首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Serum bile acid (SBA) reference intervals were established by use of a radioimmunoassay method for fasting dogs to be 0.2 to 4.3 micro mol/L (n = 60) and for 2 hour postprandial samples to be 0.6 to 24.2 micro mol/L (n = 37). The SBA reference intervals estimated using an enzymatic method were 0 to 8.6 micro mol/L for fasting (n = 26) and 0 to 29.8 micro mol/L for 2 hour postprandial samples (n = 36). The correlation between the two methods including samples from healthy dogs and clinical cases is good (n = 128, r = 0.82, p < 0.0001). The radioimmunoassay method is linear to 50 micro mol/L and the enzymatic method is linear to 100 micro mol/L, thus both methods require serum dilutions to be made in many cases of primary liver disease. The enzymatic method is less expensive and more convenient for use in a clinical laboratory but requires a greater sample volume (400 micro I) than the RIA method (50 micro I). Both methods have adequate precision and accuracy to be useful as diagnostic tests of liver function in dogs.  相似文献   

3.
4.
北京地区犬猫弓形虫病流行病学调查   总被引:1,自引:0,他引:1  
为初步调查北京地区犬猫弓形虫感染的流病学特征,用酶联免疫吸附试验(ELISA)方法检测2010年5月至2011年4月采集的家养犬猫、流浪猫血清样本.其中,家养犬血清样本1876份,家养猫血清样本561份,检测发现,家养犬动物弓形虫IgG抗体阳性率24.9%;家养猫弓形虫IgG阳性率21.2%;同时检测流浪猫样本201份,阳性率30.3%.家养犬弓形虫血清抗体阳性率不同季节间差异显著(P<0.05),夏季最高,为30.0%,家养猫弓形虫血清抗体阳性率不同季节间无显著差异(P>0.05).不同性别犬猫弓形虫血清抗体阳性率无显著差异(P>0.05).随着年龄增长,犬猫弓形虫抗体阳性率均有明显增长.对25例弓形虫抗体阳性家养犬病例和37例弓形虫抗体阳性家养猫病例进行了回访调查,结果发现,该62例动物主人的弓形虫检测结果均为阴性.  相似文献   

5.
Urine bile acid (UBA) tests reflecting "average" serum bile acid (SBA) concentrations may have greater practical utility than paired SBA samples in cats. This study evaluated whether urine sulfated bile acids (USBAs), urine nousulfated bile acids (UNSBAs), or a combined approach had a clinical utility equivalent to SBAs. Routine serum biochemistry tests, SBA concentrations, and urine samples were collected from 54 cats with hepatobiliary disease, 17 cats with nonhepatic disorders, and 8 healthy cats. UBAs were measured by a quantitative enzymatic colorimetric method, and results were normalized with urine creatinine (UCr) concentrations. Significantly higher values occurred in cats with liver disease than in cats without liver disease for USBA : UCr, UNSBA:UCr, and (USBA and UNSBA) : UCr, P < .05 each. UBA tests with diagnostic performance (sensitivity [SS], specificity [SP], and positive and negative predictive values [PV+ and PV-]) equivalent to SBAs were the UNSBA : UCr and the combined test (SS: 87, 87 versus 85; SP: 88, 88 versus 88; PV+: 96, 96 versus 96; PV-: 68, 65 versus 68; UNSBA : UCr, [USBA, and UNSBA]: UCr versus SBA, respectively). Clinical applications of the UNSBA : UCr or the combined (USBA and UNSBA) : UCr test should be useful as convenient diagnostic tests for identifying cats with liver disease and high SEA concentrations.  相似文献   

6.
Background: Portosystemic shunt (PSS) is the most common cause of hepatic encephalopathy in dogs and cats. Fasting ammonia and serum bile acids (SBA) are used to diagnose PSS, but their true sensitivity and specificity have not been fully evaluated, especially in cats. Objectives: The purpose of this study was to determine the diagnostic accuracy of fasting ammonia and SBA concentrations in the diagnosis of PSS in dogs and cats and to compare diagnostic accuracy between species. Methods: A retrospective analysis of data from 373 dogs and 85 cats presented to the clinic from 1996 to 2006 was carried out. Based on clinical, laboratory, and imaging findings, animals were grouped as having PSS, parenchymal hepatic disease, or extrahepatic disease. The sensitivity and specificity of ammonia and SBA concentrations for the diagnosis of PSS were calculated and receiver‐operating characteristic analysis was used to optimize cut‐offs. Results: Using the upper limit of laboratory reference intervals (ammonia, 59 μmol/L; SBA, 20 μmol/L), the sensitivity and specificity of ammonia was 85% and 86% in dogs, and 83% and 76% in cats, respectively. The sensitivity and specificity of SBA was 93% and 67% in dogs, and 100% and 71% in cats, respectively. Using optimal cut‐off points for ammonia (dogs, 57 μmol/L; cats, 94 μmol/L) the sensitivity and specificity was 91% and 84% in dogs and 83% and 86% in cats, respectively. Using optimal cut‐off points for SBA (dogs, 58 μmol/L; cats, 34 μmol/L) the sensitivity and specificity was 78% and 87% in dogs and 100% and 84% in cats. Conclusion: Increased fasting ammonia and SBA concentrations are accurate indicators of PSS. An improvement in diagnostic accuracy can be achieved by using defined optimal cut‐off points for the selective diagnosis of PSS.  相似文献   

7.
AIMS: To determine current practices and attitudes towards vaccination of dogs and cats of veterinarians in New Zealand; the methods used for informing clients on which vaccines to use, and the preferred site for vaccination of cats.

METHODS: A postal questionnaire was sent to all 483 listed veterinary practices in New Zealand during February 2012. Some questions were specific to pet dogs, cats, or working farm dogs. Responses were categorised according to practice type and geographical region of the respondent. Factors associated with respondent recommendation of annual vaccination with modified live viral (MLV) vaccines were examined using logistic regression analysis. Vaccines that were considered to be essential for every animal were defined as core; those that may be recommended for animals whose location or lifestyle placed them at risk, were defined as non-core.

RESULTS: There were 204 useable returns, equivalent to a response rate of 42.2%, distributed across the country. Annual vaccination with MLV vaccines of dogs was recommended by 54/198 (27.3%) respondents, and of cats by 107/181 (59.1%) respondents. Factors associated with the recommendation of annual administration of MLV vaccines to dogs included being a companion animal practice, a desire for policies on vaccination to be left to individual clinics, and having one veterinarian in the practice. Administration of the final vaccination for puppies was recommended at ≥14 weeks old by 55/185 (29.7%) respondents, and for kittens at ≥13 weeks old by 42/183 (23%) respondents. Of respondents that administered MLV vaccines annually, 62/103 (60.2%) believed reducing the frequency of vaccination would reduce income, and 52/103 (50.5%) considered it would have a negative effect on animal health. Advice to enable clients to decide which non-core vaccines were administered was given by 181/199 (91%) respondents. Factors considered when recommending a vaccine included consideration of risk to individual patients (190/203; 93.6%), requirements of boarding kennels/catteries (165/203; 81.3%) and clinic vaccination policy (142/203; 70%). The preferred site for administering MLV vaccines to cats was the dorsal neck or inter-scapular region (137/198; 69.2%). Amongst respondents, 18 wanted disease surveillance information to allow for truly informed decisions to be made about vaccination.

CONCLUSIONS AND CLINICAL RELEVANCE: Veterinarians can now compare their own vaccination practices and attitudes with those of veterinarians nationally, and internationally. There is a need for national surveillance information and for continued education of the public and commercial kennel and cattery owners for optimal vaccination strategies to be developed.  相似文献   


8.
Objective   To identify veterinarians' approaches and concerns when managing canine and feline patients with acute and chronic seizure disorders.
Design   Cross-sectional survey.
Method   A questionnaire was distributed to veterinarians to determine how many dogs and cats they were actively treating for seizures, their anticonvulsant drug (ACD) preferences for treating acute and chronic seizure disorders and whether serum anticonvulsant concentrations and/or biochemical analytes were routinely measured. Additional questions involved the respondent's year and place of graduation and identified concerns they faced when managing patients with seizure disorders.
Results   Phenobarbitone was the most commonly used ACD for managing chronic seizure disorders in both dogs and cats, with 82% of respondents using a combination of phenobarbitone and potassium bromide to manage refractory seizure disorders in dogs. Most respondents (96%) felt comfortable managing seizures in dogs, but only 63% were comfortable managing affected cats. Routine monitoring of serum ACD concentrations and of liver biochemical analytes was performed routinely by 71% and 45% of respondents, respectively. Of the respondents, 86% graduated from Australian universities and of these 53% had graduated after 1985.
Conclusion   Veterinarians identified when to commence medication, whether regular monitoring of serum ACD concentrations and liver enzyme activity was necessary, and if the cost was justified. Veterinarians also identified the need to balance dose rates and side-effects by using combination therapy, and the importance of providing accurate information to clients about what to expect in terms of seizure control for their pet.  相似文献   

9.
10.
The magnetic resonance (MR) imaging features of central nervous system lymphoma in eight dogs and four cats are described. Intracranial lesions affected the rostrotentorial structures in six dogs and caudotentorial structures in two cats. Lesions affected the spinal cord in two dogs and in two cats. One dog and one cat with intracranial lymphoma had signs of local extracranial extension and lymphadenopathy. Lesions were considered extraparenchymal in four dogs and three cats, intraparenchymal in two dogs and one cat, and appeared to have both intra- and extraparenchymal components in two dogs. All lesions were hyperintense in T2-weighted images when compared to white matter, most were hypointense in T1-weighted images (7/12), and most were hyperintense in fluid-attenuated inversion recovery (FLAIR) images (5/9). When compared to grey matter, these lesions appear either isointense (5/12) or hyperintense (7/12) on T2-weighted images, half of them were hypointense in T1-weighted images (6/12), and most were isointense in FLAIR images (7/9). Lesion margins were usually indistinct in T2-weighted images (10/12) and had perilesional hyperintensity in FLAIR images (7/9). The majority of lesions (10/12) had abnormal meninges around the lesion and half (6/12) had generalized contrast enhancement. Mass effect was evident in all lesions. Although not specific, when combined with the history and neurologic signs, MR features aid presumptive diagnosis that should be confirmed by cytology or histopathology.  相似文献   

11.
Objective Evaluation of five pulse oximeters in dogs, cats and horses with sensors placed at five sites and hemoglobin saturation at three plateaus. Study design Prospective randomized multispecies experimental trial. Animals Five healthy dogs, cats and horses. Methods Animals were anesthetized and instrumented with ECG leads and arterial catheters. Five pulse oximeters (Nellcor Puritan Bennett‐395, NPB‐190, NPB‐290, NPB‐40 and Surgi‐Vet V3304) with sensors at five sites were studied in a 5 × 5 Latin square design. Ten readings (SpO2) were taken at each of three hemoglobin saturation plateaus (98, 85 and 72%) in each animal. Arterial samples were drawn concurrently and hemoglobin saturation was measured with a co‐oximeter. Accuracy of saturation measurements was calculated as the root mean squared difference (RMSD), a composite of bias and precision, for each model tested in each species. Results Accuracy varied widely. In dogs, the RMSD for the NPB‐395, NPB‐190, NPB‐290, NPB‐40 and V3304 were 2.7, 2.2, 2.4, 1.7 and 2.7% respectively. Failure to produce readings for the NPB‐395, NPB‐190, NPB‐290, NPB‐40 and V3304 were 0, 0, 0.7, 0, and 20%, respectively. The Pearson correlation coefficients for the tongue, toe, ear, lip and prepuce or vulva were 0.95, 0.97, 0.69, 0.87 and 0.95, respectively. In horses, the RMSD for the NPB‐395, NPB‐190, NPB‐290, NPB‐40 and V3304 were 3.1, 3.0, 4.7, 3.3 and 2.1%, respectively while rates of failure to produce readings were 10, 21, 0, 17 and 60%, respectively. The Pearson correlation coefficients for the tongue, nostril, ear, lip and prepuce or vulva were 0.98, 0.94, 0.88, 0.93 and 0.94, respectively. In cats, the RMSD for all data for the NPB‐395, NPB‐190, NPB‐290, NPB‐40 and V3304 were 5.9, 5.6, 7.9, 7.9 and 10.7%, respectively while failure rates were 0, 0.7, 0, 20 and 32%, respectively. The correlation coefficients for the tongue, rear paw, ear, lip and front paw were 0.54, 0.79,.0.64, 0.49 and 0.57, respectively. For saturations above 90% in cats, the RMSD for the NPB‐395, NPB‐190, NPB‐290, NPB‐40 and V3304 were 2.6, 4.4, 4.0, 3.5 and 4.8%, respectively, while failure rates were 0, 1.7, 0, 25 and 43%, respectively. Conclusions and clinical relevance Accuracy and failure rates (failure to produce a reading) varied widely from model to model and from species to species. Generally, among the models tested in the clinically relevant range (90–100%) RMSD ranged from 2–5% while failure rates were highest in the V3304.  相似文献   

12.
13.
We report the results of validation of canine serum cortisol determination with the Immulite 2000 Xpi cortisol immunoassay (Siemens), with characterization of precision (CV), accuracy (spiking-recovery [SR] bias), and observed total error (TEo = bias + 2CV) across the reportable range, specifically at the most common interpretation thresholds for dynamic testing. Imprecision increased at increasing rate with decreasing serum cortisol concentration and bias was low, resulting in increasing TEo with decreasing serum cortisol concentration. Inter-laboratory comparison study allowed for determination of range-based bias (RB) and average bias (AB). At 38.6 and 552 nmol/L (1.4 and 20 μg/dL), between-run CV was 10% and 7.5%, respectively, and TEo ~30% and ~20%, respectively (TEo remained similar regardless of the considered bias: SR, RB, or AB). These analytical performance parameters should be considered in the interpretation of results and for future expert consensus discussions to determine recommendations for allowable total error (TEa). Importantly, the commonly used thresholds for interpretation of results were determined ~40 y ago with different methods of measurements and computation, hence updating is desirable. Quality control material (QCM) had between-run imprecision of 4% for QCM1 and 7% for QCM2; the bias was minimal for both levels. Acceptable QC rules are heavily dependent on the desired TEa for the QCM system (TEaQCM), itself limited by the desired clinical TEa. At low TEaQCM (20–33%), almost no rules were acceptable, whereas at high TEaQCM (50%), almost all rules were acceptable; further investigation is needed to determine which TEaQCM can be guaranteed by simple QC rules.  相似文献   

14.
Blood, saliva, and nail samples were collected from 54 dogs and 151 cats and analyzed for the presence of Bartonella henselae with a novel nested polymerase chain reaction (PCR) method. Bartonella (B.) henselae was detected in feral cat blood (41.8%), saliva (44.1%), and nail (42.7%) samples. B. henselae was also detected in pet cat blood (33.3%), saliva (43.5%), and nail (29.5%) samples and in pet dog blood (16.6%), saliva (18.5%), and nail (29.6%) samples. Nine samples were infected with B. clarridgeiae and 2 were co-infected with B. henselae and B. clarridgeiae of blood samples of dogs. This report is the first to investigate the prevalence of B. henselae and B. clarridgeiae in dogs and cats in Korea, and suggests that dogs and cats may serve as potential Bartonella reservoirs.  相似文献   

15.
16.
Determining a simple quality control (QC) rule for daily performance monitoring depends on the desired total allowable error (TEa) for the measurand. When no consensus TEa exists, the classical approach of QC rule validation cannot be used. Using the results of previous canine serum and urine cortisol validation studies on the Immulite 2000 Xpi, we applied a reverse engineering approach to QC rule determination, arbitrarily imposing sigma = 5, and determining the resulting TEa for the QC material (QCM; TEaQCM) and the resulting probability of error detection (Ped) for each QC rule. For the simple QC rule 12.5S with Ped = 0.96 and probability of false rejection (Pfr) = 0.03, the associated TEaQCM were 20% and 35% for serum and 28% and 24% for urine QCM1 and QCM2. If these levels of TEaQCM are acceptable for interpretation of patient sample results, then users can internally validate the 12.5S QC rule, provided that their QCM CVs and biases are similar to ours. Otherwise, more stringent QC rules can be validated by using a lower sigma to lower the TEaQCM. With spiked samples (relevant cortisol concentrations in the veterinary patient matrix) at 38.6 and 552 nmol/L of cortisol, TEaQCM at sigma = 5 were much higher (54% and 40% for serum; 90.3% and 42.8% for urine). Spiked samples generate TEa that is probably too high to be suitable for daily QC monitoring; however, it is crucial to verify spiked sample observed total error (TEo; 26% and 18% for serum, 60% and 30% for urine) < TEaQCM, and to use spiked sample TEo for patient result interpretation. In the absence of consensus TEa for cortisol in dogs, we suggest the use of a 12.5S rule, provided that users accept the associated level of TEaQCM also as clinical TEa for results interpretation.  相似文献   

17.
18.
19.
犬猫传染性疾病严重影响犬、猫健康,甚至威胁人类生命健康。随着新型材料和科学技术的发展,在传统检测方法的基础上建立了多种快速、灵敏、特异的检测技术。针对研究较多的快速检测方法如等温扩增技术、基因芯片技术、时间分辨免疫荧光层析技术以及免疫微球分离检测技术等多种新型检测技术,从检测时间、优缺点及在犬猫主要病原检测的研究进展等多角度予以综述,旨为在不同的检测环境下选择适合犬猫病原检测技术及产品研发提供参考。  相似文献   

20.
ObjectivesAn ultrasound (US)-guided ventral suprainguinal approach to block the femoral nerve (FN) within the iliopsoas muscle (IPM) has recently been described in dogs. The goal of the present study was to provide the operator with additional information to locate the FN within the IPM in dogs and cats using US.Study designThe study was carried out in three phases: a dissection of the FN (phase 1); an in vivoUS-assisted nerve study (phase 2), and an anatomical cross-sectional study (phase 3).AnimalsNine healthy adult beagle dogs and nine healthy adult cats.MethodsDissections were performed to investigate the anatomical characteristics of the FN and its related structures in one dog and one cat. Ultrasound scans of the left and right FN were performed in eight dogs and eight cats. The FN diameter and the distance between the FN and the external iliac artery (EIA) in US images and in anatomical cryosections were measured.ResultsThe median FN diameter did not differ significantly between cats and dogs (1.1 mm versus 1.0 mm) or between the two techniques (US versus anatomical cross-sectional study) (1.1 mm versus 1.1 mm in dogs; 1.0 mm versus 1.1 mm in cats). The US and anatomical measurements of the median distances between the FN and EIA differed significantly between dogs and cats (8.2 mm versus 5.8 mm by US; 5.7 mm versus 4.8 mm in the anatomical study).Conclusions and clinical relevanceThe distance between the EIA and FN is reproducible in beagle dogs and cats and can be used in locating the FN within the IPM.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号