首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
A high-performance liquid chromatographic method with an evaporative light scattering detector (HPLC-ELSD) was developed to simultaneously determine 10 steroidal saponins, including 3 furostanol glycosides, 3 pennogenyl glycosides, and 4 diosgenyl glycosides in Taiwanese rhizoma paridis ( Paris formosana Hayata). The condition was a Cosmosil C18 column kept at 35 °C and a step-gradient solvent system consisting of acetonitrile and water (25:75, v/v) in the first 30 min, 45:55 (v/v) from 31 to 45 min, and 50:50 (v/v) from 45 to 65 min, at a flow rate of 1 mL/min. The separation factors (α) and resolutions (Rs) were better than 1, and the limits of detection (LODs) and limits of quantification (LOQs) were 0.01-0.27 and 0.04-0.90 μg, respectively, for these saponins. Moreover, 203 nm UV detection was also used for comparison. The saponins in P. formosana Hayata gathered from various areas of Taiwan were determined by applying the established method.  相似文献   

2.
A simple and highly sensitive reversed-phase high-performance liquid chromatographic method (RP-HPLC) has been developed for the determination of steviol (SV) using dihydroisosteviol (DHISV) as an internal standard (IS). SV and DHISV were derivatized by reaction of the acids with 4-(bromomethyl)-7-methoxycoumarin in an aprotic solvent (DMF or acetone). The resulting ester derivatives were separated on an ODS column (250 x 4.6 mm i.d., 5 microm particle size) using fluorescence detection with excitation at 321 nm and emission at 391 nm. The mobile phase consisted of acetonitrile/water (80:20 v/v) with a flow rate of 1 mL min(-)(1). A linear relationship was observed for concentrations between 0.5 and 50 microg/mL of SV, and the detection limit was 100 pg. For application of this method to samples of beer fortified with stevioside, a simple procedure for extraction of the beer with diethyl ether and derivatization in DMF was applied. Whereas beer samples spiked with SV gave a linear response over the range 0.1-15 microg/mL beer, no SV could be detected in beer samples enriched in stevioside that had been stored for over 3 years. The application of the method to plant samples involved preparation of an acid fraction containing the SV analyte, derivatization, and sample cleanup using small silica columns and thin-layer chromatography. A sensitive determination of 594 ng of steviol present in 100 mg of dry plant material was performed with high precision and accuracy.  相似文献   

3.
The objective of this research was to develop a novel high-performance liquid chromatographic (HPLC) method involving a simple sample preparation procedure for the rapid, low-cost, and sensitive quantitation of phenol in honey at levels of regulatory and practical importance. After proper dilution of honey with water, the samples were analyzed by a gradient HPLC system, using a reversed-phase column with fluorescence detection at excitation and emission wavelengths of 270 and 300 nm, respectively. The eluents applied were water-acetonitrile-85% orthophosphoric acid (10:10:0.01, v/v/v) and water-85% orthophosphoric acid (20:0.01, v/v). The retention time of phenol was found to be 14.1 min, and the limit of quantitation for phenol in honey was set at 5 microg/kg. Overall recovery was 98%. The proposed method has been successfully applied to real sample analysis.  相似文献   

4.
A simple, rapid, and sensitive high-performance liquid chromatography (HPLC) method was developed and validated for identification and determination of flavonoids in Convolvulus pilosellifolius. The chromatographic separation was achieved in less than 6 min using C18 column (150 × 4.6 mm, 3 μm) with isocratic mixture of methanol and water containing 0.1 percent v/v formic acid in the ration of 80:20 at 258 nm with a flow rate of 0.4 mL/min. The method was validated in the linear calibration curve ranged between 1 and 300 μg/mL with detection limits of 0.39 and 0.26 μg/mL and quantification limits of 1.20 and 0.79 μg/mL for quercetin and kaempferol, respectively. Good repeatability of the method were achieved at percent relative standard deviation (RSD < 2.18 percent) with respect to inter- and intraday repeatability. Recovery values were found to be in the range of 98.2–100.2 percent, indicating high accuracy of the method. The maximum flavonoid contents were 1.07 and 1.54 percent for quercetin and kaempferol, respectively.  相似文献   

5.
An analytical method has been developed for the quantification of two herbicides (ethidimuron and methabenzthiazuron) and their two main soil derivatives. This method involves fluidized-bed extraction (FBE) prior to cleanup and analysis by reverse-phase liquid chromatography with UV detection at 282 nm. FBE conditions were established to provide efficient extraction without degradation of the four analytes. (14)C-labeled compounds were used for the optimization of extraction and purification steps and for the determination of related efficiencies. Extraction was optimal using a fexIKA extractor operating at 110 degrees C for three cycles (total time = 95 min) with 75 g of soil and 150 mL of a 60:40 v/v acetone/water mixture. Extracts were further purified on a 500 mg silica SPE cartridge. Separation was performed on a C18 Purosphere column (250 mm x 4 mm i.d.), at 0.8 mL min(-1) and 30 degrees C with an elution gradient made up of phosphoric acid aqueous solution (pH 2.2) and acetonitrile. Calibration curves were found to be linear in the 0.5-50 mg L(-1) concentration range. Besides freshly spiked soil samples, method validation included the analysis of samples with aged residues. Recovery values, determined from spiked samples, were close to 100%. Limits of detection ranged between 2 and 3 microg kg(-1) of dry soil and limits of quantification between 8 and 10 microg kg(-1) of dry soil. An attempt to improve these performances by using fluorescence detection following postcolumn derivatization by orthophthalaldehyde-mercaptoethanol reagent was unsuccessful.  相似文献   

6.
The separation and determination of tocopherols (Ts) and tocotrienols (T3s) by reversed-phase high-performance liquid chromatography with fluorescence detection has been developed and validated after optimization of various chromatographic conditions and other experimental parameters. Analytes were separated on a PerfectSil Target ODS-3 (250 × 4.6 mm, 3 μm) column filled with a novel sorbent material of ultrapure silica gel. The separation of Ts and T3s was optimized in terms of mobile-phase composition and column temperature on the basis of the best compromise among efficiency, resolution, and analysis time. Using a gradient elution of mobile phase composed of isopropanol/water and 7 °C column temperature, a satisfactory resolution was achieved within 62 min. For the quantitative determination, α-T acetate (50 μg/mL) was used as the internal standard. Detection limits ranged from 0.27 μg/mL (γ-T) to 0.76 μg/mL (γ-T3). The validation of the method was examined performing intraday (n = 5) and interday (n = 3) assays and was found to be satisfactory, with high accuracy and precision results. Solid-phase extraction provided high relative extraction recoveries from cereal samples: 87.0% for γ-T3 and 115.5% for δ-T. The method was successfully applied to cereals, such as durum wheat, bread wheat, rice, barley, oat, rye, and corn.  相似文献   

7.
An ultrasensitive and selective high-performance liquid chromatographic method for the volatile signaling hormone, jasmonic acid, has been developed based on precolumn derivatization with 1,3,5,7-tetramethyl-8-aminozide-difluoroboradiaza-s-indacene (BODIPY-aminozide). The derivatization reaction was carried out at 60 °C for 30 min in the presence of phosphoric acid. The formed jasmonic acid derivative was eluted using a mobile phase of methanol/pH 6.50 ammonium formate buffer/tetrahydrofuran (67:30:3, v/v/v) in 10 min on a C(18) column and detected with fluorescence detection at excitation and emission wavelengths of 495 and 505 nm, respectively. The detection limit (signal-to-noise ratio = 4) reached 1.14 × 10(-10) M or 2.29 fmol per injection (20 μL), which is the lowest of the existing methods. The proposed method has been successfully applied to the direct determination of trace jasmonic acid in the crude extracts of soybean leaves from soybean mosaic virus-infected and normal plants with recoveries of 95-104%.  相似文献   

8.
A simple and sensitive method has been developed for determining rutin, catechin, epicatechin, and epicatechin gallate in buckwheat (Fagopyrum esculentum Moench) flour and seeds by micro-high-performance liquid chromatography with electrochemical detection. Chromatography was performed using an octadecylsilica column, acetonitrile-water-formic acid (13:87:1, v/v/v) as a mobile phase, and an applied potential at +0.5 V vs Ag/AgCl. We found that Japanese buckwheat flour contains rutin (12.7 mg/100 g), catechin (3.30 mg/100 g), epicatechin (20.5 mg/100 g), and epicatechin gallate (1.27 mg/100 g). The relative standard deviations for rutin, catechin, epicatechin, and epicatechin gallate peak heights were less than 0.86% (n = 5). The detection limit of rutin was 0.86 ng/mL. Moreover, the present method was applied to the distribution analysis of these compounds in buckwheat seed. The embryo proper and cotyledons of a mature buckwheat seed contained rutin with the highest concentration as compared to other parts. This method is useful in determining rutin, catechin, epicatechin, and epicatechin gallate in buckwheat with a small amount of sample for quality control in the food industry.  相似文献   

9.
A reverse phase liquid chromatographic (LC) method has been developed for the assay of calcium pantothenate in commercial multivitamin tablet formulations and raw materials. The assay was validated according to the Pharmaceutical Manufacturers Association Quality Control HPLC Committee guidelines. The chromatographic system includes a C-18 column and a mobile phase consisting of 0.25M sodium phosphate buffer, pH 2.5, and acetonitrile (97 + 3 v/v). The column effluent is monitored by UV detection at 205 nm. The sample preparation involves only extraction in water followed by filtration. The method is stability-indicating with a detection limit of approximately 50 ng/mL of the calcium pantothenate in the samples. The system is linear from at least 0.02 to 0.10 mg/mL. The mean recovery of spiked placebos ranged from 98.7 to 99.8%. The within-day precision of the assay on finished products (N = 6) ranged from 0.3 to 2.0% CV. A system suitability criterion for resolution is based on the separation between calcium pantothenate and 2 closely eluting compounds, saccharin and a saccharin degradation product, 2-sulfamoylbenzoic acid.  相似文献   

10.
A reverse-phase liquid chromatographic method is described for the assay of medroxyprogesterone acetate in tablets. An octadecylsilane (C18) column with a mobile phase of methanol-0.01M dibasic ammonium phosphate (80 + 20 v/v, pH 7.2 +/- 0.1) and photometric detection at 254 nm separates medroxyprogesterone acetate from excipients. Detector responses were linear to concentrations of medroxyprogesterone acetate over the range 50-150 micrograms/mL (r = 0.999). Mean recovery of medroxyprogesterone acetate added to tablet excipients was 100.8%. Mean assay results were 101.3% (n = 3). The assay results are comparable to those obtained by the compendial liquid chromatographic method.  相似文献   

11.
The objectives of this study were to develop a high-performance liquid chromatography method for analysis of carotenoids in spear shrimp shells (Parapenaeopsis hardwickii) and to compare the extraction efficiency of carotenoids by supercritical carbon dioxide (SCD) and solvents. Results showed that the most appropriate HPLC method was accomplished by employing a Cosmosil 5C18-AR-II column and a mobile phase of methanol-dichloromethane-acetonitrile (90:5:5, v/v/v) (A) and water (100%) (B) with the following gradient elution: 92% A and 8% B in the beginning, decreased to 4% B in 9.5 min, 1% B in 26 min, 0% B in 35 min, maintained for 25 min, and returned to 92% A and 8% B in 61 min. All-trans-astaxanthin and its two cis isomers, as well as five astaxanthin monoesters and 11 diesters were resolved within 60 min with a flow rate at 2 mL/min and detection at 480 nm. Astaxanthin diesters were found to contain 12 fatty acids, of which palmitic acid and stearic acid constituted a large portion, whereas astaxanthin monoesters were found to contain 10 fatty acids with arachidonic acid dominating. Solvent extraction could generate a higher content of trans-astaxanthin and astaxanthin esters, while SCD extraction could produce greater levels of 9-cis-astaxanthin and 13-cis-astaxanthin.  相似文献   

12.
A rapid and simple immunochemical method was developed for the assessment of the creatine kinase (MM) isoenzyme [CK(MM)], a protein marker linked with animal welfare and meat quality. The one-step time-resolved immunofluorometric assay produced quantitative results from serum or whole blood samples in 20 min. The analytical limit of detection (mean + 2s) for the immunoassay was 17 ng/mL (n = 6), and the functional limit of detection for the analysis of porcine whole blood samples was 426 ng/mL (n = 24). The working range of the method was linear up to 50 micro g/mL, and the within-assay precision varied between 2.1 and 10.9%. The analysis of porcine serum samples showed that the results from the immunoassay method and colorimetric CK enzyme activity determination were highly correlated (r(2) = 0.965, n = 17, p < 0.001). The practicability of the assay was demonstrated by the analysis of 300 porcine whole blood samples in a slaughterhouse environment.  相似文献   

13.
A reverse-phase liquid chromatographic (LC) method is described for simultaneously determining 5 coccidiostats--aklomide, dinsed, ethopabate, nitromide, and zoalene in chicken liver. The method entails blender extraction of 10 g liver with ethyl acetate, column chromatography through Sephadex LH-20 and neutral alumina, and LC analysis on a C18 column with UV detection at 260 nm. The drugs were eluted from Sephadex with methanol-benzene (10 + 90), from alumina with methanol-dichloromethane (10 + 90), and from C18 with acetonitrile-water (linear gradient: 25% acetonitrile for 10 min, increasing to 55% over 15 min; flow rate 1 mL/min). Liquid chromatography was completed in 40 min and calculations were based on peak height measurements. Average recoveries of the coccidiostats from fortified liver ranged from 72 to 97%, except for dinsed, which showed a relatively constant average recovery of 57%. The detection limit for the standards was 2.5 ng on column. Levels as low as 50 ng/g were detected in fortified liver samples.  相似文献   

14.
通过比较不同的提取溶剂和使用量,就水体中毒死蜱和TCP残留提取的效果及不同的流动相组成和比例对毒死蜱和TCP测定的影响,建立了水体中毒死蜱及TCP的HPLC残留分析方法。结果表明,水体中毒死蜱和TCP最佳提取溶剂为乙酸乙酯,提取次数为2次,用量分别为50和30mL。色谱条件为:流动相为甲醇:水=90:10或乙腈:水=90:10,流速1mL·min^-1;紫外检测波长300nm。当流动相为甲醇:水=90:10时,毒死蜱和TCP的保留时间分别为6.4和3.6min;当流动相为乙腈:水=90:10时,其保留时间分别为5.6和2.5min。毒死蜱和TCP的检出限分别为0.5和0.15ng。当毒死蜱和TCP在水中的添加浓度为0.01~5mg·L^-1时,标准添加回收率分别为91.4%-105.1%和90.6%~105.4%,变异系数分别为0.99%~4.12%和0.29%~9.33%。水样中毒死蜱和TCP的最小检出浓度分别为2和0.6ng·mL^-1。  相似文献   

15.
陈虹  钟明  唐昊冶  韩勇  靳伟 《土壤》2016,48(2):337-342
用50 ml甲醇︰0.05 mol/L硼砂溶液(p H=10)(9︰1,v/v)作为提取剂对20 g(或适量)土壤样品中残留的二氯喹啉酸振荡提取2 h,离心过滤后分取滤液25 ml浓缩,甲醇定容至2 ml,再用滤膜过滤后待测定;高效液相色谱仪(HPLC)以1.0 ml/min的甲醇︰1%乙酸水溶液(55︰45,V/V)为流动相,柱温45℃,在238 nm的紫外光波长下进行二氯喹啉酸的外标法定量。该方法精密度为6.0%,检出限为0.012 mg/kg,不同类型土壤的加标回收率74.9%~98.8%,能满足有机分析要求。该方法既简捷易操作,又能满足土壤中二氯喹啉酸低残留量的测定。  相似文献   

16.
A competitive enzyme-linked immunosorbent assay (ELISA) for pentachloronitrobenzene (PCNB), a fungicide and chemical intermediate, was developed using a polyclonal antiserum produced against a hapten-protein conjugate of pentachlorophenoxypropionic acid-bovine serum albumin (BSA). An indirect competitive ELISA of PCNB showed an IC50 of 37 ng/mL and a limit of detection (LOD) of 7 ng/mL. The ELISA can tolerate up to 10% (v/v) methanol, 5% (v/v) acetonitrile, or 5% (v/v) acetone without significant fluctuation of Amax and IC50. The assay sensitivity showed little change in a range of pH from 6 to 8 and concentrations of 0.05-0.2 M NaCl in the assay buffer. Very low cross-reactivities were observed for some structurally related compounds except for hexachlorobenzene (12%). The average recoveries of PCNB from fortified well water, river water, and soil samples were in ranges of 88-94, 80-91, and 70-81%, respectively. The correlations between the gas chromatographic and ELISA results were excellent (r 2 >or= 0.97, slopes from 0.86 to 1.10) for those fortified samples. The ELISA is a good alternative tool for monitoring PCNB residues in environmental samples.  相似文献   

17.
Two competitive immunoassays, a laboratory assay based on microwell plates and a field test based on the use of polystyrene tubes, have been developed for the quantification of thiram in lettuces. Concerning the laboratory assay, the calibration curve for thiram had a linear range of 11 to 90 ng/mL and a detection limit of 5 ng/mL. Precision of the assay presented coefficient of variation values <9% and the recovery of thiram from lettuce averaged 89% across the range of the immunoassay method using 30 min extraction with water/acetone (50:50, v/v). The tube-based method was developed in order that an extract of lettuce, containing thiram at the MRL (8 ppm), would be found on the linear part of the standard curve. The calibration curve for thiram has a linear range of 100 to 800 ng/mL (1.39 to 11.1 ppm in lettuce) and a detection limit of 40 ng/mL.  相似文献   

18.
A new procedure with supercritical CO2 modified with 0.5 mL of water and 0.75 mL of 0.1 M HCl in situ and 0.75 mL of water on-line at 15 MPa and 50 degrees C for 45 min was applied for the extraction of bioavailable amino acids from soil samples. Total extraction time was 60 min, but more favorable conditions are even possible for selected groups of amino acids. All analytes were trapped into 20 mL of methanol with satisfactory recovery (94-104%) and determined using high-performance liquid chromatography with fluorometric detection on a Zorbax Eclipse column (4.6 x 75 mm, 3.5 microm) with Na2HPO4 and acetonitrile/methanol/water as a mobile phase. Linear calibration curves were obtained (r > 0.999 except 0.99823 for Ile) with lower limits of detection (S/N = 3) in the range from 1.54 pg (Gly) to 13.5 pg (Cy2) or from 18.6 fmol (Ser) to 64.8 fmol (Lys). Validation and repeatability data are also given. Comparable results were obtained with a robust, commonly used extraction method (0.5 M ammonium acetate, 60 min in shaker, followed by filtration and lyophilization). Limiting values of artificial release of amino acids were also determined for each soil sample to eliminate any false results to ensure that all extracted amino acids originate from soil solution and exchangeable bound positions of soil samples.  相似文献   

19.
An ultrahigh-performance liquid chromatography (UHPLC) tandem mass spectrometric (MS/MS) method was developed for the simultaneous quantification of 2-acetyl-4-tetrahydroxybutylimidazole (THI), 2- and 4-methylimidazoles (2-MI and 4-MI), and 5-hydroxymethylfurfural (HMF) in beverage samples. A C30 reversed-phase column was used in this method, providing sufficient retention and total resolution for all targeted analytes, with an MS/MS instrument operated in selected reaction monitoring (SRM) mode for sensitive and selective detection using isotope-labeled 4-methyl-d(3)-imidazole (4-MI-d(3)) as the internal standard (IS). This method demonstrates lower limit of quantification (LLOQ) at 1 ng/mL and coefficient of determination (r(2)) >0.999 for each analyte with a calibration range established from 1 to 500 ng/mL. This method also demonstrates excellent quantification accuracy (84.6-105% at 5 ng/mL, n = 7), precision (RSD < 7% at 5 ng/mL, n = 7), and recovery (88.8-99.5% at 10, 100, and 200 ng/mL, n = 3). Seventeen carbonated beverage samples were tested (n = 2) in this study including 13 dark-colored beverage samples with different flavors and varieties and 4 light-colored beverage samples. Three target analytes were quantified in these samples with concentrations in the range from 284 to 644 ng/mL for 4-MI and from 706 to 4940 ng/mL for HMF. THI was detected in only one sample at 6.35 ng/mL.  相似文献   

20.
A reverse-phase liquid chromatographic method is described for the assay of penicillin V potassium in tablets and powders for oral solution. Under isocratic conditions, the combined use of an octadecylsilane column, with a mobile phase composed of acetonitrile-methanol-0.01M monobasic potassium phosphate (21 + 4 + 75, v/v), and photometric detection at 225 nm, separated penicillin V potassium from excipients, related compounds, and degradation products. Sulfadimethoxine was used as an internal standard. Detector responses were linearly related to concentrations of penicillin V over the range 25-225 micrograms/mL (r = 0.99997). Standard addition recoveries ranged from 98.8 to 99.9% (mean 99.5%, n = 8) for tablets and from 97.9 to 101.6% (mean 99.8%, n = 8) for powders for oral solution. The liquid chromatographic assay results were compared with those obtained by the official iodometric titration method. The proposed method is simple, selective, stability-indicating, and free from interference by excipients and degradation products.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号