首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
OBJECTIVE: Evaluation of use of a supernumerary teat as a pedicle graft to repair experimental teat tip damage in cattle. STUDY DESIGN: Experimental study. ANIMALS: Mature, non-gravid hybrid cows with > or =1 supernumerary teat. METHODS: The main teat and adjacent supernumerary teat were examined for patency by ultrasound with a 8 MHz linear array transducer. The tip of the main teat was resected at the junction of cistern and canal. The supernumerary teat was partially resected semi-circumferentially at the cranial aspect of the base to maintain vascular supply and transplanted by end-to-end anastomosis. The pedicle of the supernumerary teat graft was amputated in stages starting at 14 days, again at 16 days and separated at 18 days. Reconstructed teat patency was evaluated at intervals by ultrasonography and confirmed at 50 days by histopathology. Repeated measures ANOVA was used to compare the measurements of luminal diameter between days; significance was set at P<.05. RESULTS: All reconstructed teats were patent. Decreased luminal diameters were detected at 25, 32, 39, and 46 days by ultrasonography. On histopathology, granulation and epithelial (mucosal) proliferation contributed to luminal reduction. CONCLUSIONS: In this experimental model of an acute damage to a teat tip, supernumerary teat grafting was successfully used to restore teat anatomy. CLINICAL RELEVANCE: Supernumerary teat pedicle grafting may be considered as a salvage technique for reconstruction of a damaged bovine teat in cows that have an adjacent patent supernumerary teat. Function of the reconstructed teat in a lactating cow remains unknown.  相似文献   

2.
OBJECTIVE: To evaluate 3-dimensional (3-D) ultrasonography of the bovine mammary gland, particularly of the teat. ANIMALS: 6 lactating cows. PROCEDURES: Clinical and ultrasonographic examinations of mammary glands of each cow were performed. Teats were removed from a slaughtered cow and examined via ultrasonography. All scans were performed by use of a sensorless standard transducer (8.5 to 10 MHz linear array). The 2-dimensional data acquired were downloaded to an off-line system, and software was used to digitize each image and produce a 3-D block of digitized information. The selected anatomic area was displayed as a 3-D volume cube. RESULTS: Good-quality, 3-D views of the entire mammary gland were acquired by obtaining sections through the glandular parenchyma, gland cistern, teat cistern, and teat canal. CONCLUSIONS AND CLINICAL RELEVANCE: 3-D ultrasonography allows perspective images of the mammary gland to be obtained. Many scanners routinely used in veterinary practice have the resolution required to produce satisfactory images, and the cost of refitting a standard ultrasonographic unit with 3-D software is affordable; however, the cost of a volume transducer with a positioning system and mechanical sweep strategy may be prohibitive. Three-dimensional ultrasonography is a new imaging technique that has promising applications in many fields of veterinary medicine.  相似文献   

3.
The udders and teats of cows were examined by brightness mode (B-mode) ultrasonography. A 5-MHz linear array transducer and a 5-MHz or 10-MHz mechanical sector transducer were used in the examinations. In lactating animals, the teat sinus, gland sinus, and lactiferous ducts were imaged easily. The scans also allowed visualization of the layers of the teat wall. The annular fold and the folding of the mucosa at the junction of the teat sinus and the papillary duct were seen best with the 5-MHz and 10-MHz mechanical sector transducers. In one cow lacking milk flow from one quarter, a mass at the junction of the papillary duct and the teat sinus was observed ultrasonographically. Surgical removal of the mass resulted in a return of milk flow from that quarter.  相似文献   

4.
AIM: To compare clinical and ultrasonographic findings and assess the value of ultrasonography for evaluating the structure and condition of the teat and teat canal of sheep. METHODS: The mammary glands of 30 lactating ewes were examined clinically and using ultrasonography. The distance from the teat tip to the ground was measured and diagnostic images of the body of the gland, gland cistern and teat cistern were obtained using an 8.5 MHz frequency ultrasonic transducer. A California mastitis test (CMT) and bacteriological culture were performed on milk samples collected from each half of each udder. RESULTS: Udder parenchyma and teats were palpably normal in 27/30 (90%) ewes. Milk clots or abnormalities were evident in 4/30 (13%) udders, lesions in the glandular parenchyma and/or teats were evident by palpation in 3/30 (10%), and pathogenic bacteria were cultured from 2/30 (7%). In both of the latter cases, mastitis was diagnosed based on clotted and discoloured appearance of milk and highly positive CMT reactions. Ultrasonographic examination in these udders revealed non-homogenous regions in the glandular tissue and alternating areas of hyperechogenic and hypoechogenic tissue. Overall, highly positive CMT reactions were evident in milk from 14/30 (47%) left halves and 9/30 (30%) right halves (p=0.02). No relationship between teat-to-ground distances and CMT results was evident (p>0.05). Teat canal lengths ranged from 5.7-10.3 mm (mean=8.6; SD=1.3 mm) and the widths from 1.8-3.1 mm (mean=2.3; SD=0.4 mm). Milk sampled from ewes that had long (> or = 9 mm) or wide (> or = 2 mm) teat canals was highly positive to the CMT in 75% and 83% of cases, respectively. CONCLUSIONS: Ultrasonographic measurements of the length and width of the teat canal appeared to correlate with CMT results. The use of ultrasonography in evaluating the health of the udder of small ruminants holds promise for the future.  相似文献   

5.
AIM: To compare clinical and ultrasonographic findings and assess the value of ultrasonography for evaluating the structure and condition of the teat and teat canal of sheep.

METHODS: The mammary glands of 30 lactating ewes were examined clinically and using ultrasonography. The distance from the teat tip to the ground was measured and diagnostic images of the body of the gland, gland cistern and teat cistern were obtained using an 8.5 MHz frequency ultrasonic transducer. A California mastitis test (CMT) and bacteriological culture were performed on milk samples collected from each half of each udder.

RESULTS: Udder parenchyma and teats were palpably normal in 27/30 (90%) ewes. Milk clots or abnormalities were evident in 4/30 (13%) udders, lesions in the glandular parenchyma and/or teats were evident by palpation in 3/30 (10%), and pathogenic bacteria were cultured from 2/30 (7%). In both of the latter cases, mastitis was diagnosed based on clotted and discoloured appearance of milk and highly positive CMT reactions. Ultrasonographic examination in these udders revealed non-homogenous regions in the glandular tissue and alternating areas of hyperechogenic and hypoechogenic tissue. Overall, highly positive CMT reactions were evident in milk from 14/30 (47%) left halves and 9/30 (30%) right halves (p=0.02). No relationship between teat-to-ground distances and CMT results was evident (p>0.05). Teat canal lengths ranged from 5.7–10.3 mm (mean=8.6; SD=1.3 mm) and the widths from 1.8–3.1 mm (mean=2.3; SD=0.4 mm). Milk sampled from ewes that had long (≥9 mm) or wide (≥2 mm) teat canals was highly positive to the CMT in 75% and 83% of cases, respectively.

CONCLUSIONS: Ultrasonographic measurements of the length and width of the teat canal appeared to correlate with CMT results. The use of ultrasonography in evaluating the health of the udder of small ruminants holds promise for the future.  相似文献   

6.
Most pathogens that cause bovine mastitis invade the udder lumen through the teat canal. Amino acids and intercellular lipids may support microbial colonisation of the teat canal epithelium by pathogenic microorganisms. The aim of this study was to investigate the association between teat end hyperkeratosis, which is induced by machine milking, and teat canal microbial load. Contralateral teats, which differed in teat end hyperkeratosis scores, were identified in a split-udder experiment. The teat canal's microbial load was evaluated using the wet and dry swab technique. Staphylococcus (S.) aureus, Streptococcus (Sc.) uberis, Escherichia (E.) coli and other coliforms were detected by agar plate cultures. The positive detection of E. coli and the log(10)-transformed E. coli load of a teat canal were significantly associated with the teat end hyperkeratosis score (P<0.05). There were significant differences with respect to positive findings for E. coli, as well as the microbial load of E. coli and Sc. uberis, between the less-calloused and the more-calloused teat of a pair. For S. aureus, no significant associations between hyperkeratosis score and teat canal microbial load were detected. In general, a teat with a highly calloused teat end had an increased teat canal microbial load compared with the contralateral teat, characterised by a lower callosity. The results of the present study indicate that the environmental pathogen load is associated with teat end hyperkeratosis. Further research is needed to identify factors that may affect teat canal microbial load in lactating dairy cattle.  相似文献   

7.
Morphological structures of the bovine Papilla mammae can be differentiated with portable ultrasound units and 5 MHz linear arrays. For practical use it is possible to scan the teat in a water-filled plastic cup as a kind of water delay system. The visualization of pathological findings shows a possibility to evaluate this method as a diagnostic tool for the bovine teat.  相似文献   

8.
The effect of postmilking teat dipping with a foaming iodophor agent on incidence of intramammary infections (IMI), incidence of clinical mastitis, somatic cell count and the characteristics of udder tissue and teat was investigated in a positively controlled field study. Two groups of animals were compared. Teats were dipped with a foaming iodophor in the treatment group (TG, 122 animals) while teats in the control group (CG, 121 animals) were dipped with a conventional iodophor teat dip with the same iodine content. A bacteriological examination of quarter milk samples divided the study period in two parts. The incidence of new IMI did not differ between the groups (1st part of trial: TG vs. CG: 6.84% vs. 9.16%, 2nd part of trial: 7.78% vs. 7.82%). There were no differences between the treatment groups regarding incidence of clinical mastitis. We detected 0.64 clinical cases per 100 days in the treatment group vs. 0.50 in the control group. The development of SCC was comparable in both groups. Teat skin and teat duct conditions showed variation during the study period. Clinical efficacy of postmilking teat disinfection with a foaming iodophor was comparable to the treatment with a conventional iodophor product.  相似文献   

9.
Urocystoliths of 9 mineral types from 437 canine patients submitted to the University of Minnesota Urolith Bank were imaged in a urinary bladder phantom. Imaging techniques simulated were survey radiography, pneumocystography, double contrast cystography (two iodine concentrations) and real-time ultrasonography (3.5 MHz, 5.0 MHz, 7.5 MHz). Imaging techniques were compared for accuracy of urocystolith detection, accuracy of urocystolith enumeration, and tendencies for over or undercounting. Across urocystolith mineral types, the false negative rates (no urocystoliths detected in a given case) for survey radiographs range from 2 to 27%. Pneumocystographic techniques are one-half as likely to yield false negative results as are survey radiographic techniques. Underestimates of urocystolith numbers and false negatives are likely using 80 mg iodine/ml double contrast cystography because calcium-based urocystoliths are isopaque in this contrast medium dilution. The 200 mg iodine/ml double contrast cystographic techniques are unlikely to yield false negative diagnoses even for very small (< or = 1.0 mm) urocystoliths and is comparable to pneumocystography for detection and slightly better for enumeration. The likelihood of an ultrasonographic false negative for urocystoliths decreases with increasing MHz. Under optimal conditions using a 7.5 MHz mechanical sector transducer, the false negative rates were comparable to double contrast cystography, but rates increased notably with lower MHz transducers.  相似文献   

10.
Changes in the microscopic anatomy of the bovine teat canal were examined during mammary involution. Morphometric analyses revealed a significant (P less than 0.05), temporary dilatation of the teat canal lumen on day 7 of the nonlactating period. Additionally, the teat canal epithelium physiologically atrophied as evidenced by decreased cross-sectional area and thickness during the first 30 days of the nonlactating period, significantly so (P less than 0.05) between days 0 and 7. This physiologic atrophy was due mainly to a reduction in area and thickness of the stratum granulosum and may have resulted from continuing keratinization, a process that led to increased thickness of the keratin layer and formation of a functional plug during later stages of involution. Changes in cells of the stratum granulosum indicated a decrease in the rate of epithelial cell maturation during involution. The mitotic index (percentage of basal cells in mitosis) of the teat canal epithelium decreased significantly (P less than 0.05) between days 0 and 7 of the nonlactating period. Bacteria, observed in histologic sections, appeared to colonize only certain regions of the keratin layer. Seemingly, changes in the teat canal during mammary involution may be important factors in changing susceptibility to new intramammary infection during the early and mid-nonlactating periods.  相似文献   

11.
The aim of the present study was to evaluate to what extent the distal tibia and the trochlear ridges of the talus can be examined with ultrasound (US) in the dog and to establish a protocol for an optimal US examination of these ridges. Six hind limbs of deceased adult mixed-breed dogs were used. In two limbs, needles were placed using US guidance on the trochlea of the talus, just dorsal to and plantar to the distal tibia: one with the tarsal joint in extension and one with the joint in flexion. Then mediolateral (ML) radiographs of both joints were made with the needle in place to determine the percentage of the trochlear ridge of the talus that can be seen using US imaging. An US examination of the tarsal joint was performed on the four other limbs using microconvex (8 MHz) and linear (12 MHz) transducers (Logiq 7) and compound imaging. A three-step protocol was performed including a dorsal approach with the limb extended and the linear transducer (step I), a plantar approach with the limb flexed and the linear transducer (step II), and a plantar approach with the limb flexed and the microconvex transducer (step III). After the US examination, the four limbs were frozen and sectioned, two in a transverse and two in a sagittal plane. Bony structures on the US images were matched with the corresponding anatomic sections. The distal tibia and both trochlear ridges of the talus were easily recognized on the US images using the proposed protocol. When combining the dorsal and plantar approaches, it was possible to visualize up to 75% of the trochlear ridges of the talus in the dog.  相似文献   

12.
Relative blood flow to tissues of the distal part of the teat (mammary papilla) in 5 lactating dairy cows was determined, using 15-microns nonradioactive carbonized microspheres. Highest relative blood flow occurred in the epithelial region (zone A) of the teat canal (papillary duct) which comprised both teat canal epithelium and papillated portion of the stratum papillare. Blood flow to these tissues was more than 4 times greater than blood flow to equivalent tissues of the mucosal rosette. The high rate of metabolic activity indicated by this relatively high blood flow may be required to support secretion of antimicrobial substances and continual synthesis of epithelial cells to replace those lost during milking.  相似文献   

13.
Six cadaver pelvic limbs were obtained from clinically sound dromedary camels and examined radiographically and ultrasonographically using a 7.5 MHz convex transducer. Radiographic examination was performed in dorsoplantar, lateromedial, dorsolateral‐plantaromedial oblique and plantarolateral‐dorsomedial oblique projections, and the bony structures and articulations of the tarsal joint were outlined. The tarsus was ultrasonographically investigated in four planes (dorsal, medial, lateral and plantar), and each plane was scrutinized in four levels (calcaneal tuber, tibial malleoli, base of calcaneus and proximal end of metatarsus) in both transverse and longitudinal views. Limbs were examined grossly, frozen at ?20°C and sectioned. Radiographic and ultrasonographic findings correlated well with the gross anatomy and frozen sections. The normal appearance of bony and soft structures of the tarsus described in this study provided basic reference data for ultrasonographic and radiographic investigations of tarsal disorders in the dromedary camel.  相似文献   

14.
TRANSESOPHAGEAL ULTRASONOGRAPHY OF THE NORMAL CANINE MEDIASTINUM   总被引:1,自引:0,他引:1  
The mediastinum of eight normal research dogs was examined by transesophageal ultrasonography with a 5MHz frequency transducer to establish a baseline for future use of this new imaging modality as a diagnostic tool. Each examination consisted of 360 degree scans in both transverse and sagittal planes from the thoracic inlet to the esophageal hiatus. Dissections of four of these research dogs were then performed to confirm transesophageal ultrasonography findings. Transesophageal ultrasonography of the mediastinum was a good imaging modality for the evaluation of the heartbase, the major cranial mediastinal vessels, the descending aorta, and occasionally part of the azygos vein. Anatomic orientation was best obtained by beginning the examination at the heart base. Lymph nodes and smaller caliber vessels could not be distinguished from surrounding tissues; however, Doppler ultrasound was useful for identifying the smaller vessels. Although a 5 MHz frequency transducer is preferred for transesophageal echocardiography, a higher frequency transducer would improve the resolution of the images of small near-field structures and may be more appropriate for mediastinal imaging.  相似文献   

15.
The purpose of this study was the long-term evaluation of a method of surgically repairing the abnormal condition of accessory teat and gland cistern complexes in dairy cattle. A prospective evaluation of three cows that had undergone the procedure was done. These cows were evaluated from four months to one year, postoperatively. A thorough history, physical examination, contrast radiography, and ultrasonic examination were done on each cow. A retrospective evaluation of an additional 13 cows that had also undergone the procedure was obtained four months to three years following the surgery, via owner communication. The prospective portion of this study demonstrated patency of the communication between main and accessory teat cisterns. Postoperative complications included initial slow milking and mild swelling of the involved teat. These problems resolved in all cows one to two months postoperatively. None of the 16 cows that had undergone the surgery either developed or was treated for mastitis. Likewise, none of these cows was sold or slaughtered as a result of postoperative teat problems or unsatisfactory milk production. Our study demonstrated that this particular method of surgical correction of accessory teat and gland cistern complexes is effective, is esthetically acceptable, produces minimal associated complications, and preserves the milk production capacity of the gland.  相似文献   

16.
This review deals with the relevant literature about the application of ultrasonography in udder diagnosis especially in stenosis of the teat in cattle. Ultrasonic devices, frequencies and ultrasonic techniques are discussed. It seems that under practical conditions, a 5 MHz linear scanner might be sufficient. Compared with radiography, ultrasonography gave better results in high and medium stenoses of the teat. The results of these first investigations demonstrated that with the development of suitable devices and techniques, ultrasonography might be of high importance as an additional and supporting technique for the diagnosis of stenoses of the teat.  相似文献   

17.
Paul  Y  Barthez  DVM  René  Léveillé  DVM  Peter  V  Scrivani  DVM 《Veterinary radiology & ultrasound》1997,38(5):387-393
Side lobes and grating lobes are both unwanted parts of the ultrasound beam emitted off axis that produce image artifacts due to error in positioning the returning echo. The purpose of this study was to reproduce artifacts associated with side lobes and grating lobes in vitro using different transducer types and recognize these artifacts in vivo. A phantom, composed of a water bath, a metallic wire, and a wooden tongue depressor, was imaged using a linear array, a curved linear array, a vector array, and a sector mechanical transducer. When imaging the metallic wire in a transverse plane, an echogenic artifact was constantly seen on each side of the wire, with a shape and intensity variable with the transducer type. The artifact was curvilinear and concave (linear and curved linear arrays), or curvilinear and convex (vector array and the mechanical transducer). When the tongue depressor was imaged in a longitudinal plane, the artifact was a straight line (linear array), a curved convex line(curved array), a series of convex curvilinear echo (vector array) or a small convex curvilinear echo (mechanical transducer). In vivo situations similar to the phantom experiment were investigated using clinical patients. Artifacts produced in vitro were recognized in vivo when a highly reflective object (urinary bladder wall) was imaged adjacent to an anechoic region (urine). These artifacts corresponded to the principle of secondary ultrasound lobes, and were therefore interpreted as such.  相似文献   

18.
In this study we investigated the efficacy of premilking teat dipping with a foaming iodophor teat dip in a negative controlled field study. Incidence of new intramammary infections (IMI), incidence of clinical mastitis, influence on somatic cell count (SCC) and the characteristics of udder tissue and teats were used as parameters to evaluate clinical efficacy. Predipping was compared with a negative control using a split-udder experimental design. Right teats were predipped with a foaming disinfectant containing 0.27% iodine while left teats served as controls. The latter were conventionally cleaned with damp cloth towels and dried manually with disposable paper towels ("best cleaning practice"). All teats were dipped after milking with the same dip. There were no differences between treated and control quarters with respect to incidence of new IMI during the study period (treated quarters: 6.6% vs. untreated: 6.95%), incidence of clinical mastitis (30 cases in the treatment group vs. 39 cases in the control group) and geometric mean of SCC of quarter milk samples. Spectrum of detected pathogens was also comparable. Condition of udder tissue and teat ducts did not differ between treated and control quarters.  相似文献   

19.
A high number of dairy heifers freshen with udder health problems. The prevalence of teat apex colonization (TAC) with Staphylococcus chromogenes, one of the most widespread coagulase-negative staphylococci (CNS) in milk samples from freshly calved dairy heifers, was measured cross-sectionally in non-lactating heifers on eight commercial dairy farms in Belgium. The influence of age on this prevalence, and the association between teat apex colonization with S. chromogenes prepartum and quarter milk somatic cell count (SCC) in early lactation were studied. In total, 492 teat apices were sampled from 123 heifers. The age of the heifers varied from 8 to 34 months. Overall, 20% of the heifers had at least one teat apex colonized with S. chromogenes. Of all teats sampled, 10% were colonized with S. chromogenes. The chance of having at least one teat apex colonized with S. chromogenes increased with age of the heifer. The presence of prepartum teat apex colonization with S. chromogenes was not associated with intramammary infection (IMI) early postpartum with the same bacterium. On the contrary, teat apex colonization with S. chromogenes prepartum appeared to protect quarters in the first few days of lactation from having somatic cell count >or=200000cells/ml milk, commonly accepted as the threshold for intramammary infection.  相似文献   

20.
Out of 700 heifers at a local farm in Hokkaido, the Northern island of Japan, 560 (80%) were found to have benign teat tumors. All of the analyzed tumors were macroscopically of the flat-and-round type, and no other types such as rice-grain or frond epithelial type were found. The lesions were characterized by epithelial hyperplasia, acanthosis and hyperkeratosis. Unlike in typical fibropapilloma, fibroplasia of the underlying dermis was not observed. Bovine papilloma virus (BPV) capsid antigen and virus particles were found in basophilic intranuclear inclusions of the stratum granulosum of the epidermis by immunohistochemistry and electron microscopy, respectively. BPV-specific DNA was also detected in the lesions. By means of the polymerase chain reaction (PCR) and DNA sequencing of the PCR products, the viruses causing this outbreak were identified mainly as BPV-6 (64%), partly as unclassified BPVs (14%) and their co-infections (21%). Our findings suggest that this outbreak of benign teat tumors was associated with several BPV types.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号