首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The purpose of this study was to estimate the performance characteristics (accuracy, detection limit, and precision) of commercially available enzyme-linked immunosorbent assay (ELISA) and agar gel immunodiffusion (AGID) kits in comparison with a reference AGID kit for the detection of equine infectious anemia (EIA) antibodies in horses for regulatory use in Canada. A total of 285 positive and 315 negative samples by the reference AGID were tested blindly on 2 other AGID and 4 ELISA kits. Commercially available AGID kits for the serodiagnosis of EIA were found equivalent. The 3 ELISAs directed against antibodies to the p26 core protein also performed relatively well in comparison with the reference AGID, with excellent relative accuracy and acceptable precision. The single ELISA directed against antibodies to the gp45 trans-membrane viral protein yielded a lower relative sensitivity. The performance characteristics of the ELISAs directed against antibodies to p26 are, therefore, adequate to support the implementation of ELISA for regulatory purposes in Canada.  相似文献   

2.
3.
Three peptides derived from the equine infectious anemia virus (EIAV) surface proteins were synthesized to design and validate an ELISA for EIA diagnosis. Peptides identified as gp90-I and gp90-II correspond to the N- and C-terminal part of the surface glycoprotein gp90. Peptide gp45-1 overlaps the immunodominant epitope CIERTHVFC of the transmembrane glycoprotein gp45, and includes a hydrophilic chain close to the N-terminal end of this nonapeptide loop. Serum samples from 140 naturally infected horses with EIAV and a panel of 167 non-immune equine sera obtained from non-infected animals were used. Differences in reactivity between positive and negative serum samples were clearly distinguished. Samples considered weak positive to the agar gel immunodiffusion (AGID) test were "true" positive in the ELISA. These results are consistent with the improved sensitivity of the ELISA in comparison with the AGID test. The cyclic peptide that mimics the immunodominant sequence of gp45 showed excellent reactivity, thus suggesting that its functional activity depends significantly on its conformation, since very low reactivity was observed in the linear form of the peptide. The detectability indices of positive and negative sera reached 98% when gp90-II and gp45-I synthetic peptides were used in the same assay, illustrating the high specificity and sensitivity of the assay. Our study represents a first approach for the design of a diagnostic kit, which would allow the rapid analysis of a large numbers of serum samples from horses, and could be applied in endemic areas with different prevalence of infection.  相似文献   

4.
Equine infectious anemia (EIA) is a highly infectious disease in members of the Equidae family, caused by equine infectious anemia virus (EIAV). The disease severity ranges from subclinical to acute or chronic, and causes significant economic losses in the equine industry worldwide. Serologic tests for detection of EIAV infection have some concerns given the prolonged seroconversion time. Therefore, molecular methods are needed to improve surveillance programs for this disease. We attempted detection of EIAV in 6 clinical and 42 non-clinical horses in Nuevo Leon State, Mexico, using the agar gel immunodiffusion (AGID) test for antibody detection, and nested and hemi-nested PCR for detection of proviral DNA. We found that 6 of 6, 5 of 6, and 6 of 6 clinical horses were positive by AGID, nested PCR, and hemi-nested PCR, respectively, whereas 0 of 42, 1 of 42, and 9 of 42 non-clinical horses were positive by these tests, respectively. BLAST analysis of the 203-bp 5′-LTR/tat segment of PCR product revealed 83–93% identity with EIAV isolates in GenBank and reference strains from other countries. By phylogenetic analysis, our Mexican samples were grouped in a different clade than other sequences reported worldwide, indicating that the LRT/tat region represents an important target for the detection of non-clinical horses.  相似文献   

5.
An enzyme-linked immunosorbent assay (ELISA) test was developed for the detection of specific antibodies against the unique infectious anemia (EIA) virus in equine sera. The ELISA test was faster and more sensitive when compared with the classic test of agar gel immunodiffusion (AGID). A total of 200 sera were tested: 100 from negative horses and 100 from positive horses by AGID. The ELISA test showed 92 horse sera negative and 100 horse sera positive by AGID with values of optical density (OD) less than 0.139 and higher than 0.139, respectively. Eight horse sera were negative by AGID and higher than 0.139 by ELISA. Six of these became AGID positive also when re-tested 30 days later, and two were of the horses that showed clinical signs of EIA and died before re-testing.  相似文献   

6.
我国从20世纪70年代开始使用EIAV弱毒疫苗后,在全国范围内基本控制了马传贫的发生,我们从现地少数EIAV琼扩阳性马外周血中扩增并克隆了二株EIAV前病毒5'LTR序列,并与国内外毒株5'LTR序列进行了比较分析,发现中国EIAV LTR特有的特异性细胞转录因子结合基序,同时发现PEA2位点不是强毒特有的基序,在弱毒中亦发现该基序.  相似文献   

7.
Two diagnostic tests are approved for detecting antibody to equine infectious anemia virus: the agar-gel immunodiffusion (AGID) test and the competitive enzyme-linked immunosorbent assay (ELISA). A total of 420 sera from National Veterinary Services Laboratories check sets were tested with the AGID and competitive ELISA. A 100% correlation was obtained. The AGID and competitive ELISA were further used to test difficult samples with low levels of equine infectious anemia antibody (weak positives). A third test (Western blot) was also used with these weak positive samples to resolve any discordant results.  相似文献   

8.
用昆虫杆状病毒表达系统获得的马传染性贫血病病毒( E I A V) 核心蛋白( Gag) 和 P26 蛋白, 作为免疫琼脂双扩散( A G I D) 和酶联免疫吸附试验( E L I S A) 抗原。对76 份已知马传贫非特异性血清进行检查, 同时与市售 A G I D 和 E L I S A 试剂盒作比较。证明, 用表达蛋白作抗原的 A G I D 和 E L I S A 检测结果均为阴性反应, 而用市售 A G I D 试剂盒检查有54 份马血清出现非特异性反应, 市售 E L I S A 试剂盒检查也出现了非特异性反应, O D 值比表达抗原 E L I S A 高35 倍。初步证明在 A G I D 和 E L I S A 法中, 表达抗原优于常规马传贫病毒抗原。  相似文献   

9.
Precipitin lines not associated with equine infectious anemia (EIA) were observed in routine agar gel immunodiffusion (AGID) testing for the infection. The serums which produced these lines were obtained from horses which had been given multiple vaccinations with commercially available cell culture-origin equine virus vaccines as part of a comprehensive herd health program. The lines formed against cell culture-derived, but not spleen-derived EIA viral antigens. Investigation revealed that bovine serum proteins in the vaccines induced precipitating antibodies which reacted with bovine serum proteins in cell culture-derived antigens. A vaccination trial, utilizing 4 commercially available vaccines in various combinations, indicated that as few as 2 vaccinations could induce AGID-detectable antibodies to bovine serum proteins in individual ponies. These antibodies were very transitory, usually lasting no longer than a week. Some horses, however, which had been given 4 vaccinations developed similar antibodies which persisted 3 months beyond the last vaccination. The extraneous precipitin lines produced by these antibodies in the AGID test for EIA were readily distinguished from true EIA-associated reactions and did not result in false-positive interpretations of the test. However, heavy percipitin lines due to strong antibovine serum activity did mask weakly positive EIA reactions.  相似文献   

10.
The enzyme-linked immunosorbent assay (ELISA) antigen-positive and agar-gel immunodiffusion test (AGID)-negative horses do not have infective equine infectious anemia (EIA) virus. The ELISA testing of horse leukocyte culture (HLC) supernatants did detect EIA virus in a HLC that was infected with the Wyoming strain of EIA virus and in HLC derived from horses in febrile, acute, or subacute stages of EIA infection. In supernatants of HLC derived from chronic and inapparent carrier horses, EIA virus was not detected with ELISA. Direct fluorescent antibody tests detected EIA virus in HLC infected with 10(6)TCID50 of the Wyoming strain of EIA virus and in 50% of the HLC from febrile acute or subacute horses. The direct fluorescent antibody testing of HLC derived from chronic and inapparent carrier horses did not detect cell-associated EIA virus. The pony inoculation test proved to be the most reliable and accurate method for detecting infective EIA virus in horses in various stages of EIA infection and accurately correlated with the AGID test.  相似文献   

11.
An indirect enzyme-linked immunosorbent assay (ELISA) was developed for the detection of equine infectious anemia (EIA) antibody in horse sera. Purified P26 viral protein was the antigen; alkaline phosphatase linked to rabbit anti-horse immunoglobulin G was the conjugate. The ELISA detected EIA antibodies in horse sera as early as 11 to 14 days after experimental inoculations. There was full agreement between the results of ELISA and the agar-gel immunodiffusion tests on EIA proficiency test sera. The ELISA readily detected EIA antibody in horse sera that had weak positive reactions on agar-gel immunodiffusion.  相似文献   

12.
In this study, 162 horses, 80 donkeys and 51 mule serum samples were collected in Konya city. Additionally, 64 horse serum samples from Ankara and 49 samples from Kayseri city were included in the study. A total of 406 serum samples were examined by agar gel immunodiffusion (AGID) and enzyme-linked immunosorbent assay (ELISA) for antibody to equine infectious anaemia virus (EIAV) and no positive result was detected.  相似文献   

13.
Progeny of a band of horses, positive by the agar-gel immunodiffusion (AGID) test for equine infectious anemia (EIA) antibody, were observed through their weaning over a 4-year period. Sentinels (AGID test-negative) were allowed to mingle with EIA-infected mares and their foals in pasture situations in an area with high populations of potential vectors. Of 27 adult sentinels, 8 (30%) seroconverted in annual rates ranging from 0% to 75%. In contrast, only 2 of 31 (6%) foals weaned became infected. Difference in infection rates between adult sentinels and foals was significant (chi 2, P less than 0.05). Possible explanations for differences included protective value of colostral immunity and differences in attractiveness to blood feeding vectors. Detectable colostral immunity to EIA virus in the AGID test persisted for 25 to 195 days, with a mean of 124 days.  相似文献   

14.
从感染驴白细胞的马传贫驴白细胞弱毒疫苗株前病毒DNA中克隆了编码跨膜蛋白主要免疫决定区(TMIR)的基因,并在大肠杆菌中进行了表达。所表达的融合蛋白有一部分是可溶的,其氨基端带有6个组氨酸的标签,因此可以用固定化金属离子亲和层析法在非变性条件下进行纯化。在间接酶联免疫吸附试验(ELISA)和免疫印迹试验中,重组的TMIR蛋白可与马传贫阳性血清样品发生反应,而与健康马血清无任何反应。这表明该重组蛋白具有良好的抗原性和特异性,可用于马传贫弱毒疫苗株在体内外复制、接种马体内免疫应答及马传贫诊断的研究。  相似文献   

15.
为制备马传染性贫血病毒(EIAV)的单克隆抗体(MAb),本研究以原核表达并纯化的EIAV p26蛋白作为免疫原免疫8周龄的BALB/c小鼠,利用淋巴细胞杂交瘤技术,建立抗EIAV衣壳蛋白p26抗体的杂交瘤细胞.应用重组p26蛋白为抗原建立ELISA筛选方法,获得两株能够稳定分泌特异性MAb的杂交瘤细胞株,分别命名为E11和F8.经试验证明,这些抗p26MAb均能够与感染驴胎皮肤细胞的EIAV和经SDS-PAGE分离的EIAV总蛋白中的p26蛋白结合.这两株p26蛋白MAb的获得将为EIAV的检测及鉴别诊断奠定基础.  相似文献   

16.
马传贫驴白细胞弱毒疫苗株基质蛋白基因的克隆与表达   总被引:5,自引:0,他引:5  
从感染驴白细胞的马传贫驴白细胞弱毒疫苗株前病毒DNA中克隆了编码基质蛋白(p15)的基因,并在大肠杆菌中进行了表达,所表达的蛋白是一种可溶性的融合蛋白,其氨基端带有6个组氨酸的标签,因此可以用固定化金属离子亲和层析法在非变性条件下进行纯化,在间接ELISA和免疫印迹试验中,重组的基质蛋白可与马传贫阳性血清样品发生反应,而与健康马血清无任何反应,这表明该重组蛋白具有良好的抗原性和特异性,可用于马传贫弱毒疫苗株在体内外复制及在接种马体人免疫应答的研究中。  相似文献   

17.
We used a p26 recombinant protein (p26r) from equine infectious-anemia virus (EIAV) expressed in Escherichia coli as antigen to standardize an agar-gel immunodiffusion (AGIDp26r) test and an indirect ELISA (ELISAp26r) for the detection of antibodies against EIAV in 720 equine sera from Brazil. We evaluated the tests's relative diagnostic sensitivities (relSe) and relative diagnostic specificities (relSp) against a commercial AGID kit (Idexx™, USA). We used three sera panels: panel A—196 AGID-negative sera from an AIE non-endemic controlled area; panel B—194 AGID-negative sera from an AIE endemic area and panel C—330 AGID-positive sera from an AIE endemic area. ELISAp26r cut-off value was defined with TG-ROC using sera from panels A and C. AGIDp26r showed an agreement of 100% with the commercial kit. When applied to sera from panels A and C, ELISAp26r showed an agreement of 100% with the kit, but, although relSe was 100% for panel C, the ELISAp26r had relSp of 93.3%.  相似文献   

18.
An equine dermal cell line between the 14th and 30th subpassages was used to develop a reproducible method of titrating the infectivity of the cell-adapted strain of equine infectious anemia virus (EIAV). Cells inoculated with EIAV were subcultured or fed once each week and were monitored for the production of P26 antigen of EIAV in supernatant fluids. Ultrathin sections were prepared once each week and were examined for the detection of budding virus-like particles (VLP). The VLP could not be detected in the infected cells subcultured once each week. When the medium was changed once week and when the cells not transferred, budding VLP were detected routinely after 3 to 4 weeks, Feeding of the infected cells once each week was used to establish the infectivity assay. The reproducibility of the assay on a frozen viral stock preparation was within an endpoint of one tenfold dilution.  相似文献   

19.
Equine infectious anaemia is a retroviral infection of horses. All infected horses, including those that are asymptomatic, become carriers and are infectious for life. In this study, blood samples of all equines in the province of Ardahan were collected. The material consisted of 8,947 equines, including 8,769 horses and 178 donkeys, from Ardahan province in northeastern Turkey. Blood was collected from all horses and donkeys and the sera were analysed for the presence of antibodies to equine infectious anaemia virus (EIAV) using an enzyme-linked immunosorbent assay. The results revealed that none of the horses and donkeys were positive for antibodies to EIAV.  相似文献   

20.
以灭活马流感病毒(EIV)A/Equine/Jilin/1/1989(H3N8)为免疫原,免疫Balb/c小鼠,经常规细胞融合后,用血凝抑制试验(H1)和间接ELISA方法筛选获得3株(3C2、5G10和5A10)能稳定分泌H3N8亚型马流感病毒单克隆抗体(mAb)的杂交瘤细胞株.其中3C2和5G10为IgG2α,5A...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏