首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Nine laboratories participated in a collaborative study on determination of crude protein in animal feeds to compare a generically described combustion method with the AOAC mercury catalyst Kjeldahl method (7.015). The combustion method was written in general terms of method principle, apparatus specifications, and performance requirements. The sample set comprised closely matched pairs of feed ingredients and mixed products ranging from 10 to 90% protein. Ten pairs ground to 0.5 mm were the focus of the study; 4 pairs were ground to 1.0 mm for comparison. Nicotinic acid and lysine monohydrochloride were included as standards. Collaborators were instructed to report their results for performance checks using materials supplied. Only one laboratory failed to meet the proposed limits. Seven laboratories used the LECO Model FP-228 analyzer and 2 used the LECO CHN 600 analyzer. For the 0.5 mm pairs, repeatability standard deviations (Sr) ranged from 0.09 to 0.58 for the Kjeldahl method and from 0.14 to 0.33 for the combustion method, with a pooled Sr value of 0.28 and relative standard deviation (RSDr) of 0.59%. Reproducibility standard deviations (Sg) ranged from 0.23 to 0.86 (Kjeldahl) and from 0.30 to 0.61 (combustion), with a pooled Sg value of 0.52 and RSDg of 1.10%. Grand means for the samples ground to 0.5 mm were 47.65% protein by the combustion method and 47.41% protein by the Kjeldahl method. For samples ground to 1.0 mm, corresponding values were 31.82 and 31.50% protein. The generic combustion method has been approved interim official first action.  相似文献   

2.
Eleven laboratories participated in an interlaboratory study of an enzyme-linked immunoassay for limonin in grapefruit juice. Participating laboratories received training and practice samples until familiar with the procedure. Laboratories then received 8 sample pairs of grapefruit juice as blind duplicates. Samples were refrigerated and analyzed within 4 days of receipt. Results from 1 laboratory and 6 individual samples were excluded from the statistical analysis. Method performance was measured by the one-way component of variance analysis. Repeatability relative standard deviations (RSDr) ranged from 7.0 to 15.6%. Reproducibility relative standard deviations (RSDR) ranged from 12.9 to 29.4%.  相似文献   

3.
Ten laboratories analyzed 9 pairs of blind duplicate raw milk samples for total solids. A direct forced air oven method (4 h at 100 degrees C) and a modification of the AOAC predry method (16.032) were used. Preliminary evaluation of the modified AOAC method indicated that blank determinations were necessary. Total solids content ranged from 12.0 to 14.6%. Average repeatability standard deviations (Sr) of the direct forced air oven and modified AOAC methods were 0.019 and 0.017, respectively. Average reproducibility standard deviations (SR) of the direct forced air oven and the modified AOAC methods were 0.042 and 0.047, respectively. Average repeatability relative standard deviations (RSDr) for the direct forced air oven and the modified AOAC methods were 0.149 and 0.136%, respectively; average reproducibility relative standard deviations (RSDR) were 0.327 and 0.370%, respectively. Mean repeatability values (r) and reproducibility values (R) were 0.054 and 0.118 for the direct forced air oven method and 0.049 and 0.133 for the modified AOAC method, respectively. The mean test result of the direct forced air oven method (12.7293%) was comparable to that for the modified AOAC method (12.7273%). The modification of AOAC method 16.032 and the direct forced air oven method have been approved interim official first action.  相似文献   

4.
Eight laboratories participated in a collaborative study to estimate precision of a standardized rat assay for determining true protein digestibility in selected animal, fish, and cereal products. Each of 7 test protein sources (casein, tuna fish, macaroni/cheese, pea protein concentrate, rolled oats, pinto beans, and nonfat dried milk) was fed as the sole source of protein at a 10% protein level in mixed diets. Each diet was fed to 2 replicate groups of 4 rats each for a 4-day acclimation period and a 5-day balance period. Mean digestibilities ranged from 98.6% for casein to 72.6% for pinto beans. Repeatability standard deviations ranged from 0.5 to 2.0%; the mean relative standard deviation for repeatability was 0.9% (range 0.5-2.8%). Reproducibility standard deviations ranged from 1.2 to 3.2%, and the mean relative standard deviation for reproducibility was 2.4% (range 1.3-4.4%). The method has been approved interim official first action for determining true protein digestibility in foods and ingredients.  相似文献   

5.
A collaborative study was carried out on a solid-phase extraction method for separating volatile N-nitrosamines, particularly N-nitrosodimethylamine (NDMA), from combination minced fish or surimi-meat frankfurters with detection by gas chromatography-chemiluminescence (thermal energy analyzer). The results from the 10 collaborators were evaluated using the most recent AOAC guidelines for determining outliers and for the analysis of variance. For NDMA, repeatability standard deviations, sr, ranged from 0.56 to 2.25; repeatability relative standard deviations, RSDr, ranged from 8.9 to 11.5%. Reproducibility standard deviations, SR, for NDMA ranged from 1.40 to 6.49, and reproducibility relative standard deviations, RSDR, ranged from 24.2 to 28.9%. Our data compared favorably to the reproducibility (RSDR) curve of Horwitz. The method has been adopted official first action by AOAC.  相似文献   

6.
Phytate, a naturally occurring organic compound found in plant seeds, roots, and tubers, was determined in a collaborative study using a modified anion-exchange method. Seven samples (peanut flour, oats, rice, isolated soybean protein, a vegetarian diet composite, wheat bran, and whole wheat bread), supplied as blind duplicate samples, were analyzed in triplicate by 7 collaborators. Phytate concentrations in the samples ranged from 2.38 to 46.70 mg/g. Relative standard deviations (RSD = CV) for repeatability ranged from 2.5 to 10.1%, and for reproducibility, from 4.5 to 11.0%. The method has been adopted official first action.  相似文献   

7.
This collaborative study on the determination of glucose and fructose in wine was performed by 18 laboratories on 4 matched pairs of commercial wine. The method uses the enzymes hexokinase, glucose-6-phosphate dehydrogenase, and phosphoglucose isomerase and the coenzyme nicotinamide-adenine dinucleotide phosphate. Both glucose and fructose can be determined in the same sample without separation. The method is simple but care is necessary to ensure precise transfer of small volumes. Repeatability and reproducibility standard deviations for glucose ranged from 2.6 to 14.6 mg/L and 4.7 to 16.5 mg/L, respectively. Repeatability and reproducibility values for fructose ranged from 2.4 to 16.1 mg/L and 6.0 to 21.3 mg/L, respectively. The method has been adopted official first action.  相似文献   

8.
Nine laboratories analyzed samples of whole grain, intermediate, and ready-to-eat products for ethylene dibromide (EDB) residues. Supplied samples of wheat, rice, and flour contained both fortified and incurred EDB; corn bread mix, baby cereal, and bread contained only fortified EDB. The whole grains and intermediates were analyzed by the same basic procedural steps as in the official method for multifumigants: They were extracted by soaking in acetone-water (5 + 1). The baby cereal and bread were analyzed by a modification of the Rains and Holder hexane co-distillation procedure. EDB was determined by electron capture gas chromatography operated with an SP-1000 column. All products contained 3 different levels of EDB and were analyzed as blind duplicates. Overall mean recoveries ranged from 85.2% for 69.6 ppb to 105.0% for 4.35 ppb, both in baby cereal. Interlaboratory relative standard deviations ranged from 5.7% for 869 ppb in wheat to 20.2% for 69.6 ppb in baby cereal, both fortified. Mean levels of incurred EDB in wheat, rice, and flour were 926.7, 982.0, and 49.9 ppb, respectively; corresponding relative standard deviations were 9.9, 7.7, and 13.1%. The method was adopted official first action.  相似文献   

9.
Each of 10 collaborating laboratories analyzed 4 blind duplicate pairs of forage samples for nitrate, by using a potentiometric method. Two forage controls and a 100 000 mg KNO3/L standard were also provided. Nitrate was extracted into an aqueous Al2(SO4)3 solution containing 70 mg KNO3/L and quantitated with a nitrate-selective electrode. Standards were prepared using extracting solution as diluent. Nitrate concentrations in forage samples ranged from less than 0.50 to 4.35% KNO3. Repeatability coefficients of variation (CVo) ranged from 1.74 to 3.61%, and reproducibility coefficients of variation (CVx) ranged from 6.92 to 7.66%. Mean recovery of a 0.55% KNO3 spike was 94.5%. The method has been adopted official first action.  相似文献   

10.
Eleven collaborating laboratories analyzed 18 blind duplicate pairs of raw milk samples for fat by the Babcock method and by a modified Mojonnier ether extraction method in 7 round robins conducted over a 14 month period. Ten laboratories used the Babcock method and 10 used the modified Mojonnier method. Fat content of samples ranged from approximately 2.7 to 5.6%. Mean test value of samples analyzed was approximately 3.9% fat. Average standard deviations of within-laboratory repeatability (Sr) of the Babcock and ether extraction methods were 0.029 and 0.015% fat, respectively. Average standard deviations of between-laboratory reproducibility (SR) of the Babcock and ether extraction methods were 0.039 and 0.020% fat, respectively. Average repeatability relative standard deviations (RSDr) for the Babcock and ether extraction methods were 0.742 and 0.396%; average reproducibility relative standard deviations (RSDR) were 1.014 and 0.512%, respectively. Mean repeatability values (r) and reproducibility values (R) were 0.081 and 0.111% for Babcock and 0.044 and 0.056% for ether extraction, respectively. The ether extraction method demonstrated consistently better within- and between-laboratory agreement. The overall mean test value for the Babcock method was significantly higher (0.021% fat) than that for ether extraction. The difference between Babcock and ether extraction fat test results was different for different farms. In addition, the mean difference between percent fat determined by the Babcock and ether extraction methods was different in different months. There was no correlation in the difference between Babcock and ether extraction methods with the absolute level of fat in the samples in the range of 2.7 to 5.6% fat. The modifications of the AOAC Babcock method and the modified Mojonnier ether extraction method have been approved interim official first action.  相似文献   

11.
Each of 9 laboratories analyzed 9 pairs of blind duplicate raw milk samples for fat, using the Mojonnier ether extraction method (16.E13-16.E17), and for total solids, using a new direct forced air oven method. Solids-not-fat was determined by subtracting percent fat from percent total solids. The solids-not-fat content of the samples tested in the collaborative study ranged from 8.48 to 9.36%. The average repeatability standard deviation (sr) and the average reproducibility standard deviation (SR) for the solids-not-fat method were 0.019 and 0.041, respectively. Average repeatability (RSDr) and reproducibility (RSDR) relative standard deviations were 0.218 and 0.466%, respectively. The mean repeatability value (r) was 0.055; the mean reproducibility value (R) was 0.117. The difference between milk total solids determined by direct forced air oven drying and milk fat determined by Mojonnier ether extraction has been approved for interim official first action for determination of solids-not-fat content of milk.  相似文献   

12.
In vitro assay for protein digestibility: interlaboratory study   总被引:1,自引:0,他引:1  
True protein digestibilities of 17 protein sources were estimated by 6 laboratories using an in vitro, 3-enzyme digestion system in a pH stat. Samples from animal, vegetable, and mixed food sources were freeze-dried (if not already dried), ground, mixed, and shipped to each collaborator along with a sodium caseinate standard and trypsin, chymotrypsin, and peptidase. The uptake of titrant during enzymatic digestion was used to calculate estimates of digestibility. Digestibilities ranged from 100% for casein to 89.9% for whole wheat cereal. Mean relative standard deviations for repeatability were 1.4% for rolled oats and less than 1% for the remaining 16 samples. Mean relative standard deviations for reproducibility ranged from 5.0 to 0.8%; values were less than 2.5% for 13 of the 17 samples.  相似文献   

13.
A rehydratable dry-film plating procedure for aerobic plate counts has been compared to the standard agar plate method (966.23B and C, 15th ed.; 46.014-46.015, 14th ed.) in a collaborative study by 12 laboratories. Each laboratory analyzed the normal microflora of 3 samples in duplicate for 6 products. The aerobic plate counts ranged from 1.0 x 10(3) to 1.0 x 10(8) cfu/g. The products were flour, nuts, frozen raw shrimp, spice, frozen raw ground turkey, and frozen and refrigerated vegetables. Repeatability standard deviations of the 2 methods did not differ significantly for 13 of 18 test samples. For 1 shrimp and 2 turkey samples, the dry-film method had lower repeatability variances (P less than 0.05) and for 1 spice sample the agar method had lower repeatability variances (P less than 0.05). Relative standard deviations of repeatability were between 1.7 and 15.5% for the dry-film method and 1.2 and 16.0% for the agar method. Relative standard deviations of reproducibility ranged from 2.4 to 23.4% for the dry-film method and 2.3 to 18.8% for the agar method. The dry rehydratable film method has been adopted official first action for determination of the aerobic plate count.  相似文献   

14.
Each of 5 collaborating laboratories determined volatile N-nitrosamines in 3 blind quadruplicate sets of latex rubber infant pacifier samples, using a gas chromatographic-thermal energy analysis (GC-TEA) method. Volatile N-nitrosamines are extracted from cut-up pacifier nipples with CH2Cl2. The extract is concentrated and subjected to high temperature purge and trap, and the nitrosamines are eluted from the trap and determined by GC-TEA. N-Nitrosodibutylamine (NDBA) was the only nitrosamine found in sufficient concentration to allow analysis. NDBA concentrations of the 3 sets of samples were 82.6, 21.0, and 7.12 ng/g rubber. The repeatability relative standard deviations ranged from 7.46 to 24.0% and the reproducibility relative standard deviations from 7.46 to 29.2%. The minimum detectable level of NDBA by this method is 3.6 ng/g rubber. The method has been adopted official first action.  相似文献   

15.
Seven laboratories participated in a collaborative study of a method for determination of phosphorus in meat and meat products. Samples are digested in sulfuric acid and hydrogen peroxide; digestion is complete in approximately 10 min. Phosphorus is determined by colorimetric analysis of a dilute aliquot of the sample digest. The collaborators analyzed 3 sets of blind duplicate samples from each of 6 classes of meat (U.S. Department of Agriculture classifications): smoked ham, water-added ham, canned ham, pork sausage, cooked sausage, and hamburger. The calibration curve was linear over the range of standard solutions prepared (phosphorus levels from 0.05 to 1.00%); levels in the collaborative study samples ranged from 0.10 to 0.30%. Standard deviations for repeatability (sr) and reproducibility (SR) ranged from 0.004 to 0.012 and 0.007 to 0.014, respectively. Corresponding relative standard deviations (RSDr and RSDR, respectively) ranged from 1.70 to 7.28% and 3.50 to 9.87%. Six laboratories analyzed samples by both the proposed method and AOAC method 24.016 (14th Ed.). One laboratory reported results by the proposed method only. Statistical evaluations indicated no significant difference between the 2 methods. The method has been adopted official first action by AOAC.  相似文献   

16.
Eleven collaborating laboratories conducted replicate analyses on 4 blind duplicate pairs of bovine liver samples that either had naturally acquired copper levels or were spiked with one of 3 copper levels. A National Bureau of Standards Bovine Liver sample (SRM 1577, 193 +/- 10 mg copper/kg) and a 1000 mg copper/L standard were also submitted to the collaborators. The method requires the tissue to be digested with concentrated HNO3 at 60 degrees C, diluted to volume with water, and analyzed by atomic absorption spectrophotometry. The intralaboratory coefficients of variation (CVo) ranged from 5.6 to 19%; the interlaboratory CVx values ranged from 7.1 to 21%. The lower limit of detection was estimated to be 1 mg copper/kg tissue. The method has been adopted official first action.  相似文献   

17.
A gas chromatographic method for determination of vapor phase nicotine in environmental tobacco smoke (ETS) was collaboratively studied by 6 laboratories. Nicotine is desorbed from XAD-4 sample tubes with ethyl acetate containing triethylamine and determined by gas chromatography with nitrogen-selective detection. Each collaborator received blind duplicate samples at each of 6 nicotine concentrations. Three concentrations were generated by spiking XAD-4 tubes with known amounts of nicotine; the remaining 3 concentrations were ETS samples obtained in a carefully controlled environmental chamber containing sidestream and exhaled mainstream smoke from 1R4F Kentucky reference cigarettes. Repeatability and reproducibility relative standard deviations ranged from 4.4 to 11.1% and from 7.0 to 11.1%, respectively, for nicotine concentrations evaluated (up to 6 micrograms/cu m). The method has been adopted official first action.  相似文献   

18.
The LECO FP-228 "Nitrogen Determinator" was compared with the AOAC copper catalyst Kjeldahl method, 7.033-7.037, for the determination of crude protein in feed materials. The completely microprocessor-controlled instrument determines nitrogen by measuring the nitrogen gas following combustion of the sample; it was easy to operate and broadly applicable. A wide variety of feed materials of various nitrogen levels were analyzed in one mixed sequence. Results were precise, accurate, and rapid. Analysis time for one sample was approximately 3 min. Fourteen samples containing 2.5-15.5% N were selected for study and consisted of meals, grains, forages, and standard organic materials. The overall mean for the 14 samples by the LECO combustion method was 8.61% N compared with an overall mean of 8.58% N for the AOAC Kjeldahl method. Within-sample standard deviations for the LECO combustion method ranged from 0.013 to 0.052% N with a pooled standard deviation (SD) of 0.033% N for the 14 samples. Standard deviations for the AOAC Kjeldahl method ranged from 0.006 to 0.035% N with a pooled SD of 0.022% N. Combined average recovery of nitrogen from tryptophan, lysine-HCl, and EDTA determined by the LECO combustion method was 99.94% compared to 99.88% determined by the AOAC Kjeldahl method.  相似文献   

19.
A simple and specific method able to identify and quantify traces of 14 sulfonamide antibacterials (SAs) in milk and eggs is presented. This method uses a single solid-phase extraction (SPE) cartridge for simultaneous extraction and purification of SAs in the above matrices. Milk and egg samples are passed through a Carbograph 4 sorption cartridge. After analyte desorption, an aliquot of the final extract is injected into a liquid chromatography-mass spectrometry (LC-MS) instrument equipped with an electrospray ion source (ESI) and a single quadrupole. MS data acquisition is performed in the positive-ion mode and by a time-scheduled multiple-ion selected ion monitoring program. Compared to two published methods, the present protocol extracted larger amounts of SAs from both milk and egg and decreased the analysis time by a factor of 3 with milk samples and by a factor of 2 with egg samples. Recovery of SAs in milk at the 5 ppb level ranged between 76 and 112% with relative standard deviations (RSDs) of 相似文献   

20.
A collaborative study of a liquid chromatographic method for the determination of aflatoxins B1, B2, G1, and G2 was conducted in laboratories located in the United States, Canada, South Africa, and Switzerland. Twenty-one artificially contaminated raw peanuts, peanut butter, and corn samples containing varying amounts of aflatoxins B1, B2, G1, and G2 were distributed to participating laboratories. The test portion was extracted with methanol-0.1N HCl (4 + 1), filtered, defatted with hexane, and then partitioned with methylene chloride. The concentrated extract was passed through a silica gel column. Aflatoxins B1 and G1 were derivatized with trifluoroacetic acid, and the individual aflatoxins were determined by reverse-phase liquid chromatography with fluorescence detection. Statistical analysis of the data was performed to determine or confirm outliers, and to compute repeatability and reproducibility of the method. For corn, relative standard deviations for repeatability (RSDr) for aflatoxin B1 ranged from 27.2 to 8.3% for contamination levels from 5 through 50 ng/g. For raw peanuts and peanut butter, RSDr values for aflatoxin B1 were 35.0 to 41.2% and 11.2 to 19.1%, respectively, for contamination levels from 5 through 25 ng/g. RSDr values for aflatoxins B2, G1, and G2 were similar. Relative standard deviations for reproducibility (RSDr) for aflatoxin B1 ranged from 15.8 to 38.4%, 24.4 to 33.4%, and 43.9 to 54.0% for corn, peanut butter, and raw peanuts, respectively. The method has been adopted official first action for the determination of aflatoxins B1, B2, G1, and G2 in peanut butter and corn at concentrations greater than or equal to 13 ng total aflatoxins/g.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号