 共查询到20条相似文献,搜索用时 31 毫秒
1.
Percutaneous ultrasound-guided liver biopsies were conducted in 15 snakes using 18-gauge automatic biopsy devices. The liver samples collected ranged in size from 1.16 ± 0.40 mm to 8.3 ± 0.55 mm. Upon histologic examination, all biopsy samples were of diagnostic quality. Anesthesia with complete immobilization of the snake was necessary to allow proper selection of the target site and limit complications associated with biopsy collection. Percutaneous ultrasound-guided liver biopsy is a rapid, minimally invasive method for collecting liver tissue in snakes.  相似文献   

2.
The purpose of this study was to develop a percutaneous lung biopsy technique to be used on steers in a commercial feedlot setting. Thirty-four crossbred steer and heifer calves from a commercial feedlot in southern Alberta were used in this study. The calves originated from the auction market and all were chronically affected with bovine respiratory disease (BRD). A technique was developed to obtain a lung sample from the right cranioventral lung lobe, intercostal space (ICS) 2, using a manual or an automatic biopsy instrument with a 14- or 12-gauge (ga) biopsy needle. Overall, lung parenchyma was successfully harvested in 55.9% of experimental animals and in 55.0% of lung biopsy trials. Compared with postmortem diagnosis, the biopsy resulted in the same pathologic diagnosis for 75% of biopsy samples when evaluated using standardized criteria by the same veterinary pathologist. The success rate was 61.5% and 42.9% in a hospital or field setting, respectively. With an automatic instrument, lung was recovered from 57.9% and 37.5% of samples obtained using a 12- or 14-ga biopsy needle, respectively. One experimental animal or 2.9% of the total had fatal complications from the procedure. In a commercial feedlot setting, the procedure took 20 min for each animal. Percutaneous lung biopsy of the right cranioventral lung lobe may be a viable technique when used on feedlot steers affected with chronic pneumonia. These findings suggest that using an automatic instrument with either a 14- or 12-ga biopsy needle may yield lung samples that are suitable for histopathological evaluation. However, this technique needs to be further evaluated in a field setting.  相似文献   

3.
This paper describes behavioral and physiological responses of pigs to shot biopsy, an experimental method used to study muscle tissue processes or to predict meat quality. One biopsy sample from the longissimus muscle was obtained from 23-wk-old gilts (n = 10) using a cannula connected to a captive bolt. Ten other gilts were used as a control and received a sham shot. One week later, a second biopsy was taken from the same gilts. Behavioral and salivary cortisol responses to both biopsies were similar (P > .10). Pigs flinched in response to the biopsies. Salivary cortisol concentrations were increased (P < .05) 15 min after the biopsy as compared with pretreatment levels, but absolute levels were not different (P > .10) from the control group. In both biopsy and control groups, heart rate increased (P < .001) in response to the presence of the technician. In response to the first biopsy, heart rate increased (P < .01) as compared with the rate during the 5-s period before the biopsy, but heart rate did not increase in response to the second biopsy. The biopsy pigs showed a decrease (P < .05) in initiating contact with the technician in the second test. We conclude that shot biopsy had a significant acute effect on behavior and heart rate. Therefore, the usefulness of this technique in studies in which the behavioral and heart rate responses are measured is limited.  相似文献   

4.
BACKGROUND: Liver biopsies taken with an automatic Tru-Cut biopsy gun device caused unexpected fatal shock reactions in cats. The goal of the present study was to determine if this biopsy device caused more frequent fatal complications than did a semiautomatic device. ANIMALS: All cats referred to the Utrecht University, between October 1, 2002, and October 31, 2004, in which ultrasound-guided Tru-Cut liver biopsies were taken. The indications for liver biopsy were increased liver enzyme activity, increased bile acid concentrations, ultrasonographic abnormalities of the liver, ultrasonographic abnormalities of the bile ducts, or some combination of these findings. Coagulation parameters were normal. METHODS: From October 1, 2002, until October 31, 2003, 26 cats were biopsied with an automatic biopsy device. Between November 1, 2003, and October 31, 2004, 19 cats underwent liver biopsy with a semiautomatic biopsy device. RESULTS: In the first period. 5 of the 26 cats (19%) developed severe shock within 15 minutes. Resuscitation was not successful. In the second period, none of the 19 cats experienced any major adverse effect. There were no significant differences between the 2 groups with respect to diagnosis, clinical signs, clinicopathologic findings, or the use of anesthetics. CONCLUSIONS AND CLINICAL IMPORTANCE: We conclude that the difference in complication rate is explained by the biopsy technique used. The pressure wave, which occurs when firing the automatic device, may have caused intense vagotonia and shock. Use of this automatic biopsy device should be avoided in cats because of the high risk of fatal complications.  相似文献   

5.
Naruepon  Kampa  DVM  Ursula  Wennstrom  DVM  Peter  Lord  BVSc  FRCVS  Robert  Twardock  DVM  PhD  Enn  Maripuu  BSc  Per  Eksell  DVM  PhD  Sten-Olof  Fredriksson  BSc 《Veterinary radiology & ultrasound》2002,43(4):383-391
Determinations of different methods of measurement of uptake of 99mTc-DTPA using scintigraphy of glomerular filtration rate (GFR) were made from 29 studies on 10 healthy beagle dogs. GFR was measured by calculating the percentage dose uptake (integral method) and rate of uptake (slope method) of 99mTc-DTPA using manual kidney regions of interest (ROI) and automatic kidney and background ROIs at different time periods of the uptake phase. These results were compared using linear regression analysis to the GFR obtained from 99mTc-DTPA plasma clearance using multiple blood samples. The best correlation coefficient between percentage DTPA uptake and GFR by DTPA clearance (r = 0.84, P < 0.001) was derived from time intervals between 30s-120s with a perirenal background ROI at 1 or 2 pixels out from the kidney ROI using automatic kidney ROI at 20% threshold. With the slope method, the best correlation coefficient (r = 0.85, P < 0.001) was obtained from time intervals between 30s-peak with the background ROI at 2 pixels out from the kidney ROI using automatic ROI at 35% threshold. The offset was higher, and the correlation varied more with different ROIs and the method was unreliable at time intervals extending beyond the peak radioactivity. Manual kidney ROIs with automatic background ROIs had slightly lower correlations. With DTPA renography both integral and slope uptake method with automatic kidney and background ROIs are accurate methods to estimate the GFR, but that the integral method is much more stable to variations in ROI size and the duration of the uptake phase of the renogram.  相似文献   

6.
Endometritis is the most common cause of infertility in mares; however, many mares fail to be diagnosed despite availability of many diagnostic tests. Our objective was to compare different diagnostic methods and establish a cutoff value for the number of polymorphonuclear cells in cytology samples. Fifty-four mares were classified positive for endometritis based on endometrial biopsy (“gold standard”), and in a later analysis, the mare was reclassified as positive for endometritis if two or more of the following five criteria on a checklist were present (“new gold standard” [NGS]): (1) abnormal clinical findings, (2) abnormal gross character of low-volume lavage (LVL) fluid, (3) positive endometrial cytology, (4) bacterial growth on culture of the LVL pellet, and (5) histologic evidence of inflammation on endometrial biopsy. Kappa (κ) coefficient and percentages were calculated for sensitivity and positive predictive value (PPV) using SAS 9.3 software. Endometritis was diagnosed in 35/44 (79.5%) mares by biopsy. Based on the endometritis checklist, 33/51 (64.7%) mares were positive for endometritis. The character of LVL was 45% sensitive, whereas culture was 22% sensitive, when compared with endometrial biopsy. One percent of neutrophil-to-epithelial cell ratio was the most sensitive cutoff value (93.3%) when using a guarded swab (κ = 0.64). Endometrial biopsy was the most sensitive diagnostic method when compared against the NGS (sensitivity = 86%). Abnormal clinical findings and positive cytology showed moderate agreement with the NGS (κ = 0.41 and κ = 0.38, respectively). These studies demonstrate the importance of combining clinical findings and laboratory data when evaluating mares for endometritis.  相似文献   

7.
The accuracy of bioptome placement for endomyocardial biopsy was evaluated using standard fluoroscopic guidance and compared simultaneously with two-dimensional echocardiography in six healthy subadult grizzly bears (Ursus arctos horribilis). Despite perceived adequate positioning of the bioptome toward the septum when judged using fluoroscopy, only one out of the six placements were actually positioned in the right ventricular apex toward the septum when evaluated using two-dimensional echocardiography. The bioptome was readily relocated to the right ventricular apex/septal location by echocardiography. The forceps were easily visualized at all times and the open cups were readily directed into the desired location for biopsy. Based on a subjective score for tissue quantity from 1 to 4 (poor to excellent), biopsies collected by echocardiographic-guided technique had a mean score of 3.4, while biopsies collected by fluoroscopic-guided technique had a mean score of 1.8. In summary, this study suggests that endomyocardial biopsy locations can be accurately positioned using two-dimensional echocardiography with the advantages of less radiation, lower procedural costs, and direct visualization of the sampling site. Clear definition of endocardial surface as afforded by echocardiography may enhance tissue sample quality and lower potential complications from this procedure.  相似文献   

8.
A percutaneous/transdiaphragmatic core needle biopsy technique was developed in cats to obtain serial biopsies from different locations of the left ventricle, through which morphological and molecular changes within the same individual can be studied to unravel the mechanisms of feline cardiomyopathies. Transmural left ventricular myocardial samples were obtained from 29 anesthetized, healthy, adult cats with ultrasound guidance. An 18G automatic biopsy needle was inserted between the last left rib and the sternum through the diaphragm into the thorax. Biopsies were obtained from the left ventricular wall. In five cats, three single biopsies were taken with 4-week intervals. Autopsy was performed on six cats, of which three cats had serial biopsies. In total, 87 biopsies were obtained without long-term effects on cardiac function or structure. The biopsies caused transient single ventricular premature complexes and mild pericardial effusion without tamponade. Necropsy revealed a minimal amount of fibrous connective tissue in the diaphragm and the heart without any significant microscopic lesions in the adjacent muscle tissue. The high quality biopsy material was suitable for morphological and molecular studies. This minimally invasive, ultrasound-guided cardiac biopsy technique thus allows for the safe collection of serial biopsies to study feline cardiomyopathies in an experimental setting.  相似文献   

9.
Renal biopsy often is required to establish a definitive diagnosis in dogs and cats with renal disease. In this retrospective study, we determined the complications of renal biopsy as well as factors that may be associated with development of complications and procurement of adequate renal biopsy specimens in 283 dogs and 65 cats. Data extracted from medical records at 4 institutions were evaluated using logistic regression. Proteinuria was the most common indication for renal biopsy in dogs. Complications were reported in 13.4 and 18.5% of dogs and cats, respectively. The most common complication was severe hemorrhage; hydronephrosis and death were uncommon. Dogs that developed complications after renal biopsy were more likely to have been 4 to < 7 years of age and > 9 years, to weigh < or = 5 kg, and to have serum creatinine concentrations > 5 mg/dL. The majority of biopsies from both dogs (87.6%) and cats (86.2%) were considered to be of satisfactory quality. Biopsies from dogs were more likely to be of high quality if they were obtained when the patient was under general anesthesia and more likely to contain only renal cortex if they were obtained by surgery. We concluded that renal biopsy is a relatively safe procedure, with a low frequency of severe complications. Hospital practices and patient variables have the potential to impact both the quality of the specimen obtained and the rate of complications.  相似文献   

10.
Serum/plasma fructosamine (SeFa) concentration is a reliable indicator used in human diabetic control. Tests for monitoring the carbohydrate/energy metabolism of (farm) animals are less commonly performed in veterinary laboratories, since most of the reliable determinations, both automated and manual, are relatively expensive. The aim of this study was to develop a precise, money- (and time-) saving automated micro method for measuring SeFa. ELISA microplates (20 microL samples and 200 microL reagents) and an automatic microplate autoreader were used. The classical nitroblue tetrazolium (NBT) stain reagent solution of Johnson et al. (1982) was modified using a SIGMA reagent to render it stable for up to one year. SeFa concentrations measured by the new method in 30 human blood plasma samples were compared with values obtained by the standard (generally used) LaRoche kit procedure. Fifteen cow, 13 dog and 18 chicken plasma samples were assayed by the new automated 'micro' method as well as by the manual test tube 'macro' method commonly used earlier. The modified reagent was applied for both methods. The coefficient of correlation (r) between the results obtained by the two methods was consistently between 0.94 and 0.98 (p < 0.001).  相似文献   

11.
A prospective, clinical trial was conducted using 12 dogs that were presented for intestinal biopsy. Comparisons were made between paired jejunal biopsies collected using a Keyes biopsy punch and a standard scissor excisional technique. There were no differences in speed of collection, diagnostic value of specimens, complication rates, or sample quality. In this study, the Keyes skin punch was found to be safe, rapid, and diagnostic in all animals. Based on results of this study, the use of a Keyes punch instrument can be recommended as an alternative to other open intestinal biopsy methods.  相似文献   

12.
The shot biopsy is a common experimental technique for the collection of samples to investigate muscle tissue characteristics or to determine meat quality features in pigs. Its application seems to be also possible in interdisciplinary research projects investigating animal stress, behaviour, and welfare. The present study on 12 group-housed pigs (age: 12 weeks, weight: 29.3 kg) shows the influence of this wound-causing technique on different humoral and cell-mediated parameters of the immune system at 1, 3, 5, and 9 days after biopsy compared to the initially investigated levels before. An enhancement of the blood sedimentation rate and both the IgG and the cellular immune response in vivo (leukocytes, lymphocytes) as well as in vitro (ConA) was observed. Furthermore, there were signs of a secondary wound infection 5 days after biopsies were taken possibly caused by mutual oral manipulation of the animals. We conclude that the muscle shot biopsy technique can be used on group-housed pigs as a method to investigate muscle physiological characteristics. The technique, however, induces immunological reactions which may interfere with stress-induced immune reactions.  相似文献   

13.
Systolic, mean and diastolic indirect arterial blood pressures were measured on 8 occasions in 6 sows using a tail cuff and an automatic oscillometry apparatus and compared with direct values. The equations for the regression lines gave the intercepts 31.7 (systole), 20.5 (mean) and 14.2 (diastole) with the regression coefficients 0.97, 0.93 and 0.96 and the correlation coefficients 0.91, 0.93 and 0.95. The significance of cuff bladder width and length and of location and fitting on the tail is discussed. The apparatus offered a simple, reliable method for automatic recording of blood pressures during routine anaesthesia in the sow.  相似文献   

14.
Increased hepatic metabolism of estradiol may cause weakened estrous behavior in lactating dairy cows, but this hypothesis must be examined further, especially through diachronic study of the hepatic estradiol-17beta glucuronidation activity of uridine diphosphate (UDP)-glucuronosyltransferases. Therefore, in order to develop a new tool for this purpose, we attempted to conduct biopsy of the livers of dairy cows with the aid of ultrasonography and to measure the UDP-glucuronosyltransferase activities of microsomes of the specimens using in vitro glucuronidation followed by HPLC analysis. We were able to measure the activities of the microsomes prepared from the liver biopsy, and the results seemed reliable. Therefore, this method may become a new tool in clinical studies to detect estradiol-17beta glucuronidation activity.  相似文献   

15.
OBJECTIVES: To compare the volume of hemorrhage, number of lobules, and portal triads available for histologic evaluation, and resultant collateral damage between 5 hepatic biopsy methods: biopsy punch, biopsy needle, ligature method, laparoscopic biopsy forceps, and ultrasonically activated scalpel (UAS). STUDY DESIGN: Experimental, repeated measures, block. ANIMALS: Twelve adult dogs. METHODS: Biopsies were obtained from the periphery and center of the left lateral liver lobe of each dog using each of 5 biopsy techniques. Hemorrhage was quantified and compared between methods and sites. Biopsy samples were evaluated histologically to characterize collateral damage and determine the number of lobules and portal triads sampled. RESULTS: Regardless of technique, liver biopsy resulted in minimal hemorrhage (<2 mL). For peripheral biopsies, UAS was comparable with the ligature method, but caused significantly less hemorrhage than all other methods, whereas for central biopsies, UAS caused significantly less hemorrhage than other methods. Except for the laparoscopic biopsy forceps, UAS caused significantly more collateral damage than other methods. UAS and ligature biopsy methods yielded specimens that had more portal triads per sample than other methods. Eight of 48 biopsy needle samples were inadequate for histologic evaluation, whereas other methods yielded adequate specimens. CONCLUSIONS: All biopsy methods produced minimal hemorrhage and except for needle biopsy yielded adequate tissue samples for histologic evaluation. CLINICAL RELEVANCE: Use of UAS is a reliable, safe alternative technique for liver biopsy and can be used laparoscopically to obtain large tissue samples.  相似文献   

16.
ABSTRACT

1. The objective of this study was to develop a machine vision method for analysing exterior parameters of chicken eggs to automate the stage of primary sorting.

2. The developed algorithm based on predetermined thresholds calculated egg quality indicators, including geometric dimensions, shape index and the mottling grade. The algorithm was implemented with an experimental setup that combined the image-based and the candling methods. A total of 400 egg samples were analysed.

3. Comparison of results of the algorithm with those obtained using the traditional manual method showed that mean value of radii values difference was 0.095 ± 0.058 mm for the sharp and 0.080 ± 0.047 mm for the blunt end of the egg, with standard deviations of 0.58 mm and 0.49 mm, respectively.

4. The correlation coefficient between the shape index values determined by the two methods was 0.93; the standard deviation of absolute differences between corresponding values was 1.05%.

5. The results of mottling grade estimation were compared using F-measure and confusion matrix.

6. The results allow the possibility to perform the assessment of egg exterior quality factors in an automatic mode, independent of the expertise of a grader.  相似文献   

17.
Histopathological striated muscle examination is one of the most important and sensitive tests in diagnosis of muscle and/or nerve diseases. Although muscle biopsy is a relatively easy procedure, it is not frequently performed in small animal practice conditions. Different biopsy techniques have been described in veterinary literature. Punch biopsy of striated muscle appears to be a less invasive and quicker method in comparison with traditional surgical excision technique. Additionally, punch biopsy provide good quality and adequate amount of muscle tissue for diagnostic histopathological evaluation. The aim of this study is to describe striated muscle punch biopsy technique and to encourage use of it under the conditions of small animal practice. The described biopsy method can be specially advantageous in screening of inherited muscle diseases in affected litters or even wider animal population.  相似文献   

18.
Ultrasound-guided biopsy   总被引:1,自引:0,他引:1  
Ultrasound-guided biopsy is a good and feasible technique in dogs. Although we have only used it for biopsy of liver and kidney, it can have further uses. In our use of ultrasound-guided biopsy of kidney and liver, we have found that we can achieve adequate biopsy samples using the Franklin modified Vim-Silverman and Tru Cut biopsy of kidney and liver. The fine-needle biopsies of the liver were adequate for examination of hepatocytes but inadequate to evaluate structure owing to small size of the sample. In contrast, the renal fine-needle samples were both poor in quality and quantity. This technique has the advantages of being noninvasive, quick, and easy, and it can be performed with the patient under local anesthesia. It has an advantage over blind percutaneous biopsy because the needle can be visualized in the organ and the organ scanned after biopsy for possible complications. Another advantage is that, unlike other radiographic biopsy procedures, ionizing radiation is not used for imaging.  相似文献   

19.
Ultrasound-guided biopsy is a good and feasible technique in dogs. Although we have only used it for biopsy of liver and kidney, it can have further uses. In our use of ultrasound-guided biopsy of kidney and liver, we have found that we can achieve adequate biopsy samples using the Franklin modified Vim-Silverman and Tru Cut biopsy of kidney and liver. The fine-needle biopsies of the liver were adequate for examination of hepatocytes but inadequate to evaluate structure owing to small size of the sample. In contrast, the renal fine-needle samples were both poor in quality and quantity. This technique has the advantages of being noninvasive, quick, and easy, and it can be performed with the patient under local anesthesia. It has an advantage over blind percutaneous biopsy because the needle can be visualized in the organ and the organ scanned after biopsy for possible complications. Another advantage is that, unlike other radiographic biopsy procedures, ionizing radiation is not used for imaging.  相似文献   

20.
The aim of the study reported here was to compare complications of lung biopsy in horses and the quality of the lung specimens after biopsy using the manual Tru-Cut biopsy needle (TC) and an automated biopsy needle (ABN). For experiment 1, lung biopsy was performed in 50 horses with one instrument on one side of the thorax, and then with the other instrument on the other side. Postmortem examination was performed in 20 of the 50 horses. Coughing was detected in 10 of 50 horses and epistaxis was observed in 6 of the 50 horses. Endoscopy revealed bleeding into the airways in 16 of 49 horses and in 5 of 49 horses after biopsy with the TC or the ABN, respectively. Use of the ABN induced a significantly smaller amount of bleeding. Pneumothorax was detected by radiography in 1 of 50 horses. Hematoma diameter determined in 7 of 20 horses at postmortem examination, was significantly larger after biopsy with the TC than with the ABN. The quality of the lung specimen was good. In experiment 2, complications after repeated and multiple lung biopsies in 6 horses were evaluated. Moderate epistaxis was observed on 13 of 104 occasions. Bleeding into the airways was detected at endoscopy on 41 of 104 occasions, and pneumothorax was detected during 4 of 104 occasions. Complications such as hematoma at the biopsy site and bleeding into the airways were greater after biopsy with the TC than after use of the ABN. Lung biopsy specimens obtained with the ABN were fairly safe for the animal.  相似文献   