首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A confirmatory method using liquid chromatography-electrospray ionization tandem mass spectrometry for determination of five macrolide antibiotics including spiramycin, tilmicosin, oleandomycin, erythromycin, and tylosin in raw milk is presented. Macrolides were extracted from raw milk by acetonitrile, and sample extracts were further cleaned up using solid-phase extraction cartridges. Data acquisition was achieved using multiple reaction monitoring, that is, two transitions, to provide a high degree of sensitivity and specificity. Matrix-matched standard calibration curves with the use of roxithromycin as an internal standard were utilized to achieve the best accuracy of the method. Both a conventional validation procedure and a designed experiment were applied to study the accuracy and precision of the method. The measurement uncertainty arising from accuracy and precision was estimated. The method accuracy, expressed as a percentage of overall recovery, was approximately 100%, and its intermediate precision was <10%. LC-ESI/MS/MS method detection limits (S/N > or = 3:1) of five macrolides were <0.3 microg/kg.  相似文献   

2.
A new sensitive method for the simultaneous determination of 12 trichothecenes (deoxynivalenol, nivalenol, 3-acetyldeoxynivalenol, 15-acetyldeoxynivalenol, fusarenon X, T-2 toxin, HT-2 toxin, neosolaniol, monoacetoxyscirpenol, diacetoxyscirpenol, T-2 triol, and T-2 tetraol) by liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) is presented. The development of the method and investigations on the matrix influence on the MS signal are described in particular. The matrix effect was thereby minimized by using an internal standard, a special mobile phase, and specific fragmentation parameters. The sample was extracted with acetonitrile/water (84:16, v/v), and the extract was cleaned up with a MycoSep 227 column. Quantification was based on the internal standard de-epoxy-deoxynivalenol. Calibration curves were linear between 16 and 1600 ng/g, and the limits of detection ranged from 0.18 to 5.0 ng/g. The developed method was applied for the determination of trichothecenes in 120 naturally contaminated wheat and oat samples.  相似文献   

3.
A reliable, rapid, and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous determination of chloramphenicol and aflatoxin M(1) in milk has been developed. This method includes simple extraction of sample with acetonitrile, separation on a MGIII-C(18) column using 5 mM ammonium acetate aqueous solution/methanol (60:40, v/v) as mobile phase, and MS/MS detection using multiple reaction monitoring mode. The method was validated according to Commission Decision 2002/657/EC. The limits of detection (LODs) were 0.05 μg/kg for chloramphenicol and 0.005 μg/kg for aflatoxin M(1.) The limits of quantification (LOQs) were 0.2 μg/kg for chloramphenicol and 0.02 μg/kg for aflatoxin M(1). The recovery values ranged from 88.8% to 100.6%, with relative standard deviation lower than 15% in all cases, when samples were fortified at three different concentrations. The decision limits (CCα) and detection capability (CCβ) of the method were also reported. This method has been successfully applied for simultaneous analysis of chloramphenicol and aflatoxin M(1) residues in milk from local supermarkets in China.  相似文献   

4.
Carbohydrates in commercial tobacco products were quantified utilizing a liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) technique. The method utilizes negative ion electrospray with multiple reactions monitoring and an internal standard calibration. Snuffs, chewing tobaccos, cigars, and cigarettes were analyzed. Product type differentiation was possible using the carbohydrate levels coupled with pH and moisture contents. The LC-MS/MS method was compared to a method utilizing ion chromatography with pulsed amperometric detection. The LC-MS/MS method provided improved selectivity and specificity, demonstrated better precision, and had a larger dynamic range for glucose, fructose, and sucrose in tobacco extracts.  相似文献   

5.
A multiresidue method analyzing 209 pesticides in 24 agricultural commodities has been developed and validated using the original Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) procedure and high performance liquid chromatography-positive electrospray ionization-tandem mass spectrometry (LC-MS/MS) analysis. Using solvent-only calibration standards (SOCSs) and matrix-matched calibration standards (MMCSs), it was demonstrated that a minimal concentration of 5-10 μg/kg (part per billion, ppb) of analytes in matrix is required for the consistent identification of targeted pesticides with two MRM transitions. Method performance was validated by the precision and accuracy results obtained from fortification studies at 10, 25, 100, and 500 ppb and MMCSs. The method was demonstrated to achieve an average recovery of 100 ± 20% (n = 4) for >75% of evaluated pesticides at the low fortification level (10 ppb) and improved to >84% at the higher fortification concentrations in all 24 matrices. Matrix effects in LC-MS/MS analysis were studied by evaluating the slope ratios of calibration curves (1.0-100 ng/mL) obtained from the SOCSs and MMCSs. Principal component analysis (PCA) of LC-MS/MS and method validation data confirmed that each matrix exerts its specific effect during the sample preparation and LC-MS/MS analysis. The matrix effect is primarily dependent on the matrix type, pesticide type and concentration. Some caution is warranted when using matrix matched calibration curves for the quantitation of pesticides to alleviate concerns on matrix effects. The QuEChERS method with LC-MS/MS was used to identify and quantitate pesticides residues, with concentrations ranging from 2.5 to >1000 ppb in a variety of agricultural samples, demonstrating fitness for screening and surveillance applications.  相似文献   

6.
A method based on a gel permeation chromatography (GPC) extraction procedure combined with an additional cleanup by solid-phase extraction (SPE) on silica gel and liquid chromatography-mass spectrometry (LC-MS) detection has been validated for the analysis of seven glycidyl esters (GEs) including glycidyl laurate, myristate, palmitate, stearate, oleate, linoleate, and linolenate in various edible oils. This method was conjointly developed and validated by two different laboratories, using two different detection systems, a LC time of flight MS (LC-ToF-MS) and a LC triple-quadrupole MS (LC-MS/MS). The extraction procedure allowed targeting low contamination levels due to a highly efficient matrix removal from the 400 mg oil sample loaded on the GPC column and is suitable for routine analysis as 24 samples can be extracted in an automated and reproducible way every 12 h. GPC extraction combined with SPE cleanup and LC-MS/MS detection leads to a limit of quantification in oil samples between 50 and 100 μg/kg depending on the type of glycidyl ester. Recoveries ranged from 68 to 111% (average = 93%). Quantification was performed by automated standard addition on extracts to compensate matrix effects artifacts. To control recoveries of each sample four isotopically labeled GEs ((13)C(3) or (13)C(4)) were included in the method.  相似文献   

7.
A method was developed and validated to determine 5-hydroxyflunixin in raw bovine milk using liquid chromatography tandem mass spectrometry (LC/MS/MS). The mean recovery and percentage coefficient of variation (%CV) of 35 determinations for 5-hydroxyflunixin was 101% (5% CV). The theoretical limit of detection was 0.2 ppb with a validated lower limit of quantitation of 1 ppb and an upper limit of 150 ppb. Accuracy, precision, linearity, specificity, ruggedness, and storage stability were demonstrated. A LC/MS/MS confirmatory method using the extraction steps of the determinative method was developed and validated for 5-hydroxyflunixin in milk from cattle. Briefly, the determinative and confirmatory methods were based on an initial solvent (acetone/ethyl acetate) precipitation/extraction of acidified whole milk. The solvent precipitation/extraction effectively removed incurred ((14)C) residues from milk samples. The organic extract was then purified by solid phase extraction (SPE) using a strong cation exchange cartridge (sulfonic acid). The final SPE-purified sample was analyzed using LC/MS/MS. The methods are rapid, sensitive, and selective and provide for the determination and confirmation of 5-hydroxyflunixin at the 1 and 2 ppb levels, respectively.  相似文献   

8.
A rapid LC-MS/MS method, using a triple-quadrupole/linear ion trap mass spectrometer, was developed for the quantitative determination of oleandrin in serum, urine, and tissue samples. Oleandrin, the major cardiac glycoside of oleander (Nerium oleander L.), was extracted from serum and urine samples with methylene chloride and from tissues with acetonitrile. The tissue extracts were cleaned up using Florisil solid-phase extraction columns. Six replicate fortifications of serum and urine at 0.001 microg/g (1 ppb) oleandrin gave average recoveries of 97% with 5% CV (relative standard deviation) and 107% with 7% CV, respectively. Six replicate fortifications of liver at 0.005 microg/g (5 ppb) oleandrin gave average recoveries of 98% with 6% CV. This is the first report of a positive mass spectrometric identification and quantitation of oleandrin in tissue samples from oleander intoxication cases. The sensitivity and specificity of the LC-MS/MS analysis enables it to be the method of choice for toxicological investigations of oleander poisoning.  相似文献   

9.
The carcinogenic compound ptaquiloside is produced by bracken fern (Pteridium aquilinum L.). Ptaquiloside can enter the soil matrix and potentially leach to the aquatic environment, and methods for characterizing ptaquiloside content and fate in soil and groundwater are needed. A sensitive detection method has been developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) for analyzing ptaquiloside and its transformation product pterosin B. Detection limits are 0.19 microg/L (ptaquiloside) and 0.15 microg/L (pterosin B), which are 300-650 times better than previously published LC-UV methods. Sequential soil extractions are made using 5 mM ammonium acetate for extraction of ptaquiloside, followed by 80% methanol extraction for pterosin B. Groundwater samples are cleaned-up and preconcentrated by a factor of 20 using solid-phase extraction. The LC-MS/MS method enables quantification of ptaquiloside and pterosin B in soil and groundwater samples at environmentally relevant concentrations and delivers a reliable identification because of the structure-specific detection method.  相似文献   

10.
A precise and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of dapsone in muscle tissue and milk has been developed. The sample preparation was based on extraction with organic solvent and automated solid-phase extraction (SPE) cleanup. At least three product ions were monitored for the analyte. The method was validated according to the European Decision 2002/657/EC. Estimated analytical limits were 0.0018 ng/g for CCα and 0.0031 ng/g for CCβ in meat and milk. An excellent linear concentration range was observed for both matrices with a correlation coefficient better than 0.997. Recoveries were 105-117% in meat and 101-108% in milk, with satisfactory precision and coefficients of variance (CV) less than 8%. Additionally, a simplified quantification approach was successfully evaluated depending only on the response factor (F) without the use of calibration curve. The developed method provides reliable and sensitive identification and quantification of dapsone in meat and milk.  相似文献   

11.
Enzymatic digestion of total protein along with liquid chromatography/tandem mass spectrometry (LC/MS/MS) was used to confirm the presence of a major peanut allergen in food. Several peptides obtained from the enzymatic digestion of the most abundant peanut allergen, Ara h 1, were identified as specific peptide biomarkers for peanut protein. Using ice cream as a model food matrix, a method was developed for the detection of the allergen peptide biomarkers. A key component of the method was the use of molecular mass cutoff filters to enrich the Ara h 1 in the protein extracts. By applying the method to ice cream samples containing various levels of peanut protein, levels as low as 10 mg/kg of Ara h 1 could routinely be detected. This method provides an unambiguous means of confirming the presence of the peanut allergen, Ara h 1, in foods and can easily be modified to detect other food allergens.  相似文献   

12.
A highly selective and sensitive method was developed for the simultaneous determination of 12 sulfonamides in beef and milk by immunoaffinity chromatography purification coupled to ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The MS/MS conditions, UPLC mobile phase, injection solution, sample purification process, and matrix effect were studied to optimize the operating conditions. The limits of detection (LODs) of the instrument for the studied sulfonamides ranged from 0.4 to 2.0 μg L(-1), being 1.6-8.0 μg kg(-1) for beef and 1.8-6.4 μg kg(-1) for milk. The standard solution was diluted with blank beef or milk matrix for the construction of calibration curves, which had a linear range from 10 to 200 μg kg(-1) and regression coefficients higher than 0.990 (n=10) for all the studied sulfonamides. Samples spiked at 10, 20, and 100 μg kg(-1) showed recoveries above 70% and relative standard deviations below 10%.  相似文献   

13.
A sensitive method is described for the determination and confirmation of zeranol and zearalenone, as well as their isomers and metabolites, in edible animal tissue. The analytes are extracted from tissue with methanol, hydrolyzed enzymatically, cleaned up by acid-base partitioning, determined by liquid chromatography (LC) with electrochemical (EC) detection, and confirmed by gas chromatography/mass spectrometry (GC/MS). LC analysis is performed by isocratic elution with a buffered mobile phase using a Nova-Pak reverse-phase C18 column with amperometric EC detection at +0.90 V. Capillary GC/MS analysis of the trimethylsilyl derivatives provides mass spectral confirmations.  相似文献   

14.
A method making use of turbulent flow chromatography automated online extraction with tandem mass spectrometry (MS/MS) was developed for the analysis of 4 quinolones and 12 fluoroquinolones in honey. The manual sample preparation was limited to a simple dilution of the honey test portion in water followed by a filtration. The extract was online purified on a large particle size extraction column where the sample matrix was washed away while the analytes were retained. Subsequently, the analytes were eluted from the extraction column onto an analytical column by means of an organic solvent prior to chromatographic separation and MS detection. Validation was performed at three fortification levels (i.e., 5, 20, and 50 microg/kg) in three different honeys (acacia, multiflower, and forest) using the single-point calibration procedure by means of either a 10 or 25 microg/kg calibrant. Good recovery (85-127%, median 101%) as well as within-day (2-18%, median 6%) and between-day (2-42%, median 9%) precision values was obtained whatever the level of fortification and the analyte surveyed. Due to the complexity of the honey matrix and the large variation of the MS/MS transition reaction signals, which were honey-dependent, the limit of quantification for all compounds was arbitrarily set at the lowest fortification level considered during the validation, e.g., 5 microg/kg. This method has been successfully applied in a minisurvey of 34 honeys, showing ciprofloxacin and norfloxacin as the main (fluoro)quinolone antibiotics administered to treat bacterial diseases of bees. Turbulent flow chromatography coupled to LC-MS/MS showed a strong potential as an alternative method compared to those making use of offline sample preparation, in terms of both increasing the analysis throughput and obtaining higher reproducibility linked to automation to ensure the absence of contaminants in honey samples.  相似文献   

15.
A simple, sensitive, and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for determining urinary creatinine was developed and used to evaluate 24 h urine samples collected during an exposure study. Urine (1 microL) was diluted with methanol and then directly applied to LC-MS/MS. Under electrospray ionization (ESI) conditions, the transition molecules of creatinine and creatinine- d3 were observed at m/ z 114 > 44 and m/ z 117 > 47, respectively. The retention time of creatinine was 0.59 min. The linear range was 1-2000 ng/mL, with a detection limit in urine of 1 ng/mL. LC-MS/MS and colorimetric end-point methods were significantly associated ( R2 = 0.8785, p < 0.0001). The LC-MS/MS method to determine creatinine in 24 h urine samples had shorter retention times, was more sensitive, reliable, reproducible, simple, selective, and used a smaller sample size than other LC-MS/MS or commercial methods.  相似文献   

16.
Detection of peptides from the peanut allergen Ara h 1 by liquid chromatography-mass spectrometry (LC-MS) was used to identify and estimate total peanut protein levels in dark chocolate. A comparison of enzymatic digestion subsequent to and following extraction of Ara h 1 from the food matrix revealed better limits of detection (LOD) for the pre-extraction digestion (20 ppm) than for the postextraction digestion (50 ppm). Evaluation of LC-MS instruments and scan modes showed the LOD could be further reduced to 10 ppm via a triple-quadrupole and multiple-reaction monitoring. Improvements in extraction techniques combined with an increase in the amount of chocolate extracted (1 g) improved the LOD to 2 ppm of peanut protein. This method provides an unambiguous means of confirming the presence of the peanut protein in foods using peptide markers from a major allergen, Ara h 1, and can easily be modified to detect other food allergens.  相似文献   

17.
An LC-MS/MS method was developed for the semiquantitative determination of strophanthidin glycosides in ingesta from animals. Strophanthidin glycosides were simultaneously extracted and hydrolyzed to the strophanthidin aglycone using aqueous methanolic hydrochloric acid and the extracts cleaned up using solid-phase extraction. Extracts were analyzed using reverse-phase HPLC coupled with positive ion electrospray mass spectrometry. Characteristic product ion spectra were produced by fragmentation of the [M + H](+) precursor ion for each analyte. Quantitation was performed using the internal standard method with digitoxigenin serving as the internal standard. The method detection limit was calculated to be 0.075 microg/g, and the limit of quantitation was calculated to be 0.24 microg/g for strophanthidin in control rumen samples. This method was used in diagnostic investigations to confirm fatal strophanthidin glycoside poisonings in horses.  相似文献   

18.
Liquid chromatography-ion trap tandem mass spectrometry (LC-MS/MS) with electrospray ionization was used to identify cephapirin metabolites and degradants in milk from cows dosed with cephapirin. The milk was extracted according to a previously published procedure. Structures for various components were tentatively identified by their molecular weight, product ion mass spectra, and/or correspondence to standard mass spectra. These components may have occurred as metabolites or as degradants that occurred on storage or during extraction. Compounds identified in the milk included cephapirin, desacetylcephapirin, cephapirin lactone, hydrolyzed cephapirin, and a reduced cephapirin lactone that has not previously been reported. Methylcephapirin was also identified, possibly as a trace contaminant in the formulation. Analysis of incurred milk extracts showed that cephapirin and desacetylcephapirin are the major residues in milk. Desacetylcephapirin residues persisted about as long as the parent drug. The detection limit for both residues by LC-MS/MS was approximately 1 ng/mL in milk. These results have implications for microbiological methods or rapid test kits, if such methods or kits respond to cephapirin metabolites and degradants present in the milk.  相似文献   

19.
In this study, a nanocomposite of polypyrrole-coated magnetite nanoparticles (denoted as MNPs/PPy) was prepared and employed as magnetic solid-phase extraction (MSPE) sorbent for extraction of estrogens from milk samples. Because the polypyrrole coating possessed a highly π-conjugated structure and hydrophobicity, MNPs/PPy showed excellent performance for the estrogen extraction. Estrogens could be captured directly by MNPs/PPy from milk samples without protein precipitation. Moreover, the extraction could be carried out within 3 min. Thus, a rapid, simple, and effective method for the analysis of estrogens in milk samples was established by coupling MNPs/PPy-based MSPE with liquid chromatography-tandem mass spectrometry (LC-MS/MS). The limits of detections for estrogens investigated were in the range of 5.1-66.7 ng/L. The recoveries of estrogens (concentration range of 0.5-20 ng/mL) from milk samples were in the range of 83.4-108.5%, with relative standard deviations ranging between 4.2 and 15.4%.  相似文献   

20.
An analytical method was developed for the determination of eleven agrochemicals [abamectin (as B1a), bifenazate, bifenthrin, carfentrazone-ethyl, cymoxanil, hexythiazox, imidacloprid, mefenoxam, pymetrozine, quinoxyfen, and trifloxystrobin] in dried hops. The method utilized polymeric and NH2 solid phase extraction (SPE) column cleanups and liquid chromatography with mass spectrometry (LC-MS/MS). Method validation and concurrent recoveries from untreated dried hops ranged from 71 to 126% for all compounds over three levels of fortification (0.10, 1.0, and 10.0 ppm). Commercially grown hop samples collected from several field sites had detectable residues of bifenazate, bifenthrin, hexythiazox, and quinoxyfen. The control sample used was free of contamination below the 0.050 ppm level for all agrochemicals of interest. The limit of quantitation and limit of detection for all compounds were 0.10 and 0.050 ppm, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号