首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Based on an actual ground source heat pump system in hot summer and cold winter area, the system operation parameters were tested for 6 years under the state of using cooling tower for cooling in summer but the ground heat exchanger and fire pool for heating in winter. A three dimensional (3D) tube group model was established, and the thermal balance analysis and calculation of the ground temperature distribution around the ground heat exchanger were conducted by the numerical calculation. According to the comparison between the test data and the theoretical results, the influencing factors of the ground adjustment ability were obtained.  相似文献   

2.
地埋管地源热泵换热器的换热性能受到不同地质结构的影响。以武汉和重庆地区的典型地质构成为边界条件,建立了三维地埋管的单孔双U管换热模型,通过模型计算,获得了两种地质条件下的地埋管换热性能,以重庆地区的地源热泵热响应测试结果以及工程运行数据出发,对模型的计算结果进行了验证,结果表明,模型吻合度较好,可以应用于工程分析。以模型为条件,进行地质结构对换热性能的影响度分析,预测了两地地埋管地源热泵的换热性能并计算得到换热器的平均换热系数分别为武汉地区K1=1.65(W/m·K),重庆地区K2=1.51(W/m·K)。  相似文献   

3.
This paper analyzes the fluid flow and heat transfer of the heat exchanger, and obtainsd the distribution of fluid field, heat field and pressure field in heat exchanger. According the analysis result, some modify measure is adopted, such as decreasing the number of tube bundle, the size of baffle plate and increasing the diameter of exchange heat tube. In the new heat exchanger, the resistance decreased 32.3%, is 103.2 Pa and the temperature of the exit is 130 K. The new heat exchanger satisfies the requirement of exchanging heat. The study indicates that adopting the numerical simulation method could get temperature, pressure and fluid - velocity of anywhere of the heat exchanger, and understand effecfing of structure parameter on fluid flied and heat flied of the heat exchanger. Therefore, it provides a new method for optimization design of heat exchanger.  相似文献   

4.
By the calculation and experiment,analysed the heat transfer characteristies in waste gas of the high temperature exchanger.The results which the reasonable vertical and horizontal distances were obtained,these turned out that the metallic rediation net was the effectve method intensified heat transfer in hot waste gas.The infulence of the velcity and temperature of waste gas on the multiple heat transfer caefficrent of the exchanger was studied by the experiment data.  相似文献   

5.
The physical and mathematical model of three dimensional unsteady coupled heat transfer in the ground heat exchanger is proposed, and corresponding numerical simulations for actual ground heat exchanger and operation condition are carried out. The computed results are compared with those of the thermal resistance test of the ground heat exchanger, which proves the correctness of the model and corresponding numerical methods. Then, the effects of thermal conductivity and specific heat of the ground backfill material on the ground heat exchanger are investigated, which provides theoretical guidance for the thermal response test and the engineering design of the ground heat exchanger.  相似文献   

6.
In terms of the theory of a transient energy balance on the finite controlled volume, in this paper, a transient three-dimensional heat transfer model for the simulation of a single vertical U-tube ground heat exchanger based on finite-difference methods is systematically proposed. The model is also compared with experimental results during the heating operation in winter. What's more,based on test data and domestic and foreign literature, the equations to determine the undisturbed ground temperature for wet and heavy soil in Chongqing are presented. These formulae are essential conditions to calculate the heat transfer model.  相似文献   

7.
This paper describes the double layer horizontal ground source heat pump systems constructed in 1998 with the buried depth of 0.9 m and 1.8 m. The program of study includes experimental equipments, heat exchanger size, testing meter and methods for data analysis. In addition, the heating and cooling performance at typical days are also illustrated. Among the influencing factors on the performance of the ground source heat pump systems, the parameter of heat exchanger and operation patterns of heat pump systems are analyzed.A heat transfer model has been set up for horizontal heat exchanger.  相似文献   

8.
The geothermal heat exchanger is the key component of ground coupled heat pump systems. We discuss the key parameters method of calculating geothermal heat exchanger length based on line source theory. Typical meteorological year data is used to determine the hottest month, the coldest month and annual average surface temperature. The building hourly load can be obtained by introducing the concept of equilibrium temperature. The cooling fraction and the heating fraction then can be calculated using building hourly load and performance parameters curve fit of a water source heat pump unit. The method for selecting the hottest and lowest entering fluid temperature and calculating the borehole and ground thermal resistance is given. A vertical U tube heat exchanger length calculation procedure is proposed.  相似文献   

9.
长沙城市热岛的成因分析   总被引:1,自引:1,他引:0  
为了缓解长沙热岛效应的技术措施的制定,利用调查试验等基本数据,对长沙市热岛形成原因进行分析。结果表明:长沙城市热岛强度随建城区面积的扩大而加强,热岛效应影响的范围和向外扩展的趋势与城市建城区的轮廓及城市向外发展的趋势相一致;长沙城区内部结构特征和下垫面的热性质为城市热岛的形成奠定了基础;城区人为热源增加,增加了城区大气中的热量,促进城市热岛形成;排放的大气污染物和粉尘烟尘,若以“尘罩”或“气罩”的形式覆盖在长沙城区的低空层,阻挡城区地面长波辐射的散发,反过来增加大气对地面的长波辐射,有利热岛形成;长沙城市热岛一般出现在晴朗、无风(或微风),大气层结稳定,空气湍流运动较弱的天气条件下,若空气垂直运动剧烈,或降雨持续时长,降水量大,或地面风速超过4 m/s的天气下,长沙城区不存在热岛现象。长沙城市热岛出现与否,天气气候条件起着重要的作用。  相似文献   

10.
This paper conducts in-tube heat transfer experiments in a three dimensional fin tube with 102 mm outer diameter.Compared with the smooth tube,the heat transfer enhancement ratio is between 1.65 and 1.7,and the pressure drop ratio is between 1.65 and 1.7.Based on the analysis of the heat transfer and tube surface temperature,a new type heat exchanger is put forward.Moreover,the design and calculation method is explored.The engineering example indicate that not only the tube surface temperature is higher than the smooth tube,but also the quantity of heat is increased by about 20% than the smooth tube.Compared with other types,the new type heat exchanger has a overall better performance.  相似文献   

11.
Combined image method with heat source function method,heat conduction due to moving heat sources is analysed in semi infinite body and cylinder with heat exchanging on its surface.The distribution of temperature is obtained when the wall temperature is constant and the wall heat flux is zero.The result is useful for engineering calculation.  相似文献   

12.
The heat transfer process in the louvered fin heat exchanger is analyzed,and the corresponding physical and mathematical models on the coupled conduction-convective heat transfer for the louver fin geometry are proposed.The control volume-based finite element method(CVFEM) is employed to solve numerically the problem.The computed(results) reveal the flow structure and heat transfer in the geometry in detail.Compared with the empirical correlation of heat transfer and friction coefficients previously proposed,the computed results show better consistency with the experimental results.  相似文献   

13.
River water quality is one of the important conditions must be considered when river water source heat pump is used. It is also the key factor of efficiency of river water source heat pump. Based on analysis of the water quality factors which influence the river water source heat pump heat exchanger fouling, the main quality indicators and value are conformed. Using fuzzy comprehensive evaluation method and the actual monitoring data, quality classification of river water which is the source of water source heat pump is analyzed. For the difficulty of multiple indicators which need to detect and meet the related national standard in practical engineering application, the definition of scaling potential value is put forward. As the water quality comprehensive evaluation index of water source heat pump, the scaling potential value not only can consider the influence of the main water quality parameters on water source heat pump heat exchanger fouling, but also can conveniently and quickly provide direct basis for water quality judgment and system selection in the engineering application.  相似文献   

14.
为解决地铁站冷却塔设置难题,提出了一种采用低速电机驱动旋转布水装置的间接蒸发冷却器,在两种布置方式下,对其换热性能进行了单因素实验,并运用正交实验法对较优布置方式下影响换热器换热的因素进行了分析。结果表明:两种布置方式下,喷嘴与蒸发冷却器的间距、两组换热管束间距均存在最佳值,喷嘴双侧旋转布水优于单侧旋转布水;换热器平行气流布置且喷嘴双侧旋转布水为较优布置方式,此时,换热器换热量随喷水量、转速、空气速度、冷却水进口温度的增加以及喷水温度、空气温度的降低而增大,其中,冷却水进口温度对换热器换热影响最为显著,其他因素对其换热的影响从主到次顺序为:喷水量、空气温度、空气速度、喷水温度、转速、冷却水流量。  相似文献   

15.
High thermal resistance resulted by fouling in heat exchanger restricts the application of sewage source heat pump (SSHP) system. The fouling forming mechanism was applied with solid-liquid fluidized bed technique for fouling prevention and removing of SSHP system. Shearing stress model of solid-liquid fluidized bed heat-exchanger is analyzed, and collision stress model is modified. Preventing and removing fouling mechanisms of solid-liquid fluidized bed technique by shearing stress and collision stress was explained. An experimental study on how to solve the fouling problem (such as fouling prevention and removing, heat transfer enhancement, etc) is discussed. The results of theory and experiment show that solid-liquid fluidized bed technique can be used not only to increase convection coefficient, but also to restrict fouling growing, it can effectively solve the fouling problem in SSHP system.  相似文献   

16.
The concept of loss rate of available energy was introduced for evaluating heat exchanger performance. At the same time, the general expression of loss rate of available energy was obtained for heat exchangers of several typical. And NL criteria was recommended for evaluation of the loss rate of available energy of heat exchanger. Then. the influences of inlet temperatures ratio, heat capacity ratio of fluids, the number of heat transfer units and flow patterns of heat exchanger on ,VL criteria were also discussed.  相似文献   

17.
The experimental study of the flow resistance and heat transfer characteristics are conducted for water and ethylene glycol solution (66% Wt) flowing in the heat exchanger with small rectangular microchannels . The heat exchanger having the channels of 0.4 mm in width, 2.0 mm in height, and 20 mm in length is heated by a hearing rod at the bottom surface, the upper and two side surfaces are adiabatic. During experiments, the Reynolds number are ranged from 2 to 2 500. The experimental results show that the flow friction factor decreases and Nusselt number increases with increasing Reynolds number for water and ethylene glycol solution. At a fixed Reynolds number, the Nusselt number for ethylene glycol solution with larger Prandtl number is greater than that for water. Meanwhile, the correlations of flow resistance and heat transfer in the heat exchanger with small channels are obtained for engineering application.  相似文献   

18.
In this paper,the comparative experimental research that air flows through theout-surface of a single row finned tubes is done in a drawing wind tunnel and the three differnetshapes of rectangluar finned tubes are compared with a plain finned tube that is usually used in therefrigerant heat exchanger, the useful results are obtained. The results show that,in the range ofwind velocity flowing through the marrowest area, W_(max)=2.5m/s to 8.5m/s,the average convec-tion heat transfer coefficient of the two-side V-groove finned tube is higher than that of rectangluarplain finned tube,It is a new type finned tube that has good heat transfer performance and it isworth poplarlzing.  相似文献   

19.
苏北地区日光温室能量分配动态研究   总被引:1,自引:1,他引:0  
为了进一步提高日光温室保温性能,减轻温室内低温寡照灾害发生,以苏北(徐州)番茄日光温室为研究对象,利用采集的2010年12月-2011年4月温室小气候数据及番茄发育数据,根据日光温室小气候形成的物理过程与机理,系统研究了冬春季节不同天气类型及不同叶面积指数对温室能量分配的影响。结果表明:日光温室内潜热、显热随着室内总辐射量的改变而发生变化,阴天以显热消耗为主,潜热消耗量全天低于显热;晴天日光温室内用于作物蒸腾的能量显著多于阴天,阴天室内外贯流传热消耗的能量远远多于晴天;随着叶面积指数增大,到达地面的太阳辐射减少,地面升温慢,室内空气与地表的显热交换量减少,同时室内空气与墙体的显热交换增加。本研究结果可为温室的结构优化及冬春季节日光温室管理提供科学依据。  相似文献   

20.
Soil temperature prediction model around the subway metro tunnels is constructed with the consideration of coupled heat transfer between range temperature and surrounding soil. Finite difference method is adopted for numerical solution of the model, and the solving results in certain conditions are compared to validate the analytical solution. The high-frequency thermal disturbance brought by train operation is simplified into three different forms, and the predictive model of soil temperature is used to calculate the corresponding soil temperature response. It is indicated that temperature fluctuations of range air and the wall are accompanied with high-frequency thermal disturbance, but the impact on soil temperature distribution inside is limited.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏