首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Typha latifolia-planted vertical subsurface flow constructed wetlands (VSSF CWs) can be used to treat petroleum refinery wastewater. This study evaluated if the removal efficiency of VSSF CWs can be improved by changing the plant species or coupling horizontal subsurface flow constructed wetlands (HSSF CWs) to the VSSF CW systems. The VSSF CWs had a removal efficiency of 76% for biological oxygen demand (BOD5), 73% for chemical oxygen demand (COD), 70% for ammonium-N (NH4+-N), 68% for nitrate-N (NO3?-N), 49% for phosphate (PO43?-P), 68% for total suspended solids (TSS), and 89% for turbidity. The HSSF CWs planted with T. latifolia further reduced the contaminant load of the VSSF CW-treated effluent, giving an additional removal efficiency of 74, 65, 43, 65, 58, 50, and 75% for, respectively, BOD5, COD, NH4+-N, NO3?-N, PO43?-P, TSS, and turbidity. The combined hybrid CW showed, therefore, an improved effluent quality with overall removal efficiencies of, respectively, 94% for BOD5, 88% for COD, 84% for NH4+-N, 89% for NO3?-N, 78% for PO43?-P, 85% for TSS, and 97% for turbidity. T. latifolia strived well in the VSSF and HSSF CWs, which may have contributed to the high NH4 +-N, NO3?-N, and PO43?-P removal efficiencies. T. latifolia-planted VSSF CWs showed a higher contaminant removal efficiency compared to the unplanted VSSF CW. T. latifolia is thus a suitable plant species for treatment of secondary refinery wastewater. Also a T. latifolia-planted hybrid CW is a viable alternative for the treatment of secondary refinery wastewater under the prevailing climatic conditions in Nigeria.  相似文献   

2.
Two horizontal constructed wetlands with subsurface flow (CWs) of different age were monitored in a 2-year study. One of the CWs was new, while the second one had been in operation for 5 years in the first year of study. Transformations of C, P, and N were measured in each CW in the substrate of the vegetated bed under both aerobic and anaerobic conditions, and their rates were compared. C was mineralized in both CWs under both aerobic and anaerobic conditions, but mineralization rates differed between the CWs; they were cca ten times higher in the established CW compared to the new CW. Dissolved reactive phosphorus (DRP) was immobilized under aerobic conditions but was mobilized under anaerobic conditions. DRP transformation was cca five times faster in the established CW. Nitrification occurred under aerobic conditions at similar rates in both CWs. NH4 + concentration decreased under both aerobic and anaerobic conditions, but there was large variability. The age of the CW affected C mineralization rates and DRP immobilization rates under aerobic conditions and mobilization rates under anaerobic conditions; they increased as the CWs maturated, while no effect of CW age was observed on nitrogen removal rates.  相似文献   

3.
曝气对垂直流湿地处理水产养殖废水脱氮的影响   总被引:1,自引:3,他引:1  
人工湿地作为一种有效的污水处理技术,现已被逐渐拓展到水产养殖业中。鉴于其与养殖竞争有限土地资源的弊端,如何构建节地高效型湿地成为未来研究的重点。曝气增氧是强化潜流湿地净化效能的重要措施之一,但是关于曝气强度以及净化效率与影响因素的关系仍缺乏深入系统的研究。为此,该文设计构建了7组不同要素组合的垂直流湿地小试系统,同步或分阶段探讨了曝气强化对垂直流湿地脱氮的影响。研究结果表明,无论曝气与否,构建的7组湿地系统于试验运行工况下都存在明显的硝化过程,且空气复氧和植物根系泌氧足以弥补硝化作用耗氧量。曝气增氧进一步强化了湿地内部的矿化和硝化过程;鉴于养殖废水不缺乏碳源(该研究各组湿地进水碳氮比在28.4~30.6之间),湿地内部的反硝化几率增大,导致曝气后总氮的去除效率提高。但是曝气条件下过高的溶解氧又会进一步抑制反硝化过程,从而也会导致系统总氮去除速率的下降。因此,对垂直流湿地而言,曝气强度不是愈高愈好。为了获得更高的脱氮效率,建议可以通过延长水力停留时间或者在垂直流湿地尾部增设水平潜流湿地来补充反硝化过程,进而提高系统对总氮的去除效果。  相似文献   

4.
In constructed wetlands (CWs) with horizontal sub-surface flow, nutrient removal, especially phosphorus, is limited because the root biomass fills the pore spaces of the substrate (usually gravel), directing wastewater flow to deeper wetland media; plants are not regularly harvested; the litter formed by decomposing vegetation remains on the surface of the substrate and thus does not interact with the wastewater; and the substrate media often used provide only limited adsorption. Effective nutrient removal including rootzone oxidation, adsorption and plant uptake therefore requires sufficient interaction of wastewater with the treatment media. We assessed the feasibility of biological nutrient removal from wastewater using substrate-free CWs with horizontal flow, planted with two tropical macrophytes namely, Cyperus papyrus and Miscanthidium violaceum. The objectives were to evaluate the system treatment efficiency under semi-natural conditions, and to assess microbial and plant biomass contributions to nutrient removal in the CWs. Results showed high removal efficiencies for biochemical oxygen demand, ammonium-nitrogen (NH4–N) and phosphorus (P) fractions in papyrus-based CWs (68.6–86.5%) compared to Miscanthidium (46.7–61.1%) and unplanted controls (31.6–54.3%). Ammonium oxidizing bacteria in CW root–mats (108–109 cells/gram dry weight) and residual nitrite and nitrate concentrations in the water phase indicated active system nitrification. Papyrus showed higher biomass production and nutrient uptake, contributing 28.5% and 11.2%, respectively, of the total N and P removed by the system compared to 15% N and 9.3% P removed by Miscanthidium plants. Compared to literature values, nitrification, plant uptake and the overall system treatment efficiency were high, indicating a high potential of this system for biological nutrient removal from wastewaters in the tropics.  相似文献   

5.
Agriculture is a major source of phosphorus (P) and suspended sediment (SS) losses to aquatic ecosystems promoting eutrophication. Mechanical soil loosening equipments such as topsoil looseners or aerators have been reported to improve the physical quality and infiltration of soils susceptible to livestock damage resulting from treading. We hypothesized that soil aeration would significantly decrease the volume of surface runoff and consequent losses of P and SS compared with non‐aerated soil (control) in cattle‐grazed pasture on a poorly structured silt‐loam soil. Hydrologically isolated plots (2 m long × 1 m wide × 0.15 m deep) were installed in aerated and control plots to collect surface runoff following irrigation or rainfall and analysed for P and SS losses for 1 year. Soil physical properties [% macroporosity, bulk density, saturated hydraulic conductivity (Ksat) and unsaturated hydraulic conductivity (Kunsat at ?1kPa)] were measured in the aerated and control treatments and taken before each irrigation event (n = 12). Six months after mechanical aeration was employed, but before cattle grazing commenced, no significant differences in soil physical quality were found between aerated and control treatments, with the exception of a minor increase in Kunsat for the control plots. This lack of treatment difference continued after grazing and was largely attributed to the re‐settling of the poorly structured and dispersive soil. Flow‐weighted mean concentrations and annual loads of dissolved reactive P (DRP) on the mechanically aerated soil (2.24 kg DRP/ha) were approximately double those from the control treatment (1.20 kg DRP/ha). However, no significant differences were observed between treatments for surface runoff volumes and losses of total P and total SS, which may reflect the similar soil physical conditions exhibited between treatments throughout most of the trial. As observed elsewhere, time (days) since grazing or fertilizer application was found to influence P and/or SS losses. We conclude that aeration did not decrease P and SS losses. Any changes in soil physical properties such as macroporosity were short‐lived and therefore unlikely to influence surface runoff and subsequent P and SS losses for this soil type.  相似文献   

6.
In this study, the N2O emission from an intermittently aerated sequencing batch reactor (IASBR-1) treating the separated liquid fraction of anaerobically digested pig manure (SLAP) was investigated. The wastewater had chemical oxygen demand (COD) concentrations of 11,540?±?860?mg?l?1, 5-day biochemical oxygen demand (BOD5) concentrations of 2,900?±?200?mg?l?1and total nitrogen concentrations of 4,041?±?59?mg?l?1, with low COD:N ratios (2.9, on average) and BOD5:N ratios (0.72, on average). Synthetic wastewater, simulating the SLAP with similar COD and nitrogen concentrations but with higher BOD5 concentrations of up to 11,500?±?100?mg?l?1, was treated in another identical reactor (IASBR-2) to compare the effects of carbon source on nutrient removals and N2O emissions. In steady-state, soluble N2O accumulated in the non-aeration periods, with the highest N2O concentrations measured at the end of the non-aeration periods. There was a significant reduction in N2O concentrations during the aeration periods with reductions occurring immediately on commencement of aeration. The mean N2O emissions in an operational cycle were 253.6 and 205.3?mg for IASBR-1 and IASBR-2, respectively. During the non-aeration periods, only 8.3% and 8.4% of total N2O emissions occurred in IASBR-1 and IASBR-2, respectively; while during the aeration periods, 91.7% and 91.6% of N2O emissions took place in IASBR-1 and IASBR-2, respectively. The mean specific N2O generation rates were 0.010 and 0.005?mg (g VSS·min)?1 in the aeration periods, 0.024 and 0.021?mg (g VSS·min)?1 in the non-aeration periods for IASBR-1 and IABSR-2, respectively. Mean nitrogen removal via N2O emissions was 15.6% and 10.1% for IASBR-1 and IASBR-2, respectively. The IASBR-1 with low influent BOD5 concentrations emitted and generated more N2O.  相似文献   

7.
To improve domestic wastewater treatment for total nitrogen (TN) removal, a full-scale constructed wetlands combining an artificially aerated vertical- (AVCW) and a horizontal-flow constructed wetland (HCW) was completed in July 2007. The system covered a total area of 7,610?m2. From 2 July 2007 to 7 August 2008, the treatment capacity was 2,076?m3?day?1 with an aeration quantity of 7,400?m3?day?1. The system effectively reduced the average annual output of BOD5 (52.0?%), NH4?CN (58.41?%), and TP (41.61?%), although the percentage reductions of other pollutants, including chemical oxygen demand (34.1?%), suspended solid (38.9?%), and TN (31.05?%) were lower. The purpose of the HCW was for denitrification of the effluent from the AVCW, and annual average of 34.27?% of NO3?CN was removed compared with the reading at the AVCW outlet. With hydraulic loading increased to 4,152?m3?day?1 from 9 September to 23 November 2007, the removal rate for NO3?CN from the HCW decreased substantially from 48.80 to 18.86?%. The total removal rates of NH4?CN showed significant positive correlation with DO content in the AVCW and with total TN removal rates for the combined system (P?<?0.05). The study indicated that, even with limited artificial aeration, nitrification was very effective for NH4?CN removal.  相似文献   

8.
In this study, the role of Cyperus sp. was evaluated for removal of pollutants from swine wastewater. Vertical-flow pilot scale constructed wetlands (CWs) operating with a hydraulic retention time (HRT) of 72 h were monitored in a greenhouse, located in Viçosa, Brazil. Significant differences were observed for the following parameters: Kjeldahl nitrogen, total phosphorus, alkalinity and electric conductivity, with averages removals of 37.5 and 28.5%, 55.9 and 44.4%, 30.2 and 25.6 and 26.1% and 22.9% (for planted and unplanted CWs, respectively). The rate of dry matter yield from Cyperus sp. was 7.5 g?m?2 day?1, and the nutrient uptake capacities were 21.8, 2.1, 14.0 and 0.9 g?m?2 of N, P, K and Na, respectively. Evapotranspiration (2.7 mm day?1) was statistically higher in the planted CWs. Plants in the CWs are important for achieving high nutrient removal.  相似文献   

9.
Zou  Juan  Guo  Xuesong  Han  Yunping  Liu  Junxin  Liang  Hanwen 《Water, air, and soil pollution》2012,223(2):889-900
Constructed wetlands are recognized as a reliable technology for rural wastewater treatment. However, conventional constructed wetlands face problems with low pollutant removal efficiency and limited oxygen transfer capability. Therefore, a novel vertical flow constructed wetland (VFCW) system with drop aeration was developed in this study. Two pilot-scale vertical flow constructed wetlands of 0.75 m2 each were constructed with the same dimensions and configuration but different media, one of which (named as CW1) was filled with a 1:1 mixture (by weight) of zeolite and dolomite and the other (named as CW2) with the same zeolite only. The oxygen transfer capability of a multilevel two-layer drop aeration device, organics and nitrogen removal of CW1 and CW2, and pollutant distribution along the depths of CW1 and CW2 in different operational phases were studied. The results demonstrated that compared with the direct drop aeration process, the multilevel, two-layer drop aeration device supplied 2–6 mg/L higher dissolved oxygen per meter of drop height, and after installation of the six-level, two-layer drop aeration devices, the 5-day biochemical oxygen demand removal load was improved from 8.1 to 14.2 g m−2 day−1 for CW1. With regard to the different filter media, nitrogen removal was improved by the adsorption of zeolite in the first year, with 5–36% higher NH4+–N removal efficiency of CW2 compared with that in CW1. Since it did not have a significant positive effect on phosphate removal, dolomite can be replaced by zeolite. The chemical oxygen demand removal mainly took place in the upper 15-cm filter layer in different operational phases, while nitrogen distribution along the depths of the VFCWs was different in different operational phases. In addition, as no operational problems occurred, the vertical flow constructed wetland system with drop aeration is an appropriate alternative for rural wastewater treatment, with numerous advantages of low capital and operation costs, no energy consumption, easy maintenance, high hydraulic loading rate, high pollutant removal efficiency, and no clogging.  相似文献   

10.
In order to investigate the effects of microorganisms and their urease activities in macrophytic root zones on pollutant removal, four small-scale plots (SSPs) of vertical/reverse-vertical flow wetlands were set up to determine: a) the relationship between the abundance of microorganisms in the root zones and water purification efficiency; and b) the relationship between urease activities in the root zones and pollutant removal in a constructed wetland system. Total numbers of the microbial population (bacteria, fungi, and actinomyces) along with urease activities in the macrophytic root zones were determined. In addition, the relationships between microbial populations and urease activities as well as the wastewater purification efficiencies of total phosphorus (TP), total Kjeldahl nitrogen (TKN), biochemical oxygen demand in 5 days (BOD5), and chemical oxygen demand (COD) were also analyzed. The results showed that there was a highly significant positive correlation (r = 0.9772, P < 0.01) between the number of bacteria in the root zones and BOD5 removal efficiency and a significant negative correlation (r = -0.9092, P < 0.05) between the number of fungi and the removal efficiency of TKN. Meanwhile, there was a significant positive correlation (r = 0.8830, P < 0.05) between urease activities in the root zones and the removal efficiency of TKN. Thus, during wastewater treatment in a constructed wetland system, microorganism and urease activities in the root zones were very important factors.  相似文献   

11.
Hydroponics culture generates large amounts of wastewater that are highly concentrated in nitrate and phosphorus but contains almost no organic carbon. Constructed wetlands (CWs) have been proposed to treat this type of effluent, but little is known about the performance of these systems in treating hydroponic wastewater. In addition, obtaining satisfactory winter performances from CWs operated in cold climates remains a challenge, as biological pathways are often slowed down or inhibited. The main objective of this study was to assess the effect of plant species (Typha sp., Phragmites australis, and Phalaris arundinacea) and the addition of organic carbon on nutrient removal in winter. The experimental setup consisted of 16 subsurface flow CW mesocosms (1 m2, HRT of 3 days) fed with 30 L?d1 of synthetic hydroponics wastewater, with half of the mesocosms fed with an additional source of organic carbon (sucrose). Carbon addition had a significant impact on nitrate and phosphate removal, with removal means of 4.9 g m-2?d-1 of NO3-N and 0.5 g m-2 d-1 of PO4-P. Planted mesocosms were generally more efficient than unplanted controls. Furthermore, we found significant differences among plant treatments for NO3-N (highest removal with P. arundinacea) and COD (highest removal with P. australis/Typha sp.). Overall, planted wetlands with added organic carbon represent the best combination to treat hydroponics wastewater during the winter.  相似文献   

12.
Growth of a nonpathogenic E. coli strain (K12- MG1655, ATCC 700926) in aerated and nonaerated compost teas containing molasses, kelp and carrot juice was examined. Teas were prepared using four different compost types that had undetectable levels of indigenous E. coli. Three of the composts were produced by turn pile windrow composting method using dairy, swine and horse manure as feedstock, while the fourth, a vermicompost, was produced by feeding separated dairy solids to worms Eisenia feotida. Molasses and kelp enhanced the growth of E. coli in inoculated teas and the E. coli density was positively correlated with nutrient concentrations ranging from 0.1 to 8.0 g/L. Irrespective of the presence of molasses and kelp, E. coli was not detected in noninoculated teas. Even though E. coli is a facultative anaerobe, its growth was significantly higher in nonaerated teas than in aerated teas. Without aeration, dissolved oxygen in teas declined rapidly and fell below 0.1 mg/L within 20 h, whereas continuous aeration at 0.8 L/min maintained an aerobic condition (> 5 mg/L dissolved oxygen) in teas during the 48 h brewing period. The pH values of nonaerated teas were significantly lower than those of aerated teas and were always slightly acidic. E. coli growth in different compost types was significantly different. The density of E. coli was lowest in teas made with vermicompost and highest in teas made with swine manure compost. E. coli proliferations in both aerated and nonaerated swine manure compost teas were inhibited by carrot juice. Carrot juice lowered dissolved oxygen in aerated teas. The total bacterial densities in noninoculated compost teas were not reduced by carrot juice.  相似文献   

13.
An assessment of influent and effluent data from 24 wastewater treatment plants (WWTPs) in the state of Georgia with design capacities of 37,850 m3/d (10-mgd) or greater was undertaken. Twelve months of operating data from the 2003 calendar year were evaluated. The objectives of the study were to determine the effect of rainfall intensity on the volumetric flow rate to each WWTP and to determine the relationship between flow rate and the influent five-day, biochemical oxygen demand (BOD5) and total suspended solids (TSS) concentrations. The relationships between rainfall intensity and influent BOD concentration, rainfall intensity and influent TSS concentration, influent BOD loading and effluent BOD concentration, and influent TSS loading and effluent TSS concentration were also evaluated. Moderate to strong correlations were observed between rainfall intensity and volumetric flow rate, volumetric flow rate and influent BOD and TSS concentrations, average monthly rainfall intensity and influent BOD and TSS concentrations, and between influent BOD and TSS loadings and effluent BOD and TSS concentrations. Weak correlations were observed for some of the relationships when applied to the complete data set however, stronger correlations were achieved by performing statistical analyses of variance and pooling subsets of the data. Peaking factors for flows and loadings were similar to those reported in the literature.  相似文献   

14.
Abstract

Multi-soil-layering (MSL) system was designed for purifying domestic wastewater and for treating polluted river water. MSL system is typically comprised of layers of soil mixture blocks alternating with permeable layers. The permeable layer has roles of preventing clogging and to increasing the efficiency of infiltration of wastewater through the soil mixture blocks. In this study, the comparative efficiency of five MSL systems as a function of five permeable layer materials (zeolite, zeolitized perlite, perlite, gravel, and charcoal) was investigated. The MSL systems were constructed in 15 × 50 × 100 cm boxes where the soil mixture blocks contained sandy clay soil, kenaf + corncob, and iron scraps at a ratio of 6 : 1 : 1 by weight, respectively, and filled up in alternation with the permeable layer. The results indicated that all the MSL systems at loading rates of 96–346 L m?2 d?1 under nonaerated conditions were able to reduce the levels of COD (342–1,231 mg L?1), BOD5 (201–802 mg L?1), and soluble reactive phosphorus (SRP) (3.5–10.1 mg P L?1) at percentages of 79.0–98.1, 80.0–99.6, and 97.1–100%, respectively. The zeolite and the charcoal-based MSL systems under a 96–346 L m?2 d?1 loading rate effectively reduced the level of TN (41.4–65.5 mg N L?1) at percentages of 79.0–92.1 and 30.7–88.9%, respectively. In terms of prevention of clogging, the charcoal-based MSL system was the most effective, followed by the gravel and zeolite-based MSL. The apparent efficiency of pollutant removal, for zeolitized perlite, perlite, and gravel-based MSL systems was low. With an on-off aeration operation, the efficiency of the MSL systems in the reduction of the levels of COD, BOD5 , and SRP (hereafter reference to as “removal”) was significantly enhanced. Overall, the zeolite-based MSL system seemed to be more effective than the other MSL systems. However, if optimum aeration could be obtained, the removal efficiency of charcoal-based MSL system might be improved. Aeration at a rate of 64,000 L m?3 d?1 for 1 week alternating with 2 weeks of nonaeration enhanced the removal of COD, BOD5 , and SRP but not that of TN.  相似文献   

15.
A study was conducted to evaluate the effectiveness of supplemental aeration in improving the performance of an rotating biological contactor (RBC) treatment system whose first and second stages were overloaded resulting in very low dissolved oxygen conditions and heavy beggiatoa growth thereby deteriorating process performance. A four-stage RBC having two parallel trains and treating combined municipal and industrial dairy wastewater was used to conduct the research. One train was provided with supplemental air in all stages and the other train, without supplemental air, was used as a control. Daily 24-hour compositie samples were collected at the influent to the RBC and at the end of each stage. Dissolved oxygen, pH, and temperature levels were measured in each stage. Samples were analyzed for soluble COD, ammonia nitrogen, total and volatile suspended solids. Samples were also analyzed for soluble BOD5 and oxygen uptake rate once a week. The biomass thickness on the discs was measured and growth conditions were noted. The experimental results indicate that RBC units with supplemental aeration demonstrated remarkable performance and ability to adapt to differing organic loading rates. In addition, beggiatoa growth was completely eliminated with supplemental air thereby establishing thinner and active aerobic biomass.  相似文献   

16.
Based on a combination of Reynolds-Averaged Navier-Stokes equations, standard k-ε equations, and VOF technique, a 2-D dissolved oxygen transport mathematical model was conducted to investigate oxygen-supply characteristics for regular waves with a given still water depth d and various hydrodynamic parameters (incident wave height H and wave period T equivalent to incident wave length L) and intermittent aeration parameters (air flow rate per unit width q, aeration period Ta, aeration depth da and air source area Aa). A series of experiments were conducted to validate the mathematical model, and they agreed well with each other. In addition, a series of dimensionless parameters were conducted to assess their relationships with oxygen transfer coefficient respectively. It was found that oxygen transfer coefficient increased slightly with the increase of \( q/{g}^2{T}_a^3 \). With the increasing \( {d}_a^2/{A}_a \), oxygen transfer coefficient increased obviously for the small \( {d}_a^2/{A}_a \) scenarios; however, it increased slightly for the high \( {d}_a^2/{A}_a \) scenarios. With increasing HL/d2, a linear increase tendency of oxygen transfer coefficient appeared approximately. Furthermore, a simple prediction formula for oxygen transport coefficient was conducted using the numerical data, the dimensional analysis, and the least squares method, and it was validated well with the related experimental data.  相似文献   

17.
The permeable reactive barrier (PRB) filled with natural zeolite plays the role of a reactive treatment zone for remediation of contaminated groundwater. Based on column lab experiments, the volume of remediated solution, the distribution (Kd) and retardation (Rd) coefficients were evaluated, confirming successful removal and retention of zinc from contaminated groundwater. The effect of hydrodynamic dispersion on zinc capturing by zeolite in PRB was evaluated by the hydrodynamic dispersion coefficient (DL) and retarded hydrodynamic dispersion coefficient (DLR) using the Brigham method. For different assumed distances of the barrier, the simulation of one-dimensional zinc concentration profile from the point source through the barrier has been modeled by a simple analytical pulse model. The results show that the flow rate has the most significant effect on the concentration profile, peaks, and broadening of curves. The residence contact time (τ) corresponding to higher Kd and Rd as well as lower DL and DLR values outcomes the optimal range of 6.2–9.4 min. This interval corresponds to the experimental performance at the bed length of 8 and 12 cm and flow rate in the range of 6.38–9.57 PV/h. The calculated minimum thickness and longevity confirm the successful application of zeolite as a material in PRB for remediation of zinc contaminated groundwater.  相似文献   

18.
Nitrous oxide emissions, nitrate, water-soluble carbon and biological O2 demand (BOD5) were quantified in different cropping systems fertilized with varying amounts of nitrogen (clayey loam, October 1991 to May 1992), in an aerated tank (March 1993 to March 1994), and in the nitrification-denitrification unit (March to July 1994) of a municipal waste water treatment plant. In addition, the N2O present in the soil body at different depths was determined (February to July 1994). N2O was emitted by all cropping systems (mean releases 0.13–0.35 mg N2O m-2 h-1), and all the units of the domestic waste water treatment plant (aerated tank 0–6.2 mg N2O m-2 h-1, nitrification tank 0–204,3 mg N2O m-2, h-1, denitrifying unit 0–2.2 mg N2O m-2 h-1). During the N2O-sampling periods estimated amounts of 0.9, 1.5, 2.4 and 1.4 kg N2O–N ha-1, respectively, were released by the cropping systems. The aerated, nitrifying and denitrifying tanks of the municipal waste water treatment plant released mean amounts of 9.1, 71.6 and 1.8 g N2O–N m-2, respectively, during the sampling periods.The N2O emission were significantly positively correlated with nitrate concentrations in the field plots which received no N fertilizer and with the nitrogen content of the aerated sludge tank that received almost exclusively N in the form of NH 4 + . Available carbon, in contrast, was significantly negatively correlated with the N2O emitted in the soil fertilized with 80 kg N ha-1 year. The significant negative correlation between the emitted N2O and the carbon to nitrate ratio indicates that the lower the carbon to nitrate ratio the higher the amount of N2O released. Increasing N2O emissions seem to occur at electron donorto-acceptor ratios (CH2O or BOD5-to-nitrate ratios) below 50 in the cropping systems and below 1200–1400 in the waste water treatment plant. The trapped N2O in the soil body down to a depth of 90 cm demonstrates that agricultural production systems seem to contain a considerable pool of N2O which may be reduced to N2 on its way to the atmosphere, which may be transported to other environments or which may be released at sometime in the future.Dedicated to Professor J.C.G. Ottow on the occasion of his 60th birthday  相似文献   

19.
Constructed wetlands have recently received considerable attention as low cost and efficient means of cleaning up many different types of wastewaters at secondary and tertiary levels. This is an environmentally sound method of wastewater treatment that does not use hazardous chemicals, and is based on the high productivity and nutrient removal capability of the wetland that strongly relies on its intricate ecosystem structure and function. Research work was conducted on a tropical constructed wetland to establish its capability to treat wastewater during the dry season. A comparison of its efficacy with that of conventional wastewater treatment plants was made on the basis of the measured water quality parameters. Temperature, pH, dissolved oxygen, and conductivity were measured in situ. Total suspended solids (TSS), total dissolved solids (TDS), biochemical oxygen demand (BOD5), chemical oxygen demand (COD), phosphorus, ammonia, and nitrites were analyzed in the laboratory. Fecal coliforms were enumerated and Escherichia coli counts were determined. The TSS values reduced from a mean of 102 mg/l at the influent point to 16 mg/l at the effluent point, depicting a reduction of 84.3%. Influent TDS averaged 847 mg/l, while the effluent averaged 783 mg/l. Dry season BOD5 levels were reduced from an average of 286 at the inlet point to 11 mg/l at the outlet representing a reduction efficiency of 96.2%. COD levels were reduced from a mean of 2,002.5 to 47.5 mg/l depicting a removal efficiency of 97.6%. Phosphorus was reduced from a mean of 14 to 11 mg/l representing a percentage removal of 21.4%. Levels of ammonia reduced from a mean of 61 at the influent point to 36 mg/l at the effluent point representing a percent reduction of 41.0%. There was a 99.99% reduction for both the fecal coliforms and E. coli counts. Conductivity of wastewater increased from 1.08 to 1.98 mS, while the pH increased from 6.23 at the inlet point to 7.99 at the outlet of the system. Temperature and dissolved oxygen measurements showed a diurnal variation. The dry season wastewater heavy metal concentrations were in the following ranges: Pb (0.7?C6.9 ppm), Cr (0.2?C0.5 ppm), Zn (0.1?C2.3 ppm), Ni (0.1?C1.3 ppm) with Cd and Cu not being detected in the wastewater streams. Overall, tropical constructed wetlands are effective in treating wastewater streams and they perform a lot better than the popularly used waste stabilization ponds. This paper recommends that they can be widely used within the tropics.  相似文献   

20.
Seven experimental pilot-scale subsurface vertical-flow constructed wetlands were designed to assess the effect of plants [Typha latifolia L. (cattail)], intermittent artificial aeration and the use of polyhedron hollow polypropylene balls (PHPB) as part of the wetland substrate on nutrient removal from eutrophic Jinhe River water in Tianjin, China. During the entire running period, observations indicated that plants played a negligible role in chemical oxygen demand (COD) removal but significantly enhanced ammonia–nitrogen (NH4–N), nitrate–nitrogen (NO3–N) total nitrogen (TN), soluble reactive phosphorus (SRP) and total phosphorus (TP) removal. The introduction of intermittent artificial aeration and the presence of PHPB could both improve COD, NH4–N, TN, SRP and TP removal. Furthermore, aerated wetlands containing PHPB performed best; the following improvements were noted: 10.38 g COD/m2 day, 1.34 g NH4–N/m2 day, 1.04 g TN/m2 day, 0.07 g SRP/m2 day and 0.07 g TP/m2 day removal, if compared to non-aerated wetlands without PHPB being presented.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号