首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Sera from Canadian pigs (brucellosis free, n = 14037) and sera from pigs infected with Brucella suis (n = 401) were tested by the buffered antigen plate agglutination test, the complement fixation test, an indirect and a competitive enzyme immunoassay and a fluorescence polarization assay. The results were analysed and assay sensitivity and specificity estimates were calculated. The sensitivity and specificity of the tests were as follows: the buffered antigen plate agglutination test, 77.1 and 96.9%; the complement fixation test (considering anticomplementary sera as negative), 93.3 and 95.5%; the complement fixation test (considering anticomplementary sera as positive), 58.1 and 99.9%; the indirect enzyme immunoassay, 94.0 and 97.9%; the competitive enzyme immunoassay, 90.8 and 96.6%; and the fluorescence polarization assay, 93.5 and 97.2%; respectively. It was concluded that the fluorescence polarization assay was a valuable asset to the diagnosis of porcine brucellosis because of its accuracy, ease of performance and relative cost.  相似文献   

2.
Serologic virus neutralization tests, indirect immunofluorescence tests, and ELISA, using tissue culture-adapted feline infectious peritonitis virus (FIPV) or feline enteric coronavirus (FECV) were compared for their ability to distinguish specific virus exposure in cats. Sera of specific-pathogen-free cats inoculated with virulent or modified FIPV or FECV were used to compare the sensitivity and specificity of the homologous assays to a heterologous assay that measures antibody reactivity with transmissible gastroenteritis virus of swine. The geometric means of the serologic titers in FIPV and FECV assays were higher for FIPV- or FECV-infected specific-pathogen-free cats than the geometric means of the transmissible gastroenteritis virus assays for most groups. None of the assays was specific enough to discern the virus to which a cat had been exposed. However, the FIPV virus neutralization test appeared to be more sensitive for detection of an early response to FIPV infection than did the FIPV immunofluorescence test or FIPV-ELISA.  相似文献   

3.
A maedi-visna virus CA-TM fusion protein ELISA (MVV ELISA) was evaluated for the detection of antibody in sheep infected with North American ovine lentivirus (OvLV). The results of the MVV ELISA were compared with other assays for OvLV antibody and with viral infection in an intensively studied group of 38 sheep with a high prevalence of OvLV infection and disease. The sensitivity, specificity, and concordance of assays for OvLV antibody (MVV ELISA, indirect ELISA, Western blot, and AGID), virus (virus isolation, PCR, antigen ELISA), and OvLV-induced disease in each animal were compared with OvLV infection status as defined by a positive result in two or more of the assays. Five sheep met the criteria for absence of OvLV infection. The sensitivity of the MVV ELISA in detecting OvLV infected sheep was 64%, whereas the sensitivity of the other three tests for antibody ranged from 85 to 94%. All the antibody assays were 100% specific in this group of animals. Of the assays for virus, the PCR test had the highest sensitivity and the best concordance with OvLV infection, but it also had the lowest specificity of any of the virus or antibody assays. Among the antibody tests, the concordance of the MVV ELISA compared most favorably with the AGID test for detecting OvLV-infected sheep. Analysis of serum samples from 28 lambs experimentally-infected with one of three North American strains of OvLV suggested that there were no significant strain differences detectable by antibody assay. Twenty virus-inoculated lambs were positive by both the MVV ELISA and the AGID test, five lambs were MVV ELISA negative and AGID test positive, and three lambs were MVV ELISA positive and AGID test negative. No pre-inoculation samples were positive by either assay. In a longitudinal study involving seven lambs, antibodies to OvLV were detected by AGID 3-5 weeks post-inoculation, but were not detected by MVV ELISA until 5-10 weeks post-inoculation. Among 128 naturally and experimentally-infected sheep that were seropositive in the AGID test, the overall sensitivity of the MVV ELISA was higher in the naturally infected sheep (84%) than in the experimentally infected sheep (69%). The data indicated that the MVV ELISA represents a less sensitive, but specific alternative for the detection of OvLV antibodies.  相似文献   

4.
Immunofluorescence, tube agglutination, and platelet factor-3 immunoinjury tests for detecting antiplatelet antibody were compared using a heterologous system of equine platelets and rabbit antiequine platelet serum. Platelet immunofluorescence tests were performed using paratormaldehyde-fixed platelets in suspension as well as in air-dried smears on glass slides (solid phase). Bright homogeneous, membranous, specific fluorescence was seen in both assays with anti-immunoglobulin G (IgG) and protein G fluorescein isothiocynate conjugates (FITC-conjugates). Protein A conjugate gave nonspecific fluorescence irrespective of normal or antiserum treatment. Anti-IgG and protein G conjugates in suspension immunofluorescence tests with the same antiserum yielded antibody titers of 1:1024 and 1:128, respectively. Similarly, respective titers of 1:512 and 1:64 were obtained with solid phase immunoassay. Platelet suspension assay was slightly better than the solid phase assay. These observations indicated that anti-IgG was more sensitive than protein G in detecting antiplatelet antibody by fluorescence microscopy, while protein A was ineffective because of its nonspecificity. Chloroquine treatment of platelets failed to reduce the nonspecific fluorescence. Platelet agglutination and platelet factor-3 tests were relatively less sensitive to detect equine antiplatelet antibody.  相似文献   

5.
将国内广泛用于预防羊布病的S2和M5疫苗免疫绵羊,然后定期采血进行细菌分离和血清学检测,并比较血清学方法的检测结果。结果表明ELISA操作方便,具有较好的敏感性和特异性,建议在检疫中用敏感性较高的RBT初筛,用特异性较好的ELISA确诊,以得到较好的效果。  相似文献   

6.
We intended to identify relevant immunoallergic factors and to compare skin prick tests (SPTs) and in vitro allergy tests in the characterization of horses with recurrent airway obstruction (RAO), so as to ascertain that SPTs perform better. Forty Lusitano/cross-Lusitano horses (30 RAO cases and 10 healthy control horses)—a very valuable autochthonous breed—were studied. Clinical history, thoracic radiography, respiratory tract endoscopy, and bronchoalveolar lavage were used for diagnosis. Serum samples of all 40 horses and undiluted bronchoalveolar lavage fluid samples of 21 RAO horses and 6 control horses were submitted for evaluation by an allergen-specific immunoglobulin E (IgE) enzyme-linked immunosorbent assay. SPTs were performed on the 40 horses. Sensitivity, specificity, positive predictive value, and negative predictive value were calculated for all diagnostic methods. Agreement between diagnostic methods was assessed by kappa statistic (Κ). Chi-square test with Yates correction showed SPT results from the RAO and control groups to be statistically different (P < .05). SPTs showed higher sensitivity, specificity, positive predictive value, and negative predictive value than both enzyme-linked immunosorbent assay tests. In human medicine, SPTs are considered to be the gold standard of allergy tests. Neither serum IgE nor bronchoalveolar lavage fluid IgE reliably detected allergen hypersensitivity, compared with SPT. SPTs performed significantly better overall than both in vitro tests. Low sensitivity of the in vitro assays indicates the need for continued study to elucidate a more sensitive specific IgE test.  相似文献   

7.
This paper describes the development of an indirect immunoperoxidase assay (IIP) and an indirect enzyme-linked immunosorbent assay (ELISA) for detecting antibodies to chicken anemia virus (VAC). The IIP assay developed used CAV-infected MDCC-MSB1 cells for detecting antibody to CAV, whereas the ELISA utilized gradient-purified immunoadsorbed CAV as the target antigen. The IIP and ELISA were compared with the standard indirect immunofluorescent antibody (IFA) assay, which is more conventionally used to screen chicken serum for antibodies against CAV. Comparative test results of 185 field samples of chicken serum by these three methods were in agreement 84% of the time. Both IFA and IIP assays yielded fewer positive tests than did the ELISA. IFA and IIP assays were in agreement 93% of the time, as compared with 91% agreement of IIP and ELISA results, or 84% agreement for comparative IFA and ELISA results.  相似文献   

8.
The aim of this study was to compare the performance of three in-house diagnostic tests, i.e. counter current immunoelectrophoresis (CCIE), intradermal (ID) and indirect fluorescent immunoassay (IFI), for the diagnosis of Heterophyes infection. One hundred and twenty puppies were randomly divided into eight groups (n=15/group). Heterophyes heterophyes infections were established in these puppies by administering a dose of 50 H. heterophyes encysted metacercariae/puppy by gavage. Forty puppies of similar age and sex were divided into eight groups, of five puppies each and were used as negative controls. Sera pooled from separate infected and uninfected groups were tested against H. heterophyes antigens, weekly for 8 weeks post-infection (PI). The ID assay detected infected puppies sooner than any of the serological tests. Sero-conversion was first detected 2 weeks PI by ID assay and 1 week later by CCIE and IFI assays. ID test performed well till the end of the experiment (sensitivity and specificity: 100% and 90%, respectively). Both IFI and CCIE assays had a sensitivity of 40% and 20%, respectively for early detection of antibody, which was less sensitive than ID but both assays were more specific (100%) than the ID assay. The lowest agreement was between ID and IFI tests (40.3%), whilst the highest was observed between CCIE and IFI tests (67.2%). Of the three evaluated methods, the ID test could be recommended for scientific and laboratory diagnosis of heterophyosis in naturally infected animals. However, since none of the investigated method are optimal (i.e, offers 100% specificity and sensitivity), the choice of test employed must depend on the aim of the study.  相似文献   

9.
重金属离子单克隆抗体及免疫检测研究进展   总被引:2,自引:0,他引:2  
重金属离子的免疫学检测是检测重金属离子的一种新方法,与传统检测方法相比,省时、便携、费用低、易操作,能用于重金属离子的现场快速检测。重金属离子的免疫检测分为多克隆抗体免疫检测和单克隆抗体免疫检测,包括荧光偏振免疫检测、酶联免疫吸附检测和免疫传感器检测。其中基于抗重金属离子—螯合剂复合物的单克隆抗体建立的免疫检测技术显示出很好的应用前景。  相似文献   

10.
The aims of this study were to evaluate the performance and agreement of various commercial and in-house Neospora caninum antibody assays used in dairy cattle in North America, and to investigate reproducibility of two assays performed in different laboratories. From 1998 to 2005, three enzyme linked immunosorbent assays (ELISAs, a competitive ELISA-VMRD Inc., an indirect ELISA-Biovet Inc., and another indirect ELISA-Herdchek IDEXX Corp.), two indirect fluorescent antibody tests (IFATs, VMRD Inc., and in-house USDA) and one N. caninum agglutination test (NAT, in-house USDA) were utilized to test 397 randomly selected dairy cattle serum samples from 34 herds in eastern Canada for antibodies to N. caninum. The manufacturers' recommended cut-off values were used to evaluate test performance and agreement between tests. One IFAT (VMRD Inc.) performed well (sensitivity and specificity: 0.97 and 0.97, respectively) using reference sera (n = 452), therefore, results from this IFAT on the 397 samples could subsequently be used as the reference standard to calculate test characteristics for the other assays. Only 11% of the 397 sera were found to be N. caninum-positive with the IFAT. Prevalence-adjusted bias-adjusted kappa (PABAK) ranged from 0.06 to 0.99. Positive agreement was moderate to very good (P(pos) = 0.25-0.96). Negative agreement was very good for all assays (P(neg) > 0.94) except NAT (P(neg) = 0.66). Sensitivity was > or =0.89 for all assays except the NAT, which had a significantly lower sensitivity (0.66). Specificity was high (>0.94) for all assays except for one indirect ELISA (specificity = 0.52). This indirect ELISA did not perform satisfactorily when used in 1998, but an improved version of the ELISA performed as one of the best assays in 2004. Reproducibility of the competitive ELISA was excellent, but the reproducibility of the indirect ELISA that was improved was low (concordance correlation coefficient = 0.90 and 0.36, respectively). The performance characteristics observed for most assays in this study make them useful for screening antibodies to N. caninum in cattle.  相似文献   

11.
A blocking enzyme-linked immunosorbent assay (ELISA) was developed to detect antibodies to porcine rubulavirus (La Piedad Michoacan Virus [LPMV]) in serum samples from pigs. The test, based on a monoclonal antibody against the LPMV hemagglutinin-neuraminidase glycoprotein, had a sensitivity of 99% and a specificity of 97%. The results of this test were in agreement with those obtained by an indirect ELISA and hemagglutination inhibition, indirect immunofluorescence, and virus neutralization tests. The blocking ELISA is considered the most suitable test for routine screening for antibodies against LPMV.  相似文献   

12.
OBJECTIVE: To estimate the sensitivity, specificity and detection limits for two bulk-milk enzyme-linked immunosorbent assays, the Svanovir BLV-gp51-Ab and the Lactelisa BLV Ab Bi indirect tank 250, for the detection of antibody to bovine leucosis virus in milk. PROCEDURE: Milk samples from 27 cows known to have enzootic bovine leucosis (EBL) were serially diluted with milk from a herd known to be free from the disease. The dilution at which antibodies could no longer be detected by each test was determined. A total of 1959 bulk-milk samples submitted to a laboratory for the Victorian (EBL) eradication program were tested with both the Svanovir and the Lactelisa assays. A Bayesian approach was used to calculate maximum-likelihood estimates of test sensitivity and specificity. An additional 660 bulk-milk samples were tested with both the Svanovir and the Lactelisa assays. Herds that had positive results on either or both of the assays were subjected to blood or milk testing of individual cattle. RESULTS: The dilution of milk at which the Svanovir assay failed to detect enzootic bovine leucosis antibody in half of the samples was 1 in 40, whereas the comparable value for the Lactelisa was 1 in 200. Computer modeling of the operating characteristics of the Svanovir assay indicated that the sensitivity of that assay would be considerably lower than that for the Lactelisa, and the specificity was estimated to be higher. Evaluation of the assays using 660 bulk-milk samples showed that the Lactelisa assay detected four infected herds that were not detected by the Svanovir test. No false positive results were recorded for either assay. CONCLUSION: Use of the Lactelisa assay in the Victorian EBL eradication program will enhance disease detection and eradication, but may also result in an increased frequency of false positive bulk-milk test results.  相似文献   

13.
The validation of assays for bovine immunodeficiency virus (BIV) in cattle is hampered by the absence of a gold standard. Two tests that often are used to detect BIV are the indirect fluorescent-antibody assay (IFA) and the nested-set polymerase chain-reaction assay (PCR). IFA detects an antibody response whereas PCR detects the provirus in white blood cells.Using Bayesian techniques performed simultaneously on animals from two different dairy herds, we estimated the performance of the IFA and PCR assays and infection prevalence. Bayesian techniques also were used to derive posterior distributions of sensitivities, specificities, and prevalences. The Bayesian estimates were IFA sensitivity=60%, IFA specificity=88%, PCR sensitivity=80%, PCR specificity=86%, Herd A prevalence=20%, and Herd B prevalence=71%. Although PCR was the more sensitive assay, substantial misclassification of infection would be expected in epidemiological studies of BIV regardless of which assay was used.  相似文献   

14.
In the present study, a collection of 415 water buffalo serum samples originating from the north of Vietnam was used for evaluation of different diagnostic antibody detection methods available to detect infections with Trypanosoma evansi. The diagnostic sensitivity and specificity of a direct card agglutination test (CATT/T. evansi), an indirect card agglutination test (LATEX/T. evansi) and a newly developed antibody detection ELISA (ELISA/T. evansi) was calculated on the basis of parasitological results, obtained by mouse inoculation, and compared for all assays. The immume trypanolysis assay with the predominant T. evansi RoTat 1.2 variable antigen type was used as reference test for antibody presence. All parasitologically confirmed animals (n=8) were positive in all tests. Diagnostic specificity was highest in CATT/T. evansi (98%) followed by the ELISA/T. evansi (95%) and the LATEX/T. evansi (82%). Concordance of the variant specific immune trypanolysis test with the other tests was calculated and revealed that few (1-8%) false positive results were actually due to a specific reactions, and that LATEX/T. evansi and ELISA/T. evansi detected more immune trypanolysis positives than the CATT/T. evansi. It was concluded that, apart from the immune trypanolysis test, which is not generally applicable, ELISA/T. evansi with a 30% positivity cut-off and LATEX/T. evansi, thanks to their superior capacity of detecting T. evansi specific antibodies, would be suitable as epidemiological tools detecting both active infections and persisting T. evansi specific antibodies. The ELISA/T. evansi with a 50% positivity cut-off and the CATT/T. evansi on the other hand, seem more appropriate to detect true infected water buffaloes.  相似文献   

15.
Bovine tuberculosis (bTB) is a zoonosis caused by Mycobacterium bovis. Test-and-cull protocols and gross pathological examinations of abattoir animals as well as milk pasteurization have been implemented to prevent the spread of tuberculosis from animals to humans worldwide. Despite the importance of precise and rapid diagnostic tests, conventional methods including intradermal skin tests and γ-interferon assays are limited by the high rate of false-negative results for cattle in the late infectious stage and due to laborious and time-consuming procedures. Therefore, antibody detection methods such as enzyme-linked immunosorbent assay (ELISA) are urgently needed to supplement the established approaches and expand the diagnostic window. This study was conducted to develop a bTB ELISA by evaluating recombinant and native proteins and various assay parameters. We produced recombinant MPB70 and SahH (M70S) and a native 20-kDa protein (20K) and optimized the ELISA protocol. The 20K ELISA showed 94.4% sensitivity and 98.2% specificity with an optimal sample-to-positive ratio cut-off of 0.531. The sensitivity and specificity of M70S ELISA were 94.4% and 97.3%, respectively, with an optimal sample-to-negative ratio cut-off of 1.696. Both assays showed acceptable diagnostic efficiency and could be used for bTB diagnosis in combination with established methods for herd screening and to expand the diagnostic window.  相似文献   

16.
Isolated Anaplasma marginale initial bodies were successfully used in a dot ELISA for rapid detection of antibodies to Anaplasma organisms. The enzyme immunoassay used only 25 ng of antigen dotted onto nitrocellulose disks. Antigen-antibody complexes were detected by use of alkaline phosphatase-conjugated protein A, and reactions were read visually after addition of a precipitable, chromogenic substrate. The test allowed the processing of multiple sera, either for screening or for titer determination, in less than 3 hours and was found to be as sensitive as the indirect fluorescent antibody test. The overall performance of the dot ELISA, using isolated A marginale initial bodies, for 580 bovine serum samples was as follows: sensitivity, 93%; specificity, 96%; and predictive value, 95%. Cross-reactivity was not observed with sera positive to Babesia bovis and B bigemina, Trypanosoma vivax, or common bacteria or viruses infecting cattle. The antigen dotted onto nitrocellulose disks was stable when stored at -20, 4, or 25 C. Compared with the indirect fluorescent antibody test, the dot ELISA allowed easier, faster, and more objective interpretation of results. Its simplicity and low cost combined with high sensitivity and specificity indicate that this assay could effectively replace serologic assays currently used for diagnosis of anaplasmosis in cattle.  相似文献   

17.
The current method for goat brucellosis diagnosis is based on the World Organization for Animal Health (OIE) using the screening card test (CT), with antigen at 8% (CT8) or 3% (CT3) of cell concentrations, and the confirmatory complement fixation test (CFT). However, these tests do not differentiate antibodies induced by vaccination from those derived from field infections by Brucella species or other bacterial agents; in places like Mexico, where the prevalence of brucellosis and the vaccination rates are high, there is a considerable percentage of false positive reactions that causes significant unnecessary slaughter of animals. Furthermore, results of the fluorescence polarization assay (FPA) using the Brucella abortus O-polysaccharide (OPS) tracer in goats are poorer than those with cattle. The present study was undertaken to investigate a tracer prepared from the native hapten (NH) of the Rev. 1 strain of Brucella melitensis to improve FPA performance on goat brucellosis diagnosis. Evaluation of 48 positive samples and 96 negative samples showed that the NH tracer was more accurate (p<0.01) than the OPS tracer (97.2% vs. 93.8% accuracy, respectively). On the diagnostic performance evaluation, the NH tracer performed better (87.5% accuracy, 79.5% sensitivity, 84.3% specificity, and 163.8 performance index) than the OPS tracer (83.5%, 75.9%, 81.0%, and 156.9, respectively) using 1009 positive and 2039 negative Mexican field goat sera samples selected by test series approved by the OIE (card test 3% and CFT). We demonstrated a new application for the NH lipopolysaccharide on detecting antibodies against Brucella using the FPA, which may yield faster results (minutes vs. 24-72h) than the immunodiagnosis assays frequently used in bovine brucellosis. In addition, NH tracer produces similar or better performance results than the conventional OPS tracer, using the FPA in goat sera samples.  相似文献   

18.
本试验采用121 ℃高压处理副猪嗜血杆菌4型和5型耐热蛋白,混合作为包被抗原,建立了检测副猪嗜血杆菌抗体的间接ELISA方法。通过对试验条件进行筛选优化,确定了最佳反应条件:抗原包被浓度为10 μg/mL,37 ℃包被2 h;封闭液选择含20 g/L脱脂奶粉的PBST,封闭30 min;血清的稀释度为1∶80;抗原抗体反应时间为45 min;酶标二抗稀释度为1∶12000,作用时间为30 min;底物显色时间为15 min。特异性、重复性和敏感性试验及对200份送检血清的检测结果表明,建立的间接ELISA方法特异性和重复性良好,敏感性比间接血凝试验高,对已知阴阳性血清的临床样本检测结果与国外ELISA试剂盒一致,可用于副猪嗜血杆菌的血清抗体检测和血清流行病学调查。  相似文献   

19.
Detection of infected poultry flocks is essential for controlling eggborne transmission of Salmonella enteritidis to humans. The present study evaluated the detection of antibodies in the sera of experimentally infected chickens by a fluorescence polarization assay with a tracer prepared from the O-polysaccharide of S. enteritidis and an enzyme-linked immunosorbent assay (ELISA) with an S. enteritidis flagellin antigen. In two trials, groups of specific-pathogen-free laying hens were infected orally with either 10(6) or 10(8) colony-forming units (CFU) of S. enteritidis (phage type 13a) or with 10(8) CFU of Salmonella typhimurium. Serum samples were collected before inoculation and at five subsequent weekly intervals. Both assays successfully detected the majority of hens infected with S. enteritidis at either dose level, but they also identified a substantial number of hens infected with S. typhimurium as seropositive. The fluorescence polarization test detected S. enteritidis infection significantly more often and cross-reacted with sera from hens infected with S. typhimurium significantly less often than the ELISA. The fluorescence polarization assay also offered advantages in terms of speed and methodologic simplicity.  相似文献   

20.
A blocking enzyme-linked immunosorbent assay (ELISA) test has been developed to distinguish pseudorabies virus (PRV) (Aujeszky's disease virus) -infected pigs from those immunized with a glycoprotein g92 (gIII) deletion mutant, PRV (dlg92dltk) [OMNIMARK-PRV]. This blocking ELISA test utilizes an anti-PRV gIII monoclonal antibody (mAbgIII)-horseradish peroxidase (HRPO) conjugate, TMB for color development and a cloned PRVg92 (gIII) antigen to coat wells of microtiter test plates. Undiluted sera are used to block the binding of the mAbgIII-HRPO conjugate to the antigen. The gIII blocking ELISA is specific and has a sensitivity comparable to screening ELISA and latex agglutination tests. PRV-negative sera and sera from pigs vaccinated once, twice, or four times with the gIII-negative vaccine all showed negative S/N values of greater than 0.70 (S/N defined as the optical density at 630 nm of test sera/optical density at 630 nm of negative control sera). Sera from PRV-infected herds, sera from pigs experimentally infected with virulent PRV, and sera from pigs vaccinated with modified-live or inactivated gIII+ vaccines were positive for gIII antibodies (S/N less than 0.7). Sera from pigs experimentally infected with 200 PFU virulent PRV seroconverted to gIII+ antibodies 7-10 days postinfection. Sera from pigs vaccinated with gpX- and gI- vaccines seroconverted to gIII+ antibodies 7-8 days after vaccination. The gIII antibodies persisted after gIII+ vaccinated for at least 376 days postvaccination. Sera from pigs protected by vaccination with PRV (dlg92dltk) and then challenge exposed to virulent PRV at 21 days postvaccination showed gIII+ antibodies by 14 days postchallenge. The specificity and sensitivity of the gIII blocking ELISA assay was further demonstrated on the United States Department of Agriculture-National Veterinary Services Laboratory (USDA-NVSL) sera from the 1988 PRV check set and the 1989 gIII PRV check set by comparing the gIII blocking ELISA assay with virus neutralization, screening/verification ELISA and latex agglutination assays.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号