OBJECTIVE: To compare screw insertion variables and pullout mechanical properties between AO 6.5-mm cancellous and 7.3-mm cannulated bone screws in foal femoral bone. STUDY DESIGN: A paired, in vitro mechanical study. SAMPLE POPULATION: Seven pairs of femora from immature (1-7 months) foals. METHODS: The 6.5 cancellous and 7.3-mm cannulated screws were inserted at standardized proximal and distal metaphyseal, and mid-diaphyseal locations. Insertion torque, force, and time to drill, tap (6.5-mm cancellous), guide wire insertion (7.3-mm cannulated), and screw insertion were measured. Screw pullout properties (yield and failure load, displacement, and energy, and stiffness) were determined from mechanical tests. The effects of screw type and location on insertion variables and pullout properties were assessed with repeated measures ANOVA. Pairwise comparisons were examined with post hoc contrasts. Significance was set at P<.05 for all comparisons. RESULTS: Insertion torques for the 7.3-mm cannulated screws were significantly greater than for the 6.5-mm tap, but significantly lower than for the 6.5-mm cancellous screws. Total screw insertion times were similar. Pullout properties of both screws were similar at each femoral location. The holding power of both screws was significantly greater in the mid-diaphysis than in either metaphyseal location. Pullout failure occurred by bone shearing at the bone-screw interface in all specimens. CONCLUSIONS: The 6.5-mm cancellous and 7.3-mm cannulated screws vary in insertion properties, but have similar pullout properties in the mid-diaphysis, proximal, and distal metaphysis of foal femora. Both screw types have greater holding power at the mid-diaphyseal location compared with metaphyseal locations. Based on overall similar holding powers of 6.5-mm cancellous and 7.3-mm cannulated screws, it is unlikely that increasing the screw diameter beyond 6.5 mm will provide increased holding power in foal femoral bone. CLINICAL RELEVANCE: Use of the 7.3-mm cannulated screw should be considered for foal femoral fracture repair when greater accuracy is needed, or when bone threads for the 6.5-mm cancellous screw have been stripped.  相似文献   

2.
OBJECTIVE: To compare screw insertion characteristics and pullout mechanical properties between self-tapping (ST) and non-self-tapping (NST) AO 4.5-mm cortical bone screws in adult equine third metacarpal bone (MC3). STUDY DESIGN: In vitro biomechanical experiment. ANIMALS OR SAMPLE POPULATION: Seven pairs of adult equine MC3. METHODS: Bicortical holes were drilled transversely in proximal metaphyseal, diaphyseal, and distal metaphyseal locations of paired MC3. NST screws were inserted in pre-tapped holes in 3 sites of one bone pair, and ST screws were inserted in non-tapped holes of contralateral MC3. Tapping and screw insertion times and maximum torques were measured. Screw pullout mechanical properties were determined. RESULTS: Screw insertion time was longer for ST screws. Total time for tapping and insertion (total insertion time) was over twice as long for NST screws. Statistically significant differences were not observed between screws for any pullout mechanical property. From pullout tests, diaphyseal locations had significantly stiffer and stronger structure than metaphyseal locations. Pullout failure more commonly occurred because of screw breakage than bone failure. Bone failure and bone comminution were more commonly associated with ST screws. Bone failure sites had pullout failure loads that were 90% of screw failure sites. CONCLUSIONS: NST and ST 4.5-mm-diameter cortical bone screws have similar pullout mechanical properties from adult equine MC3. ST screws require less than half the total insertion time of NST screws. CLINICAL RELEVANCE: Use of ST 4.5-mm-diameter cortical bone screws should be considered for repair of adult equine MC3 fractures; however, bone failures at screw sites should be monitored.  相似文献   

3.
Objective—To assess feasibility of insertion of 4.5-mm Herbert cannulated bone screws (HS) using fluoroscopic guidance and compare the mechanical shear strength of these HS and 4.5-mm AO cortical bone screws (AO) for fixation of dorsal plane slab osteotomies in equine cadaver third carpal bones (C3).
Animals or Sample Population—Eight equine cadavers.
Methods—Bone mineral composition and density of contralateral C3 were confirmed to be equivalent using dual-energy x-ray absorptiometry. A standard 10-mm C3 slab osteotomy was reduced using HS or AO instrumentation under fluoroscopic guidance. Specimens were loaded in shear until failure, using a materials testing apparatus.
Results—HS and AO instrumentation allowed accurate reconstruction of the osteotomy, but there was difficulty encountered seating the HS proximal self-tapping threads. There was no significant difference in maximal load to failure, stiffness, or mode of failure of constructs created with the HS and AO screws.
Conclusions —Use of 4.5-mm HS for repair of C3 radial facet, dorsal plane slab fractures may result in a mechanically comparable fixation to a repair using a 4.5-mm AO. Equine dorsal C3 may be too dense, however, to allow placement of the proximal self-tapping threads of the HS without potentially excessive application of torque to the screw itself.
Clinical Relevance —Dorsal plane, radial facet slab fractures of the equine C3 are a significant clinical problem. Accurate reconstruction and stabilization are necessary for return to athletic function.  相似文献   

4.
OBJECTIVES--To compare the pullout properties of 3.5-mm AO/ASIF self-tapping screws (STS) to corresponding standard cortex screws (CS) in a uniform synthetic test material and in canine femoral bone. The influence of screw-insertion technique, test material, and test-material thickness were also assessed. STUDY DESIGN--In vitro experimental study. SAMPLE POPULATION--Two independent studies: a uniform synthetic test material and paired femurs from mature dogs. METHODS-Mechanical testing was performed in accordance with standards established by the American Society for Testing and Materials for determination of axial pullout strength of medical bone screws. Completely inserted STS, completely inserted CS, and incompletely inserted STS were tested in 3 groups of 10 test specimens each in 4.96-mm and 6.8-mm thick sheets of synthetic material. In the bone study, group 1 consisted of 24 completely inserted STS compared with 24 completely inserted CS, and group 2 consisted of 24 incompletely inserted STS versus 24 completely inserted CS. Comparisons were made between paired femurs at corresponding insertion sites. Pullout data were normalized, thereby eliminating the effect of test-material thickness on pullout properties. Mean values were compared using 2-way ANOVA. Statistical significance was set at P <.05. RESULTS--In both the 4.96-mm and 6.8-mm synthetic material, pullout testing of the completely inserted STS demonstrated significantly greater yield strength and ultimate strength than completely inserted CS. There was no significant difference between incompletely inserted STS and completely inserted STS. The 6.8-mm test material significantly increased yield strength and ultimate strength for all test groups compared with the 4.96-mm test material. In canine bone, there was no significant difference in yield strength of completely inserted STS and completely inserted CS. Yield strength of completely inserted STS and completely inserted CS were significantly greater than incompletely inserted STS. CONCLUSIONS--Pullout properties of completely inserted STS were significantly greater than corresponding CS in a uniform test material. In canine bone, the pullout strength of STS and CS were not different. Incomplete STS insertion resulted in an 18% reduction in holding power as compared with completely inserted CS and STS in canine bone. CLINICAL RELEVANCE--The length of STS used in canine bone should be such that the cutting flutes extend beyond the trans cortex to maximize pullout strength.  相似文献   

5.
Objective—To determine and compare the in vitro pullout strength of 5.5-mm cortical versus 6.5-mm cancellous bone screws inserted in the diaphysis and metaphysis of adult equine third metacarpal (MCIII) bones, in threaded 4.5-mm cortical bone screw insertion holes that were then overdrilled with a 4.5-mm drill bit to provide information relevant to the selection of a replacement screw if a 4.5-mm cortical screw is stripped. Study Design—In vitro pullout tests of 5.5-mm cortical and 6.5-mm cancellous screws in equine MCIII bones. Sample Population—Two independent cadaver studies each consisting of 14 adult equine MCIII bones. Methods—Two 4.5-mm cortical screws were placed either in the middiaphysis (study 1) or distal metaphysis (study 2) of MCIII bones. The holes were then overdrilled with a 4.5-mm drill bit and had either a 5.5-mm cortical or a 6.5-mm cancellous screw inserted; screw pullout tests were performed at a rate of 0.04 mm/second until screw or bone failure occurred. Results—In diaphyseal bone, the screws failed in all tests. Tensile breaking strength for 5.5-mm cortical screws (997.5 ± 49.3 kg) and 6.5-mm cancellous screws (931.6 ± 19.5 kg) was not significantly different. In metaphyseal bone, the bone failed in all tests. The holding power for 6.5-mm cancellous screws (39.1 ± 4.9 kg/mm) was significantly greater than 5.5-mm cortical screws (23.5 ± 3.5 kg/mm) in the metaphysis. There was no difference in the tensile breaking strength of screws in the diaphysis between proximal and distal screw holes; however, the holding power was significantly greater in the distal, compared with the proximal, metaphyseal holes. Conclusions—Although tensile breaking strength was not different between 5.5-mm cortical and 6.5-mm cancellous screws in middiaphyseal cortical bone, holding power of 6.5-mm cancellous screws was greater than 5.5-mm cortical screws in metaphyseal bone of adult horses. Clinical Relevance—If a 4.5-mm cortical bone screw strips in MCIII diaphyseal bone of adult horses, either a 5.5-mm cortical or 6.5-mm cancellous screw, however, would have equivalent pullout strengths. A 6.5-mm cancellous screw, however, would provide greater holding power than a 5.5-mm cortical screw in metaphyseal bone.  相似文献   

6.
Objective —To measure pullout strength of four pin types in avian humeri and tibiotarsi bones and to compare slow-speed power and hand insertion methods.
Study Design —Axial pin extraction was measured in vitro in avian bones.
Animal Population —Four cadaver red-tailed hawks and 12 live red-tailed hawks.
Methods —The pullout strength of four fixator pin designs was measured: smooth, negative profile threaded pins engaging one or two cortices and positive profile threaded pins. Part 1: Pins were placed in humeri and tibiotarsi after soft tissue removal. Part 2: Pins were placed in tibiotarsi in anesthetized hawks using slow-speed power or hand insertion.
Results —All threaded pins, regardless of pin design, had greater pullout strength than smooth pins in all parts of the study ( P < .0001). The cortices of tibiotarsi were thicker than the cortices of humeri ( P < .0001). There were few differences in pin pullout strengths between threaded pin types within or between bone groups. There were no differences between the pullout strength of pins placed by slow-speed power or by hand.
Conclusions —There is little advantage of one threaded pin type over another in avian humeri and tibiotarsi using currently available pin designs. There were few differences in pin pullout strengths between humeri and tibiotarsi bones. It is possible that the ease of hand insertion in thin cortices minimizes the potential for wobbling and therefore minimizes the difference between slow-speed drill and hand insertion methods.
Clinical Relevance —Threaded pins have superior bone holding strength in avian cortices and may be beneficial for use with external fixation devices in birds.  相似文献   

7.
OBJECTIVES: To compare bone fragment compression and the mechanical pushout strength and stiffness of 6.5-mm Acutrak Plus (AP) and 4.5-mm AO cortical (AO) bone screws after stabilization of a simulated equine third metacarpal (MC3) bone complete lateral condylar fracture. STUDY DESIGN: In vitro biomechanical paired study of screw insertion variables, bone fragment compression, and screw pushout tests using a bone screw stabilized simulated lateral condylar fracture model. SAMPLE POPULATION: Six pairs of cadaveric equine MC3s. METHODS: Metacarpi were placed in a fixture and centered on a biaxial load cell in a materials testing system to measure torque, compressive force, and time for drilling, tapping, and screw insertion. Fragment compression was measured with a pressure-sensing device placed between the simulated fracture fragments during screw insertion for fragment stabilization. Subsequently, screws were pushed out of the stabilized bone fragments in a single cycle to failure. A paired t test was used to assess differences between site preparation, screw insertion, fragment compression, and screw pushout variables, with significance set at P <.05. RESULTS: Measured drilling variables were comparable for AO and AP specimens. However, the AP tap had significantly greater insertion torque and force. Mean maximum screw insertion torque was significantly greater for AO screws. For fragment compression, AP screws generated 65% and 44% of the compressive pressure and force, respectively, of AO screws. AP screws tended to have higher overall pushout strength. Pushout stiffness was similar between both screw types. CONCLUSION: The 6.5-mm tapered AP screw generated less interfragmentary compressive pressure and force but had similar pushout stiffness. Evaluation of failure patterns demonstrated that AP screws had greater pushout strength compared with 4.5-mm AO screws for fixation of a simulated complete lateral condylar fracture. CLINICAL RELEVANCE: The 6.5-mm tapered AP screw should provide ample holding strength but would provide less interfragmentary compression than 4.5-mm AO screws for repair of complete lateral condylar fractures in horses.  相似文献   

8.
OBJECTIVE: To compare acute fixation stability and insertion effort of cortex bone screws with and without a shaft inserted in lag fashion in equine metacarpal (metatarsal, MC(T)III) bone. METHODS: Screw types with independent variables of screw diameter (4.5 or 5.5 mm) and shaft type (without shaft, with 20-mm shaft, or with 25-mm shaft) were studied. Bone specimens cut from distal equine MC(T)III condyles were used. After screw insertion in lag fashion into 2 bone blocks with an instrumented device, shear tests were conducted in a mechanical testing machine. Outcome variables of peak insertion torque, insertion energy, stiffness. yield strength, and displacement at 3 kN of load were compared. RESULTS: The effects of screw design were substantial. Screws with shaft were 30% to 40% stiffer and 60% to 70% stronger than screws without shaft. Screws with shaft could tolerate 80 to 95 kg more force than screws without shaft before yielding. At 3 kN load, the displacement with screws with shaft was 55% to 60% of that with screws without shaft. Screws with a long shaft tended to perform better than those with a short shaft. There was no difference in the shear stiffness, shear yield strength, or shear displacement between the 2 screw diameters. Although larger diameter screws required more insertion effort, and screws with a short shaft required the most insertion energy, these differences were small. CONCLUSIONS: Cortex screws with a long shaft of 4.5- or 5.5-mm diameter provide better stability in equine MC(T)III condyle bone with less insertion effort compared with those with a short shaft or no shaft. CLINICAL SIGNIFICANCE: Cortex bone screws with a shaft inserted in lag fashion should be considered for the fixation of equine MC(T)III condylar fractures.  相似文献   

9.
The holding power of orthopedic screws in the third metacarpal and metatarsal cadaver bones of foals that were aged from 1 to 14 days was tested. Comparative trials between screws inserted at the same site in contralateral bones from the same foal were performed to compare the holding power of 5.5 mm cortical and 6.5 mm cancellous screws in the metaphysis, and the holding power of 5.5 and 4.5 mm cortical screws in the diaphysis. A MTS servohydraulic tensile testing machine was used to perform screw pullouts at a displacement rate of 19 mm/sec. There was no significant difference between maximum holding power of 5.5 mm cortical screws and 6.5 mm cancellous screws in the metaphysis when expressed as kg per mm of bone width at the screw insertion site (p = 0.097) or as kg per mm of screw thread engaged in the bone (p = 0.17). There was no significant difference in holding power of 5.5 and 6.5 mm screws in the proximal versus distal metaphysis (p = 0.10). The 5.5 mm screws had significantly greater holding power than the 4.5 mm screws in the diaphysis (p = 0.0097). Fixation failure at screw pullout was always due to bone shear. In internal fixation in foal bone, the 5.5 mm screws may be a suitable alternative to 6.5 mm screws in the metaphysis. Use of 5.5 mm rather than 4.5 mm screws is recommended in the diaphysis because of greater holding power.  相似文献   

10.
OBJECTIVE: To compare variables for screw insertion, pushout strength, and failure modes for a headless tapered compression screw inserted in standard and oversize holes in a simulated lateral condylar fracture model. SAMPLE POPULATION: 6 pairs of third metacarpal bones from horse cadavers. PROCEDURE: Simulated lateral condylar fractures were created, reduced, and stabilized with a headless tapered compression screw by use of a standard or oversize hole. Torque, work, and time for drilling, tapping, and screw insertion were measured during site preparation and screw implantation. Axial load and displacement were measured during screw pushout. Effects of drill hole size on variables for screw insertion and screw pushout were assessed by use of Wilcoxon tests. RESULTS: Drill time was 59% greater for oversize holes than for standard holes. Variables for tapping (mean maximum torque, total work, positive work, and time) were 42%, 70%, 73%, and 58% less, respectively, for oversize holes, compared with standard holes. Variables for screw pushout testing (mean yield load, failure load, failure displacement, and failure energy) were 40%, 40%, 47%, and 71% less, respectively, for oversize holes, compared with standard holes. Screws could not be completely inserted in 1 standard and 2 oversize holes. CONCLUSIONS AND CLINICAL RELEVANCE: Enlarging the diameter of the drill hole facilitated tapping but decreased overall holding strength of screws. Therefore, holes with a standard diameter are recommended for implantation of variable pitch screws whenever possible. During implantation, care should be taken to ensure that screw threads follow tapped bone threads.  相似文献   

11.
Seven-hole 3.5 mm broad and 5-hole 4.5 mm narrow dynamic compression plates were applied to paired canine cadaveric tibias in a stable fracture model. Paired tibias were tested to acute failure in rotation and four-point bending, and to fatigue failure in four-point bending. Resistance to screw pullout was measured for three 3.5 mm cortical screws and two 4.5 mm cortical screws inserted in the configurations of the bone plates. All plate-bone systems failed by fracture of the bone through a screw hole. The 3.5 mm plate-bone system was stronger in acute failure in rotation and in four-point bending. There was no difference in stiffness, and no difference in the number of cycles to failure in fatigue testing. Three 3.5 mm screws had greater resistance to pullout than two 4.5 mm screws. Results indicate that the 7-hole 3.5 mm broad dynamic compression plate has a biomechanical advantage over the 5-hole 4.5 mm narrow dynamic compression plate.  相似文献   

12.
Comparison was made of the holding power of 5.5 and 4.5 mm cortical orthopedic screws inserted into third metacarpal and metatarsal cadaver bones from 3- and 8-year-old horses. The tensile strength of these screws was tested mechanically. In nine comparative trials of these screws, 5.5 mm screws pulled out of bone in five trials at an average of 116.0 kg tensile force and broke in four trials at an average of 1383.2 kg. A 4.5 mm screw pulled out of bone at 834.5 kg in one trial, and screws broke at an average of 849.2 kg in eight trials. The larger 5.5 mm screw required a significantly greater (p = 0.022) pullout force than the mean force at 4.5 mm screw breakage. Fixation failure was due to screw breakage or bone shear, with 5.5 mm screws occasionally creating bone fragmentation during pullout. The average tensile breaking strengths of the 5.5 mm screws (1391.4 kg) and 4.5 mm screws (832.7 kg) determined mechanically were similar to forces at screw breakage during pullout testing in bone. Since the 5.5 mm screws have greater holding power and tensile strength than 4.5 mm screws, the use of the 5.5 mm screw in fracture repair in adult horses is recommended.  相似文献   

13.
Lag screw fixation using single 4.5 mm cortical bone screws is a recommended technique for repair of mid-sagittal plane fractures of the distal phalanx in adult horses. However, implant infection and technical difficulties in obtaining adequate interfragmentary compression have made this surgical procedure somewhat controversial. We hypothesized that use of larger diameter screws would result in increased axial compression and improved stability of this fracture.Paired distal phalanges from the forelimbs of 10 adult horses were collected at necropsy and divided in half in the midsagittal plane. Using a randomized block study design, four types of bone screws (4.5 mm cortical, 5.5 mm cortical, 6.5 mm cancellous pre-tapped, and 6.5 mm cancellous non-tapped) were inserted to a depth of 15 mm. During screw insertion, the axial force generated under the screw head was measured with a load washer containing a piezoelectric force transducer, while torque of insertion was recorded with a torsional testing machine. The 6.5mm screw inserted after pre-tapping generated significantly greater axial force (2781 N) than the 4.5 mm (1522 N), 5.5 mm (2073 N) or 6.5 mm non-tapped (2295 N) screws. The relationship between maximal applied torque and axial force generated was linear for each screw type. Each unit of torque applied during insertion of cortical screws resulted in a greater increase in axial compression, as compared to cancellous screws. These data suggest that use of larger diameter screws would result in improved interfragmentary compression of distal phalangeal fractures.  相似文献   

14.
OBJECTIVE: To evaluate the effect of 2 cement augmentation techniques on pullout strength of 1.5 mm screws placed in stripped 1.5 mm screw sites in the distal metaphysis of feline radii. STUDY DESIGN: Experimental study. SAMPLE POPULATION: Feline radii (21 pairs). METHODS: Treatment groups (n=4) were allocated according to a Latin square design to 4 sites in each pair of radii. Positive and negative controls were a 1.5 mm screw and a screw of the same diameter in a previously stripped screw hole, respectively. Treatment groups were a 1.5 mm screw implanted in a previously stripped screw hole after injection of polymethylmethacrylate (PMMA) or a bioresorbable calcium phosphate cement (CPC, Norian skeletal repair system (SRS)). The ultimate pullout strength was compared between groups. RESULTS: The mean (+/-SEM) pullout strength of screws augmented with either bone cement was less than that of the positive control group and greater than that of the negative control. Injection of CPC or PMMA before screw implantation increased the pullout strength of the negative control by 86.8+/-22.9% and 104.1+/-32.1%, respectively. Holding power of the positive control screws differed from these 2 groups, and was 274.8+/-39.17% higher than that of the negative control. CONCLUSION: Injection of CPC or PMMA increases but does not restore the holding power of stripped 1.5 mm diameter screws. CLINICAL RELEVANCE: The use of CPC (Norian SRS) augmentation of stripped 1.5 mm diameter screws warrants clinical investigation as it combines biomechanical results similar to PMMA with osteoconduction and resorbability.  相似文献   

15.
Four pairs of ASIF MP35N stainless steel screws, one conventional smooth surfaced and one that had its surface modified by texturing with an ion-beam, were inserted in the third metacarpus of six horses. The pairs of screws were placed from dorsal to palmar in the metaphyses and diaphysis of the bone using the lag-screw principle. When the screws were examined at 90 and 150 days after insertion, micromovement was detected histologically but not radiographically around the screw in the dorsal cortex but not the palmar cortex. The removal torque of all screws 90 days after insertion was reduced compared to the insertion torque, and no difference was found between the rough and smooth screws. At 150 days after insertion, the removal torque of the smooth screws remained low, but the removal torque of the rough screws was increased significantly (p < 0.001). The removal torque of both smooth and rough screws was significantly higher in the diaphysis than in the metaphysis (p < 0.02). Since the need for a screw's holding ability is greatest early after fracture repair, it is doubtful that ion-beam textured screws have any advantage over smooth screws in the repair of metacarpal fractures. The response of the dorsal and palmar cortices indicated that the equine metacarpus undergoes bending during loading and that the dorsal and palmar cortices of the bone move relative to each other.  相似文献   

16.
OBJECTIVE: To evaluate the effect of an osteoconductive resorbable calcium phosphate cement (CPC) on the holding power of bone screws in canine pelvises and to compare the effect with that for polymethylmethacrylate (PMMA). SAMPLE POPULATION: 35 pelvises obtained from canine cadavers. PROCEDURE: Each pelvis was sectioned longitudinally. Within each pair of hemipelvises, one 4.0-mm cancellous screw was placed in the sacroiliac (SI) region and another in the iliac body. Similar regions on the contralateral-matched hemipelvis were assigned 1 of 3 augmentation techniques (CPC-augmented 4.0-mm cancellous screws, PMMA-augmented 4.0-mm cancellous screws, and CPC-augmented 3.5-mm cortical screws). Pullout force was compared between matched screws and between treatment groups prior to examination of cross sections for evaluation of cement filling and noncortical bone-to-cortical bone ratio. RESULTS: CPC and PMMA augmentation significantly increased pullout force of 4.0-mm screws inserted in the SI region by 19.5% and 33.2%, respectively, and CPC augmentation significantly increased pullout force of 4.0-mm cancellous screws inserted in the iliac body by 21.2%. There was no difference in the mean percentage augmentation between treatment groups at either location. Cement filling was superior in noncortical bone, compared with filling for cortical bone. Noncortical bone-to-cortical bone ratio was significantly greater in the sacrum (6.1:1) than the ilium (1.3:1). CONCLUSIONS AND CLINICAL RELEVANCE: CPC and PMMA improve the ex vivo holding strength of 4.0-mm cancellous screws in the SI and iliac body regions and SI region, respectively. Cement augmentation may be more effective in areas with greater noncortical bone-to-cortical bone ratios.  相似文献   

17.
Objective— To compare locking screws with conventional screws inserted in the tibial plateau fragment for reduction and stability of the construct after tibial plateau leveling osteotomy (TPLO), using a locking TPLO plate.
Study Design— Experimental biomechanical study.
Animals— Cadaveric canine pelvic limbs (n=8 pairs).
Methods— TPLO was stabilized with either conventional cortical screws or locking screws in a compressed osteotomy model. Titanium pins inserted into the tibial plateau and proximal metaphysis were used to track bone fragment location by computed tomography (CT) imaging. CT imaging was performed after osteotomy reduction, after plate stabilization, and after 30,000 cycles of axial compression testing. After 30,000 cycles, cyclic loading was continued with monotonically increasing peak-load until failure.
Results— The magnitude of rotation about the sawing axis was significantly greater for the conventional screw group because of plate application ( P =.009). Translational movement of the tibial plateau fragment toward the plate was significantly greater for the conventional screw group ( P =.006). There were no significant differences between groups in stiffness or number of cycles to failure.
Conclusion— Maintenance of tibial plateau position was significantly superior for the locking screw group during plate application; however, screw type had no effect on fixation stability under cyclic loading.
Clinical Relevance— These results suggest that conventional screws and careful contouring of the TPLO plate can provide comparable mechanical stability to fixation with locking screws in the tibial plateau under load-sharing conditions, but potentially at the expense of osteotomy reduction.  相似文献   

18.
Objective — To determine the monotonic mechanical properties of osteotomized adult equine tibiae stabilized with two dynamic compression plates (DCP) and to compare the mechanical properties with those of intact tibiae and in vivo loads.
Study Design — The compressive, bending, and torsional mechanical properties of plated and intact tibiae were assessed in vitro.
Animals or Sample Population — Twelve pairs of adult equine tibiae.
Methods — Tibiae were loaded in axial compression, craniocaudal 3-point bending, or torsion in external rotation in a single cycle to failure. Mechanical properties were determined from load-displacement data.
Results — Compared to intact tibiae, the mean yield load, failure load and stiffness of plated tibiae were significantly lower ( P <.05) (compression and torsion); and the mean yield and failure bending moments, and bending stiffness, of the plated tibiae were lower ( P <.075 for yield), or significantly lower, respectively. The mean compression and bending yield loads for plated tibiae were greater than in vivo loads. The mean torsional yield load for plated tibiae approximated the torsional load determined for the adult horse at a walk.
Conclusions — Simple, anatomically reduced, DCP plated tibiae should have adequate strength to withstand immediate, postoperative in vivo compressive loads and bending moments placed on the tibia in vivo during immediate postoperative activities, however, may not have adequate torsional strength during immediate postoperative weight-bearing at a walk.
Clinical Relevance — Additional supportive methods, to decrease torsional loads, may be beneficial in maintaining stability of plate repaired tibiae during recovery from anesthesia and postoperative healing.  相似文献   

19.
OBJECTIVE: To compare drilling, tapping, and screw-insertion torque, force, and time for the 4.5-mm AO and 6.5-mm Acutrak Plus (AP) bone screws, and to compare the mechanical shear strength and stiffness of a simulated complete lateral condylar fracture of the equine third metacarpal bone (MC3) stabilized with either an AO or AP screw. STUDY DESIGN: In vitro biomechanical assessment of screw-insertion variables, and shear failure tests of a bone-screw-stabilized simulated lateral condylar fracture. SAMPLE POPULATION: Eight pairs of cadaveric equine MC3s METHODS: Metacarpi were placed in a fixture and centered on a biaxial load cell in a materials-testing system to measure torque, compressive force, and time for drilling, tapping, and screw insertion. Standardized simulated lateral condylar fractures were stabilized by either an AO or AP screw and tested in shear until failure. A paired t test was used to assess differences between screws, with significance set at P < .05. RESULTS: Insertion and mechanical shear testing variables were comparable for AO and AP insertion equipment and screws. CONCLUSION: The 6.5-mm tapered AP screw can be inserted in equine third metacarpal condyles and is mechanically comparable with the 4.5-mm AO screw for fixation of a simulated lateral condylar fracture. CLINICAL RELEVANCE: Considering the comparable mechanical behavior, the potential for less-persistent soft-tissue irritation with the headless design, and the ability to achieve interfragmentary compression by inserting the screw in one hole drilled perpendicular to the fracture plane, the 6.5-mm tapered AP screw may be an attractive alternative for repair of incomplete lateral condylar fractures in horses.  相似文献   

20.
Objective —To describe incomplete oblique sagittal dorsal cortical fractures of the equine third metacarpal bone, their surgical repair, and subsequent performance of the horses.
Study Design —Retrospective examination of medical records and racing performance.
Animal Population —Six Thoroughbred race horses, 2 to 4 years of age.
Methods —Radiographic confirmation of all fractures preceded general anesthesia and surgical correction. Three fractures were treated by intracortical compression using screws placed in lag fashion, and five fractures were treated by osteostixis. Race records were reviewed for each horse to determine performance after surgery.
Results —Fractures were best observed on palmarodorsal radiographic projections. Three horses treated by intracortical compression returned to racing, but fracture recurred in one horse and was treated by osteostixis. This horse and the other three horses treated by osteostixis raced after surgery.
Conclusions —Horses with incomplete oblique sagittal fractures of the dorsal cortex of the third metacarpal bone can race after surgical management of the fracture by screws placed in lag fashion or osteostixis. The authors' preferred surgical procedure for managing this fracture is osteostixis.
Clinical Relevance —Palmarodorsal radiographic projections of the third metacarpal bone are recommended in young Thoroughbred race horses suspected of having dorsal metacarpal stress fractures.  相似文献   