Objectives: To compare the monotonic biomechanical properties and fatigue life of a 5.5‐mm‐broad locking compression plate (5.5 LCP) fixation with a 4.5‐mm‐broad locking compression plate (4.5 LCP) fixation to repair osteotomized equine 3rd metacarpal (MC3) bones. Study Design: In vitro biomechanical testing of paired cadaveric equine MC3 with a middiaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. Animal Population: Fifteen pairs of adult equine cadaveric MC3 bones. Methods: Fifteen pairs of equine MC3 were divided into 3 test groups (5 pairs each) for (1) 4‐point bending single cycle to failure testing, (2) 4‐point bending cyclic fatigue testing, and (3) torsional single cycle to failure testing. An 8‐hole, 5.5 LCP was applied to the dorsal surface of 1 randomly selected bone from each pair and an 8‐hole, 4.5 LCP was applied dorsally to the contralateral bone from each pair using a combination of cortical and locking screws. All plates and screws were applied using standard ASIF techniques. All MC3 bones had middiaphyseal osteotomies. Mean test variable values for each method were compared using a paired t‐test within each group with significance set at P<.05. Results: Mean yield load, yield bending moment, composite rigidity, failure load, and failure bending moment, under 4‐point bending, single cycle to failure, of the 5.5 LCP fixation were significantly greater than those of the 4.5 LCP fixation. Mean cycles to failure in 4‐point bending of the 5.5 LCP fixation (170,535±19,166) was significantly greater than that of the 4.5 LCP fixation (129,629±14,054). Mean yield load, mean composite rigidity, and mean failure load under torsional testing, single cycle to failure was significantly greater for the broad 5.5 LCP fixation compared with the 4.5 LCP fixation. In single cycle to failure under torsion, the mean±SD values for the 5.5 LCP and the 4.5 LCP fixation techniques, respectively, were: yield load, 151.4±19.6 and 97.6±12.1 N m; composite rigidity, 790.3±58.1 and 412.3±28.1 N m/rad; and failure load: 162.1±20.2 and 117.9±14.6 N m. Conclusion: The 5.5 LCP was superior to the 4.5 LCP in resisting static overload forces (palmarodorsal 4‐point bending and torsional) and in resisting cyclic fatigue under palmarodorsal 4‐point bending. Clinical Relevance: These in vitro study results may provide information to aid in selection of an LCP for repair of equine long bone fractures.  相似文献   

2.
OBJECTIVE: To compare the mechanical properties of two stabilization methods for ostectomized equine third metacarpi (MC3): (1) an interlocking nail system and (2) two dynamic compression plates. Animal or Sample Population-Ten pairs of adult equine forelimbs intact from the midradius distally. METHODS: Ten pairs of equine MC3 were divided into two test groups (five pairs each): caudocranial four-point bending and torsion. Interlocking nails (6 hole, 13-mm diameter, 230-mm length) were placed in one randomly selected bone from each pair. Two dynamic compression plates one dorsally (12 hole, 4.5-mm broad) and one laterally (10 hole, 4.5-mm broad) were attached to the contralateral bone from each pair. All bones had 1 cm mid-diaphyseal ostectomies. Five construct pairs were tested in caudocranial four-point bending to determine stiffness and failure properties. The remaining five construct pairs were tested in torsion to determine torsional stiffness and yield load. Mean values for each fixation method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: Mean (+/-SEM) values for the MC3-interlocking nail composite and the MC3-double plate composite, respectively, in four-point bending were: composite rigidity, 3,454+/-407.6 Nm/rad and 3,831+/-436.5 Nm/rad; yield bending moment, 276.4+/-40.17 Nm and 433.75+/-83.99 Nm; failure bending moment, 526.3+/-105.9 Nm and 636.2+/-27.77 Nm. There was no significant difference in the biomechanical values for bending between the two fixation methods. In torsion, mean (+/-SEM) values for the MC3-interlocking nail composite and the MC3-double plate composite were: composite rigidity, 124.1+/-16.61 Nm/rad and 262.4+/-30.51 Nm/rad; gap stiffness, 222.3+/-47.32 Nm/rad and 1,557+/-320.9 Nm/rad; yield load, 94.77+/-7.822 Nm and 130.66+/-20.27 Nm, respectively. Composite rigidity, gap stiffness, and yield load for double plate fixation were significantly higher compared with interlocking nail fixation in torsion. CONCLUSIONS: No significant differences in biomechanical properties were identified between an interlocking nail and double plating techniques for stabilization of ostectomized equine MC3 in caudocranial four-point bending. Double plating fixation was superior to interlocking nail fixation in torsion.  相似文献   

3.
4.
5.
6.
The biomechanical characteristics of a 4-ring circular multiplanar fixator applied to equine third metacarpal bones with a 5 mm mid-diaphyseal osteotomy gap were studied. Smooth Steinmann pins, either 1/8 inch, 3/16 inch, or 1/4 inch, were driven through pilot holes in the bone in a crossed configuration and full pin fashion and fastened to the fixator rings using cannulated fixation bolts. The third metacarpal bone fixator constructs were tested in three different modes (cranial-caudal four-point bending, axial compression, and torsion). Loads of 2,000 N were applied in bending and axial compression tests and a load of 50 N ± m was applied during testing in torsion. Fixator stiffness was determined by the slope of the load displacement curves. Three constructs for each pin size were tested in each mode. Comparisons between axial stiffness, bending stiffness, and torsional stiffness for each of the three different pin sizes were made using one-way analysis of variance. There was no visually apparent deformation or permanent damage to the fixator frame, and no third metacarpal bone failure in any of the tests. Plastic deformation occurred in the 1/8 inch pins during bending, compression, and torsion testing. The 3/16 inch and 1/4 inch pins elastically deformed in all testing modes. Mean (±SE) axial compressive stiffness for the 1/8 inch, 3/16 inch, and 1/4 inch pin fixator constructs was: 182 ± 16 N/mm, 397 ± 21 N/mm, and 566 ± 8.7 N/mm; bending stiffness was 106 ± 3.3 N/mm, 410 ± 21 N/mm, and 548 ± 12 N/mm; and torsional stiffness was 6.15 ± 0.82 N.m/degree, 7.14 ± 0.0 N±m/degree, and 11.9 ± 1.0 N.m/degree respectively. For statically applied loads our results would indicate that a 4-ring fixator using two 1/4 inch pins per ring may not be stiff enough for repair of an unstable third metacarpal bone fracture in a 450 kg horse.  相似文献   

7.
8.
9.
Objective— To compare the accuracy of reduction and the biomechanical characteristics of canine acetabular osteotomies stabilized with locking versus standard screws in a locking plate. Study Design— Ex vivo biomechanical study. Sample Population— Cadaveric canine hemipelves and corresponding femurs (n=10 paired). Methods— Transverse acetabular osteotomies stabilized with 5‐hole 2.4 mm uniLOCK® reconstruction plates using either 2.4 mm locking monocortical or standard bicortical screw fixation (Synthes® Maxillofacial). Fracture reduction was assessed directly (craniocaudal acetabular width measurements and gross observation) and indirectly (impression casts). All constructs were fatigue‐tested, followed by acute destructive testing. All outcome measures (mean±SD) were evaluated for significance (P<.05) using paired t‐tests. Results— Craniocaudal acetabular diameters before and after fixation were not significantly different (21.9±1.2 and 21.5±1.2 mm; P=.45). No significant differences were observed in acetabular width differences between pre‐ and postoperative fixation between groups (locking ?0.4±0.4 mm; standard ?0.4±0.3 mm; P=.76). Grossly, there was no significant difference in the repairs and impression casts did not reveal a significant (P=.75) difference in congruency between the groups. No significant differences were found in fracture gap between groups either dorsally (locking 0.38±0.23 mm versus standard 0.22±0.05 mm; P=.30) or ventrally (locking 0.80±0.79 mm versus standard 0.35±0.13 mm; P=.23), and maximum change in amplitude dorsally (locking 0.96±2.15 mm versus standard 0.92±0.89 mm; P=.96) or ventrally (locking 2.02±2.93 mm versus standard 0.15±0.81 mm; P=.25). There were no significant differences in stiffness (locking 241±46 N/mm versus standard 283±209 N/mm; P=.64) or load to failure (locking 1077±950 N versus standard 811±248 N; P=.49). Conclusion— No significant differences were found between pelves stabilized with locking monocortical screw fixation or standard bicortical screw fixation with respect to joint congruity, displacement of fracture gap after cyclic loading, construct stiffness, or ultimate load to failure. Clinical Relevance— There is no apparent advantage of locking plate fixation over standard plate fixation of 2‐piece ex vivo acetabular fractures using the 2.4 mm uniLOCK® reconstruction plate.  相似文献   

10.
Objective — To determine the monotonic mechanical properties of osteotomized adult equine tibiae stabilized with two dynamic compression plates (DCP) and to compare the mechanical properties with those of intact tibiae and in vivo loads.
Study Design — The compressive, bending, and torsional mechanical properties of plated and intact tibiae were assessed in vitro.
Animals or Sample Population — Twelve pairs of adult equine tibiae.
Methods — Tibiae were loaded in axial compression, craniocaudal 3-point bending, or torsion in external rotation in a single cycle to failure. Mechanical properties were determined from load-displacement data.
Results — Compared to intact tibiae, the mean yield load, failure load and stiffness of plated tibiae were significantly lower ( P <.05) (compression and torsion); and the mean yield and failure bending moments, and bending stiffness, of the plated tibiae were lower ( P <.075 for yield), or significantly lower, respectively. The mean compression and bending yield loads for plated tibiae were greater than in vivo loads. The mean torsional yield load for plated tibiae approximated the torsional load determined for the adult horse at a walk.
Conclusions — Simple, anatomically reduced, DCP plated tibiae should have adequate strength to withstand immediate, postoperative in vivo compressive loads and bending moments placed on the tibia in vivo during immediate postoperative activities, however, may not have adequate torsional strength during immediate postoperative weight-bearing at a walk.
Clinical Relevance — Additional supportive methods, to decrease torsional loads, may be beneficial in maintaining stability of plate repaired tibiae during recovery from anesthesia and postoperative healing.  相似文献   

11.
OBJECTIVE: To compare drilling, tapping, and screw-insertion torque, force, and time for the 4.5-mm AO and 6.5-mm Acutrak Plus (AP) bone screws, and to compare the mechanical shear strength and stiffness of a simulated complete lateral condylar fracture of the equine third metacarpal bone (MC3) stabilized with either an AO or AP screw. STUDY DESIGN: In vitro biomechanical assessment of screw-insertion variables, and shear failure tests of a bone-screw-stabilized simulated lateral condylar fracture. SAMPLE POPULATION: Eight pairs of cadaveric equine MC3s METHODS: Metacarpi were placed in a fixture and centered on a biaxial load cell in a materials-testing system to measure torque, compressive force, and time for drilling, tapping, and screw insertion. Standardized simulated lateral condylar fractures were stabilized by either an AO or AP screw and tested in shear until failure. A paired t test was used to assess differences between screws, with significance set at P < .05. RESULTS: Insertion and mechanical shear testing variables were comparable for AO and AP insertion equipment and screws. CONCLUSION: The 6.5-mm tapered AP screw can be inserted in equine third metacarpal condyles and is mechanically comparable with the 4.5-mm AO screw for fixation of a simulated lateral condylar fracture. CLINICAL RELEVANCE: Considering the comparable mechanical behavior, the potential for less-persistent soft-tissue irritation with the headless design, and the ability to achieve interfragmentary compression by inserting the screw in one hole drilled perpendicular to the fracture plane, the 6.5-mm tapered AP screw may be an attractive alternative for repair of incomplete lateral condylar fractures in horses.  相似文献   

12.
Objectives— To compare (1) pullout properties between 3.5 mm cortical and locking screws, and (2) mechanical properties and gap displacements between the 3.5 mm broad limited‐contact dynamic compression plate (LC‐DCP), broad dynamic compression plate (DCP), and narrow locking compression plate (LCP), during axial loading of plate‐stabilized diaphyseal fragments with an interfragmentary gap. Study Design— In vitro mechanical testing of implanted polyurethane foam (PUF) hollow cylinders that simulated compact or osteopenic diaphyseal bone. Sample Population— (1) Five cortical and locking screws and (2) 4 PUF‐plate constructs for each plate type; using high‐ and low‐density (0.8 and 0.32 g/cm3) cylinders. Methods— (1) Screws were completely extracted at 5 mm/min. (2) Plated constructs were axially compressed at 300 N/s for 10 cycles from 5 to 355 N to determine gap displacement during physiologic loading, followed by single cycle increasing load to failure. Results— Pullout properties were not different between screw types. All plate constructs had yield loads over 3 times trotting loads. Gap closure occurred with LC‐DCP and DCP constructs, but not LCP constructs. LCP construct properties were most similar to LC‐DCP and DCP construct properties in the low‐density model. Conclusion— All plate systems sustained physiologic limb loads. Only LCP constructs maintained some gap integrity, although LC‐DCP and DCP screws were placed in neutral position. Clinical Relevance— The LCP system is more likely than LC‐DCP and DCP systems, with neutrally positioned screws, to maintain a planned interfragmentary gap, although gap strains range from 0% to 15% across the 2 mm gap during a trot load.  相似文献   

13.
14.
Objective— To compare stiffness and strength of a dynamic condylar screw plate combined with dorsal broad dynamic compression plate (DCS–bDCP) fixation with double broad dynamic compression plate (dbDCP) fixation used to repair oblique distal fractures of adult equine radii. Study Design— Experimental. Sample Population— Adult equine radii (n=10 pair). Methods— An unconstrained three‐dimensional loading–measurement system was used to determine stiffness of a 50 mm long intact, and then DCS–bDCP or dbDCP‐plated osteotomized/ostectomized segment of radii when subjected to a nondestructive sequence of compression, torsion, and lateral‐to‐medial (LM), medial‐to‐lateral (ML), cranial‐to‐caudal (CrCa), and caudal‐to‐cranial (CaCr) bending. Uniform load over the entire length of construct identified its weakest characteristics during torsion and LM and CrCa bending to failure. Results— No difference was observed between osteotomized/ostectomized DCS–bDCP and dbDCP construct stiffness for all 6 loading modes, and strength for all 3 failure loads. Ostectomized DCS–bDCP and dbDCP construct stiffness was significantly lower than osteotomized radii, the latter approaching intact for axial, LM, and CrCa bending. Most frequent failure was bone fracture through exit site of a screw located adjacent to osteotomy/ostectomy. Conclusions— DCS–DCP and dbDCP constructs had comparable strength and stiffness when repairing osteotomies/ostectomies in equine adult radius bone. Fracture reduction increased stiffness that approached intact bone for loads that placed the unplated side in compression. Clinical Relevance— DCS–bDCP and dbDCP constructs are comparable in stiffness and strength when applied to oblique distal diaphyseal osteotomies/ostectomies in equine radius bone. However, the DCS's localized effect on distal epiphyseal structure because of additional bone removal remains to be investigated under in vivo articular loading conditions.  相似文献   

15.
OBJECTIVE: This study compared the mechanical properties of the normal intact suspensory apparatus and two methods of fixation for repair of transverse, midbody fractures of the proximal sesamoid bones of adult horses: transfixation wiring (TW) and screws placed in lag fashion (LS). STUDY DESIGN: An in vitro, paired study using equine cadaver limbs mounted in a loading apparatus was used to test the mechanical properties of TW and LS. ANIMAL OR SAMPLE POPULATION: Seventeen paired (13 repaired, 4 normal) equine cadaver limbs consisting of the suspensory apparatus third metacarpal bone, and first and second phalanges. METHOD: The two methods of repair and normal intact specimens were evaluated in single cycle-to-failure loading. Yield failure was defined to occur at the first notable discontinuity (>50 N) in the load-displacement curve, the first visible failure as evident on the videotape, or a change in the slope of the moment-fetlock angle curve. Ultimate failure was defined to occur at the highest load resisted by the specimen. Corresponding resultant force and force per kg of body weight on the suspensory apparatus, fetlock joint moment, and angle of fetlock dorsiflexion were calculated by use of specimen dimensions and applied load. These were compared along with specimen stiffness, and ram displacement. RESULTS: Load on the suspensory apparatus, load on the suspensory apparatus per kg of body weight, moment, applied load, and angle of fetlock dorsiflexion at yield failure were significantly greater for the TW-repaired than for the LS-repaired specimens. A 3 to 5 mm gap was observed before yield failure in most TW-repaired osteotomies. CONCLUSIONS: Transfixation wiring provided greater strength to yield failure than screws placed in lag fashion in single cycle load-to-failure mechanical testing of repaired transverse osteotomized specimens of the medial proximal forelimb sesamoid bone.  相似文献   

16.
17.
Objective—To determine and compare the in vitro pullout strength of 5.5-mm cortical versus 6.5-mm cancellous bone screws inserted in the diaphysis and metaphysis of adult equine third metacarpal (MCIII) bones, in threaded 4.5-mm cortical bone screw insertion holes that were then overdrilled with a 4.5-mm drill bit to provide information relevant to the selection of a replacement screw if a 4.5-mm cortical screw is stripped. Study Design—In vitro pullout tests of 5.5-mm cortical and 6.5-mm cancellous screws in equine MCIII bones. Sample Population—Two independent cadaver studies each consisting of 14 adult equine MCIII bones. Methods—Two 4.5-mm cortical screws were placed either in the middiaphysis (study 1) or distal metaphysis (study 2) of MCIII bones. The holes were then overdrilled with a 4.5-mm drill bit and had either a 5.5-mm cortical or a 6.5-mm cancellous screw inserted; screw pullout tests were performed at a rate of 0.04 mm/second until screw or bone failure occurred. Results—In diaphyseal bone, the screws failed in all tests. Tensile breaking strength for 5.5-mm cortical screws (997.5 ± 49.3 kg) and 6.5-mm cancellous screws (931.6 ± 19.5 kg) was not significantly different. In metaphyseal bone, the bone failed in all tests. The holding power for 6.5-mm cancellous screws (39.1 ± 4.9 kg/mm) was significantly greater than 5.5-mm cortical screws (23.5 ± 3.5 kg/mm) in the metaphysis. There was no difference in the tensile breaking strength of screws in the diaphysis between proximal and distal screw holes; however, the holding power was significantly greater in the distal, compared with the proximal, metaphyseal holes. Conclusions—Although tensile breaking strength was not different between 5.5-mm cortical and 6.5-mm cancellous screws in middiaphyseal cortical bone, holding power of 6.5-mm cancellous screws was greater than 5.5-mm cortical screws in metaphyseal bone of adult horses. Clinical Relevance—If a 4.5-mm cortical bone screw strips in MCIII diaphyseal bone of adult horses, either a 5.5-mm cortical or 6.5-mm cancellous screw, however, would have equivalent pullout strengths. A 6.5-mm cancellous screw, however, would provide greater holding power than a 5.5-mm cortical screw in metaphyseal bone.  相似文献   

18.
19.
Objective— To compare the biomechanical characteristics, failure mode, and effects of side (left or right limb) and end (forelimb or hindlimb) of different screws in 2-screw, parallel-screw proximal interphalangeal joint arthrodesis constructs in horses.
Study Design— In vitro experimental study.
Sample Population— Twenty limbs from 6 cadavers (4 complete limb sets, 2 partial sets—total of 4 forelimb and 6 hindlimb pairs).
Methods— Two parallel 5.5 mm cortical (AO) screws were inserted in lag fashion in 1 randomly allocated limb of a pair, and 2 parallel headless, tapered, variable-pitched, titanium compression screws (Acutrak-Plus®) were inserted in the contralateral limb. Constructs were tested in 3-point bending in a dorsopalmar (plantar) direction using a materials-testing machine at a loading rate of 5.83 mm/s. Maximal bending moment at failure and composite stiffness were calculated from data generated on load–displacement curves. Data were analyzed using a Friedman 2-way analysis of variance and Wilcoxon's signed-rank tests.
Results— No significant difference was detected for bending moment or stiffness values in proximal interphalangeal joint arthrodesis constructs using 2 parallel Acutrak-Plus® or AO screws for fixation. Mean stiffness values were significantly different between forelimb and hindlimb constructs.
Conclusions— Performance of 2 parallel Acutrak-Plus® screws was biomechanically comparable with 2 parallel AO 5.5 mm cortical screws in in vitro pastern arthrodesis constructs.
Clinical Relevance— Acutrak-Plus® screws may provide an alternative means of fixation for proximal interphalangeal joint arthrodesis.  相似文献   