首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An axial symmetric invariable temperature phase change interface model of capillary porous wick based on alkali metal thermal-to-electric converter (AMTEC) is established to simulate flow and heat transfer characteristics in capillary porous wick and liquid channel by solving the mass and heat transport controlling equations. The effects of the working fluid flow rate, inlet temperature, porous wick thickness, porosity and effective pore diameter on the distributions of pressure, velocity and temperature are analyzed. In addition, the available effective pore size of the porous wick and the measures to improve the performance of the porous wick are given by analyzing the relationship between the maximum available capillary pressure and the loop pressure drop. The results show that the model presented in gives a good agreement with the three dimensional two-phase evaporation model. The flow and heat transfer characteristics of the capillary porous wick with the alkali metal liquid as working fluid are different from that with the traditional working fluid in some ways.  相似文献   

2.
A numerical study is carried out for the combined heat transfer of turbulent natural convection and surface radiation in an two-dimensional open square cavity with only one heated wall. The results show that the radiation significantly affects the velocity and temperature fields,and it can reduce the turbulent natural convection heat transfer as well as enhance it. For different Rayleigh number and temperature difference ratio,the overall heat transfer rates and the portion of radiation present different variation patterns.  相似文献   

3.
为解决地铁站冷却塔设置难题,提出了一种采用低速电机驱动旋转布水装置的间接蒸发冷却器,在两种布置方式下,对其换热性能进行了单因素实验,并运用正交实验法对较优布置方式下影响换热器换热的因素进行了分析。结果表明:两种布置方式下,喷嘴与蒸发冷却器的间距、两组换热管束间距均存在最佳值,喷嘴双侧旋转布水优于单侧旋转布水;换热器平行气流布置且喷嘴双侧旋转布水为较优布置方式,此时,换热器换热量随喷水量、转速、空气速度、冷却水进口温度的增加以及喷水温度、空气温度的降低而增大,其中,冷却水进口温度对换热器换热影响最为显著,其他因素对其换热的影响从主到次顺序为:喷水量、空气温度、空气速度、喷水温度、转速、冷却水流量。  相似文献   

4.
For the open-loop surface water source heat pump systems, energy consumption of water supply is the key factor for energy saving of system. On the basis of energy consumption model of heat pump unit and energy consumption model of water supply etc., open-loop surface water source heat pump system energy efficiency ratio coupling model is established. Based on energy efficiency ratio,the coupling limit value of surface water source heat pump system in different temperature of water supply and different energy consumption of water supply is obtained.Through the actual case, energy saving rate of the system is calculated in different temperatures of water supply and different system modes. And the determination method of the limit energy consumption of water supply of open-loop surface water source heatpump systems is established.  相似文献   

5.
Energy consumption of water intake is one of the key factors for energy saving in the application of the open loop surface water heat pump system. An energy efficiency ratio coupling model for open loop surface water source heat pump systems was established on the basis of the energy consumption model for the water intake and the heat pump units. According to energy saving rate and regulation of energy consumption of water intake, dynamic temperature limits of water intake in different water supply temperature of cooling tower and different pump head were proposed so as to find a calculation method of temperature limits of water intake of open loop surface water heat pumps. Moreover, the energy saving rate of surface water source heat pump systems compared with traditional air conditioning systems under various condition was also calculated.  相似文献   

6.
According to the work of Motakef and EI-Masri, the wall was divided into dry-wet-dry zones. Based on the heat and moisture transfer through porous media, considering the vapour condensation as a vapour sink, water source and heat source, coupled heat and moisture equations for wet zone were established. Closed-form analytical expressions for the condensation rate, moisture content and the time when critical moisture content value reached are obtained. It is indicated that the condensation rate exhibits a strong dependence on the temperature difference of the two sides of wet zone, and the maximum condensation rate value is reached at the boundary of wet zone close to lower temperature.  相似文献   

7.
With the influence of the different gas Reynolds number and liquid Reynolds number on falling film heat and mass transfer of subway station plate evaporative cooler, the experiment was carried out by non contact infrared thermal imaging technology under gas liquid cross flow condition. The results indicated that during the increasing of liquid Reynolds number the thickness of liquid film increased and the temperature difference between liquid film inlet and outlet decreased in determined heating water temperature which weakened the heat transfer of liquid film. However, the increase of liquid Reynolds number strengthened the liquid film turbulence that enhanced heat transfer. Under the synergistic effect of these two factors, there was an optimal liquid Reynolds number which minimize thermal resistance and maximize heat and mass transfer coefficient of liquid film.  相似文献   

8.
This paper conducts in-tube heat transfer experiments in a three dimensional fin tube with 102 mm outer diameter.Compared with the smooth tube,the heat transfer enhancement ratio is between 1.65 and 1.7,and the pressure drop ratio is between 1.65 and 1.7.Based on the analysis of the heat transfer and tube surface temperature,a new type heat exchanger is put forward.Moreover,the design and calculation method is explored.The engineering example indicate that not only the tube surface temperature is higher than the smooth tube,but also the quantity of heat is increased by about 20% than the smooth tube.Compared with other types,the new type heat exchanger has a overall better performance.  相似文献   

9.
In order to improve utilization of cold and heat source from river, turbulence theory and entropy generation theory were adopted to analyze the effect of fouling on convective heat transfer performance in small diameter tube of constant wall temperature.It is found that the entropy generation caused by conduction of fouling plays a more important role in total entropy generation of heat transfer process through a duct than that in cveast rate of caused by temperature difference.The entropy generation caused by viscous flow is more than the entropy generation caused by temperature difference in flow with bigger Reynolds and small radius.The increase rate of entropy generation monotonically increase with Reynolds and the generation process of fouling resistance.Thereafter, the effect of fouling resistance on the heat transfer performance of water source heat pump heat exchanger should be paid more attention, when river water are used as the cold and heat source of heat pump.  相似文献   

10.
重庆村镇空气源热泵供暖系统夜间性能实测分析   总被引:1,自引:0,他引:1  
针对重庆山地村镇迫切的供暖需求,选取该地区典型村镇搭建了空气源热泵供暖系统实验平台,分析了空气源热泵系统性能影响因素,并从供回水温度、系统耗电量、供热量、性能系数COP等角度对运行过程中的阶段特性(启动、稳定运行及全阶段)进行阐述,发现系统在3个阶段特点差异很大:启动阶段初始温度对COP影响较为明显,除霜时系统性能下降25%;稳定阶段特性与初始温度无关,室外条件较好时,降低设定温度,COP提高明显;总体来看,启动阶段COP最高,全阶段次之,稳定阶段COP最低。  相似文献   

11.
In the established model, the cooling differences are considered between the surface of inner radius and that of outer radius, and in the transverse direction of thin slab. And the conception for the effective coefficient of spraying water in continuous casting is firstly put forward. According to different casting speeds and different cooling zones, different time step lengths are adopted. In this model the heat transfer differences are thought over among vertical and curved zones, wide and narrow surfaces an well as angular zone of mould. The method of the corrected equivalent specific heat is used to deal with latent heat. The influence of forced convection is considered on heat transfer. Therefore, the model has higher accuracy and is consistent with the practice.  相似文献   

12.
A mathematcal model of heat transfer between the billet and the roller for the seeondary cooling zone in billet continuous casting is established. By means of the simulated test,a regres sion relation between the heat flow from the billet into the roller and the surface temperature and cast ing speed and spray water density obtained. The calculated theoretical values for change of surface temperature are in agreement with the measured data, these studies may contribut to the quantitative analysis and the calculation of the heat transfer of the secondary cooling zone.  相似文献   

13.
This paper presents the experimental results of convective heat transfer performance in 5 copper tubes with three dimensional internally extended surface, with flow of various test fluid in the Reynolds number range of 8,000 to 80,000. Water and mixture of ethylene glycol with water (the ethylene glycol weight content equals 55%) are chosen as test fluid. The effect of the physical properties for test fluid on heat transfer performance in the tubes with three dimensional internally extended surface is discussed. The heat transfer correlation is obtained by the experimental data.  相似文献   

14.
In order to study the cooling characteristics of the nozzle, a test platform is designed and developed for spray cooling feature measurement based on unsteady state heat conduction. By heating and keeping Q215 metal samples up to some surface temperature, a series of temperature data are collected by S7-200 modules during spray force cooling. Through Visual C++6.0 and Matlab interface programming, a series of regression equation with thermodynamic property versus temperature, such as density, specific heat capacity, and thermal conductivity etc., and with temperature versus sample time are obtained. The surface heat transfer coefficient and spray cooling feature of nozzle can be indirectly measured by the regression equations. The relation between surface heat transfer coefficient versus temperature, spray pressure and water intensity are investigated by means of the testing equipment. The experiment result shows the method is feasible and can be used in spray cooling feature measurement for all kinds of nozzle.  相似文献   

15.
On the basis of analyzing the complicate heat and humid exchange between the outdoor air and the water layer of the roof,the authors obtained a heat transfer model and it's transmit matrix. The temperature and heat flux responses of the internal roof surface is greatly lowered than that of non-water layer roof. It can be concluded that the maintenance of a water layer on the roof is a good way to resist the fluctuation of outdoor temperature and significantly reduce the cooling load of a building.  相似文献   

16.
通过夏季工况的地源热泵运行试验,对运行过程中水平埋管的换热性能参数、试验场地周围气象因素和换热过程中土体的温湿度变化等因素进行实时监测,探讨了地源热泵运行过程中水平埋管换热器热交换性能及其周围土壤的温、湿度场变化规律。研究结果表明,地源热泵间隙运行有利于土壤温度场的恢复,随着停机时间的增加,水平埋管与周围土壤的热交换能力明显提高;气候变化对水平埋管周围土壤的温度场分布具有显著影响,随着埋深的递减,土壤温度受气候变化的影响越明显;水平埋管周围土壤温度的变化幅度随着与埋管距离的增加呈递减趋势,其影响半径为1.0m左右;热交换对水平埋管周围土壤湿度场的影响不明显,但大气降雨引起的地表水入渗对土壤湿度场的分布具有显著影响。  相似文献   

17.
The vertical U-tube ground-coupled heat pump system provides cold and heat for the controlling of indoor environment. Under the air-conditioning condition, the vertical U-tube ground-coupled heat pump system with heat recovery can provide domestic hot water. The influence of supplying domestic hot water on the heat transfer performance of ground heat exchangers is different under different operating modes in summer and winter. Through a project design of ground-source heat pump system, the influence of supplying domestic hot water under heat storage mode on the heat transfer performance of ground heat exchangers in summer and winter is respectively analyzed. The dynamic performance of heat exchangers under different working conditions is analyzed, and through numerical calculation, the heat transfer performance parameters of ground heat exchangers under different operating modes are obtained. From the calculation results, the adjusting methods based on the load characteristics of this project represent.  相似文献   

18.
覆盖生态木屑对城市公园土壤温湿度的影响   总被引:3,自引:1,他引:2  
为实现绿化垃圾的循环利用,量化评估覆盖生态木屑对土壤表层温湿度的影响。利用土壤温湿度计定期测定土壤表层温湿度持续1年。结果表明,冬季铺设生态木屑具有良好的保温保湿效果,不铺设木屑土壤含水率迅速下降到10%以下,铺设生态木屑15~20 cm后整个冬季土壤含水率都保持在16%以上,后者土壤温度比前者土壤温度高2℃以上。夏季铺设生态木屑5~10 cm的样树,含水率低于不铺生态木屑的对照组和其他试验组,但对温度的影响并不明显。冬季覆盖生态木屑对土壤表层具有明显的保温保湿效果,且覆盖生态木屑越厚保温保湿效果越显著;而夏季覆盖生态木屑的最佳厚度为5~10 cm,覆盖此厚度的生态木屑既可以起到海绵体吸收多余水分的作用,又不会因为覆盖生态木屑后树冠与根系间的温差增大导致的植物生理性缺水。因此,建议城市公园铺设生态木屑的厚度为5~10 cm。  相似文献   

19.
低温送风空调系统引进新型冰蓄冷设备,采用正丁烷作为制冷剂,制冷剂与水直接接触,换热更强烈且稳定。为了研究该系统相应㶲损因素条件下的节能薄弱环节,实现系统性能优化,基于该系统及各表冷器㶲分析模型,分析了热湿比、新风比、送风温差等㶲损因素对系统㶲效率和各表冷器㶲损率的影响。结果表明:当热湿比变化时,处理二次混风的表冷器㶲损率随之呈正比变化,其他表冷器㶲损率及系统㶲效率随之呈反比变化;当新风比变化时,处理新风的两级表冷器㶲损率随之呈正比变化,其他表冷器㶲损率及系统㶲效率随之呈反比变化;当送风温差变化时,处理一次回风的表冷器㶲损率随之呈正比变化,其他表冷器㶲损率及系统㶲效率随之呈反比变化。  相似文献   

20.
A theoretical model is developed for the dropwise condensation heat transfer on the horizontal circular surface with radial gradient surface energy based on the heat transfer model of individual condensate drop and the size distribution model of condensate drop on homogeneous condensation surface.The effect of variation of contact angle on the gradient surface on condensation heat transfer and condensate drop size distribution is taken account of in this model.The theoretical calculation method was obtained to predict the dropwise condensation heat transfer coefficient on the horizontal circular surface with radial gradient surface energy under various wall subcooled temperature,contact angle profile on wall surface,and working fluid.The effects of surface energy gradient,wall subcooled temperature,and thermophysical properties of condensate on the condensation heat transfer are discussed respectively.The calculation results show that the condensation heat transfer coefficient increases slightly with the increase of wall subcooled temperature.As latent heat and surface tension increasing,the condensation heat transfer coefficient increases.A larger surface energy gradient induces a larger condensation heat transfer coefficient.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏