1.
A continuous glucose monitoring system (CGMS) was evaluated in 14 cats with naturally occurring diabetes mellitus. The device measures interstitial fluid glucose continuously, by means of a sensor placed in the subcutaneous tissue. All cats tolerated the device well and a trace was obtained on 15/16 occasions. There was good correlation between the CGMS values and blood glucose concentration measured using a glucometer (r=0.932, P<0.01). Limitations to the use of the CGMS are its working glucose range of 2.2-22.2 mmol/l (40-400 mg/dl) and the need for calibration with a blood glucose measurement at least every 12 h. When compared to a traditional blood glucose curve, the CGMS is minimally invasive, reduces the number of venepunctures necessary to assess the kinetics of insulin therapy in a patient and provides a truly continuous glucose curve.  相似文献   

2.
The generation of a blood glucose curve is important for assessing the response to insulin therapy in diabetic dogs. Disadvantages of this technique include patient discomfort and the potential for missing transient hypo- or hyperglycaemic episodes. The aim of the current study was to evaluate a continuous glucose monitoring system (CGMS) for use in diabetic dogs. Interstitial fluid glucose concentrations were recorded in 10 diabetic dogs, every five minutes for up to 48 hours, using a subcutaneous sensor attached to the CGMS device. Blood glucose concentrations were measured simultaneously using a glucometer. The correlation between interstitial fluid and blood glucose values was 0.81 (P < 0.01). The largest discrepancies between the two sets of data were seen during the one- to three-hour period following feeding, suggesting that postprandial hyperglycaemia might not be reflected in the interstitial fluid. The authors conclude that the CGMS is a potentially valuable tool in the management of canine diabetic patients.  相似文献   

3.
OBJECTIVE: To evaluate a continuous glucose monitoring system (CGMS) for use in dogs, cats, and horses. DESIGN: Prospective clinical study. Animals-7 horses, 3 cats, and 4 dogs that were clinically normal and 1 horse, 2 cats, and 3 dogs with diabetes mellitus. PROCEDURE: Interstitial glucose concentrations were monitored and recorded every 5 minutes by use of a CGMS. Interstitial glucose concentrations were compared with whole blood glucose concentrations as determined by a point-of-care glucose meter. Interstitial glucose concentrations were also monitored in 2 clinically normal horses after oral and i.v. administration of glucose. RESULTS: There was a positive correlation between interstitial and whole blood glucose concentrations for clinically normal dogs, cats, and horses and those with diabetes mellitus. Events such as feeding, glucose or insulin administration, restraint, and transport to the clinic were recorded by the owner or clinician and could be identified on the graph and associated with time of occurrence. CONCLUSIONS AND CLINICAL RELEVANCE: Our data indicate that use of CGMS is valid for dogs, cats, and horses. This system alleviated the need for multiple blood samples and the stress associated with obtaining those samples. Because hospitalization was not required, information obtained from the CGMS provided a more accurate assessment of the animal's glucose concentrations for an extended period, compared with measurement of blood glucose concentrations. Use of the CGMS will promote the diagnostic and research potential of serial glucose monitoring.  相似文献   

4.
Objective – (1) To determine the ability of a continuous interstitial glucose monitoring system (CGMS) to accurately estimate blood glucose (BG) in dogs and cats with diabetic ketoacidosis. (2) To determine the effect of perfusion, hydration, body condition score, severity of ketosis, and frequency of calibration on the accuracy of the CGMS. Design – Prospective study. Setting – University Teaching Hospital. Animals – Thirteen dogs and 11 cats diagnosed with diabetic ketoacidosis were enrolled in the study within 24 hours of presentation. Interventions – Once BG dropped below 22.2 mmol/L (400 mg/dL), a sterile flexible glucose sensor was placed aseptically in the interstitial space and attached to the continuous glucose monitoring device for estimation of the interstitial glucose every 5 minutes. Measurements and Main Results – BG measurements were taken with a portable BG meter every 2–4 hours at the discretion of the primary clinician and compared with CGMS glucose measurements. The CGMS estimates of BG and BG measured on the glucometer were strongly associated regardless of calibration frequency (calibration every 8 h: r=0.86, P<0.001; calibration every 12 h: r=0.85, P<0.001). Evaluation of this data using both the Clarke and Consensus error grids showed that 96.7% and 99% of the CGMS readings, respectively, were deemed clinically acceptable (Zones A and B errors). Interpatient variability in the accuracy of the CGMS glucose measurements was found but was not associated with body condition, perfusion, or degree of ketosis. A weak association between hydration status of the patient as assessed with the visual analog scale and absolute percent error (Spearman's rank correlation, ρ=?0.079, 95% CI=?0.15 to ?0.01, P=0.03) was found, with the device being more accurate in the more hydrated patients. Conclusions – The CGMS provides clinically accurate estimates of BG in patients with diabetic ketoacidosis.  相似文献   

5.
Background: The Guardian REAL‐Time is a continuous glucose‐monitoring system (CGMS) recently developed to provide instantaneous interstitial glucose concentrations; the system does not require a monitor being fixed to the animal. Hypothesis: The CGMS provides accurate and reproducible real‐time readings of glucose concentration in cats. Animals: Thirty‐two diabetic cats, 2 cats with suspected insulinoma, and 5 healthy cats. Methods: Prospective, observational study. CGMS accuracy was compared with a reference glucose meter at normal, high, and low blood glucose concentrations using error grid analysis. Reading variability of 2 simultaneously used CGMS was determined in diabetic cats by calculating correlation and percentage of concordance of paired data at different glycemic ranges. The time interval between increasing glycemia and a rise in interstitial fluid glucose measured by the CGMS was assessed in healthy cats receiving glucose IV; the time point of maximal increase in interstitial glucose concentrations was calculated. Results: The CGMS was 100, 96.1, and 91.0% accurate at normal, high, and low blood glucose concentrations. Measurements deviated from reference by ?12.7 ± 70.5 mg/dL at normal, ?12.1 ± 141.5 mg/dL at high, and ?1.9 ± 40.9 mg/dL at low glucose concentrations. Overall, paired CGMS readings correlated significantly (r= 0.95, P < .0001) and concordance was 95.7%. The median delay after IV administration of glucose to an increase in interstitial glucose was 11.4 minutes (range: 8.8–19.7 minutes). Conclusions and Clinical Importance: Although some readings substantially deviated from reference values, the CGMS yields reproducible results, is clinically accurate in cats with hyperglycemia and euglycemia, and is slightly less accurate if blood glucose concentrations are low. Rapidly increasing interstitial glucose after a glycemic rise suggests that the CGMS is suitable for real‐time measurement under clinical conditions.  相似文献   

6.
A subcutaneous continuous glucose monitoring system (GlucoDay; Menarini Diagnostics) based on microdialysis was investigated for its clinical applicability in veterinary medicine. Ten diabetic dogs, referred as clinically stable, were equipped with this system and sent home for a maximum observation period of 48 hours. Time of insulin administration, feeding and other events were written in a diary and plotted afterwards in the glucose graph. Implantation of the microdialysis fibre, acceptance of the device and evaluation of individual canine glucose profiles were without complication. Based on the monitoring data, recommended treatment adjustments were given to the referring veterinarians in all 10 dogs; hypoglycaemic or prolonged hyperglycaemic episodes were detected in six dogs.  相似文献   

7.
Thrombelastograph analyzers are point-of-care hemostatic analyzers that provide global assessment of the hemostatic process. Thrombelastography (TEG) detects and provides a continuous recording of the changes in the viscoelastic properties of whole blood from initial clot formation through fibinolysis. TEG has been validated for use in dogs, horses, and cats. Hemostasis research using TEG has focused on test validation, alterations of TEG tracings in animals with naturally occurring diseases, and the use of TEG for monitoring various therapeutic modalities. This article reviews TEG methodology and terminology, including potential sources of preanalytical and analytical errors, the correlation between TEG and other routine hemostatic assays, and current clinical applications of TEG, with emphasis on veterinary medical practice. Data suggest that TEG may be a sensitive and useful adjunctive tool for evaluating an animal with an underlying coagulopathy, including hypercoagulability and hypocoagulability. Additional prospective studies are needed to (1) correlate TEG tracing patterns with a clinical predisposition for bleeding or thrombosis in various disease states and (2) determine whether monitoring and treating hemostatic disorders based on TEG tracings improve clinical outcome.  相似文献   

8.
Recently a new method for capillary blood sampling from the ears of dogs and cats was described, which allows the measurement of glucose concentration by means of portable glucose meters. The authors of this report evaluated the suitability of this method for use by pet owners and the potential technical problems. The owners of seven healthy dogs and seven healthy cats were asked to perform two glucose curves (measuring blood glucose concentration every 2 hours for a total of 12 hours). All dog owners and three cat owners were able to perform a reliable blood glucose curve. The most frequently encountered problems were inadequate formation of a blood drop due to excessive digital pressure on the pinna, repeatedly depressing the plunger of the lancet device instead of allowing the negative pressure to slowly build up, and failure to fill the test strip up to the mark. The authors conclude that these steps of the procedure need to be stressed during technique demonstration and that home monitoring of blood glucose concentrations may serve as a new tool in the management of diabetic dogs and cats.  相似文献   

9.
OBJECTIVE: To establish a reliable diagnostic tool for septic peritonitis in dogs and cats using pH, bicarbonate, lactate, and glucose concentrations in peritoneal fluid and venous blood. STUDY DESIGN: Prospective clinical study. ANIMALS: Eighteen dogs and 12 cats with peritoneal effusion. METHODS: pH, bicarbonate, electrolyte, lactate, and glucose concentrations were measured on 1- to 2-mL samples of venous blood and peritoneal fluid collected at admission. The concentration difference between blood and peritoneal fluid for pH, bicarbonate, glucose, and lactate concentrations were calculated by subtracting the peritoneal fluid concentration from the blood concentration. Peritoneal fluid was submitted for cytologic examination and bacterial culture. Peritonitis was classified as septic or nonseptic based on cytology and bacterial culture results. RESULTS: In dogs, with septic effusion, peritoneal fluid glucose concentration was always lower than the blood glucose concentration. A blood-to-fluid glucose (BFG) difference > 20 mg/dL was 100% sensitive and 100% specific for the diagnosis of septic peritoneal effusion in dogs. In 7 dogs in which it was evaluated, a blood-to-fluid lactate (BFL) difference < -2.0 mmol/L was also 100% sensitive and specific for a diagnosis of septic peritoneal effusion. In cats, the BFG difference was 86% sensitive and 100% specific for a diagnosis of septic peritonitis. In dogs and cats, the BFG difference was more accurate for a diagnosis of septic peritonitis than peritoneal fluid glucose concentration alone. CONCLUSIONS: A concentration difference > 20 mg/dL between blood and peritoneal fluid glucose concentration provides a rapid and reliable means to differentiate a septic peritoneal effusion from a nonseptic peritoneal effusion in dogs and cats. CLINICAL RELEVANCE: The difference between blood and peritoneal fluid glucose concentrations should be used as a more reliable diagnostic indicator of septic peritoneal effusion than peritoneal fluid glucose concentration alone.  相似文献   

10.
Objective – To describe the use of continuous electroencephalographic (EEG) monitoring for management of status epilepticus (SE) in dogs and cats. Design – Retrospective study. Setting – University teaching hospital. Animals – Ten patients (7 dogs, 3 cats) with SE of differing etiology (idiopathic epilepsy, n=3; toxicity, n=4; meningoencephalitis, n=2; undefined, n=1). Interventions – The EEG was recorded continuously from 5 stainless‐steel needle electrodes inserted SC. Animals were treated with diazepam and phenobarbital followed by either propofol (n=3) or pentobarbital (n=7) as a continuous rate of infusion. Measurements and Main Results – Clinical seizures stopped after induction of anesthesia in each animal. The EEG, however, still showed distinct epileptiform patterns (spikes, polyspikes) in all animals. Paroxysms were suppressed by increasing the infusion rate of either pentobarbital or propofol. A burst‐suppression pattern was achieved in 5 animals. EEG epileptiform activity reappeared in 4 animals when attempting to taper the dose after >6 hours of anesthesia. This was interpreted as ongoing EEG seizure activity and an increased risk for clinical seizures, and the anesthetic dosage was adjusted accordingly. Conclusion – Continuous EEG monitoring appears to be a useful tool for therapeutic monitoring of SE in dogs and cats. It allows the detection of EEG seizures without the appearance of clinical seizures. Further investigations with blinded investigators and homogeneous animal groups to define therapeutic endpoints are warranted.  相似文献   

11.
Two new methods for collection of capillary blood from the ear of dogs and cats for the measurement of blood glucose concentration using portable blood glucose meters (PBGMs) are described. The first method uses a lancing device after pre-warming the ear, while the second employs a vacuum lancing device. Both methods generated blood drops of adequate size, although the latter method was faster and easier to perform. Accuracy of the two PBGMs was evaluated clinically and statistically. Although assessment of statistical accuracy revealed differences between the PBGMs and the reference method, all of the PBGM readings were within clinically acceptable ranges. Measurement of capillary blood glucose concentration is easy to perform, inexpensive and fast. It may be used by owners to determine blood glucose concentrations at home, and could serve as a new tool for monitoring diabetic dogs and cats.  相似文献   

12.
AIMS: To survey current anaesthesia practices for dogs and cats in small and mixed animal practices in New Zealand in order to improve anaesthesia education.

METHODS: A questionnaire was sent to 440 small and mixed animal practices, including questions regarding the type of practice, preanaesthetic examination, anaesthetic drugs and management, anaesthetic machines, monitoring and topics of interest for continuing professional development.

RESULTS: Responses were obtained from 113/440 (26%) practices, with 78 (69%) respondents from small and 35 (31%) from mixed animal practices. A preanaesthetic physical examination was carried out by >95% of respondents and premedication was usually given to dogs (112/113; 99%) and cats (95/113; 85%). Acepromazine was the preferred sedative for dogs and cats, with morphine or buprenorphine. Propofol and alfaxalone were the preferred induction agents, and isoflurane was preferred for maintenance in both dogs and cats. A venous catheter was usually placed for anaesthesia in dogs (59/113; 52%), but less so in cats (39/113; 35%). Perioperative fluid was administered at 10?mL/kg/hour by 62/110 (56%) respondents. Intubation was usually used for anaesthesia in dogs (111/112; 99%), and cats (87/112; 78%). Almost 40% of respondents usually administered supplementary oxygen if patients were not intubated. Local analgesia was used by 69/111 (88%) respondents sometimes or always if applicable. Morphine or buprenorphine, and meloxicam were common choices for post-operative analgesia after neuter surgery in dogs and cats. A semiclosed (non-rebreathing) system was used in animals weighing <10?kg, and a Mapleson E or F non-rebreathing circuit was used by 66/109 (61%) practices. Only 15/111 (14%) practices had a ventilator in their practice. A dedicated anaesthetist was usually used by 104/113 (92%) practices, and apnoea alarms, pulse oximeters, thermometers and oesophageal stethoscopes were the main monitoring devices available in practices. Loco-regional block, pain management, and anaesthetic drugs were the main topics of interest for continuing education.

CONCLUSIONS AND CLINICAL RELEVANCE: Responses by the veterinarians taking part in this survey indicated that they had a reasonably good standard of anaesthetic practice. A physical examination was carried out preanaesthesia, and premedication including analgesia was routinely administered to most patients. A dedicated anaesthetist usually monitored patients and most respondents reported they had access to basic anaesthetic monitoring equipment. Areas where changes could lead to improved anaesthetic practice were increased use of I/V catheterisation, endotracheal intubation, and supplementary oxygen, and reduced I/V fluid rates.  相似文献   

13.
OBJECTIVE: To characterize interstitial lung diseases (ILDs) and evaluate use of keyhole lung biopsy for diagnosis of ILDs in dogs and cats. DESIGN: Retrospective study. ANIMALS: 11 dogs and 2 cats. PROCEDURE: Medical records of dogs and cats undergoing keyhole lung biopsy to confirm ILDs were reviewed. Signalment, clinical signs, results of thoracic radiography and other respiratory diagnostic tests, postoperative complications, and patient outcome were analyzed. RESULTS: Clinical respiratory signs included cough, tachypnea, exercise intolerance, and hemoptysis. Thoracic radiographic abnormalities included interstitial, alveolar, and bronchointerstitial patterns and multiple discrete pulmonary nodules. Lung biopsy and histologic examination revealed interstitial pulmonary fibrosis, bronchiolitis obliterans with organizing pneumonia, or unclassified lesions. Outcome after biopsy included no response to treatment, euthanasia, partial or complete remission while receiving medication, and cure. CONCLUSIONS AND CLINICAL RELEVANCE: Recognition and classification of ILDs in dogs and cats are likely to be important in guiding appropriate treatment and providing accurate prognostic information. Ancillary respiratory diagnostic tests are beneficial in ruling out infectious and neoplastic disorders that may mimic ILDs; however, their present use in the diagnosis of ILDs is limited. Results suggest that keyhole lung biopsy is an effective means for obtaining a specimen for histologic diagnosis in dogs and cats with ILDs.  相似文献   

14.
The use of portable blood glucose meters (PBGM) has become common in veterinary medicine as a rapid means of monitoring animals' blood glucose in a variety of medical conditions. These hand-held monitors allow for diagnostic and therapeutic decisions to be made quickly and relatively inexpensively using only a small amount of blood. Both in conditions resulting in hyperglycemia, such as diabetes mellitus, and in those resulting in hypoglycemia, such as sepsis or the presence of an insulinoma, veterinarians have come to rely on PBGM to provide critical information on the status of their animal patients. In particular, PBGM are frequently used to measure individual blood glucose values in an animal over a period to create a blood glucose curve when evaluating the effectiveness of insulin therapy in diabetic dogs and cats.  相似文献   

15.
Use of an externally applied, noninvasive skin-stretching device in 24 dogs and cats is described. The device uses adhesive-coated pads that are applied to the skin of an animal; pads are positioned on opposite sides of a surgical site and are connected by means of adjustable elastic cables. The cables maintain continuous tension, and cable tension is adjusted and progressively increased at intervals of 6 to 8 hours to promote skin recruitment (stretching), using the cutaneous viscoelastic properties of mechanical creep and stress relaxation. Consequently, skin adjacent and distant to the surgical site can be recruited to facilitate wound closure, typically within 72 to 96 hours after application of the device. The skin-stretching device has been used effectively in dogs and cats to stretch skin prior to elective surgical procedures, stretch skin during management of open wounds prior to suturing, and alleviate incisional tension after surgery.  相似文献   

16.
Pulse oximetry holds the promise of wide application for monitoring and assessing pulmonary function in small animal patients. Although the saturation as read by pulse oximetry (SpO2) has previously been shown to be accurate in healthy dogs, its accuracy and usefulness have not been demonstrated in critical small animal patients. The present study assessed the accuracy and usefulness of a pulse oximeter (Ohmeda Biox 3740, Ohmeda, Louisville, CO) in a small animal intensive care unit. The instrument yielded readings in 48 of 51 attempts in 33 animals (25 dogs, 8 cats). Criteria were developed to reject spurious readings; when these criteria were applied, the actual calculated SaO2 differed from the SpO2 by O.26 +2.2%, with a correlation of 0.87 (p<0.0001). The 95% confidence interval was +4.4%, comparable to the accepted level in humans. No ill effects from SpO2 were apparent in the patients, and the instrument was useful in monitoring the progress of critical animals. However, uncritical use of the oximeter could have led to gross patient mismanagement, as SpO2 readings as much as 29% different from SaO2 were sometimes obtained.  相似文献   

17.
OBJECTIVE: To determine the clinical usefulness of cardiac event recording in evaluating dogs and cats with unexplained syncope, episodic collapse, or intermittent weakness. DESIGN: Retrospective study. ANIMALS: 58 dogs and 2 cats. PROCEDURE: Medical records and electrocardiographic rhythm strips obtained by cardiac event recordings were reviewed. Cardiac rhythm data from the event recordings were classified as diagnostic or nondiagnostic. Diagnostic yield was calculated by dividing the number of animals for which cardiac event recording was diagnostic by the total number of animals undergoing cardiac event recording. RESULTS: For 51 animals, cardiac event recording was classified as diagnostic; therefore, overall diagnostic yield was 85%. Diagnostic yield was lower for animals without underlying structural heart disease (75.5%) than for animals with structural heart disease (95.6%). A specific arrhythmia was identified as the cause of clinical signs in 18 of the 51 (35%) animals for which cardiac event recording was diagnostic. Cardiac arrhythmia was definitively excluded as the cause of clinical signs in the remaining 33 (65%) animals in which cardiac event recording was diagnostic. CONCLUSIONS AND CLINICAL RELEVANCE: Results indicate that cardiac event recording had a high diagnostic yield in dogs and cats examined because of unexplained syncope, episodic collapse, or transient weakness and ataxia, regardless of whether animals did or did not have an underlying structural heart disease. Diagnostic yield of cardiac event recording was higher than that reported previously for Holter monitoring.  相似文献   

18.
A survey of anaesthesia in small animal practice: AVA/BSAVA report   总被引:3,自引:0,他引:3  
Over 150 veterinary surgeons from 53 small animal practices collaborated in a prospective survey of anaesthetic accidents and emergencies by recording all anaesthetics administered and detailing the problems they encountered. From these records it is estimated that 1 in 679 of the healthy dogs and cats died primarily as a result of anaesthesia; many of these deaths apparently occurred at a time when the animal was not under close observation. Anaesthetics involving the use of xylazine seemed to result in an exceptionally high mortality rate. Complications following endotracheal intubation appeared to be associated with several deaths in cats. The death rate in cats and dogs with pathological but not immediately life-threatening conditions was estimated to be 1 in 31. There was no evidence to suggest that some breeds (with the possible exception of the Pekingese) were more likely than others to die under anaesthesia.  相似文献   

19.
Brachial plexus trauma is a common clinical entity in small animal practice and prognostic indicators are essential early in the course of the disease. Magnetic stimulation of the radial nerve and consequent recording of the magnetic motor evoked potential (MMEP) was examined in 36 dogs and 17 cats with unilateral brachial plexus trauma.Absence of deep pain perception (DPP), ipsilateral loss of panniculus reflex, partial Horner’s syndrome and a poor response to MMEP were related to the clinical outcome in 29 of the dogs and 13 of the cats. For all animals, a significant difference was found in MMEP between the normal and the affected limb. Absence of DPP and unilateral loss of the panniculus reflex were indicative of an unsuccessful outcome in dogs. Additionally, the inability to evoke a MMEP was associated with an unsuccessful outcome in all animals. It was concluded that magnetic stimulation of the radial nerve in dogs and cats with brachial plexus trauma may provide an additional diagnostic and prognostic tool.  相似文献   

20.
Practical management of obesity in dogs and cats   总被引:1,自引:0,他引:1  
Obesity is the most common form of malnutrition encountered in small animal practice in the western world. In a survey of cats presented to the author's clinic, 40 per cent were overweight or obese; the incidence of obesity was highlighted in neutered cats, those that were kept indoors and those over 36 months of age. A number of clinical conditions of dogs and cats can be associated with obesity, therefore its prevention and control represents an important challenge for the small animal veterinarian and its success is largely dependent on effective client education. Treatment of obesity involves a suitable diet formulation and continual patient monitoring to maintain the owner's enthusiasm and cooperation. Commercial low calorie diets provide an effective and convenient means of weight loss in obese dogs and cats.  相似文献   