首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The purpose of this study was to (1) establish a technique for ultrasound-guided trans-splenic portal scintigraphy (TSPS) using 99mTcO4(-), (2) evaluate portal vein morphology, (3) compare the radiation exposures for TSPS vs. per-rectal portal scintigraphy (PRPS), and (4) compare the quality of numerical data from the TSPS vs. PRPS. Eight juvenile dogs underwent PRPS and TSPS (minimum of 48h between studies) after initial screening tests. PRPS was done according to established protocol using 425 +/- 36MBq (mean +/- SD) of 99mTcO4(-). TSPS was done with the dogs in right lateral recumbency over the gamma camera. 99mTcO4(-) (57 +/- 13.9 MBq) was injected into the spleen 1-2s following initiation of the dynamic acquisition. The frame rate was 4 frames/s for 5 min. There was significantly lower radioactivity of 99mTcO4(-) given and significantly higher total counts recorded in the liver and heart during the TSPS compared with PRPS. The total counts for the TSPS and PRPS were 7120 +/- 4386 and 830 +/- 523, respectively. Percent absorption from the spleen was 52.5 +/- 19.1% compared with 9.2 +/- 5.7% for the colon. Calculated transit time for the TSPS studies was 7 +/- 2.3s. In TSPS studies, the splenic and portal veins were clearly identified. Radiation exposure levels of the dogs were significantly lower following TSPS than after PRPS. TSPS appears superior to PRPS as a method to image the portal venous system representing a valid alternative diagnostic test for animals with suspected portosystemic shunts.  相似文献   

2.
Ultrasound-guided percutaneous trans-splenic portal scintigraphy (TSPS) using 99mTcO4(-) has been used to image the portal venous system in normal dogs. Compared with per-rectal portal scintigraphy, it provides higher count density, consistent nuclear venograms of the splenic and portal vein, and significantly decreased radiation exposures. This paper describes the use of TSPS for the diagnosis of portosystemic shunts in 28 dogs. TSPS was performed injecting 70 +/- 28 MBq of 99mTcO4(-) (mean +/- SD) into the splenic parenchyma with ultrasound guidance. A dynamic acquisition at a frame rate of four frames/s for 5 min was initiated after placement of the needle and approximately 2s prior to injection. All dogs had diagnoses confirmed via exploratory laparotomy or ultrasonographic identification of the shunting vessel(s). Three studies (10.7%) were nondiagnostic because of intraperitoneal rather than intrasplenic injection of the radionuclide. Three pathways were recognized on the scintigraphic images: (1) portoazygos shunts--the 99mTcO4(-) bolus traveled dorsally, running parallel to the spine and entering the heart craniodorsally; (2) single portocaval or splenocaval shunts--the 99mTcO4(-) bolus ran from the area of the portal vein/splenic vein junction in a linear fashion toward the caudal vena cava entering the heart caudally; (3) internal thoracic shunt-the 99mTcO4 bolus traveled ventrally along the thorax and abdomen entering the cranial aspect of the heart. Single and multiple shunts were easily distinguished. There were no distinguishing features between single intra and extrahepatic portocaval shunts.  相似文献   

3.
We describe the scintigraphic patterns observed in 14 patients with confirmed multiple portosystemic shunts imaged via transplenic portal scintigraphy. Parameters evaluated included presence of multiple anomalous vessels, presence of hepatofugal flow caudal to spleen, and/or to cranial margin of the kidneys, slow absorption resulting in longer spleen to heart transit time, and presence of biphasic or fragmented bolus. Twenty‐eight additional patients, 14 with a confirmed single portocaval and 14 with a portoazygos shunt, were used for comparison. Nine of 14 (64.3%) patients with multiple shunts had multiple vessels, five (35.7%) had a biphasic bolus, 13 (92.9%) had hepatofugal flow caudal to the cranial margin of the kidneys. In all single portocaval shunts, a single anomalous vessel was identified. None had hepatofugal flow caudal to the border of the kidneys. Among portoazygos shunts, 4/14 (28.6%) had flow caudal to the injection site. Six portoazygos and one portocaval shunts had biphasic bolus. Median transit time from spleen to heart was significantly longer (1.9 s) in patients with multiple shunts than in patients with a portocaval shunt (1.0 s), but not in patients with a portoazygos shunt (1.3 s). Although a distinct plexus of anomalous vessels is not detected in all patients with multiple shunts imaged using transplenic portal scintigraphy, findings of hepatofugal flow caudal to the margin of the kidneys, and longer transit time compared with single portocaval shunts were characteristic. Flow caudal to the splenic injection site but cranial to the kidneys and biphasic bolus can also be seen with a single congenital shunt.  相似文献   

4.
Philip D.  Koblik  DVM  MS  Chi-Kwan  Yen  MD  Jan  Komtebedde  DVM  William J.  Hornof  DVM  MS  Peter F.  Moore  BvSc  PhD  Paul E.  Fisher  MS 《Veterinary radiology & ultrasound》1990,31(4):170-174
Shunt fraction was determined using transcolonic 123I-iodoamphetamine (IMP) and portal vein injection of 99mTc-macroaggregated albumin (MAA) in a group of eight dogs with chronic cirrhosis and acquired portosystemic shunts subsequent to total common bile duct ligation. Hepatic parenchymal damage was confirmed by alterations in liver function tests and liver histology. Seven of the eight dogs developed portal hypertension and had angiographic evidence of hepatofugal portal blood flow with multiple peripheral portosystemic anastomoses. Shunt fractions determined in the seven dogs with shunts varied from 39 to 100 using IMP and 45 to 93 using MAA. The remaining dog had normal portal pressure, a normal portal angiogram, and normal IMP and MAA scintigraphic studies. There was an excellent correlation between the two methods of shunt fraction calculation (R2= 0.98) and the line of regression was not significantly different from unity (IMP = 1.09 × MAA - 0.03).  相似文献   

5.
This study reports data obtained from per-rectal 99mTc-pertechnetate portal scintigraphy in normal cats. It examines the effects of chemical restraint and the methods employed in defining regions of interest (ROIs) on the shunt index derived from this data. Six normal cats were used for the study; all six were chemically restrained for imaging using propofol and later four of them were manually restrained for comparison. Portal blood flow was studied and the mean shunt index was found to be 5.9%± 3.9 when ROIs were operator defined and 9.2%± 4.4 when ROIs were defined using an isocontour program. In cats that were restrained using propofol and operator defined ROIs, the mean value for the time between detection of radioactivity in the liver and in the heart was 14 ± 1 seconds.  相似文献   

6.
Philip D.  Koblik  DVM  MA  Chi-K  Yen  MD  William J.  Hornof  DVM  MS  Pamela  Whiting  DVM  Paul  Fisher  BS 《Veterinary radiology & ultrasound》1989,30(2):67-73
Transcolonic 123I-Iodoamphetamine is rapidly absorbed across the colonic mucosa and binds to amine receptors in the liver and lungs. During the first ten minutes following colonic administration, a simple ratio of lung counts to lung counts plus liver counts provides an accurate estimate of the fraction of portal blood that bypasses hepatic sinusoids in dogs with portosystemic shunts. Studies were performed on 24 dogs with suspect portosystemic shunt. Shunt fraction values for 18 dogs with surgically confirmed portosystemic shunt were obviously higher than published values for normal dogs, and also significantly higher than values for the other six dogs, later confirmed to lack shunts. Postoperative studies were repeated on ten dogs with single shunt vessels 1–2 days after shunt closure. Total shunt ligation resulted in normal postoperative shunt fraction, whereas partial shunt ligation resulted in persistant elevation of shunt fraction. Transcolonic iodoamphetamine scintigraphy is noninvasive, easy to perform, and provides an accurate method to diagnose dogs with portosystemic shunt.  相似文献   

7.
Localization of 99mTc-MDP in lymph nodes was apparent on the three-hour bone-scan image in seven dogs. In six dogs injection or leakage of the radiopharmaceutical into the perivascular tissues was associated with subsequent uptake in an ipsilateral lymph node. In the remaining dog, 99mTc-MDP localized in a lymph node infiltrated by metastatic osteosarcoma. This aided staging of the tumor. Possible mechanisms of 99mTc-MDP localization in soft tissues are briefly reviewed.  相似文献   

8.
Quantitative hepatobiliary scintigraphy using 99mTc-2,6 diisopropylphenylcarbamoylmethyl iminodiacetic acid (DISIDA) was performed in normal dogs. 99mTc-DISIDA is excreted by the hepatocyte into the biliary tract. Hepatic blood flow from arterial and portal venous sources was measured as the hepatic perfusion index. The hepatic clearance of the radiopharmaceutical was used to assess hepatocyte function and parenchymal biliary transport. Biliary ejection was evaluated using synthetic cholecystokinin infusion. The procedure should be useful in evaluating dogs with hepatic and biliary disease.  相似文献   

9.
Gregory B.  Daniel  DVM  MS  Ronald  Bright DVM  MS  Eric  Monnet  DVM  Paul  Ollis  RT 《Veterinary radiology & ultrasound》1990,31(4):175-181
Per-rectal portal scintigraphy using tech-netium-99m pertechnetate (99mTcO4-) was performed in 8 normal dogs before and after surgical creation of a portacaval shunt. Shunt fractions were calculated by computer assisted analysis of dynamic images (IMG) and compared to shunt fractions determined by mesenteric venous injection of radioactive microspheres (MIC). The mean pre-operative shunt fraction was 1.59% using IMG and 3.00% using MCI. The mean postoperative shunt fraction was 64.56% using IMG and 69.56% using MIC. There was excellent correlation between both methods (r2 0.94). Per-rectal portal scintigraphy is an easily performed, inexpensive method to diagnose and quantify portosystemic shunts in dogs.  相似文献   

10.
The normal 99mTc-diethylenetriaminepentaacetic acid (DTPA) renal scintigram curve has 3 distinct phases; an arterial phase followed by progressive uptake and subsequent excretion from the kidney. In dogs with X-linked hereditary nephritis, a distinct flattening of the renal scintigram curve has been observed prior to any decline in glomerular filtration rate (GFR). The cause of this shape change is not known, however, it coincided with decreased urine-specific gravity and thus might be related to polyuria. To further evaluate this possibility, we assessed whether diuresis without concurrent renal disease could flatten the 99mTc-DTPA renal scintigram curve. GFR scintigraphy was performed in six healthy dogs once as a baseline, and again after induction of diuresis by each of four different methods. Scintigram curves were evaluated subjectively as well as quantitatively by calculation of GFR estimates, mean renal transit times, time to peak activity and half-time clearance. Complete flattening of the renal scintigram curve did not occur with diuresis alone, and therefore, flattening of the scintigram curve may serve as an early indicator of renal dysfunction. However, during diuresis after intravenous saline administration, alterations in time to peak activity and mean renal transit time may create inaccuracies in GFR estimates based on the conventional regression formula that cause a false lowering of the resultant global GFR value.  相似文献   

11.
Diuretic renal scintigraphy is commonly used in human medicine to differentiate obstructive from nonobstructive pyelectasia. In order to determine normal parameters, 99mTc-DTPA renal scintigraphy was performed twice in 20 healthy adult Mongrel dogs. Each dog was injected with either 3.0 mg/kg furosemide or an equivalent volume of saline 4.5 min following injection of the radiopharmaceutical. The following parameters were evaluated: (1) global and individual glomerular filtration rate (GFR); (2) time of peak (TOP) of the time-activity curve (TAC); (3) shape of the TAC; (4) individual kidney excretion half-time (T1/2); (5) proportion of maximum activity measured at end of study (8 min); (6) time of onset; and (7) duration of the effect of the diuretic. Most TAC in the diuretic renography group showed a steep drop in the curve following administration of the diuretic compared with a gradual slope in the saline control group. There was a statistically significant difference in T1/2 between the control renograms (median 10.25 min, range 4.41-18.07 min) and the diuretic renograms (median 4.16 min, range 3.62-5.90 min). There was a statistically significant difference in percentage maximum activity between the control renograms (median 65.25%, range 48.27-93.68%) and the diuretic renograms (median 48.54%, range 35.64-58.76%). Median time of onset of the diuretic effect was 1.10 min (0.20-2.40 min), and median duration was 0.83 min (0.30-2.35 min).  相似文献   

12.
The purpose of this study was to evaluate the utility of double-phase parathyroid scintigraphy using 99mTc-sestamibi for detecting and localizing hyperfunctioning parathyroid glands in hypercalcemic dogs. Fifteen hypercalcemic dogs that underwent parathyroid scintigraphy were included in this study: 3 dogs with hypercalcemia of malignancy, and 12 dogs with hyperfunctioning parathyroid tissue (parathyroid adenoma or parathyroid hyperplasia). The presence of parathyroid adenoma or parathyroid hyperplasia was documented by histopathologic examination. In 3 dogs with hypercalcemia of malignancy, parathyroid scintigraphy was negative for hyperfunctioning parathyroid tissue and the scans were classified as true negative. Parathyroid scintigraphy correctly identified the presence and location of hyperfunctioning parathyroid tissue in only 1 of 6 dogs with a parathyroid adenoma. False positive and false negative results occurred in dogs with parathyroid adenomas. Parathyroid scintigraphy failed to detect hyperfunctioning parathyroid tissue in 5 of 6 dogs with parathyroid hyperplasia and were classified as false negative. False positive results were obtained in the remaining dog with parathyroid hyperplasia. Sensitivity of parathyroid scintigraphy for detecting and localizing hyperfunctioning parathyroid tissue was 11%, specificity was 50%, and overall accuracy was 27%. Positive and negative predictive value were 25% and 27%, respectively. Sensitivity for detection of parathyroid adenomas was 25%, and sensitivity for detection of hyperplastic glands was 0 %. Results of this study indicate that double-phase parathyroid scintigraphy does not appear to have acceptable accuracy in detecting hyperfunctioning parathyroid glands in dogs. Due to the poor sensitivity and specificity of the technique in dogs, parathyroid scintigraphy is not recommended for definitive identification of abnormal parathyroid glands as the cause of hypercalcemia in dogs.  相似文献   

13.
Quantitative hepatic scintigraphy is a valid means for estimating total liver blood flow and relative portal hepatic perfusion. The Hepatic perfusion index (HPI) was determined for a group of 12 dogs with portosystemic shunts prior to and two days after corrective surgery. HPI values for the dogs prior to operation were significantly elevated (p<0.001) as compared with those for a group of normal dogs, indicating reduced effective portal hepatic perfusion in dogs with shunts. Dogs showing a favorable clinical response after surgery had a significant decrease (p<0.02) in HPI values after operation. One dog showing a poor clinical response after operation had an increase in HPI score after operation. Quantitative hepatic scintigraphy is a valuable diagnostic test for screening presumptive cases of portosystemic shunts and monitoring the response to surgical intervention.  相似文献   

14.
(99M)Tc-ciprofloxacin was used to image five adult camelids and a juvenile goat with clinical and/or radiographic signs of infection. (99m)Tc-ciprofloxacin (range 10-33 MBq/kg) was injected intravenously and a series of 2-min static images were acquired at 1- and 4-h postinjection. At 24-h postinjection, 5-min static images were acquired. Only the skull or abdomen was imaged in the adults; the whole body was imaged in the goat. The quality of the 1-, 4-, and 24-h studies was evaluated subjectively. Normal and abnormal areas of (99m)Tc-ciprofloxacin uptake were recorded and subjectively graded as mild, moderate or intense. Image quality was best 4-h postinjection. Twenty-four-hour images were poor because of insufficient radioactivity. (99m)Tc-ciprofloxacin imaging resulted in true positive or true negative scans in four of six animals. Two false-negative studies occurred. Intense (99m)Tc-cirofloxacin activity was seen in the lungs and urinary bladder, moderate/intense activity in the kidneys, and mild activity in the physes/epiphyses, liver and intermittently in the gastrointestinal tract. The normal distribution of (99m)Tc-ciprofloxacin in camelids/small ruminants differed from people. Further studies to determine the sensitivity and specificity of infection detection using (99m)Tc-ciprofloxacin in animals are warranted.  相似文献   

15.
We describe the use of ultrasonography‐guided percutaneous splenic injection of agitated saline and heparinized blood for the diagnosis of portosystemic shunts (PSS) in 34 dogs. Agitated saline mixed with 1 ml of heparinized autologous blood was injected into the spleen of 34 sedated dogs under sonographic guidance. The transducer was then sequentially repositioned to visualize the portal vein, the caudal vena cava, and the right atrium through different acoustic windows. It was possible to differentiate between intrahepatic and extrahepatic shunts depending on the entry point of the microbubbles into the caudal vena cava. Portoazygos shunts and portocaval shunts could be differentiated based on the presence of microbubbles in the caudal vena cava and/or the right atrium. In one dog, collateral circulation due to portal hypertension was identified. In dogs with a single extrahepatic shunt, the microbubbles helped identify the shunting vessel. The technique was also used postoperatively to assess the efficacy of shunt closure. All abnormal vessels were confirmed by exploratory laparotomy or with ultrasonographic identification of the shunting vessel. Ultrasound‐guided transsplenic injection of agitated saline with heparinized blood should be considered as a valuable technique for the diagnosis of PSS; it is easy to perform, safe, and the results are easily reproducible.  相似文献   

16.
K. Peremans  DVM  P. De  Bondt  MD  K. Audenaert  MD  K. Van  Laere  MD  DRSC  I. Gielen  DVM  M. Koole  MSc  J. Versijpt  MD  H. Van  Bree  DVM  PhD  F. Verschooten  DVM  R. Dierckx  MD  PhD 《Veterinary radiology & ultrasound》2001,42(6):562-568
Single photon emission computed tomography (SPECT) of the brain using perfusion tracers allows estimation of regional brain perfusion. This allows in vivo examination of brain function in the setting of neuropsychologic and pathophysiologic changes. However functional imaging data on brain perfusion in dogs are limited. Hence, the aim of this study was to determine the scintigraphic regional perfusion pattern of the normal canine brain. Ten healthy shepherd type dogs were injected with 925 MBq Technetium-99m ethyl cysteinate (ECD) 20 minutes before the examination. Acquisition was performed using a triple head gamma camera equipped with fanbeam collimators. Uniform attenuation correction and triple energy window correction were applied. Computed tomographic images were obtained from the same dogs, reoriented along the orbito-meatal axis and SPECT perfusion data were coregistered to the CT-volume data. Based on morphological and suggested brain divisions, regions-of-interest (ROIs) were defined for the bilateral frontocerebral, temporocerebral, parietocerebral, occipitocerebral, cerebellar, thalamic, and striatal area. Regional count density was normalized on total counts. All dogs had the highest uptake in the thalamic/striatal area compared to a rather homogeneous cerebral uptake. No significant left/right count differences were found, but a rostro-caudal gradient (+12-13%) was present. In this group, age and gender did not influence the perfusion pattern.  相似文献   

17.
99mTc-methylene diphosphonate (MDP) radionuclide imaging examinations were done in four horses having clinical evidence of skull trauma or infection. Radiographs were made of each horse prior to scintigraphy. Four case histories are presented. In each instance, scintigraphy provided complementary information to that obtainable through radiography, which aided in accurately localizing and characterizing the site and extent of abnormalities, and which proved particularly valuable as an aid for therapeutic planning.  相似文献   

18.
The purpose of this study was to use quantitative computed tomography (CT) to estimate liver volume in dogs with a portosystemic shunt and to compare the liver volume in normal dogs to dogs with a shunt. Twenty-one dogs with a portosystemic shunt underwent contrast-enhanced abdominal CT for shunt characterization and preoperative planning. Six dogs without clinical signs relating to liver disease were used as a control group. In addition, liver volume was compared before and 2-4 months after surgical shunt attenuation in three dogs. All studies followed established clinical imaging protocols. Liver margins were defined on each image using an operator-defined region of interest and hepatic volume renderings were produced from which the liver volume was quantitatively estimated. There was a statistically significant association between liver volume and body weight in control and shunt dogs (r = 0.909 and 0.899, respectively, P < 0.01). Liver volume normalized to body weight was 15.5 +/- 5.2 cm3/kg in affected dogs and 24.5 +/- 5.6 cm3/kg in control dogs. Based on postligation CT studies in three affected dogs, liver volume increased by 43%, 51%, and 62%. Hepatic volume estimation may be a clinically useful parameter in the initial and postsurgical evaluation of dogs with portosystemic shunts.  相似文献   

19.
Ten scintigraphic gastrointestinal bleeding localization examinations were done in nine dogs. All dogs had clinical evidence of gastrointestinal bleeding prior to or on the day of the examination. Scintigraphy was done by in vivo labeling of red blood cells with 99mTechnetium and imaging serially with a gamma camera over a 21-hour period. Of the nine dogs, four case history reports are presented. Three of these dogs had positive scintigraphic examinations. One dog had a negative scan but was later shown to have been ingesting material that mimicked the appearance of melena.  相似文献   

20.
This report describes the evaluation of cutaneous lymphoma in a cat using 99mTc-sestamibi. A mass in the left pes with extension to the left popliteal lymph node was diagnosed as B-cell lymphoma. Thoracic and abdominal radiography and abdominal ultrasound were unremarkable. Scintigraphy using 99mTc-sestamibi confirmed the lesion was confined to the left hind leg, and the leg was amputated. The cat made a full recovery.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号