首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.

Objectives

To assess the ability of electrocardiography (ECG) to predict left ventricular hypertrophy (LVH) in the cat and to investigate the prognostic value of selected ECG variables in cats with LVH.

Animals

Fifty-seven privately owned cats: 22 clinically healthy cats and 35 cats with LVH.

Material and methods

This is a clinical cohort study. Echocardiographic diagnosis and surface ECG were available. Electrocardiography analysis included rhythm diagnosis and specific electrocardiographic measurements. In cats with LVH, cause of death and outcome data were recorded and analyzed using Kaplan–Meier curves.

Results

The presence of arrhythmia had sensitivity and specificity of 31% and 100%, respectively, for identifying LVH. Among ECG measurements, duration of QT interval (QT) and QT interval corrected for heart rate (QTc) was statistically different between healthy cats and cats with LVH (p = 0.007). Overall, the most accurate cutoffs to identify LVH were QT > 170 ms (sensitivity and specificity 48.3% and 91%, respectively) and QTc > 188 ms (sensitivity and specificity 62% and 77%, respectively). In healthy cats, the highest QT and QTc values were 180 ms and 200 ms, respectively. Mean survival time was 58 days and indeterminable for cats with QT > 180 ms and QT ≤ 180 ms, respectively (p = 0.042) and 125 days and indeterminable for cats with QTc > 200 ms and QTc ≤ 200 ms, respectively (p = 0.017).

Conclusions

Arrhythmias as well as prolonged QT and QTc are useful ECG parameters in identifying LVH and predicting survival in affected cats.  相似文献   

3.
Two-dimensional (2D) echocardiography is the cornerstone of noninvasive evaluation of the cardiac patient, and often involves estimating left atrial (LA) size. However, 2D echocardiographic methods of estimating LA size have been inadequately described, and most reference intervals are based on M-mode echocardiographic measurements. We determined reference intervals for 4 different 2D echocardiographic methods of estimating LA size in adult (> or =9-month-old) dogs without cardiovascular disease. Thirty-six dogs, placed in right lateral recumbency, were examined by 2D echocardiography. The left atrium was measured at specific time points in the cardiac cycle. Measurement methods were LA diameter in short axis, LA diameter in long axis, LA circumference in short axis, and LA cross-sectional area in short axis. Comparisons of these LA dimensions to appropriate aortic dimensions provided body weight-independent estimates of LA size. We found strong associations of LA dimensions with body weight (r2 = .76-.88). Comparable body weight-independent 2D echocardiographic estimates of LA size in short axis exceeded historical M-mode reference intervals. These data provide echocardiographers with reference intervals for 2D echocardiographic estimates of LA size in adult dogs.  相似文献   

4.

Objectives

Plasma atrial natriuretic peptide (ANP) levels have been reported to be elevated in cats with cardiomyopathy. We investigated the diagnostic accuracy of plasma ANP concentration as an indicator of the severity of cardiomyopathies.

Animals

This study included 78 control cats and 83 cats with various types of cardiomyopathy.

Methods

This was a prospective multicentre study. Control cats were determined to have a normal heart, and diseased cats were diagnosed by echocardiography. Diseased cats were divided into asymptomatic cats without left atrial dilation (LAD), asymptomatic cats with LAD, and cats with heart failure. Plasma C-terminal ANP concentrations were measured using chemiluminescence.

Results

The median plasma ANP concentration in controls was 43.3 (interquartile range, 33.0–56.3) pg/mL. Plasma ANP values were significantly higher in the cardiomyopathic cats with LAD and heart failure, but the values in cats without LAD were comparable to those in control cats. To distinguish cats with cardiomyopathy from controls, a plasma ANP concentration >77.5 pg/mL afforded sensitivity of 66.3% and specificity of 84.6%. Use of plasma ANP concentration >110.9 pg/mL to identify cats with LAD had a sensitivity of 73.6% and specificity of 93.5%. The areas under the receiver-operating characteristic curve were 0.80 and 0.86.

Conclusions

Plasma ANP concentrations were higher in cats with more advanced cardiomyopathy. Although assaying the ANP concentration alone may not help to diagnose cardiac disease, measuring provides additional information that is useful for assessing the severity of cardiomyopathies.  相似文献   

5.
The hypotheses of this prospective study were that (1) left atrial appendage (LAA) blood flow velocities can be recorded in cats with myocardial disease by transthoracic Doppler echocardiography, (2) LA enlargement, LA mechanical dysfunction, and left ventricular (LV) diastolic abnormalities are associated with decreased LAA flow velocities, and (3) low LAA flow velocities predict the appearance of spontaneous echocardiographic contrast in cats with cardiomyopathy. Transthoracic 2-dimensional, M-mode, and Doppler echocardiographic studies were performed in 89 cats with hypertrophic, restrictive, dilated, or unclassified cardiomyopathy or with hyperthyroid heart disease. Maximal LAA flow velocity (LAAmax) was decreased (P < .001) in cats with cardiomyopathy (median, 0.28 m/s; range, 0.08-1.35) compared to normal cats. Associated with decreased LAA flow velocities were increased LA size, decreased LA function, increased severity of LV diastolic dysfunction, and the presence of congestive heart failure. Multivariate logistic regression analysis detected an LAAmax <0.20 m/s as the only independent variable to predict LA spontaneous echocardiographic contrast (odds ratio, 30.1; 95% confidence interval [CI], 4.1 222.3; P < .001). Receiver operating characteristic analysis performed to predict spontaneous echocardiographic contrast indicated an area under the curve of 0.88 (95% CI, 0.80-0.95; P < .001) with sensitivities of 100 and 74% and specificities of 69 and 83% for LAAmax <0.25 and <0.20 m/s, respectively. Thus, low LAA flow velocities identified a subgroup of patients at increased risk of spontaneous echocardiographic contrast and possible thromboembolism. These findings may have important clinical implications for anticoagulation therapy and prognostication in cats with cardiomyopathy.  相似文献   

6.

Background

Hyperadrenocorticism (HAC) is associated with an increased prevalence of hypertension. This study investigated the left ventricular function using two-dimensional speckle-tracking echocardiography (2D-STE) in small breed dogs affected with spontaneous HAC.Age-matched healthy controls (n = 9), dogs with pituitary-dependent hyperadrenocorticism (PDH, n = 10), and dogs with adrenal-dependent hyperadrenocorticism (ADH, n = 9) were included in this study. Conventional echocardiography, global longitudinal and circumferential strain, and strain rate were assessed.

Results

On group-wise comparison, left ventricular free wall (LVFWd) and interventricular septal thickness in diastole (IVSd) were thickest in the ADH group, followed by the PDH and controls (P = 0.014 and P = 0.001, respectively). Neither LVFWd nor IVSd was correlated with systemic blood pressure (P = 0.238 and P = 0.113, respectively). The values of all variables derived from the global strain and strain rate in longitudinal and circumferential directions followed the same pattern: highest in the controls, followed by PDH and then ADH (all P < 0.05, respectively). On multiple regression analyses, global longitudinal strain, global longitudinal strain rate in systole and early diastole, and global circumferential strain all decreased linearly with increased IVSd (all P < 0.05).

Conclusions

Left ventricular hypertrophy (LVH) was more prevalent in the HAC group compared to the control group. Association between hypertension and development of LVH was not identified. Decreased global longitudinal and circumferential strains were associated with increased IVSd. 2D-STE revealed significant decreases in systolic functions that were undetected using conventional echocardiography in the ADH and PDH groups.  相似文献   

7.

Background

False tendons (FTs) are string-like structures in the left ventricle. A FT might produce focal thickening at its insertion region of the left ventricle, which could be mistaken for focal hypertrophic cardiomyopathy.

Objectives

To perform a prospective, echocardiographic follow-up examination of feline FTs and compare the wall thickness at the FT insertion region and a normal region without FTs at both examinations.

Animals

One hundred twenty-eight cats with one or multiple FTs without other cardiac abnormalities or systemic disease.

Methods

Measurements of the interventricular septum at end-diastole at a region with and without FT insertion were performed using two-dimensional echocardiography at both examinations and compared statistically using a Student's t-test.

Results

The follow-up interval ranged from 5 to 110 months (mean, 33 months). Myocardial wall segments with FT insertions were significantly thicker compared with neighboring wall regions in the long axis, but not in the short-axis views obtained. Comparing the wall thickness of follow-up examinations with the initial examination, revealed a significant growth of both FT and non-FT segments. However, differences in growth between the FT region and region without FTs were not statistically different.

Conclusions and clinical importance

Many normal cats have FTs, associated with focal thickening compared with neighboring regions. This thickening can increase over time, proportionate to growth in other (non-FT) segments. The association of such thickening with an FT and the absence of disproportionate growth in this segment over time suggests that these segments are simply thicker related to FT insertion.  相似文献   

8.
9.
10.
11.
IntroductionStaging of myxomatous mitral valve disease (MMVD) requires an echocardiographic examination along with thoracic radiographs. The aims of this study were to calculate mean values for radiographic scores vertebral heart size (VHS), left atrial width (LAWidth), radiographic left atrial dimension (RLAD), and vertebral left atrial size (VLAS) in conventional and grayscale inverted images in healthy dogs and dogs with different stages of MMVD, and to find cutoff values for a stage assignment.AnimalsOne hundred fifty dogs in different stages of MMVD and 50 unaffected dogs were evaluated.MethodsRadiographic scores, echocardiographic left atrium-to-aorta ratio and normalized left ventricular internal dimension at end-diastole, and results of a clinical examination were obtained. Analyses were performed to evaluate the correlation between radiographic scores and echocardiographic values, to determine cutoff values for a radiographic stage assignment, and to compare measurements in conventional and inverted radiographs.ResultsAfter excluding breed-specific higher VHS, the means of VHS, LAWidth, RLAD, and VLAS were similar in the control group and stage B1. All radiographic scores increased in stages B2 and C. The cutoff values identifying heart enlargement, and therefore differentiating stages B1 and B2, were 11.0 for VHS, 1.8 for LAWidth, 2.0 for RLAD, and 2.3 for VLAS. Besides RLAD, scores were similar in conventional and inverted radiographs.ConclusionCutoff values for the different radiographic scores for stage assignment were calculated. Radiographic cardiac scores using either conventional or inverted grayscale could be a tool to differentiate between different stages of MMVD when echocardiography is unavailable.  相似文献   

12.
Background: Ivabradine is a novel negative chronotropic drug used for treatment of ischemic heart disease in people. Little is known about its effects and safety in cats. Hypothesis/Objectives: Ivabradine is not inferior to atenolol with regard to clinical tolerance, heart rate (HR) reduction, and effects on cardiac function in healthy, lightly sedated cats. Animals: Ten healthy laboratory cats. Methods: Physical examination, systolic blood pressure measurement, and transthoracic echocardiography were performed in all cats at baseline and after oral administration (4 weeks each) of ivabradine (0.3 mg/kg q12h) and atenolol (6.25 mg/cat q12h; 1.0–1.7 mg/kg) in a prospective, double‐blind, randomized, active‐control, fully crossed study. A priori noninferiority margins for the effects of ivabradine compared with atenolol were set at 50% (f= 0.5) based on predicted clinical relevance, observer measurement variability, and in agreement with FDA guidelines. Variables were compared by use of 2‐way repeated measures ANOVA. Results: Ivabradine was clinically well tolerated with no adverse events observed. HR (ivabradine, P < .001; atenolol, P < .001; ivabradine versus atenolol, P= .721) and rate‐pressure product (RPP) (ivabradine, P < .001; atenolol, P= .001; ivabradine versus atenolol, P= .847) were not different between treatments. At the dosages used, ivabradine demonstrated more favorable effects than atenolol on echocardiographic indices of left ventricular (LV) systolic and diastolic function and left atrial performance. Conclusions and Clinical Importance: Ivabradine is not inferior to atenolol with regard to effects on HR, RPP, LV function, left atrial performance, and clinical tolerance. Clinical studies in cats with hypertrophic cardiomyopathy are needed to validate these findings.  相似文献   

13.
Hypertrophic cardiomyopathy (HCM) in cats is characterized by concentric left ventricular (LV) hypertrophy and both diastolic and systolic dysfunction. Although impaired cardiac function detected by tissue Doppler imaging (TDI) in cats with HCM was previously reported, reference ranges of TDI in normal cats and cats with HCM have been reported as widely variable. Two-dimensional speckle tracking echocardiography (STE) was useful for assessment of cardiac function in human patients with HCM, but clinical utility was not known in cats. The aim of this study was to assess global and segmental LV myocardial function using STE in cats with HCM whose TDI variables were within the reference range. A total of 35 cats of different breeds were enrolled in this study. The HCM group (n=22) was cats diagnosed as HCM without left atrial enlargement and with normal TDI measurements. HCM cats were further divided into a segmental hypertrophy (S-HCM) group and a diffuse hypertrophy (D-HCM) group. The control group consisted of 13 clinically healthy cats. No cats in any group showed any clinical symptoms. Conventional echocardiography, TDI, and global and segmental STE indices were evaluated and compared between groups. Only the longitudinal strain rate during early diastole was significantly decreased in both HCM groups, even in all segments including those without hypertrophy in S-HCM group. This study suggests that STE parameters are the more sensitive variables compared with conventional TDI parameters to detect early myocardial diastolic dysfunction in cats with HCM.  相似文献   

14.
Background: Real‐time 3‐dimensional echocardiography (RT3D) is a recent technique based on volumetric scanning, eliminating the need for geometric modeling of the cardiac chambers and minimizing the errors caused by foreshortened views. Hypothesis: Estimations of left ventricular (LV) end‐diastolic (EDV) and end‐systolic volume (ESV), and left atrial (LA) size, differ depending on the echocardiographic technique of estimation. Animals: Fifty‐one dogs with acquired heart disease and 34 healthy control dogs. Methods: Prospective observational study by M‐mode (Teichholz method), Simpson's modified 2‐dimensional (2D) method, and RT3D methods for estimation of LV volumes. LA size was evaluated by 2D and RT3D methods. Results: RT3D showed good agreement with 2D for EDV and ESV, whereas Teichholz method overestimated LV volumes in comparison with the other 2 methods by approximately a factor 2. There were no statistically significant differences among the 3 methods in estimating ejection fraction. Comparison between RT3D assessment of LA end‐systolic volume per kilogram (LAs/kg) and LA to aortic ratio (LA/Ao) measured by 2D relative to each other showed that the RT3D method underestimated LAs/kg at lower values, and overestimated it at higher values. The difference between methods increased with increasing LA size. Conclusions and Clinical Importance: There was good agreement between RT3D and 2D methods of estimating EDV and ESV, whereas the Teichholz method overestimated LV volumes by approximately a factor 2. In comparison with RT3D, LA/Ao underestimated LA size, especially when LA was enlarged.  相似文献   

15.
BACKGROUND: Left ventricular (LV) torsional deformation plays an important role in myocardial function. However, it has never been assessed in the awake dog, because magnetic resonance imaging and sonomicrometry have been the only methods available so far. HYPOTHESIS: Two dimensional speckle tracking echocardiography (STE), a new ultrasound imaging technique, provides a repeatable and reproducible noninvasive assessment of systolic LV wringing motion in the awake dog. ANIMALS: Six healthy dogs were used to determine the repeatability and reproducibility of STE variables (study 1). These variables also were prospectively assessed in a population of 35 healthy dogs (study 2). METHODS: Peak LV basal and apical systolic rotations were measured by STE from right parasternal short-axis views using automatic frame-to-frame tracking of gray-scale speckle patterns. Systolic LV torsion (LVtor, degrees ) was defined as apical rotation relative to the base. RESULTS: All within-day and between-day coefficients of variation were <20% (6.8-18.0%). Amplitude of apical systolic rotation was significantly higher (P < .001) than the basal value (5.4 +/- 3.2 degrees and -3.1 +/- 1.3 degrees , respectively). Global LVtor was significantly correlated with systolic longitudinal LV myocardial velocity gradient assessed by tissue Doppler (P < .05), but not with either systolic radial LV myocardial velocity gradient or the ratio of early mitral inflow velocity to early mitral annular velocity (Em/Ea). CONCLUSIONS AND CLINICAL IMPORTANCE: Speckle tracking echocardiography is a repeatable and reproducible method for assessing systolic LV torsional deformation. The combination of these new STE indices with tissue Doppler variables could provide a new approach for quantifying canine LV systolic function.  相似文献   

16.
17.
18.

Introduction

We sought to determine the feasibility, measurement variability, and within-day repeatability of tricuspid annular plane systolic excursion (TAPSE) measured by two-dimensional echocardiography (2D TAPSE), generate reference intervals for 2D TAPSE, assess agreement and correlation between 2D TAPSE and the conventional TAPSE measured by M-mode echocardiography (MM TAPSE), and to assess the ability of 2D TAPSE to track a drug-induced decrease in right ventricular (RV) function compared with MM TAPSE.

Animals

Seventy healthy privately owned dogs of varying bodyweight.

Methods

All dogs underwent a single echocardiogram to quantify RV function by both TAPSE methods. Ten dogs underwent a second echocardiogram 2–3 h after the first to assess within-day repeatability, and 20 different dogs underwent a second echocardiogram 3-h after atenolol (1 mg/kg per os (PO)). Intraobserver and interobserver measurement variabilities were assessed in 12 randomly selected studies using coefficients of variation. Statistical relationships between 2D TAPSE and bodyweight, gender, heart rate, and age were explored.

Results

2D TAPSE could be measured in all dogs. Coefficients of variation for repeatability and measurement variability were low (≤12%). Bodyweight-dependent reference intervals for 2D TAPSE were generated using allometric scaling. TAPSE methods were strongly correlated (r = 0.72; p<0.0001) but 2D TAPSE measured consistently less than MM TAPSE (?1.6 [2.2] mm) when analyzed by Bland–Altman's method. Both TAPSE methods were significantly (p≤0.014) reduced after atenolol but percent decrease in 2D TAPSE (?16.2 [9.3]%) was significantly greater (p=0.03) than MM TAPSE (?7.5 [13.8]%).

Conclusions

Two-dimensional echocardiography TAPSE appears well suited for clinical assessment of RV function. The TAPSE methods should not be used interchangeably.  相似文献   

19.
Finding an appropriate location for perpendicular positioning of the X-ray machine to produce zero lateromedial (ZLM) and zero dorsopalmar (ZDP) carpal images (views) and finding an acceptable range of rotational variations for measurement of carpal conformational parameters were two major challenges identified during field radiography of equine forelimbs. 16 cadaver forelimbs transacted at antebrachial midshaft from 10 horses (aged 9.13 ± 4.59 years) were axially mounted into a custom-built frame, and the radiographic machine and plate were perpendicularly aligned with the limb. Each limb was then radiographed at 2.5° interval of vertical rotation of the machine until ZLM and ZDP images were acquired, and at 24 other postural and rotational positions from ZLM and ZDP at 5° interval for comparison of measurements with the standardized ZLM and ZDP images. ZLM radiographs were produced at a mean vertical projection angle (VPA) of 9.84 ± 3.47° palmarolateral–dorsomedial oblique (PaL-DMO), while ZDP was acquired at VPA of 6.41 ± 2.73° dorsolateral–palmaromedial oblique (DL-PaMO). Changes in limbs’ postural tilts, vertical plate rotations (VPR) and horizontal beam rotations (HBR) had no effect on the quality of the radiographs and on carpal measurements, while vertical beam rotation (VBR) of X-ray beam produced significant changes on the quality of radiographs and on measurements of carpal parameters. It is recommended that field radiographs of equine forelimbs intended for carpal measurement be obtained within a proposed range of VPA of 2.5° to 12.5° PaL-DMO for ZLM and 2.5° to 10° DL-PaMO for ZDP in order to minimize potential errors attributable to vertical rotational movements.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏