首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
M-mode echocardiographic measurements were made from 50 healthy German Shepherd dogs (30 males and 20 females). The dogs were awake and unsedated, in right lateral recumbent position. The following parameters were measured on the echocardiographic images: interventricular septal thickness at end-diastole (IVSd), interventricular septal thickness at end-systole (IVSs), left ventricular internal dimension at end-diastole (LVIDd), left ventricular internal dimension at end-systole (LVIDs), left ventricular posterior wall thickness at end-diastole (LVPWd), left ventricular posterior wall thickness at end-systole (LVPWs), left atrial dimension (LAD), aortic root dimension (AOD), left atrial to aortic root ratio (LAD/AOD), right ventricular internal dimension at end-diastole (RVID), amplitude of mitral valve excursion (DE amplitude), velocity of mitral valve opening (D-E slope), and velocity of mitral valve closure (E-F slope). Fractional shortening (FS) was also calculated. The effect of gender and age on each echocardiographic parameter was analyzed and the relationship between body weight (BW) and each parameter was also investigated. There was a significant relationship between gender and LVPW in systole and diastole and FS. Significant association was also found between BW and IVS, LVID, and LVPW in systole and diastole, FS, LAD, AOD, RVID, DE amplitude, and D-E slope of the mitral valve.  相似文献   

2.
The objective of this retrospective study is to determine normal reference values for 2-Dimension (2D) and Motion-mode (M-mode) echocardiographic parameters in nonsedated healthy young adult Sphynx cats and to compare them to those of the domestic shorthair (DSH). 131 Sphynx cats underwent cardiac screening prior to breeding. The control group consisted of 30 healthy adult domestic cats. A complete cardiac ultrasound was performed on all cats using right parasternal long and short axis views. There were few echocardiographic parameters in the Sphynx that differed from those of the healthy DSH. Only the left atrial (LA) dimension in 2D and M-mode, the left atrial/aortic (LA/Ao) ratio and the internal dimension of the left ventricle in systole (LVIDs) measured with M-mode were different. In conclusion, although the heart of Sphynx cat can often have a particular 2-D echocardiographic appearance, the M-mode cardiac dimensions are similar to those of the DSH.  相似文献   

3.
Donkey (Equus asinus), the cheapest form of agricultural power in Egypt, is used principally as draught or pack animals and may also be ridden, or used for threshing, raising water, milling, and other work. The aim of the present study was to provide B-mode and M-mode echocardiographic reference ranges from a sample of population of donkeys (E. asinus) based on the probability theory and statistics. In the present study, B-mode and 2-dimensional guided M-mode echocardiography were performed on 44 clinically healthy donkeys (E. asinus) (22 males and 22 females), without any neither clinical nor echocardiographic evidence of cardiovascular diseases, aged 2–25 year old, and weighed 150–350 kg. The echocardiographic dimensions, including interventricular septum thickness at end diastole, interventricular septum thickness at end systole, left ventricular internal diameter at end diastole, left ventricular internal diameter at end systole, left ventricular posterior wall thickness at end diastole, and left ventricular posterior wall thickness at end systole were assessed. The cardiac function indices, including end diastolic volume, end systolic volume, stroke volume, ejection fraction, and fractional shortening were also measured. B-mode and guided M-mode echocardiographic examination of healthy donkeys revealed that both the interventricular septum thickness and the left ventricular posterior free wall were greater during systole than diastole. However, the left ventricular dimension during diastole was greater than systole. Furthermore, the recorded data of cardiac function indices, including end diastolic volume, end systolic volume, stroke volume, ejection fraction, and fractional shortening using B-mode echocardiography were closer to those recorded by guided M-mode echocardiography. To our knowledge, this is the first Egyptian study to report the echocardiographic reference ranges of donkeys (E. asinus) based on the probability theory and statistics, the coefficient of variation. The results of the present study can be used as standard and reference values for further echocardiographic studies in donkeys and represent a step in the identification, interpretation, and evaluation of cardiovascular disorders in such animals.  相似文献   

4.
Normal cats and cats with congestive cardiomyopathy (CCM) and hypertrophic cardiomyopathy (HCM) were examined using M-mode echocardiography to determine its diagnostic capabilities. Sixteen normal cats were examined to verify previously reported data and to add further echocardiographic inforamtion (left atrial/aortic root ratio, left posterior wall thickness at end systole and end diastole, amplitude of mitral valve excursions, and velocity of valve opening and closure) to aid in differential diagnosis. Significant (p<0.05) changes were detected between the normal cats and those with cardiomyopathy. In each type of cardiomyopathy, alterations in left atrial dimension, left atrial/aortic root ratio, left ventricular dimension, left ventricular wall thickness and percentage of ventricular dimensional change were identified. Altered mitral valve motion was found with HCM. Echocardiography was found to be an accurate technique for definitive diagnosis of feline cardiomyopathy.  相似文献   

5.
OBJECTIVE: To describe and analyze the left ventricular free wall (LVFW) radial and longitudinal motions in a population of healthy Maine Coon cats by use of quantitative 2-dimensional color tissue Doppler imaging (TDI). ANIMALS: 23 healthy young Maine Coon cats (mean +/- SD: age, 2.1 +/- 0.9 years; weight, 5.0 +/- 1.0 kg). PROCEDURE: TDI was performed by the same trained observer (VC) on all cats. Radial LVFW velocities were recorded in endocardial and epicardial LVFW segments, and longitudinal velocities were recorded in the mitral annulus and in basal and apical LVFW segments. Isovolumic contraction and relaxation times were calculated in each myocardial segment, and the coefficients of variation (CVs; %) were determined for each TDI parameter. RESULTS: LVFW velocities were significantly higher in the endocardial layers than in the epicardial layers and also significantly higher in the basal than in the apical segments. Annular velocities were significantly higher than basal myocardial velocities in systole and early diastole. Coefficient of variation values were lower for radial velocities, particularly in systole, and were also lower for time intervals (16% to 22%) than for myocardial velocities (19% to 62%). CONCLUSIONS AND CLINICAL RELEVANCE: Because Maine Coon cats are predisposed to an inherited hypertrophic cardiomyopathy, which is a common cause of death in this breed, TDI could provide a useful tool for early detection of the disease. Tissue Doppler imaging indices may complete the conventional analysis of the left ventricular function in Maine Coon cats. However, the usefulness of TDI indices in the early detection of myocardial dysfunction needs to be clarified.  相似文献   

6.
M-mode echocardiograms were recorded from 40 healthy dogs, awake and unsedated, in left lateral recumbent position. Fifteen echocardiographic measurements were taken and correlated with body weights using linear regression equations. The left ventricular internal dimension in systole and diastole, the left ventricular wall thickness, the aortic root dimension, and the left atrial dimension had high correlation coefficients (r2), ranging from 0.756 to 0.619. The fractional shortening of the left ventricle in systole (39% +/- 6%) and the left atrial to aortic root ratio (0.99 +/- 0.10) were not linearly related to body weights and had constant values.  相似文献   

7.
The aim of the study was to establish normal echocardiographic values of healthy Standardbred trotters not published previously. Twenty-three clinically normal horses weighing between 350 and 490 kg were examined in the same manner: first a thorough physical and then detailed echocardiographic examination were performed. Standardised two-dimensional (2D) and guided M-mode echocardiographic imaging techniques were used to measure interventricular septal thickness (IVS), left ventricular internal diameter (LVID), left ventricular wall thickness (LVW), left atrial internal diameter (LAID) in end-systole (s) and end-diastole (d) and aortic diameter (AOD) in end-diastole. Mean, range and standard deviation of the different parameters were calculated. The mean values (in centimetres) were as follow (2D/M-mode): IVSs: 4.6/4.7; IVSd: 3.1/3.0; LVIDs: 7.0/7.0; LVIDd: 10.7/10.7; LVWs: 3.9/3.9; LVWd: 2.7/2.7; LAIDs: 10.4/-; LAIDd: 11.3/-; AODd: 7.2/-. Results of two-dimensional and M-mode measurements were compared to each other and to normal values obtained from other breeds.  相似文献   

8.
In healthy cats sedated with a combination of ketamine hydrochloride and acepromazine, the reproducibility of sequential echocardiographic examinations was studied. The effects of experimental alteration in heart rate, contractility, and preload on the echocardiogram also were studied. Ten cats had M-mode echocardiograms recorded once weekly for 5 weeks. There were no statistically significant differences in echocardiographic measurements over time, although measurements of certain cardiac structures of an individual cat did vary from time to time. The cardiovascular system was altered by a constant infusion of isoproterenol, followed by a rapid intravenous infusion of isotonic fluid equal to 25% of the calculated blood volume, and then by a rapid withdrawal of blood equal to the amount of fluid previously given. Cardiac output using indocyanine green dilution curves were determined for each treatment and compared to the cardiac output calculated from the echocardiogram. The correlation coefficient was 0.90 for all treatments. During the infusion of isoproterenol a significant increase in the percent fractional shortening and left ventricular wall amplitude occurred compared to the control echocardiogram. After the rapid infusion of fluid, none of the mean echocardiographic measurements significantly changed from control values although the left ventricular chamber diameter at systole significantly increased, and the percent fractional shortening significantly decreased, when compared to values obtained during isoproterenol infusion. Significant changes recorded between echocardiographic measurements made after blood withdrawal compared to those made after fluid loading included an increase in left ventricular wall thickness at diastole, a decrease in left ventricular diameter at diastole, and a decrease in the present left ventricular wall thickening. Cats were terminated and the average of measurements made during the repeatability study of the septal and left ventricular wall thickness during systole, rather than during diastole, more closely approximated the postmortem measurements.  相似文献   

9.
Change in M-mode echocardiographic values in cats given ketamine   总被引:1,自引:0,他引:1  
Determination was made of changes in heart rate and certain M-mode echocardiographic values in healthy cats given ketamine (3 to 5 mg/kg, IM). Heart rate and septal and left ventricular posterior wall thickness in diastole increased, and left ventricular internal diameter in diastole and shortening fraction decreased (P less than 0.02) after ketamine was given. With the adjustment for heart rate by analysis of covariance, left ventricular internal diameter in diastole, shortening fraction, and velocity of circumferential fiber shortening were significantly decreased (P less than 0.05) from base-line values.  相似文献   

10.
BACKGROUND: Diagnosis of cardiomyopathy of cats is based on 2-dimensional (2D) echocardiography. However, circulating fluid volume largely determines diastolic cardiac chamber dimensions, and reduced diastolic volume in other species results in what has been called "pseudohypertrophy of the ventricular myocardium." HYPOTHESIS: Altered hydration produces changes on 2D echocardiography that may confound the diagnosis or severity assessment of cardiomyopathy of cats. ANIMALS: Ten normal colony-sourced mixed breed cats were included. METHODS: Cats were examined by echocardiography at baseline and at completion of 3 protocols (volume depletion and maintenance-rate and anesthetic-rate IV fluid administration) applied in randomized crossover design with a 6-7 day washout period. RESULTS: Volume depletion increased diastolic left ventricular interventricular septal (IVSd) and free wall diameter (4.5 +/- 0.4 to 5.8 +/- 0.6 mm; P < .001) with wall thickness exceeding 6 mm in 4 cats. Diastolic left ventricular internal diameter (LVIDd) decreased, and reduction in systolic left ventricular internal diameter (LVIDs) produced end-systolic cavity obliteration in 7 cats. Left-atrial-to-aortic-root ratio (LA: Ao, 1.4 +/- 0.2 to 1.2 +/- 0.1, P < .05) and left atrial area in diastole (LAAd) decreased with volume depletion. Maintenance-rate IV fluid administration increased LAAd and fractional shortening (FS%). Anesthetic-rate IV fluid administration increased LVIDd, FS%, LAAd, and LA:Ao ratios (to 1.7 +/- 0.1, P < .01), producing an LA: Ao ratio above normal limits in 6 cats. A systolic heart murmur developed with administration of fluid at maintenance (n = 1) and anesthetic rates (n = 6). CONCLUSIONS: Altered hydration status produces changes in the echocardiographic examination of normal cats that may lead to an erroneous diagnosis of cardiomyopathy or mask its presence. Hydration status should be considered during echocardiographic examination in cats.  相似文献   

11.
OBJECTIVE: To analyze velocities of the annulus of the left atrioventricular valve and left ventricular free wall (LVFW) in a large population of healthy cats by use of 2-dimensional color tissue Doppler imaging (TDI). ANIMALS: 100 healthy cats (0.3 to 12.0 years old; weighing 1.0 to 8.0 kg) of 6 breeds. PROCEDURE: Radial myocardial velocities were recorded in an endocardial and epicardial segment, and longitudinal velocities were recorded in 2 LVFW segments (basal and apical) and in the annulus of the left atrioventricular valve. RESULTS: LVFW velocities were significantly higher in the endocardial than epicardial layers and significantly higher in the basal than apical segments. For systole, early diastole, and late diastole, mean +/- SD radial myocardial velocity gradient (MVG), which was defined as the difference between endocardial and epicardial velocities, was 2.2 +/- 0.7, 3.3 +/- 1.3, and 1.8 +/- 0.7 cm/s, respectively, and longitudinal MVG, which was defined as the difference between basal and apical velocities, was 2.7 +/- 0.8, 3.1 +/- 1.4, and 2.1 +/- 0.9 cm/s, respectively. A breed effect was documented for several TDI variables; therefore, reference intervals for the TDI variables were determined for the 2 predominant breeds represented (Maine Coon and domestic shorthair cats). CONCLUSIONS AND CLINICAL RELEVANCE: LVFW velocities in healthy cats decrease from the endocardium to the epicardium and from the base to apex, thus defining radial and longitudinal MVG. These indices could complement conventional analysis of left ventricular function and contribute to the early accurate detection of cardiomyopathy in cats.  相似文献   

12.
A retrospective study was performed in 75 hypertensive cats to determine the spectrum and frequency of M-mode echocardiographic abnormalities. Results indicated that 21.3% of the cats had M-mode measurements within normal reference ranges. For cats with echocardiographic abnormalities, changes were variable. Thirty-nine percent of hypertensive cats had hypertrophy of the interventricular septum in diastole, and 41.3% had hypertrophy of the left ventricular (LV) posterior wall in diastole. One cat in five had a dilated left atrium, while fractional shortening and LV internal dimension in diastole were normal in 82.7% and 86.7% of the cats, respectively. The marked variability of echocardiographic findings in hypertensive cats made echocardiography an unreliable screening test for hypertension.  相似文献   

13.
OBJECTIVE: To evaluate the effects of positioning and number of repeated measurements on intra- and interobserver variability of echocardiographic measurements in dogs. DESIGN: Prospective study. ANIMALS: 4 healthy dogs. PROCEDURE: Each observer performed 24 examinations, separately assessing each dog 6 nonconsecutive times (3 times with the dog in lateral recumbency and 3 with the dog in a standing position). Variables evaluated included M-mode measurements of left ventricular end-diastolic and left ventricular end-systolic diameters, left ventricular free-wall thickness in diastole and systole, interventricular septal thickness in diastole and systole, left ventricular shortening fraction, and 2-dimensional measurements of the left atrial diameter-to-aortic diameter ratio. RESULTS: All coefficients of variation (range, 3.4% to 26.6%) were similar between operators and positions and were < 15% for 27 of 32 values. For both operators, repeatability of the measurements was better for left ventricular end-systolic diameter, left ventricular free-wall thickness in diastole, left ventricular free-wall thickness in systole, and the left atrial diameter-to-aortic diameter in the standing position, and similar for both positions for shortening fraction and left ventricular end-diastolic diameter. No effect of cardiac cycle was observed. CONCLUSIONS AND CLINICAL RELEVANCE: Within-day variability of conventional echocardiography performed with the dog in the standing position was at least as good as that obtained with the dog in lateral recumbency for most measured variables. Single measurements of each variable may be sufficient for trained observers examining dogs that do not have an arrhythmia. The standing position should be used, particularly for stressed or dyspneic dogs.  相似文献   

14.
OBJECTIVE: To evaluate by echo- and electrocardiography the cardiac effects of sedation with detomidine hydrochloride, romifidine hydrochloride or acepromazine maleate in horses. STUDY DESIGN: An experimental study using a cross-over design without randomization. ANIMALS: Eight clinically normal Standardbred trotters. MATERIALS AND METHODS: Echocardiographic examinations (two-dimensional, guided M-mode and colour Doppler) were recorded on five different days. Heart rate (HR) and standard limb lead electrocardiograms were also obtained. Subsequently, horses were sedated with detomidine (0.01 mg kg(-1)), romifidine (0.04 mg kg(-1)) or acepromazine (0.1 mg kg(-1)) administered intravenously and all examinations repeated. RESULTS: Heart rate before treatment with the three drugs did not differ significantly (p = 0.98). Both detomidine and romifidine induced a significant decrease (p < 0.001) in HR during the first 25 minutes after sedation; while acepromazine had a varying effect on HR. For detomidine, there was a significant increase in LVIDd (left ventricular internal diameter in diastole; p = 0.034) and LVIDs (left ventricular internal diameter in systole; p < 0.001). In addition, a significant decrease was found in IVSs (the interventricular septum in systole; p < 0.001), LVFWs (the left ventricular free wall in systole; p = 0.002) and FS% (fractional shortening; p < 0.001). The frequency of pulmonary regurgitation was increased significantly (p < 0.001). Romifidine induced a significant increase in LVIDs (p < 0.001) and a significant decrease in IVSs (p < 0.001) and FS% (p = 0.002). Acepromazine had no significant effect upon any of the measured values. CONCLUSIONS: and clinical relevance The results indicate that sedation of horses with detomidine and to a lesser extent romifidine at the doses given in this study has a significant effect on heart function, echocardiographic measurements of heart dimensions and the occurrence of valvular regurgitation. Although the clinical significance of these results may be minimal, the potential effects of sedative drugs should be taken into account when echocardiographic variables are interpreted in clinical cases.  相似文献   

15.
Echocardiographic values in the Greyhound   总被引:1,自引:0,他引:1  
SUMMARY Serial B- and M-mode echocardiography was performed on Greyhounds to determine normal cardiac values for this breed. These were generally of greater magnitude than predicted from previous echocardiographic research on other breeds and crossbreeds. In particular, left ventricular posterior wall thickness, measured at both systole and diastole, was consistently greater.  相似文献   

16.
OBJECTIVE: To determine M-mode and Doppler echocardiographic reference values in healthy New Zealand white rabbits. ANIMALS: 52 healthy male rabbits. PROCEDURES: The rabbits were anesthetized and M-mode measurements of the left ventricle, left atrium, and aorta and Doppler measurements of pulmonary and aortic outflow and mitral inflow were recorded. RESULTS: Mean +/- SD heart rate during echocardiographic examination was 155 +/- 29 beats/min. Mean +/- SD measurements in diastole and systole for the interventricular septum thickness, left ventricular internal diameter, and left ventricular free wall thickness were 2.03 +/- 0.37 mm and 3.05 +/- 0.45 mm; 14.37 +/- 1.49 mm and 10.25 +/- 1.22 mm; and 2.16 +/- 0.25 and 3.48 +/- 0.55 mm, respectively. Mean +/- SD left atrial-to-aortic diameter ratio was 1.17 +/- 0.14, and mean +/- SD mitral valve E-point-to-septal separation interval was 1.71 +/- 0.29 mm. Mean +/- SD for fractional shortening and ejection fraction were 30.13 +/- 2.98% and 61.29 +/- 4.66%, respectively. Mean +/- SD maximal aortic and pulmonary artery outflow velocities were 0.85 +/- 0.11 m/s and 0.59 +/- 0.10 m/s, respectively, and the peak E-to-peak A wave velocity ratio of the mitral valve was 2.19 +/- 0.46. CONCLUSIONS AND CLINICAL RELEVANCE: Results provide echocardiographic reference values for young adult male New Zealand white rabbits anesthetized with ketamine and medetomidine. Values obtained from unanesthetized rabbits, rabbits sedated with other agents, or rabbits of different size may differ from those reported here.  相似文献   

17.

Background

Maine coon cats have a familial disposition for developing hypertrophic cardiomyopathy (HCM) with evidence of an autosomal dominant mode of inheritance [1]. The current mode to diagnose HCM is by use of echocardiography. However, definite reference criteria have not been established. The objective of the study was to determine the prevalence of echocardigraphic changes consistent with hypertrophic cardiomyopathy in Swedish Maine coon cats, and to compare echocardiographic measurements with previously published reference values.

Methods

All cats over the age of 8 months owned by breeders living in Stockholm, listed on the website of the Maine Coon breeders in Sweden by February 2001, were invited to participate in the study. Physical examination and M-mode and 2D echocardiographic examinations were performed in all cats.

Results

Examinations of 42 asymptomatic Maine coon cats (10 males and 32 females) were performed. The age of the cats ranged from 0,7 to 9,3 years with a mean of 4,8 ± 2,3 years. Four cats (9,5%) had a diastolic interventricular septal (IVSd) or left ventricular free wall (LVPWd) thickness exceeding 6,0 mm. In 3 of these cats the hypertrophy was segmental. Two cats (4,8%) had systolic anterior motion (SAM) of the mitral valve without concomitant hypertrophy. Five cats (11,9%) had IVSd or LVPWd exceeding 5,0 mm but less than 6,0 mm.

Conclusion

Depending on the reference values used, the prevalence of HCM in this study varied from 9,5% to 26,2%. Our study suggests that the left ventricular wall thickness of a normal cat is 5,0 mm or less, rather than 6,0 mm, previously used by most cardiologists. Appropriate echocardiographic reference values for Maine coon cats, and diagnostic criteria for HCM need to be further investigated.  相似文献   

18.
Scaling in biology is usually allometric, and therefore, the size of the heart may be expressed as a power function of body weight (BW). The present research analyses the echocardiographic measurements in 68 healthy Spanish foals weighed between 70 and 347 kg in order to determine the correct scaling exponent for the allometric equation. The echocardiographic parameters measured were: left ventricular internal dimensions (LVID), free wall thickness (LVFWT), interventricular septum thickness (IVST) at systole (s) and diastole (d), EPSS (distance between the point E of the mitral valve and the interventricular septum), and aorta diameters at the level of the aortic valve (AOD), base of valve leaflets (ABS), sinus of Valsalva (ASV) and sino-tubular junction (AJT). Indices of left ventricular performance were calculated. It was found that LVIDd, IVSTs, AOD, and ASV have a relationship to BW raised to 0.300-0.368 power, whereas left ventricular end-diastolic volume and stroke volume scaled to BW raised to 0.731-0.712 power. With these data, appropriate values can be calculated for normal Spanish foals.  相似文献   

19.
Left ventricular hypertrophy signals a poor prognosis in hypertensive humans. Cardiac disease is common in cats with systemic hypertension. The aims of this study were to characterize the echocardiographic findings of cats with systemic hypertension and to determine if reducing the degree of hypertension is associated with resolution of cardiac hypertrophy. Echocardiographic examinations were performed on 19 cats with naturally occurring systemic hypertension. Fourteen of these cats were subsequently studied after a minimum of 3 months of treatment with the antihypertensive agent amlodipine. Hypertensive cats had a significantly thicker interventricular septum in both systole and diastole, thicker left ventricular free wall in both systole and diastole, and larger left atrium compared to the published normal values and 74% (14/19) of the cats met criteria for left ventricular hypertrophy (diastolic septal or free-wall thickness > 0.60 cm). Systolic blood pressure was lower after treatment (217 +/- 25 mm Hg, range: 180-275 mm Hg; and 142 +/- 27 mm Hg, range: 90-200 mm Hg). No difference was found in any of the echocardiographic measurements between the untreated and treated cats, although more cats had ventricular hypertrophy before treatment (11/14) than after initiating amlodipine (6/14; P = .006). Ventricular hypertrophy is common in hypertensive cats and may resolve after the initiation of amlodipine.  相似文献   

20.
The purpose of this prospective study was to determine comparability of left ventricular (LV) M-mode echocardiographic indices derived from right parasternal long-axis and short-axis imaging planes. In 104 dogs (37 healthy dogs and 67 dogs with heart disease), LV M-mode echocardiograms were recorded from both long-axis and short-axis views and interventricular septum thickness (IVS), left ventricular internal dimensions (LVD), left ventricular posterior wall thickness (LVPW), and LV shortening fraction (FS) were measured. Statistical analysis included paired t-test and graphical analysis to assess agreement between the two methods of data acquisition. Mean LVD in systole and diastole and mean IVS in systole were significantly (P<0.001) larger when measured from short-axis recordings compared to long-axis measurements. An increased magnitude of measurement resulted in increased differences between the methods for LV dimensions and fractional shortening. Differences between the two methods were small and within clinically acceptable limits in normal dogs. However, in 23 (34%) of the dogs with cardiac abnormality, one or more LV M-mode derived dimension obtained from one imaging plane did not agree sufficiently closely with the same measure from the other plane. Only for measurement of FS was there good agreement between methods in dogs with cardiac disease. Therefore, with the exception of FS, data gained from LV short-axis and long-axis M-mode recordings should not be used interchangeably in dogs with cardiac disease.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号