首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We conducted a retrospective study in presumed normal dogs to determine the adrenal gland attenuation and volume values. Multidetector computer tomography (MDCT 16) analysis of the gland was carried out in 48 adult dogs without evidence of adrenal gland disease that underwent CT examination for acute spinal injuries. The mean nonenhanced attenuation value +/- SD of the left adrenal gland was 36.0 +/- 5.3 HU (range: 22.0-42.0 HU). The mean nonenhanced attenuation value +/- SD of the right gland was 34.3 +/- 7.0 HU (range: 20.4-48.6HU). The mean enhanced attenuation value +/- SD were: left gland 101.5 +/- 10.6HU (range: 86.8-128.0 HU), and right gland 97.4 +/- 12.4 HU (range: 58.9-123.6 HU). The mean CT volume +/- SD were: left gland was 0.60 cm3 (range: 0.20-0.95; SD 0.17), and right gland (0.55cm3, range: 0.22-1.01; SD 0.19). Attenuation values and volume data were related to age, weight, and gender, using ANOVA. There was no statistically significant difference between the left and right side or in adrenal measurements, because of body weight class effects. The animal effect was the most important source of variation for all adrenal measurements. Based on our study, CT is an effective method for assessing adrenal characteristics in the dog. Normative CT data are provided to allow estimation of normal adrenal gland size and volume.  相似文献   

2.
Two-dimensional echocardiography was performed on Burmese pythons (Python molurus bivittatus) to determine an optimal echocardiographic imaging technique for snakes and to describe the echocardiographic anatomy of the snake heart. Five snakes immobilized with tiletamine/zolazepam and maintained on isoflurane in oxygen were imaged in dorsal recumbency. The portion of the snake's body containing the heart was submerged in warm water to reduce the artifact created by air trapped between and under the scales. Imaging in sagittal planes demonstrated the caudal vena cava, sinus venous valve, right atrium, various portions of the ventricle, horizontal septum, the left aortic arch, and pulmonary artery. Transverse imaging depicted the spatial relationship of the left and right aortic arches and pulmonary artery and the horizontal septum. Basic knowledge of cardiac blood flow in the reptile was necessary to understand the echocardiographic anatomy.  相似文献   

3.
OBJECTIVE: To evaluate the use of computed tomography (CT) for detection of pneumonia in snakes. ANIMALS: 8 clinically normal Indian pythons (Python molurus) and 5 pythons with evidence of respiratory tract disease. PROCEDURES: Preliminary examinations (clinical examination, conventional radiography, and microbiologic examination of a transtracheal wash sample) were performed. The lungs of each snake were then examined by use of CT performed in accordance with a standardized protocol. Structures of the lungs were assessed, and thickness and attenuation of the parenchyma were determined. RESULTS: It was possible to assess lung parenchyma in all pythons. Mean +/- SD attenuation in healthy pythons was -744.4 +/- 47.1 Hounsfield units. Significant differences were not evident between the right and left lungs or among measurement areas within a lung. In all Indian pythons with clinical signs of dyspnea and microbiologic detection of pathogens, hyperattenuation of the alveolar tissue was evident. CONCLUSIONS AND CLINICAL RELEVANCE: Analysis of the results revealed the benefit of CT for use in the diagnosis of pneumonia in snakes. A standardized protocol and reference values were established as a basis for CT assessment of the lungs of snakes.  相似文献   

4.
This retrospective study reviews the medical records of 301 reptiles with dermatological lesions that were examined at the Veterinary Medical Teaching Hospital, University of California at Davis (VMTH-UCD) and the Unité de Dermatologie-Parasitologie-Mycologie, Ecole Nationale Vétérinaire de Nantes (UDPM-ENVN) from 1 January 1992 to 1 July 2008. The most common reptile groups differed between the two hospitals, with lizards being the most common at the VMTH-UCD and chelonians at the UDPM-ENVN. At the VMTH-UCD, boa constrictors (Boa constrictor), ball pythons (Python regius) and other Python species were over-represented, and box turtles (Terrapene carolina) were under-represented in the dermatological lesion caseload. When institutional data were combined, 47% of all reptiles at both institutions with confirmed or suspected cases of sepsis had petechiae, with the highest association seen in chelonians at 82%. Dependent on institution and reptile group, from 29% to 64% of the cases had underlying husbandry issues. Sixty-two per cent of all cases were alive at final status. Veterinarians treating reptiles with skin disease should be aware of the following: (i) that boa constrictors and Python species may be predisposed to dermatological lesions; (ii) that client education is important for proper husbandry; and (iii) that there is a possible association between petechiae and sepsis, especially in chelonians. The conjectural association between certain skin lesions and sepsis remains to be confirmed by systematically derived data that demonstrate a causal relationship between the two.  相似文献   

5.
X‐ray attenuation of the liver has been measured using computed tomography (CT) and reported to decrease in cats with experimentally induced hepatic lipidosis. To assess the clinical utility of this technique, medical records and noncontrast CT scans of a series of cats were retrospectively reviewed. A total of 112 cats met inclusion criteria and were stratified into three hepatic lipidosis risk groups. Group 1 cats were considered low‐risk based on no history of inappetence or weight loss, and normal serum chemistry values; Group 2 cats were considered intermediate risk based on weight loss, serum hepatic enzymes above normal limits, or reasonably controlled diabetes mellitus; and Group 3 cats were considered high risk based on poorly controlled diabetes mellitus due to hypersomatotropism. Mean CT attenuation values (Hounsfield units, HU) were measured using regions of interest placed within the liver and cranial pole of the right kidney. Hepatic and renal attenuation were weakly positively correlated with each other (r = 0.2, P = 0.03) and weakly negatively correlated with body weight (r = ?0.21, P = 0.05, and r = ?0.34, P = 0.001, respectively). Mean (SD) hepatic and renal cortical attenuation values were 70.7 (8.7) HU and 49.6 (9.2) HU for Group 1 cats, 71.4 (7.9) HU and 48.6 (9.1) HU for Group 2, and 68.9 (7.6) HU and 47.6 (7.2) HU for Group 3. There were no significant differences in hepatic or renal attenuation among groups. Findings indicated that CT measures of X‐ray attenuation in the liver and kidney may not be accurate predictors of naturally occurring hepatic lipidosis in cats.  相似文献   

6.
We conducted a retrospective study to determine whether multidetector computed tomography (CT) could be of value for adrenal gland assessment in dogs with pituitary-dependent hyperadrenocorticism. Adrenal gland attenuation and volume values of 49 dogs with hyperadrenocorticism were recorded and age, body weight, and gender were examined to determine if a relationship existed between these variables and adrenal gland morphology. There was not a statistically significant difference in mean X-ray attenuation of the left vs. right adrenal gland in normal dogs (35.3 +/- 6.1 HU), or in dogs with hyperadrenocorticism. The mean adrenal X-ray attenuation (+/- standard deviation [SD]) in dogs with microadenoma was 33.1 +/- 6.8 vs. 31.8 +/- 12.7 HU for dogs with macroadenoma, and these values were not statistically different. The mean volume of the left adrenal gland in normal dogs (0.59 +/- 0.17 cm3) was greater than that of the right adrenal gland (0.54 +/- 0.19 cm3) (P < 0.05). The mean CT volume (+/- SD) of the adrenal glands in dogs with microadenoma vs. macroadenoma were 1.60 +/- 1.25 vs. 2.88 +/- 1.60 cm3, respectively. There was no effect of age or gender on adrenal gland morphology or X-ray attenuation. The weight effect was the most important source of variation for the volume measurement in dogs with hyperadrenocorticism.  相似文献   

7.
Hyperthyroidism is the most common feline endocrinopathy; thyroid computed tomography (CT) may improve disease detection and methimazole dose selection. Objectives of this experimental pre‐post with historical case‐control study were to perform thyroid CT imaging in awake or mildly sedated hyperthyroid cats, compare thyroid gland CT appearance in euthyroid and hyperthyroid cats pre‐ and postmethimazole treatment, and determine whether thyroid size or attenuation correlate with methimazole dose needed for euthyroidism. Premethimazole treatment, eight hyperthyroid cats received CT scans from the head to heart, which were compared to CT of seven euthyroid cats. Total thyroxine levels were monitored every 3–4 weeks. Postmethimazole CT was performed 30 days after achieving euthyroid status. Computed tomography parameters recorded included thyroid length, width, height, attenuation, and heterogeneity. Median time between CT was 70 days (53–213 days). Mild sedation was needed in five hyperthyroid cats premethimazole, and none postmethimazole. Thyroid volume was significantly larger in hyperthyroid cats compared to euthyroid cats (785.0 mm3 vs. 154.9 mm3; P = 0.002) and remained unchanged by methimazole treatment (?4.5 mm3; P = 0.50). Thyroid attenuation and heterogeneity decreased with methimazole treatment (96.1 HU vs. 85.9 HU; P = 0.02. 12.4 HU vs. 8.1 HU; P = 0.009). Methimazole dose ranged from 2.5 to 10 mg daily with a positive correlation between pretreatment thyroid gland volume and dose needed to achieve euthyroidism (P = 0.03). Euthyroid and hyperthyroid cats are easily imaged awake or mildly sedated with CT. Methimazole in hyperthyroid cats significantly lowers thyroid attenuation and heterogeneity, but not size.  相似文献   

8.
OBJECTIVE: To compare quantitative densitometric computed tomography (CT), morphometric, and histologic data of normal lungs in dogs with similar parameters obtained after induction of an acute inflammatory response and determine whether CT densitometry correlated with histopathologic changes. ANIMALS: 6 healthy adult dogs. PROCEDURE: After initial CT, 1 mL of 0.1 M hydrochloric acid (HCI) and 3 mL of autologous blood were instilled into the right middle (RM) and caudal segment of the left cranial (LCCd) lung lobes, respectively. Immediately and 24 hours after instillation, CT was repeated. At 24 hours, dogs were euthanatized and lungs were fixed and sampled for morphometric and histologic evaluation. The CT data were compared with lung morphology and morphometry by use of unpaired t tests. Comparison with lungs from control dogs was performed using Spearman rank correlation coefficients. RESULT: Mean Hounsfield units (HU) from control and baseline HU from experimental dogs were identical. Immediately after instillation of HCI or blood, there was increased attenuation in both lobes. Autologous blood initially induced severe changes that almost completely resolved at 24 hours; HCI induced severe changes at 24 hours. Significant increases in percentage of parenchymal airspace and alveolar diameter resulted in decreased surface area-to-volume ratio in lobes receiving HCl. Histologic scores were significantly higher in the RM lobe, compared with controls. CONCLUSIONS AND CLINICAL RELEVANCE: Computed tomography attenuation correlated well with histomorphometry and histologic findings in this model. Lung lesions after autologous blood were transient and of limited severity. Lesions induced by HCl were severe; alterations in morphometric and histologic parameters were reflected in CT attenuation measurements.  相似文献   

9.
Sixteen boa constrictors (Boa constrictor), three royal pythons (Python regius) and 15 Burmese pythons (Python molurus bivittatus) were examined endoscopically by access through the air sac. The snakes were immobilised in a ventral position using a half-open anaesthetic system with assisted ventilation and a mixture of isoflurane and oxygen. The rigid endoscope was introduced percutaneously and the internal structure of the lungs and the air sac, and the shape, size and external surface of the liver were visible in the cranial direction. In the smaller snakes the bifurcation and caudal part of the trachea could be viewed, provided the endoscope was positioned in a retrograde orientation. The caudal orientation of the endoscope made it possible to view the gall bladder and the size, shape and surface of the spleen. In some cases, the pancreas and the surface of the stomach and colon could be monitored. Endoscopy through the air sac also made it possible to check the major veins in the coelom. The snakes were monitored for at least 30 days after the intervention and no changes in their respiratory function or general health were observed.  相似文献   

10.
A nine-year-old German Shepherd dog presented to the Veterinary Teaching Hospital at North Carolina State University with an eleven-day history of progressive depression, lethargy, inability to walk, blindness and intermittent vomiting. Computed tomography (CT) of the brain was unremarkable; however, bilateral regions of low photon absorption were noted within the tentorium cerebelli osseum. Mean CT numbers of −47.9 Hounsfield units (HU) and −26.4 HU were recorded within the left and right areas, respectively. These areas most likely represent diploë and are presumably a normal variant of the canine skull. A possible explanation for this finding includes a developmental variant where the medial and lateral plates of the tentorium cerebelli osseum fail to fuse, thus leaving a space for diploë accumulation. Use of various combinations of CT windows and numbers can be valuable for characterizing such variants.  相似文献   

11.
The influence of body position on volume and x-ray attenuation of the lungs of three Beagles was investigated with computed tomography. In left and right lateral recumbency, the dependent lung had decreased volume and increased x-ray attenuation compared with ventral recumbency. Volume and x-ray attenuation of the nondependent lung, however, were unchanged. In dorsal recumbency, there was a vertical gradient of x-ray attenuation being increased dorsally and decreased ventrally compared with ventral recumbency where regional differences in x-ray attenuation were not found. Results indicate a risk of overlooking a mass in the dependent pulmonary parenchyma of dogs in lateral and dorsal recumbency. Regional differences in x-ray attenuation of the lungs of dogs can be avoided if the radiographs are obtained with the dog in ventral recumbency.  相似文献   

12.
Previous lymphangiographic studies have investigated the use of computed tomography (CT) for characterizing the thoracic duct and its tributaries in dogs. However, there is limited published information on the appearance of the canine cisterna chyli using CT. The objective of this retrospective study was to describe the features of the canine cisterna chyli in pre‐ and post‐contrast abdominal CT studies. The presence, location, shape, maximum width, size compared with the aortic diameter (Ao:cisterna chyli ratio) and mean attenuation of the cisterna chyli were recorded from archived abdominal CT scans of 30 dogs. Breed, age, sex and neutering status were also noted. A cisterna chyli was identified in 26 of the dogs (87%). In 22 cases a cisterna chyli could be reliably identified prior to intravenous contrast administration and in all 26 cases in postcontrast images. The cisterna chyli was most commonly located right dorsolateral to the abdominal aorta between L1 and L4. Shape varied on transverse images from crescent‐like to globular and maximum diameters ranged from 5 to 9 mm. The Ao:cisterna chyli ratio varied between 0.29 and 0.71 (mean value—males: 0.32; females: 0.38). On pre‐contrast images the mean Hounsfield units were 21.3HU (range: –3.8 to 64.25). Mild enhancement of the cisterna chyli post‐contrast was observed in 24 dogs (80%). Findings supported the use of pre‐ and post‐contrast abdominal CT as a non‐invasive method for assessing qualitative and quantitative characteristics of the canine cisterna chyli.  相似文献   

13.
Though identification of lymph nodes is essential in staging cancer patients, little has been reported about the CT features of canine abdominal lymph nodes. The purpose of this retrospective study was to describe the visibility, location, and characteristics of abdominal lymph nodes in abdominal CT studies of dogs considered unlikely to have lymphadenopathy. The relationship between the number of identified lymph nodes and intraabdominal fat ranking, body weight, and slice thickness was also investigated. A total of 19 dogs were included. At least two jejunal lymph nodes and both left and right medial iliac lymph nodes were identified in all dogs. Colic lymph nodes were not identified in any of the dogs. Visualization of all other lymph nodes varied. There were significantly more lymph nodes visible in dogs with more intraabdominal fat (P < 0.0001). No correlation between the number of identified lymph nodes and body weight (P = 0.64) or slice thickness (P = 0.76) was found. Though most of all identified lymph nodes had an elongated shape, a rounded shape was most common in splenic, pancreaticoduodenal, renal, ileocolic and caudal mesenteric lymph nodes. Most lymph nodes had a homogeneous structure before and following the intravenous administration of contrast medium. Some lymph nodes had a slightly irregular structure or were relatively more hyper attenuating in the periphery than centrally before and/or after contrast administration. Mean attenuation before contrast was 37 Hounsfield Units (HU) (range 20–52 HU), and 109 HU after contrast (range 36–223 HU). Findings indicated that the CT visibility, characteristics of different abdominal lymph nodes may be variable in dogs.  相似文献   

14.
OBJECTIVE: To establish a safe and effective technique for the endoscopic examination and biopsy of snake lungs by use of a 2.7-mm rigid endoscope system. DESIGN: Clinical trial. ANIMALS: 17 adult ball pythons (Python regius). PROCEDURES: The right lung of each anesthetized snake was transcutaneously penetrated at a predetermined site. Endoscopic lung examination was objectively scored, and 3 lung biopsies were performed. Tissue samples were evaluated histologically for diagnostic quality. One year later, 11 of the 17 snakes again underwent pulmonoscopy and biopsy; specimens were placed in various fixatives to compare preservation quality. All 17 snakes were euthanatized and necropsied. RESULTS: No major anesthetic, surgical, or biopsy-associated complications were detected in any snake. In 16 of 17 pythons, ease of right lung entry was satisfactory to excellent, and views of the distal portion of the trachea; primary bronchus; intrapulmonary bronchus; cranial lung lobe; and faveolar, semisaccular, and saccular lung regions were considered excellent. In 1 snake, mild hemorrhage caused minor procedural difficulties. After 1 year, pulmonoscopy revealed healing of the previous transcutaneous lung entry and biopsy sites. Important procedure-induced abnormalities were not detected at necropsy. Diagnostic quality of specimens that were shaken from biopsy forceps into physiologic saline (0.9% NaCl) solution before fixation in 2% glutaraldehyde or neutral-buffered 10% formalin was considered good to excellent. CONCLUSIONS AND CLINICAL RELEVANCE: By use of a 2.7-mm rigid endoscope, lung examination and biopsy can be performed safely, swiftly, and with ease in ball pythons. Biopsy specimens obtained during this procedure are suitable for histologic examination.  相似文献   

15.
Detection of wooden foreign bodies in dogs can be challenging. A retrospective, cross‐sectional study was done to describe computed tomographic (CT) signs associated with wooden foreign bodies, and to estimate the accuracy of CT for detection of wooden foreign bodies. Patient records and CT images were reviewed for 72 dogs that had a history of suspected stick injury and CT of the affected body part, or possible wooden foreign object reported on CT, and had surgical exploration during the same period of hospitalization. Duration of clinical signs was acute in 48 (67%) dogs and chronic in 24 (33%). Wood was removed from 55 dogs, including a piece of a tree or shrub in 33 (60%) instances, kebab stick in 8 (15%), piece of bamboo garden cane in 2 (4%), cocktail stick in 2 (4%), thorn in 1 (2%), and unidentified wood in the remaining nine instances. Based on review of CT images with knowledge of the surgical findings, sensitivity of CT for wooden foreign bodies was 79% (95% CI 65%–89%), specificity 93% (78%–98%), positive likelihood ratio 11.5 (2.9–44.1), and negative likelihood ratio 0.23 (0.13–0.41). Wooden foreign bodies were predominantly rectangular or linear, with median length 48 mm (range 2–270 mm), median thickness 3 mm (range 1–22 mm), and median attenuation 111 HU (range ?344 to +640 HU). A CT finding of gas in soft tissues was significantly associated with acute cases, whereas suspected foreign material, cavitary lesions, fat stranding, and periosteal reaction on adjacent bones were associated with chronic cases.  相似文献   

16.
Freshwater turtle species are suffering from anthropocentric‐caused population declines, making preservation of professionally managed populations increasingly important. Turtles under professional care have an increased risk to develop hepatic lipidosis, potentially resulting in early death. Computed tomography can provide an antemortem screening for increased fatty liver composition. A goal of this prospective analytical cross‐sectional study was to assess the hepatic attenuation measured as Hounsfield units (HU) in a wild population of a freshwater turtle species, and then compare hepatic HU to freshwater turtles under professional care. Ninety‐five wild Blanding's turtles (BT; Emydoidea blandingii) as well as 10 Vietnamese Pond turtles (VPT; Mauremys annamensis) and six Northern Snake‐Necked turtles (NSNT; Chelodina oblonga) under professional care underwent CT with quantification of hepatic HU. Hepatic HU were correlated to serum chemistry findings and the presence of follicles was recorded in BT. The mean (±SD) hepatic attenuation for 95 wild BT was 97.5 HU ±9.6. There were significant differences in hepatic attenuation among VPT, NSNT, and BT, with median HU values (range) of 5.39 HU (–6.45 to 61.50), 71.74 HU (59.44‐94.49), and 95.43 HU (74.41‐124.56), respectively. Aspartate aminotransferase (AST) values had a weak negative correlation to HU with a coefficient of –0.85 (P < .001). The hepatic attenuation was significantly higher for individuals undergoing folliculogenesis (P = .007). The decreased HU values were significantly negatively correlated with AST values. Findings supported the use of CT as an aid for guiding future management practices in freshwater turtles.  相似文献   

17.
ObjectivesTo determine if microdose contrast-enhanced multi-detector computed tomographic angiography (MDCTA) allows characterization of cardiac chambers in lightly sedated normal cats.AnimalsSeven healthy domestic cats.MethodsLightly sedated normal cats were imaged pre-contrast and with microdose (0.22 ml/kg of non-ionic iodinated contrast medium, 300 mg I/ml) triple-phase MDCTA in a motion restriction device.ResultsOn pre-contrast images, the aorta (median: 52.43 Hounsfield units [HU], range 27.35–76.74 HU) was outlined by significantly (p = 0.015) lower attenuating periaortic fat (−66.16 HU, −42.62 to −92.77 HU). On post-contrast images, median peak contrast enhancement in the right ventricle (111.77 HU, 36.09–141.60 HU) was achieved in 3.1 s (range 2.9–7.3 s), in the aorta (149.30 HU, 99.43–319.60 HU) and left atrium (180.83 HU, 88.53–266.84 HU) in 6.4 s (range 5.6–7.7 s) and in the left ventricle (147.89 HU, 57.23–245.77 HU) in 7.10 s (range 6.2–11.2 s). Significantly higher attenuation was measured between all chambers and walls, the right ventricular lumen and interventricular septum (median ratio 53.78 HU, range 0.21–83.20 HU), left ventricular lumen and left ventricular free wall (89.32 HU, 38.81–185.95 HU) and aorta and periaortic fat (190.43 HU, 143.22–425.44 HU) on post-contrast images.ConclusionsSufficient biological contrast is available on survey CT to discriminate between the aorta and the left atrium, and microdose MDCTA provides sufficient contrast enhancement for adequate visualization of the heart chambers in normal cats.  相似文献   

18.
The sacroiliac region in 33 clinically normal riding horses was examined with scintigraphy to determine the normal scintigraphic appearance, to evaluate a semiquantitative method used to calculate a sacroiliac joint (SI joint) ratio, and to identify factors that affect the scintigraphic appearance of the pelvis. The scintigraphic examination included dorsal views of each SI joint region and one lateral view of the urinary bladder. Two predefined areas (the SI joint and the area between the tuber sacrale and the SI joint) were evaluated subjectively by comparing the intensity in each area to the intensity in the tuber sacrale, and a semiquantitative method was applied on the images to calculate an SI joint ratio. The thickness of the muscle mass overlying each SI joint was measured by using ultrasound. A corrected ratio was calculated based on a corrected pixel count for each SI joint. Of 29 evaluated horses, 28 had normal radiotracer uptake in the SI joints and 10 horses had symmetric normal radiotracer uptake in the area between the tuber sacrale and the SI joint. The mean SI joint ratio was 0.53 on both the left and right sides, and the mean corrected SI joint ratio was 2.15 on the left side and 2.13 on the right side. Factors that affect the scintigraphic appearance of the pelvis were identified and included attenuation, radioactive urine, and muscle symmetry. The muscle thickness ranged from 8-11 cm, causing 71-82% attenuation. Radioactive urine in the urinary bladder was located ventral to the SI joint region in 16 horses, and four of these were excluded from further evaluation because of risk of misinterpretation. A visual assessment of symmetry of the horses' gluteal muscle mass was compared with the ultrasound measurements. Fourteen horses (14/33) were regarded symmetric by both techniques. Soft tissue attenuation was found to severely compromise the result and indicated that only lesions in the SI joint with severely increased radiotracer uptake can be detected with scintigraphy. Knowledge about presence of radioactive urine ventral to the SI joint region and assessment of muscle symmetry is essential for a correct subjective evaluation. Any situation with difference in muscle mass between the left and right side of the pelvis will give a false impression of increased radiotracer uptake on the side with lesser muscle mass.  相似文献   

19.
The ability of computed tomography (CT) to distinguish malignant from nonmalignant splenic masses was evaluated in 21 dogs with 24 masses. CT scans of the abdomen were performed pre- and postintravenous contrast medium administration before splenectomy or euthanasia. Splenic masses were evaluated objectively based on Hounsfield units (HU) and volume. Subjective criteria included location within the spleen (head, body, or tail), margination, homogeneity, and attenuation compared to the remaining splenic parenchyma. Characteristics of malignant and nonmalignant masses were compared. The nonmalignant masses were divided into splenic hematomas and nodular hyperplasia for further analysis. Fourteen (58.3%) of the masses were nonmalignant; 10 (41.7%) were malignant. Malignant splenic masses had significantly lower attenuation values, measured in HU, than nonmalignant splenic masses, on both pre- and postcontrast images (P<0.05). On postcontrast images, there was a significant difference in attenuation characteristics among all three subsets of splenic masses (malignant, hematoma, hyperplasia), with nodular hyperplasia having the highest HU values (90.3), hematomas having intermediate HU values (62.5), and malignant splenic masses having the lowest HU values (40.1). A receiver operator characteristic curve of postcontrast medium HU values revealed 55 as the best threshold value to distinguish malignant from nonmalignant masses, with those less than the threshold value being malignant. Abdominal CT is a useful diagnostic imaging modality for evaluation of focal canine splenic masses, with a significant difference in imaging characteristics between malignant and nonmalignant masses.  相似文献   

20.
We studied the computed tomographic (CT) appearance and determined Hounsfield units (HU) for normal thyroid tissue in eight cats. Helical CT images (2 mm collimation) were acquired from cranial aspect of the second cervical vertebra (C2) through caudal aspect of the fourth cervical vertebra (C4). Data were acquired before contrast medium administration (n = 7), after delayed contrast medium enhancement (n = 8), and immediately after contrast medium enhancement after a second dose of contrast medium (n = 8). Attenuation of thyroid tissue was compared with surrounding tissues. Before contrast medium enhancement, thyroid tissue was hyperattenuating to the surrounding soft tissues. After delayed contrast medium enhancement, thyroid tissue was hyperattenuating to surrounding soft tissues and isoattenuating to contrast medium-laden blood vessels. Immediately after contrast medium enhancement, thyroid tissue was hyperattenuating to surrounding soft tissues and hypoattenuating to contrast medium-laden blood vessels. The thyroid glands were dorsolateral to the trachea, ovoid, and displayed homogenous contrast medium enhancement. Circular regions of interest were drawn on the right and left thyroid lobes. Densitometric data of thyroid tissue were as follows: precontrast medium enhancement, 123.2 HU (95% CI: 119.4-127.1 HU); delayed contrast medium enhancement, 132.1 HU (95% CI: 127.4-136.8 HU); immediate postcontrast medium enhancement, 168.5 HU (95% CI: 163-173.9 HU). Normal feline thyroid tissue is easily detected using CT without contrast medium enhancement. This information may be useful for CT evaluation of abnormal feline thyroid glands.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号