首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Osseous neoplasia was identified in the proximal portion of the tibia and distal portion of the femur in an 11.75-year-old spayed female German Shepherd Dog. A tibial plateau leveling osteotomy, followed by application of a metal plate, had been performed on the affected limb 5.5 years earlier. Areas of osteolysis and periosteal proliferation were seen radiographically, with an intense area of osteolysis directly beneath the metal plate. Histologically, the tumor was identified as a poorly differentiated sarcoma. Extracellular and intracellular debris was seen histologically, and energy-dispersive x-ray analysis confirmed that this debris was metallic. On visual examination, areas of the underside of the metal plate that had been in contact with bone had a dull, roughened appearance, and scanning electron microscopy of these areas revealed multiple corrosion pits. The plate was strongly magnetic, suggesting that it contained ferrite, and metallographic examination of the plate revealed substantial differences in the chemical makeup of various parts of the plate. Microstructure analysis revealed that the plate consisted of an austenite matrix with a large fraction of ferrite. The plate was determined to be a cast 316L stainless steel implant, but it did not meet American Society for Testing Materials standards for implant-grade materials. The possibility that implant corrosion might have played a role in tumor development is of concern; however, a definitive association was not established.  相似文献   

2.
OBJECTIVE: To determine the change in tibial plateau angle (TPA) during healing after tibial plateau leveling osteotomy (TPLO) performed for cranial cruciate ligament insufficiency in dogs and to examine factors that may be associated with the change. STUDY DESIGN: Retrospective study. STUDY POPULATION: One hundred and forty-nine canine stifles after TPLO procedure. METHODS: Records of dogs that had TPLO were reviewed. Patient age, weight, sex, breed, pre- and postoperative TPA, recheck TPA, time to recheck, type of implant used, and radiographic evidence of healing were analyzed. RESULTS: Mean time to recheck evaluation was 46 days (range, 28-65 days). Mean difference between immediate postoperative and recheck TPA measurements was 1.5 degrees (range, -3 to 9 degrees). Recheck TPA was a significantly greater (numerically higher) than immediate postoperative TPA (P<.0001). There was no significant effect of patient weight, type of plate used, or healing status of the osteotomy at the time of recheck. No correlation between pre- or postoperative TPA angles and change in TPA angle was detected. CONCLUSIONS: TPA changes during osteotomy healing after TPLO, but factors influencing this change were not identified. CLINICAL RELEVANCE: TPA may increase during healing after TPLO despite apparently adequate osteotomy fixation. The clinical relevance of this increase is unknown but is likely minimal.  相似文献   

3.
OBJECTIVE: To investigate radiographic changes of the tibial tuberosity after tibial plateau leveling osteotomy (TPLO) surgery and identify clinical findings and risk factors associated with such changes. STUDY DESIGN: Retrospective study. SAMPLE POPULATION: Hundred and eighty-six client-owned dogs (219 stifles) that had TPLO surgery. METHODS: Patient data retrieved included radiographic changes of the tibial tuberosity during re-examination, age, body weight, whether unilateral or single-session bilateral surgery had been performed, location of the anti-rotational pin, approximate tibial tuberosity area, and approximate average tibial tuberosity width. RESULTS: Fracture with resulting caudal displacement of the proximal tibial tuberosity (1.4%; 3 of 219) occurred less frequently than non-displaced tibial tuberosity fractures (7.3%; 16 of 219). Age, weight, average tibial tuberosity width, location of the anti-rotational pin, and single session bilateral surgery were identified as risks factors for non-displaced fracture. Weight divided by the square of the average tibial tuberosity width may be a stronger risk factor than either weight or average tibial tuberosity width alone. CONCLUSIONS: Dogs undergoing single session bilateral TPLO surgery are at greater risk for developing non-displaced tibial tuberosity fractures. The non-displaced tibial tuberosity fracture does not appear to adversely affect outcome or lead to tibial tuberosity avulsion. Significant risk factors for fracture of the proximal tibial tuberosity with caudal displacement were not identified. CLINICAL RELEVANCE: Factors including age, weight, tibial tuberosity thickness, and conditions that may enhance strain on the tibial tuberosity, such as single-session bilateral procedures, may increase risk of fracture.  相似文献   

4.
5.
OBJECTIVE: To evaluate the biomechanical effects of medial meniscal release (MMR) and medial, caudal pole hemimeniscectomy (MCH) on joint stability in the cranial cruciate ligament (CCL)-deficient canine stifle before and after tibial plateau leveling osteotomy (TPLO). STUDY DESIGN: Experimental study. ANIMALS: Thirty-one dogs. METHODS: In experiment 1, 16 pairs of normal hindlimbs randomly assigned to an intact or transected CCL group were studied to determine the magnitude of tibial translation after MMR and MCH under 20% body weight load using radiographic imaging of radio-opaque markers. In experiment 2, 15 pairs of CCL-deficient hindlimbs were randomly assigned to a TPLO or sham TPLO group. The remainder of the experiment was performed as described for experiment 1. The effect of CCL transection, MMR, MCH and TPLO were analyzed using 2-way repeated measures ANOVA; P<.05 was considered significant. RESULTS: We found a greater effect of MMR on tibial translation in transected CCL stifles than in intact stifles (P=.0016). We found no further effect of MCH after MMR (P>.05). We found a greater effect of MMR in sham TPLO than TPLO stifles (P=.0013) but no further effect of MCH after MMR (P>.05). CONCLUSIONS: By resisting tibial translation the medial meniscus might be at greater risk of tearing in CCL-deficient stifles. TPLO may spare the medial meniscus by neutralizing the tibial thrust and eliminating the wedge effect of the medial meniscus. CLINICAL RELEVANCE: MMR may not be indicated in the CCL-deficient stifle stabilized by TPLO.  相似文献   

6.
Objective— To evaluate factors that predispose to tibial tuberosity (TT) fracture after tibial plateau leveling osteotomy (TPLO) in dogs.
Study Design— Retrospective study.
Animals— Dogs (n=182) with cranial cruciate ligament (CCL) rupture undergoing 213 TPLO surgeries.
Methods— Medical records and radiographs of 2 groups of dogs that had TPLO surgery (2000–2001, 2004–2005) were evaluated to determine the effect of operative technique and surgeon experience on TT fracture.
Results— TT fracture was diagnosed in 8 dogs (9 TPLO, 4.2% of surgical procedures). Four fractures occurred after unilateral TPLO in 167 dogs (2.4%), 4 fractures occurred after simultaneous bilateral TPLO in 5 dogs (40%), and 1 fracture occurred after staged bilateral TPLO in 36 dogs (2.8%). Simultaneous bilateral TPLO resulted in a 12.4 times higher odds of TT fracture versus unilateral TPLO ( P =.046). The mean absolute thickness of the TT after TPLO was less in dogs sustaining TT fractures (7.2 ± 2.2 mm) than those that did not (10.8 ± 2.7 mm, P <.0001). The odds of fracture decreased by 37% when the absolute TT width postosteotomy increased by 1 mm ( P <.0001). An increase in tibial plateau angle at follow-up versus immediately postoperative was associated with TT fracture ( P =.025). Surgeon experience was not associated with TT fracture.
Conclusion— A combination of surgical decision-making and surgical technique play a role in the occurrence of TT fracture after TPLO. Simultaneous bilateral TPLO was associated with a high percentage of TT fracture.
Clinical Relevance— Careful planning of osteotomy positioning is advised while performing TPLO surgery.  相似文献   

7.
OBJECTIVE: To describe a surgical technique, and outcome, for treatment of cranial cruciate ligament (CrCL) deficient stifle joints with excessive tibial plateau angle (TPA) by combined tibial plateau leveling osteotomy and cranial closing wedge osteotomy (TPLO/CCWO). STUDY DESIGN: Retrospective clinical study. ANIMALS: Fifteen client-owned dogs (18 stifle joints). METHODS: Medical records of dogs that had TPLO/CCWO were reviewed. Pre- and postoperative TPA, CCWO technique, method of fixation and complications were recorded. In-hospital re-evaluation of limb function and length of time to radiographic healing was reviewed. Long-term outcome was assessed by owner telephone interview. RESULTS: Mean pre- and postoperative TPA was 42 degrees and 8 degrees, respectively. The Slocum biradial saw was used to create the CCWO in 4 stifle joints (mean postoperative TPA, 16 degrees) and a sagittal saw was used in 14 stifle joints (mean postoperative TPA, 5 degrees). Postoperative surgical complications were documented in 77.8% of cases; including patellar tendon thickening (61.1%), and implant loosening or breakage (27.8%), seroma formation (11.1%), and local irritation (11.1%). A second surgical procedure was performed in one-third of cases primarily to retrieve implants. Mean time to documented radiographic healing was 18 weeks. Final in-hospital re-evaluation of limb function (mean, 23 weeks postoperatively) was recorded as no lameness in 73.3% and mild lameness in 26.7%. All interviewed owners were satisfied with outcome and 90.9% reported marked improvement or a return to preinjury status. CONCLUSIONS: Long-term clinical outcome of TPLO/CCWO was very good in dogs with excessive TPA, with high owner satisfaction. Longer healing times and a higher complication rate were observed compared with TPLO alone. CLINICAL RELEVANCE: TPLO/CCWO of the tibia in stifle joints with excessive TPA allows for full correction of the TPA to 5 degrees without eliminating buttress support of the tibial tuberosity.  相似文献   

8.
Objective: To describe a surgical technique, and outcome, for treatment of proximal tibial deformity (varus, valgus, excessive tibial plateau angle [eTPA], tibial torsion and patellar luxation) by combined tibial plateau leveling osteotomy (TPLO) and transverse corrective osteotomy. Study Design: Cases series. Animals: Dogs (n=12; 19 stifle joints). Methods: Medical records of dogs that had combination TPLO and transverse corrective osteotomy, were reviewed. Pre‐ and postoperative tibial angulation, tibial torsion, tibial plateau angle (TPA), corrective osteotomy technique, method of fixation, and complications were recorded. In hospital re‐evaluation of limb function and alignment and length of time to radiographic healing were reviewed. Long‐term outcome was assessed by visual analog scale (VAS) questionnaire and owner telephone interview. Results: Proximal tibial varus or valgus was present in 68.4%; 73.7% had eTPA; and 47.4% had both. Medial patellar luxation (MPL) was present in 57.9%, of which 47.4% had tibial tuberosity displacement. Severe tibial torsion was present in 68.4%. Mean pre‐ and postoperative TPA was 37.5° and 5.7°, respectively. The mean postoperative mechanical medial proximal tibial angle (mMPTA) and mechanical medial distal tibial angle (mMDTA) were 92.2° (range, 88–96°) and 96.1° (range, 94–101°), respectively. Postoperative surgical complications were documented in 21.0%, which included implant loosening or breakage (5.3%), seroma (5.3%), septic arthritis (5.3%), and infection of the proximal tibia (5.3%). All complications were considered major because they required additional surgery. Mean time to document radiographic healing was 10.4 weeks. In‐hospital re‐evaluation of lameness was obtained at the same time; 82.4% were not lame or had a mild lameness, 17.6% had severe lameness (2/3 with infection). The VAS evaluation revealed excellent results and owner satisfaction in all ten dogs in which long‐term follow‐up was obtained. Conclusions: Long‐term clinical outcome of combination TPLO and transverse corrective osteotomy was excellent, and had a high owner satisfaction. Healing times were comparable to standard TPLO with a similar complication rate.  相似文献   

9.
10.
11.
OBJECTIVE: To evaluate the influence of a tibial plateau leveling jig on osteotomy orientation, fragment reduction, and postoperative tibial plateau angle (TPA) during tibial plateau leveling osteotomy (TPLO). STUDY DESIGN: In vitro experimental study. ANIMALS: Large-breed canine cadavers (n=20). METHODS: TPLO was performed on 40 hindlimbs using 4 methods. Group 1: Jig; dogs in dorsal recumbency with the osteotomy parallel to the distal jig pin. Groups 2-4: No jig; dogs in lateral recumbency with the osteotomy in a vertical orientation (group 2: tibia parallel to the table top; group 3: controlled superimposition of the femoral condyles; group 4: internal rotation of the tibia). Postoperative TPA, fragment reduction, and osteotomy orientation relative to the tibial plateau were compared. Positive or negative values denoted deviation from parallel relative to the tibial plateau. RESULTS: Postoperative TPA, fragment reduction, and proximodistal osteotomy orientation were not significantly different between groups. Craniocaudal osteotomy orientation was significantly different (P<.005) from the tibial plateau. Median deviations were -4.0 degrees (group 1), 11.8 degrees (group 2), 11.2 degrees (group 3), and 0.2 degrees (group 4). Group 1 was not significantly different from group 4. CONCLUSIONS: A jig is not essential for osteotomy orientation, tibial plateau rotation, or fragment reduction. Comparable results were achieved performing a vertical osteotomy with the tibia slightly internally rotated (10 degrees -15 degrees) and parallel to the table surface. CLINICAL RELEVANCE: TPLO without use of a jig reduces surgical trauma, is less time consuming, and reduces cost.  相似文献   

12.
This prospective study evaluated anatomic femorotibial changes utilizing the relationship between the intercondylar notch and the intercondylar eminence following tibial plateau leveling osteotomy (TPLO). We hypothesized that TPLO results in anatomic alteration of the femorotibial joint. Pre- and post-operative computed tomography (CT) scans of cranial cruciate deficient stifle joints treated with TPLO were performed on 25 client-owned dogs. Computed tomography scans were performed at 3 different stifle angles: extension, 135° walking angle, and 90° of flexion. Tibial plateau leveling osteotomy did not result in a significant medial or lateral shift of the intercondylar eminence relative to the intercondylar notch. There was a significant cranial shift of the intercondylar eminence with the stifle in extension following TPLO. In addition, TPLO resulted in a significantly narrowed femorotibial joint space. The biomechanical effects of TPLO and medial meniscal release need to be further defined.  相似文献   

13.
14.
15.
16.
OBJECTIVE: To determine the microchemical and surface composition of tibial plateau leveling osteotomy (TPLO) plates before and after explantation. SAMPLE POPULATION: 7 TPLO plates surgically removed from host dogs 6 to 54 months after implantation; 2 raw unpolished-and-unpassivated 316L TPLO plates; and 2 heat-treated, polished-and-passivated, and cleaned 316L TPLO plates. PROCEDURES: Samples were removed by use of standard techniques to ensure the plate surface was not damaged. Sample pieces were dissolved and analyzed by inductively coupled plasma-mass spectrometry (ICP-MS) to determine bulk elemental composition. Other sample pieces were investigated by use of scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and x-ray photoelectron spectroscopy (XPS) for determination of sample morphology, near-surface elemental composition, and surface elemental composition, respectively. To investigate the possibility of corrosion in situ, some samples were chemically corroded and analyzed. RESULTS: ICP-MS confirmed that elemental composition of samples was consistent with 316L stainless steel. The SEM and EDS analyses revealed trace amounts of polishing materials and a nonuniform carbonaceous biofilm on < 1% of the surface area of samples removed from the host dogs. The XPS analysis indicated an increase in the chromium-to-iron ratio on passivated surfaces, with no difference between passivated samples before implantation and after explantation. CONCLUSIONS AND CLINICAL RELEVANCE: Composition of the TPLO plates was consistent with 316L stainless steel. No chemical or topographic changes were detected in TPLO plates that had been implanted in dogs for up to 54 months. A small amount of biofilm was evident on the surface of 2 plates.  相似文献   

17.
18.
19.
The progression of osteoarthritis and clinical function in 29 dogs at least 1 year after tibial plateau leveling osteotomy was evaluated. A previously reported radiographic scoring system was used by 3 investigators to evaluate preoperative and postoperative radiographs for evidence of stifle osteoarthritis. The combined scores were then used to evaluate the progression of osteoarthritis. The difference between the preoperative scores, derived from radiographs taken at the time of surgery, and the postoperative scores based on radiographs taken at least 1 year later was modest but statistically significant. Despite this finding, client satisfaction was very good. Clinical function was assessed by using a previously reported client questionnaire. According to owner assessment at least 1 year after surgery, there was a significant improvement in function after tibial plateau leveling osteotomy when compared with the preoperative status. Improvement in function as measured by the client questionnaire did not significantly predict the radiographic osteoarthritis score.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号