant increase (one-way ANOVA) in TEWL was found in the axilla on day 3. Such a difference was particularly marked in young dogs (chin, pinna, axilla, antebrachium and groin). Within the normal group, allergen challenge did not change TEWL except for the chin. When atopic and nonatopic sites were compared within the atopic group, a significant difference in TEWL was found on day 0. A two-way ANOVA showed a significant effect of site, a significant effect of time but no site × time (i.e. allergen exposure) interaction. It is concluded that the house dust mite-sensitized atopic beagle dogs used in this study have altered barrier function in 'atopic' areas and that such differences are more evident in young individuals and are aggravated by allergen exposure.  相似文献   

18.
Subcutaneous pedicle flaps were created in 21 dogs, 1) with an intact underlying panniculus muscle, 2) with a severed panniculus muscle, and 3) devoid of an underlying panniculus muscle. The survival rates of the resultant grafts were evaluated over a minimum of ten days. All 19 subcutaneous pedicle flaps survived when the underlying panniculus muscle was intact. Nineteen of 23 flaps with a severed panniculus muscle, however, developed necrosis. The survival rates between these two groups were significantly different (p < 0.01). Eight of 14 flaps developed without an underlying panniculus muscle underwent necrosis. Their survival rate was significantly different from flaps with an intact panniculus muscle (p < 0.01) but not significantly different from flaps without an intact panniculus muscle (p < 0.1). Four of 23 subcutaneous pedicle flaps with severed panniculus muscles and six of 14 flaps without an underlying panniculus muscle survived, despite apparent vascular compromise. Six of these grafts survived by accidental incorporation of a direct cutaneous artery and vein beneath the graft. Results from this experiment indicate that subcutaneous pedicle flap development in the dog has a high incidence of necrosis unless a panniculus pedicle to the overlying skin is preserved. As such, they have no advantage in the dog over safer and simpler closure techniques, which preserve the cutaneous circulation.  相似文献   

19.
Objective— To evaluate the efficacy of a surgically placed, static hydraulic urethral sphincter (SHUS) for treatment of urethral sphincter mechanism incompetency (USMI).
Study Design— Prospective study.
Animals— Spayed female dogs (n=4) with acquired USMI.
Methods— Urinary incontinence was assessed using a subjective continence score before and after implantation of an SHUS on the proximal urethra via ventral median celiotomy. Dogs were assessed for urinary continence, urinary tract infections, and implant-associated complications for 30 months. Residual incontinence was treated with percutaneous inflation of the SHUS with sterile saline solution through a biocompatible subcutaneous administration port.
Results— At last follow-up (26–30 months after surgery), continence scores improved from a median preoperative score of 3/10 to a median postoperative score of 10. One dog developed wound drainage over the subcutaneously placed administration port but remained continent after port removal. Three occluders were percutaneously filled with additional saline (median, 0.18 mL; mean, 0.16 mL) to improve continence after surgery.
Conclusions— Application and adjustment of an SHUS provided sustained improvements in continence score in all dogs.
Clinical Relevance— In this pilot study, 3 of 4 dogs with hydraulic urethral sphincter implantation had successful percutaneous adjustment and maintained improved continence scores for 2 years after surgery. Continence was maintained in the 4th dog even after administration port removal. Based on this pilot study, the SHUS warrants further clinical evaluation for treatment of dogs with USMI unresponsive to medical management.  相似文献   

20.
Background: In dogs with congenital portosystemic shunts (CPSS), the ability of the hypoplastic liver to grow is considered important for recovery after surgical shunt attenuation.
Objectives: This study investigated hepatic growth after extrahepatic shunt attenuation in dogs using magnetic resonance imaging (MRI) and computed tomography (CT).
Animals: Ten client-owned dogs with single extrahepatic CPSS.
Methods: Abdominal MRI, CT, or both were performed before and 8 days, 1, and 2 months after shunt attenuation. Liver volumes were calculated from the areas of the MRI or CT images.
Results: Before surgery, median liver volume was 18.2 cm3/kg body weight. Liver volume increased significantly after surgery. Growth was highest between days 0 and 8 and decreased afterward. Median liver volume was 28.8 cm3/kg at 2 months after attenuation. No significant differences in growth were found between dogs with complete or partial shunt closure or between dogs with complete or incomplete metabolic recovery. Volumes measured from consecutively performed MRI and CT images correlated well ( r = 0.980), but volumes from MRI images were significantly larger than volumes from CT images (6.8%; P = .008).
Conclusion and Clinical Importance: After shunt attenuation, rapid normalization of liver size was observed. Hepatic growth was not decreased in dogs after partial closure of CPSS or in dogs with subclinical, persistent shunting 2 months after surgery. CT is the preferred imaging method for volumetric estimation because of speed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号