首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 61 毫秒
1.
2.
3.
OBJECTIVE: To determine the median effective dose (ED(50); equivalent to the minimum alveolar concentration [MAC]) of isoflurane, sevoflurane, and desflurane for anesthesia in iguanas. ANIMALS: 6 healthy adult green iguanas. PROCEDURE: In unmedicated iguanas, anesthesia was induced and maintained with each of the 3 volatile drugs administered on separate days according to a Latin square design. Iguanas were endotracheally intubated, mechanically ventilated, and instrumented for cardiovascular and respiratory measurements. During each period of anesthesia, MAC was determined in triplicate. The mean value of 2 consecutive expired anesthetic concentrations, 1 that just permitted and 1 that just prevented gross purposeful movement in response to supramaximal electrical stimulus, and that were not different by more than 15%, was deemed the MAC. RESULTS: Mean +/- SD values for the third MAC determination for isoflurane, sevoflurane, and desflurane were 1.8 +/- 0.3%, 3.1 +/- 1.0%, and 8.9 +/- 2.1% of atmospheric pressure, respectively. The MAC for all inhaled agents was, on average, 22% greater for the first measurement than for the third measurement. CONCLUSIONS AND CLINICAL RELEVANCE: Over time, MACs decreased for all 3 agents. Final MAC measurements were similar to values reported for other species. The decrease in MACs over time may be at least partly explained by limitations of anesthetic uptake and distribution imposed by the reptilian cardiorespiratory system. Hence, for a constant end-tidal anesthetic concentration in an iguana, the plane of anesthesia may deepen over time, which could contribute to increased morbidity during prolonged procedures.  相似文献   

4.
OBJECTIVE: To evaluate bispectral index (BIS) values in pigs during anesthesia maintained with sevoflurane-fentanyl or propofol-fentanyl as a predictor of changes in hemodynamic parameters and duration of recovery from anesthesia. ANIMALS: 12 pigs. PROCEDURE: Pigs were randomly allocated to undergo 1 of 2 anesthetic regimens. Anesthesia was induced with propofol (2 mg/kg, i.v.); 6 pigs were administered sevoflurane via inhalation (1 minimum alveolar concentration [MAC] at a fresh gas flow rate of 3 L/min; group I), and 6 were administered propofol (11 mg/kg/h, i.v.; group II). All pigs received fentanyl (2.5 mg/kg, i.v., q 30 min). After abdominal surgery, pigs were allowed to recover from anesthesia. Cardiovascular variables and BIS values were recorded at intervals throughout the procedure; duration of recovery from anesthesia was noted. RESULTS: No correlation was established between arterial blood pressure and BIS and between heart rate and BIS. Mean BIS at discontinuation of administration of the anesthetic agent was greater in group-II pigs (65.2 +/- 10.6 minutes) than in group-I pigs (55.8 +/- 2.9 minutes). However, recovery from anesthesia was significantly longer in group II (59.80 +/- 2.52 minutes) than in group I (9.80 +/- 2.35 minutes). CONCLUSIONS AND CLINICAL RELEVANCE: In swine anesthetized with sevoflurane or propofol and undergoing abdominal surgery, the BIS value derived from an electroencephalogram at the end of anesthesia was not useful for predicting the speed of recovery from anesthesia. Moreover, BIS was not useful as a predictor of clinically important changes in arterial blood pressure and heart rate in those anesthetized pigs.  相似文献   

5.
OBJECTIVE: To determine the effect of inhalation of isoflurane at end-tidal concentrations greater than, equal to, and less than the minimum anesthetic concentration (MAC) on bispectral index (BIS) in chickens. Animals-10 chickens. PROCEDURES: For each chicken, the individual MAC of isoflurane was determined by use of the toe-pinch method. After a 1-week interval, chickens were anesthetized with isoflurane at concentrations 1.75, 1.50, 1.25, 1.00, and 0.75 times their individual MAC (administered from higher to lower concentrations). At each MAC multiple, a toe pinch was performed and BIS was assessed and correlated with heart rate, blood pressure, and an awareness score (derived by use of a visual analogue scale). RESULTS: Among the chickens, mean +/- SD MAC of isoflurane was 1.15 +/- 0.20%. Burst suppression was detected at every MAC multiple. The BIS and awareness score were correlated directly with each other and changed inversely with increasing isoflurane concentration. Median (range) BIS values during anesthesia at 1.75, 1.50, 1.25, 1.00, and 0.75 MAC of isoflurane were 25 (15 to 35), 35 (25 to 45), 35 (20 to 50), 40 (25 to 55), and 50 (35 to 65), respectively. Median BIS value at extubation was 70 +/- 9. Values of BIS correlated with blood pressure, but not with heart rate. Blood pressure changed with end-tidal isoflurane concentrations, whereas heart rate did not. CONCLUSIONS AND CLINICAL RELEVANCE: Assessment of BIS can be used to monitor the electrical activity of the brain and the degree of unconsciousness in chickens during isoflurane anesthesia.  相似文献   

6.
OBJECTIVE: To determine whether the prestimulation bispectral index (BIS) value or relative change in BIS after noxious stimulation can be used to assess the depth of isoflurane anesthesia in cats. ANIMALS: 17 healthy female cats. PROCEDURE: Electroencephalogram (EEG) patterns and BIS values were examined in cats that received increasing end-tidal (ET) isoflurane concentrations. Subsequently, BIS values were determined before and after either a noxious somatic or visceral stimulus in cats that received ET isoflurane concentrations ranging from 1.8% to 2.4%. Electrical stimuli of the tail base and bladder distension to 50 cm of water were the somatic and visceral stimuli, respectively. RESULTS: he resting BIS at ET isoflurane concentrations from 1.4% to 1.9% steadily decreased concurrently with increasing degrees of EEG suppression. Prestimulation BIS values, however, were not related to 1.8% to 2.4% ET isoflurane concentrations and not useful for prediction of BIS values or hemodynamic and movement responses after a noxious stimulus. The poststimulation BIS value and the difference between mean BIS values before and after stimulation were inversely correlated with increasing ET isoflurane concentrations. Poststimulation BIS values > 60 were observed at ET isoflurane concentrations greater than those associated with a movement response after a stimulus. CONCLUSIONS AND CLINICAL RELEVANCE: The prestimulation BIS value has limited use in assessing anesthetic depth in cats during isoflurane anesthesia. The change in BIS values after a noxious somatic or visceral stimulus was a reliable measure of anesthetic depth and may be a useful measure of early arousal from the hypnotic state.  相似文献   

7.
OBJECTIVE: To determine the relationship between bispectral index (BIS) and minimum alveolar concentration (MAC) multiples of sevoflurane in cats. ANIMALS: 8 domestic cats. PROCEDURE: Each cat was anesthetized twice with sevoflurane. First, the MAC of sevoflurane for each cat was determined by use of the tail clamp method. Second, cats were anesthetized with sevoflurane at each of 5 MAC multiples administered in random order. Ventilation was controlled, and after a 15-minute equilibration period at each MAC multiple of sevoflurane, BIS data were collected for 5 minutes and the median value of BIS calculated. RESULTS: The mean (+/- SD) MAC of sevoflurane was 3.3 +/- 0.2%. The BIS values at 0.5 MAC could not be recorded as a result of spontaneous movement in all 8 cats. The BIS values at 2.0 MAC were confounded by burst suppression in all 8 cats. Over the range of 0.8 to 1.5 MAC, BIS values decreased significantly with increasing end-tidal sevoflurane concentrations. Mean (+/- SD) BIS measurements were 30 +/- 3, 21 +/- 3, and 5 +/- 2 at 0.8, 1.0, and 1.5 MAC, respectively. CONCLUSIONS AND CLINICAL RELEVANCE: Values of BIS are inversely and linearly related to end-tidal sevoflurane concentrations in anesthetized cats, and BIS may be a useful predictor of CNS depression in this species. The consistently low BIS values recorded in this study suggest that clinical BIS end points used to titrate anesthetic agents in humans may not be applicable to cats.  相似文献   

8.
Pigs are important animal models in veterinary and medical research and have been widely used in experiments requiring surgical anesthesia. Sevoflurane is an inhalant anesthetic with unique properties that make it an ideal anesthetic for mask induction and anesthesia maintenance. However, there are relatively few studies reporting the anesthetic requirements for sevoflurane in juvenile swine, an age group that is commonly used in research experiments. Therefore the objective of this study was to determine the Minimum Alveolar Concentration (MAC) for sevoflurane in juvenile swine. Sevoflurane anesthesia was induced in six Yorkshire-cross pigs of approximately 9 weeks-of-age and MAC for sevoflurane was determined. The sevoflurane MAC value was determined to be 3.5+/-0.1% which is notably higher than values reported in the literature for pigs. This discrepancy in MAC values may represent changes in anesthetic requirements between different age groups of pigs and differences in the type of stimulus used to determine MAC.  相似文献   

9.
OBJECTIVE: To determine induction characteristics and the minimum alveolar concentration (MAC) at which consciousness returned (MACawake) in dogs anesthetized with isoflurane or sevoflurane. ANIMALS: 20 sexually intact male Beagles. PROCEDURES: In experiment 1, 20 dogs were randomly assigned to have anesthesia induced and maintained with isoflurane or sevoflurane. The MAC at which each dog awoke in response to auditory stimulation (MACawake-noise) was determined by decreasing the end-tidal concentration by 0.1 volume (vol %) every 15 minutes and delivering a standard audible stimulus at each concentration until the dog awoke. In experiment 2, 12 dogs received the same anesthetic agent they were administered in experiment 1. After duplicate MAC determination, the end-tidal concentration was continually decreased by 10% every 15 minutes until the dog awoke from anesthesia (MACawake). RESULTS: Mean induction time was significantly greater for isoflurane-anesthetized dogs (212 seconds), compared with the sevoflurane-anesthetized dogs (154 seconds). Mean+/-SD MACawake-noise was 1.1+/-0.1 vol % for isoflurane and 2.0+/-0.2 vol % for sevoflurane. Mean MAC was 1.3+/-0.2 vol % for isoflurane and 2.1+/-0.6 vol % for sevoflurane, and mean MACawake was 1.0+/-0.1 vol % for isoflurane and 1.3+/-0.3 vol % for sevoflurane. CONCLUSIONS AND CLINICAL RELEVANCE: Sevoflurane resulted in a more rapid induction than did isoflurane. The MACawake for dogs was higher than values reported for both agents in humans. Care should be taken to ensure that dogs are at an appropriate anesthetic depth to prevent consciousness, particularly when single-agent inhalant anesthesia is used.  相似文献   

10.
OBJECTIVE: To determine the effects of constant rate infusion of morphine, lidocaine, ketamine, and morphine-lidocaine-ketamine (MLK) combination on end-tidal isoflurane concentration (ET-Iso) and minimum alveolar concentration (MAC) in dogs anesthetized with isoflurane and monitor depth of anesthesia by use of the bispectral index (BIS). ANIMALS: 6 adult dogs. PROCEDURE: Each dog was anesthetized with isoflurane on 5 occasions, separated by a minimum of 7 to 10 days. Individual isoflurane MAC values were determined for each dog. Reduction in isoflurane MAC, induced by administration of morphine (3.3 microg/kg/min), lidocaine (50 microg/kg/min), ketamine (10 microg/kg/min), and MLK, was determined. Heart rate, mean arterial blood pressure, oxygen saturation as measured by pulse oximetry (Spo2), core body temperature, and BIS were monitored. RESULTS: Mean +/- SD isoflurane MAC was 1.38 +/- 0.08%. Morphine, lidocaine, ketamine, and MLK significantly lowered isoflurane MAC by 48, 29, 25, and 45%, respectively. The percentage reductions in isoflurane MAC for morphine and MLK were not significantly different but were significantly greater than for lidocaine and ketamine. The Spo2, mean arterial pressure, and core body temperature were not different among groups. Heart rate was significantly decreased at isoflurane MAC during infusion of morphine and MLK. The BIS was inversely related to the ET-Iso and was significantly increased at isoflurane MAC during infusions of morphine and ketamine, compared with isoflurane alone. CONCLUSIONS AND CLINICAL RELEVANCE: Low infusion doses of morphine, lidocaine, ketamine, and MLK decreased isoflurane MAC in dogs and were not associated with adverse hemodynamic effects. The BIS can be used to monitor depth of anesthesia.  相似文献   

11.
OBJECTIVE: To compare the minimum alveolar concentration (MAC) of isoflurane required to prevent corticocerebral activation, autonomic responses, and purposeful movements after somatic or visceral stimulation in cats anesthetized with isoflurane. ANIMALS: 17 healthy spayed female cats. PROCEDURE: Bispectral index (BIS), autonomic parameters, and purposeful movements were monitored before and after somatic or visceral stimuli in cats anesthetized with isoflurane. End-tidal (ET) isoflurane concentration was varied to determine MAC values for cortical arousal (MAC(BIS)), autonomic responsiveness (MAC(BAR)), and purposeful movement (MAC). Bispectral index values > or = 60 were considered to represent corticocerebral activation. RESULTS: Minimum alveolar concentration for purposeful movement was significantly less than MAC(BIS) and MAC(BAR) for both somatic and visceral stimulation. Individual MAC values for somatic stimulation were not significantly different from respective MAC values for visceral stimulation. The percentage of cats that had a BIS response > or = 60 was inversely related to the end-tidal isoflurane concentration. CONCLUSIONS AND CLINICAL RELEVANCE: Corticocerebral arousal and subcortical autonomic reflexes occured at isoflurane anesthetic concentrations at which reflexive or purposeful movements were absent. These results suggested that isoflurane had a preferential effect on voluntary motor output at low end-tidal isoflurane concentrations, and that sensory pathways, subcortical sympathetic output, and cortical responsiveness are less susceptible to the anesthetic effects of isoflurane. Bispectral index values obtained after somatic or visceral stimulation were sensitive for the detection of early changes in cortical excitability.  相似文献   

12.
OBJECTIVE: To compare the anesthetic index of sevoflurane with that of isoflurane in unpremedicated dogs. DESIGN: Randomized complete-block crossover design. ANIMALS: 8 healthy adult dogs. PROCEDURE: Anesthesia was induced by administering sevoflurane or isoflurane through a face mask. Time to intubation was recorded. After induction of anesthesia, minimal alveolar concentration (MAC) was determined with a tail clamp method while dogs were mechanically ventilated. Apneic concentration was determined while dogs were breathing spontaneously by increasing the anesthetic concentration until dogs became apneic. Anesthetic index was calculated as apneic concentration divided by MAC. RESULTS: Anesthetic index of sevoflurane (mean +/- SEM, 3.45 +/- 0.22) was significantly higher than that of isoflurane (2.61 +/- 0.14). No clinically important differences in heart rate; systolic, mean, and diastolic blood pressures; oxygen saturation; and respiratory rate were detected when dogs were anesthetized with sevoflurane versus isoflurane. There was a significant linear trend toward lower values for end-tidal partial pressure of carbon dioxide during anesthesia with sevoflurane, compared with isoflurane, at increasing equipotent anesthetic doses. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that sevoflurane has a higher anesthetic index in dogs than isoflurane. Sevoflurane and isoflurane caused similar dose-related cardiovascular depression, but although both agents caused dose-related respiratory depression, sevoflurane caused less respiratory depression at higher equipotent anesthetic doses.  相似文献   

13.
Duration of anesthesia onset (time to intubation) and recovery (time to extubation, sternal and standing) and quality of recovery were compared for sevoflurane and isoflurane in 10 adult psittacines. Both agents were initially administered at an equal volume percentage (2%) rather than at equal minimum alveolar concentrations (MACs), therefore the initial concentration was above the isoflurane MAC for dogs and birds (1.3%) but below the sevoflurane MAC for dogs (2.3%). The time to intubation was significantly longer with sevoflurane because of initially delivering the sevoflurane below suspected MAC for birds. Although recovery times (time to extubation, sternal, and standing) were not significantly different, birds recovering from sevoflurane were less ataxic. Sevoflurane is a suitable inhalant agent for use in these psittacines and merits further study.  相似文献   

14.
The relationships between bispectral index (BIS), cardiovascular variables and minimum alveolar concentration (MAC) multiples of sevoflurane in puppies were determined. Five puppies were anesthetized with sevoflurane on two occasions. First, the individual sevoflurane MAC values were determined for each puppy. Secondly, dogs were anesthetized with sevoflurane at each of 5 MAC multiples, 0.75, 1, 1.25, 1.5 and 1.75 MAC administered in random order. Hemodynamic parameters and BIS data were collected for 20 min. Somatic stimulus was then applied and the same parameters and data were collected for 6 min. Correlation between BIS and end tidal sevoflurane and between BIS and hemodynamic parameters were studied. We found positive significant correlation in both cases. BIS is lower in puppies that in adults at the same alveolar anesthetic concentrations and sevoflurane appears to be a safe anesthetic in puppies.  相似文献   

15.
The objective of the study was to examine the relationship between the ‘depth’ of anaesthesia - as determined by clinical signs - and the bispectral index (BIS). Electroencephalograms (EEG)s were recorded in 8 female and 8 castrated male, healthy Norwegian landrace pigs undergoing isoflurane anaesthesia, from which the bispectral index (BIS) was calculated. Isoflurane was delivered in pure oxygen at end-tidal concentrations of 1.6, 1.9, 2.2 and 2.5%, in randomised order, for 30 min after which the EEG was recorded over a 5 min period. Anaesthetic depth was evaluated on a visual analogue scale (VAS) by an experienced anaesthetist. The 95% confidence interval for the mean correlation coefficient between BIS and VAS was calculated to be -0.52–0.30. Confidence intervals (95%) for the mean change in the BIS obtained during the conscious state and that obtained during anaesthesia at different isoflurane concentrations was also calculated. There was a significant decrease in the BIS recorded during consciousness and after 1.6% isoflurane anaesthesia, and between readings after inhalation of 2.2% and 2.5% isoflurane. This indicates that BIS does not accurately reflect ‘depth’ at surgical levels of isoflurane anaesthesia in the pig, and is of no use for this purpose.  相似文献   

16.
The effects of noxious surgical stimulation on the electroencephalogram (EEG) in 15 horses anesthetized with isoflurane were evaluated during orthopedic (group 1) and soft tissue (group 2) procedures. The quantitative EEG variables theta/delta ratio (T/D), alpha/delta ratio (A/D), beta/delta ratio (B/D), median power frequency (MED), and 80% spectral edge frequency (SEF 80) recorded during surgeries at 1.7% end-tidal concentration of isoflurane (ETiso) were compared with values from five nonstimulated control horses anesthetized at 1.7% ETiso. The EEG variables T/D, A/D, MED, and SEF 80 from surgically stimulated horses were significantly higher compared with controls. These differences in measured EEG variables were accompanied by a significantly lower relative power in the delta frequency band and a concomitant significantly higher alpha activity. Because the A/D ratio, MED, and SEF 80 in surgically stimulated horses were significantly higher than in nonstimulated control horses these measured EEG variables may provide a valuable tool for identification of nociceptive transmission in isoflurane anesthetized horses.  相似文献   

17.
OBJECTIVE: To evaluate the respiratory effects occurring during administration of sevoflurane or isoflurane to the upper airway in dogs. STUDY DESIGN: A prospective, randomized study. ANIMALS: Twelve healthy adult beagles (6 males, 6 females). METHODS: At least 2 weeks after undergoing permanent tracheostomy, dogs were premedicated with acepromazine-buprenorphine, and anesthesia was induced with thiopental and maintained with alpha-chloralose. The upper airway was functionally isolated so that the inhalant could be administered to the upper airway while dogs were breathing 100% O2 via the tracheostomy. Respiratory reflexes in response to the administration of sevoflurane or isoflurane at concentrations of 1.2, 1.8, and 2.4 times the minimal alveolar concentration (MAC) (administered in 100% O2 at a flow rate of 5 L/min) were recorded. Reflexes in response to administration of each anesthetic were also recorded following upper-airway administration of lidocaine. RESULTS: Respiratory reflexes elicited by upper-airway administration of each anesthetic were characterized by a dose-dependent increase in expiration time, with a resultant decrease in respiratory minute ventilation and increase in end-tidal PCO2. The magnitude of these responses was greater with isoflurane than with sevoflurane at 1.8 and 2.4 MAC. These reflexes were abolished after lidocaine nebulization into the upper airway. CONCLUSION: Isoflurane induces greater reflex inhibition of breathing than does sevoflurane when the anesthetic is inhaled into the upper airway at concentrations used for mask induction.  相似文献   

18.
Objectives To compare the second differential index (SDI) calculated from the auditory evoked potential (AEP) and electroencephalogram (EEG) parameters: median frequency (MF), spectral edge frequency (SEF) and burst suppression rate (BSR) determined at four equivalent minimum alveolar concentrations (MAC) of isoflurane or halothane. Animals Twelve male Wistar rats weighing 418 g (SD ± 18.4 g). Methods Auditory evoked potentials and EEG responses were recorded in animals implanted with electrodes at established anaesthetic concentrations. Depth of anaesthesia was assessed using the strength of the pedal withdrawal reflex (PWR), and data were analysed using repeated measures anova and paired t‐tests. Results The SEF tended to decrease with increasing depth of halothane anaesthesia (F = 4.198, p = 0.05), but not with isoflurane. The MF and SDI were significantly higher during halothane than with isoflurane (F = 5.82, p = 0.036 and F = 5.263, p = 0.045, respectively) at equivalent depths of anaesthesia, and EEG burst suppression occurred at deeper planes of isoflurane but not halothane anaesthesia. Conclusions The study demonstrated that EEG and AEP characteristics recorded at MAC equivalent concentrations were suppressed to a greater degree by isoflurane than by halothane. These findings have strong implications for research projects where EEG recordings are collected, and also cast more general doubts upon the value of such parameters for evaluating depth of isoflurane anaesthesia in rats.  相似文献   

19.
OBJECTIVE: To determine the relationship between bispectral index (BIS) and minimum alveolar concentration (MAC) multiples of isoflurane after IM injection of medetomidine or saline (0.9% NaCl) solution in anesthetized dogs. ANIMALS: 6 dogs. PROCEDURE: Each dog was anesthetized 3 times with isoflurane. First, the MAC of isoflurane for each dog was determined by use of the tail clamp method. Second, anesthetized dogs were randomly assigned to receive an IM injection of medetomidine (8 microg x kg(-1)) or an equal volume of isotonic saline (0.9% NaCl) solution 30 minutes prior to beginning BIS measurements. Last, anesthetized dogs received the remaining treatment (medetomidine or isotonic saline solution). Dogs were anesthetized at each of 4 MAC multiples of isoflurane. Ventilation was controlled and atracurium (0.2 mg/kg followed by 6 microg/kg/min as a continuous infusion, IV) administered. After a 20-minute equilibration period at each MAC multiple of isoflurane, BIS data were collected for 5 minutes and median values of BIS calculated. RESULTS: BIS significantly decreased with increasing MAC multiples of isoflurane over the range of 0.8 to 2.0 MAC. Mean (+/- SD) MAC of isoflurane was 1.3 +/- 0.2%. During isoflurane-saline anesthesia, mean BIS measurements at 0.8, 1.0, 1.5, and 2.0 MAC were 65 +/- 8, 60 +/- 7 52 +/- 3, and 31 +/- 28, respectively. During isoflurane-medetomidine anesthesia, mean BIS measurements at 0.8, 1.0, 1.5, and 2.0 MAC were 77 +/- 4, 53 +/- 7, 31 +/- 24, and 9 +/- 20, respectively. CONCLUSIONS AND CLINICAL RELEVANCE: BIS monitoring in dogs anesthetized with isoflurane has a predictive value in regard to degree of CNS depression. During isoflurane anesthesia, our results support a MAC-reducing effect of medetomidine.  相似文献   

20.
OBJECTIVE: To evaluate the correlation between the bispectral index (BIS) and end-tidal isoflurane (ET(ISO)) concentration and compare the use of 3 BIS sensor positions in dogs. ANIMALS: 6 adult dogs. PROCEDURES: Mechanically ventilated dogs received pancuronium, and depth of anesthesia was altered by increasing ET(ISO) concentration from 1.5% to 2.3% and 3.0%. The BIS, suppression ratio (relative percentage of isoelectric electroencephalographic waveforms), and signal quality index (SQI) were recorded at each ET(ISO) concentration for each of 3 BIS sensor positions (frontal-occipital, bifrontal, and frontal-temporal positions). RESULTS: The BIS and ET(ISO) concentration were poorly correlated; regardless of sensor positioning, mean BIS values did not change significantly as ET(ISO) was increased. At 3% isoflurane, regardless of sensor positioning, there was an increase in suppression ratio coincident with BIS < 40 in some dogs, whereas paradoxic increases in BIS (> 60) were recorded in others. Furthermore, at 3.0% isoflurane, the SQI was significantly lower for the bifrontal sensor position (compared with values for the other positions), but low SQI values prevented recording of BIS values from the frontal-occipital sensor position in 2 dogs. Overall, BIS values derived from the 3 sensor positions did not differ. CONCLUSIONS AND CLINICAL RELEVANCE: In dogs, BIS values may not reflect changes in depth of isoflurane anesthesia in the absence of noxious stimulation. Of the 3 sensor positions, frontal-temporal positioning provided better correlation with changes in depth of anesthesia induced via changes in isoflurane concentrations. However, the sensor placements yielded similar results at SQI values > 50.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号